(Circulation. 2000;102:1407.)
© 2000 American Heart Association, Inc.
Clinical Investigation and Reports |
From Riverside-Methodist Hospital, Columbus, Ohio (E.G.D.); Academic Hospital Maastricht, the Netherlands (C.T.); Virginia Mason Medical Center, Seattle, Wash (C.F.); Iowa Heart Institute, Des Moines, Iowa (R.H.); Rhode Island Hospital, Providence, RI (R.L.); and InControl/Guidant, Inc, Redmond, Wash/St Paul, Minn (K.D., G.M.A.).
Correspondence to Emile Daoud, MD, MidOhio Cardiology Research, 3545 Olentangy River Rd, Room 325, Columbus, OH 43214. E-mail egd{at}mocc.cc
BackgroundA recent study has shown that the implantable atrial defibrillator can restore sinus rhythm in patients with recurrent atrial fibrillation when therapy was delivered under physician observation. The objective of this study was to evaluate the safety and efficacy of ambulatory use of the implantable atrial defibrillator.
Methods and ResultsAn atrial defibrillator was implanted in 105 patients (75 men; mean age, 59±12 years) with recurrent, symptomatic, drug-refractory atrial fibrillation. After successful 3-month testing, patients could transition to ambulatory delivery of shock therapy. Patients completed questionnaires regarding shock therapy discomfort and therapy satisfaction using a 10-point visual-analog scale (1 represented "not at all," 10 represented "extremely") after each treated episode of atrial fibrillation. During a mean follow-up of 11.7 months, 48 of 105 patients satisfied criteria for transition and received therapy for 275 episodes of atrial fibrillation. Overall shock therapy efficacy was 90% with 1.6±1.2 shocks delivered per episode (median, 1). Patients rated shock discomfort as 5.2±2.4 for successful therapy and 4.2±2.2 for unsuccessful therapy (P>0.05). The satisfaction score was higher for successful versus unsuccessful therapy (3.4±3.3 versus 8.7±1.3, P<0.05). There was no ventricular proarrhythmia observed throughout the course of this study.
ConclusionsAmbulatory use of an implantable atrial defibrillator can safely and successfully convert most episodes of atrial fibrillation, often requiring only a single shock. Successful therapy is associated with high satisfaction and only moderate discomfort.
Key Words: defibrillation shock cardioversion outpatient therapy
This article has been cited by other articles:
![]() |
E. A. Stephenson and C. I. Berul Electrophysiological Interventions for Inherited Arrhythmia Syndromes Circulation, August 28, 2007; 116(9): 1062 - 1080. [Full Text] [PDF] |
||||
![]() |
Z. Goldberger and R. Lampert Implantable Cardioverter-Defibrillators: Expanding Indications and Technologies JAMA, February 15, 2006; 295(7): 809 - 818. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.C. Geller, S. Reek, C. Timmermans, T. Kayser, H.-F. Tse, C. Wolpert, W. Jung, A.J. Camm, C.-P. Lau, H. J.J. Wellens, et al. Treatment of atrial fibrillation with an implantable atrial defibrillator -- long term results Eur. Heart J., December 1, 2003; 24(23): 2083 - 2089. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Manoharan, N. Evans, B. Kidwai, D. Allen, J. Anderson, and J. Adgey Novel Passive Implantable Atrial Defibrillator Using Transcutaneous Radiofrequency Energy Transmission Successfully Cardioverts Atrial Fibrillation Circulation, September 16, 2003; 108(11): 1382 - 1388. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Khairy and S. Nattel New insights into the mechanisms and management of atrial fibrillation Can. Med. Assoc. J., October 29, 2002; 167(9): 1012 - 1020. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Schwartzman, S. K. Musley, C. Swerdlow, R. H. Hoyt, and E. N. Warman early recurrence of atrial fibrillation after ambulatory shock conversion J. Am. Coll. Cardiol., July 3, 2002; 40(1): 93 - 99. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Cooper, M. S. Katcher, and M. V. Orlov Implantable Devices for the Treatment of Atrial Fibrillation N. Engl. J. Med., June 27, 2002; 346(26): 2062 - 2068. [Full Text] [PDF] |
||||
![]() |
X. Zheng, M. E. Benser, G. P. Walcott, and R. E. Ideker Right Atrial Septal Electrode for Reducing the Atrial Defibrillation Threshold Circulation, August 28, 2001; 104(9): 1066 - 1070. [Abstract] [Full Text] [PDF] |
||||
![]() |
Ambulatory Use of Atrial Defibrillators -- Is It for Real? Journal Watch Cardiology, December 1, 2000; 2000(1201): 6 - 6. [Full Text] |
||||
![]() |
Early Experience with Atrial Defibrillator Favorable -- for Some Journal Watch (General), October 3, 2000; 2000(1003): 2 - 2. [Full Text] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2000 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |