Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2000;101:812-818

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Garasic, J. M.
Right arrow Articles by Rogers, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Garasic, J. M.
Right arrow Articles by Rogers, C.
Related Collections
Right arrow Restenosis
Right arrow Animal models of human disease
Right arrow Quantitative modeling
Right arrow Catheter-based coronary interventions: stents

(Circulation. 2000;101:812.)
© 2000 American Heart Association, Inc.


Basic Science Reports

Stent and Artery Geometry Determine Intimal Thickening Independent of Arterial Injury

Joseph M. Garasic, MD; Elazer R. Edelman, MD, PhD; James C. Squire, MS; Philip Seifert, MS; Michael S. Williams, BA; Campbell Rogers, MD

From the Department of Medicine (Cardiac Catheterization Laboratory and Coronary Care Unit, Brigham and Women’s Hospital), Harvard Medical School, Boston, Mass (J.M.G., E.R.E., C.R.); the Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Mass (E.R.E., J.C.S., P.S., C.R.); and Medtronic/Arterial Vascular Engineering, Santa Rosa, Calif (M.S.W.).

Correspondence to Joseph Garasic, MD, Brigham and Women’s Hospital, 75 Francis St, Boston, MA 02115. E-mail jmgarasic{at}bics.bwh.harvard.edu

Background—Clinical trials show that larger immediate postdeployment stent diameters provide greater ultimate luminal size, whereas animal data show that arterial injury and stent design determine late neointimal thickening. At deployment, a stent stretches a vessel, imposing a cross-sectional polygonal luminal shape that depends on the stent design, with each strut serving as a vertex. We asked whether this design-dependent postdeployment luminal geometry affects late neointimal thickening independently of the extent of strut-induced injury.

Methods and Results—Stainless steel stents of 3 different configurations were implanted in rabbit iliac arteries for 3 or 28 days. Stents designed with 12 struts per cross section had 50% to 60% less mural thrombus and 2-fold less neointimal area than identical stents with only 8 struts per cross section. Sequential histological sectioning of individual stents showed that immediate postdeployment luminal geometry and subsequent neointimal area varied along the course of each stent subunit. Mathematical modeling of the shape imposed by the stent on the artery predicted late neointimal area, based on the re-creation of a circular vessel lumen within the confines of the initial stent-imposed polygonal luminal shape.

Conclusions—Immediate postdeployment luminal geometry, dictated by stent design, determines neointimal thickness independently of arterial injury and may be useful for predicting patterns of intimal growth for novel stent designs.


Key Words: stents • restenosis • angioplasty • pathology




This article has been cited by other articles:


Home page
Circ Cardiovasc InterventHome page
R. S. Schwartz, E. Edelman, R. Virmani, A. Carter, J. F. Granada, G. L. Kaluza, N. A.F. Chronos, K. A. Robinson, R. Waksman, J. Weinberger, et al.
Drug-Eluting Stents in Preclinical Studies: Updated Consensus Recommendations for Preclinical Evaluation
Circ Cardiovasc Intervent, October 1, 2008; 1(2): 143 - 153.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
C J Dean, A C Morton, N D Arnold, D R Hose, D C Crossman, and J Gunn
Relative importance of the components of stent geometry to stretch induced in-stent neointima formation
Heart, December 1, 2005; 91(12): 1603 - 1604.
[Full Text] [PDF]


Home page
CirculationHome page
S. Windecker, R. Simon, M. Lins, V. Klauss, F. R. Eberli, M. Roffi, G. Pedrazzini, T. Moccetti, P. Wenaweser, M. Togni, et al.
Randomized Comparison of a Titanium-Nitride-Oxide-Coated Stent With a Stainless Steel Stent for Coronary Revascularization: The TiNOX Trial
Circulation, May 24, 2005; 111(20): 2617 - 2622.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
J. F. LaDisa Jr., Lars. E. Olson, R. C. Molthen, D. A. Hettrick, P. F. Pratt, M. D. Hardel, J. R. Kersten, D. C. Warltier, and P. S. Pagel
Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries
Am J Physiol Heart Circ Physiol, May 1, 2005; 288(5): H2465 - H2475.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. F. LaDisa Jr., L. E. Olson, I. Guler, D. A. Hettrick, J. R. Kersten, D. C. Warltier, and P. S. Pagel
Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models
J Appl Physiol, March 1, 2005; 98(3): 947 - 957.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. F. LaDisa Jr., L. E. Olson, I. Guler, D. A. Hettrick, S. H. Audi, J. R. Kersten, D. C. Warltier, and P. S. Pagel
Stent design properties and deployment ratio influence indexes of wall shear stress: a three-dimensional computational fluid dynamics investigation within a normal artery
J Appl Physiol, July 1, 2004; 97(1): 424 - 430.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. F. LaDisa Jr., D. A. Hettrick, L. E. Olson, I. Guler, E. R. Gross, T. T. Kress, J. R. Kersten, D. C. Warltier, and P. S. Pagel
Stent implantation alters coronary artery hemodynamics and wall shear stress during maximal vasodilation
J Appl Physiol, December 1, 2002; 93(6): 1939 - 1946.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
J Gunn, N Arnold, K H Chan, L Shepherd, D C Cumberland, and D C Crossman
Coronary artery stretch versus deep injury in the development of in-stent neointima
Heart, October 1, 2002; 88(4): 401 - 405.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
N. J Alp, N. E.J West, N. Arnold, J. Gunn, A. P Banning, and K. M Channon
Increased intimal hyperplasia in experimental vein graft stenting compared to arterial stenting: comparisons in a new rabbit model of stent injury
Cardiovasc Res, October 1, 2002; 56(1): 164 - 172.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. S. Schwartz, E. R. Edelman, A. Carter, N. Chronos, C. Rogers, K. A. Robinson, R. Waksman, J. Weinberger, R. L. Wilensky, D. N. Jensen, et al.
Drug-Eluting Stents in Preclinical Studies: Recommended Evaluation From a Consensus Group
Circulation, October 1, 2002; 106(14): 1867 - 1873.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
C. Briguori, C. Sarais, P. Pagnotta, F. Liistro, M. Montorfano, A. Chieffo, F. Sgura, N. Corvaja, R. Albiero, G. Stankovic, et al.
In-stent restenosis in small coronary arteries: Impact of strut thickness
J. Am. Coll. Cardiol., August 7, 2002; 40(3): 403 - 409.
[Abstract] [Full Text] [PDF]


Home page
Circ. Res.Home page
C.-W. Hwang and E. R. Edelman
Arterial Ultrastructure Influences Transport of Locally Delivered Drugs
Circ. Res., April 19, 2002; 90(7): 826 - 832.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
S. Windecker and B. Meier
All stents are not alike or is the difference in the eye of the observer only?
Eur. Heart J., November 1, 2001; 22(21): 1973 - 1977.
[PDF]


Home page
Eur Heart JHome page
R. Hoffmann, C. Jansen, A. Konig, P.K. Haager, G. Kerckhoff, J. Vom Dahl, V. Klauss, P. Hanrath, and H. Mudra
Stent design related neointimal tissue proliferation in human coronary arteries; an intravascular ultrasound study
Eur. Heart J., November 1, 2001; 22(21): 2007 - 2014.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
P. Tozzi, J. O. Solem, D. Boumzebra, A. Mucciolo, C. Y. Genton, P. Chaubert, and L. K. von Segesser
Is the GraftConnector a valid alternative to running suture in end-to-side coronary arteries anastomoses?
Ann. Thorac. Surg., September 1, 2001; 72(3): S999 - 1003.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. Kastrati, J. Mehilli, J. Dirschinger, F. Dotzer, H. Schuhlen, F.-J. Neumann, M. Fleckenstein, C. Pfafferott, M. Seyfarth, and A. Schomig
Intracoronary Stenting and Angiographic Results : Strut Thickness Effect on Restenosis Outcome (ISAR-STEREO) Trial
Circulation, June 12, 2001; 103(23): 2816 - 2821.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
E. R. Edelman, P. Seifert, A. Groothuis, A. Morss, D. Bornstein, and C. Rogers
Gold-Coated NIR Stents in Porcine Coronary Arteries
Circulation, January 23, 2001; 103(3): 429 - 434.
[Abstract] [Full Text] [PDF]


Home page
Circ. Res.Home page
C.-W. Hwang and E. R. Edelman
Arterial Ultrastructure Influences Transport of Locally Delivered Drugs
Circ. Res., April 19, 2002; 90(7): 826 - 832.
[Abstract] [Full Text] [PDF]