Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2000;102:1657-1663

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hibi, K.
Right arrow Articles by Fitzgerald, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hibi, K.
Right arrow Articles by Fitzgerald, P. J.
Related Collections
Right arrow Coronary imaging: angiography/ultrasound/Doppler/CC

(Circulation. 2000;102:1657.)
© 2000 American Heart Association, Inc.


Clinical Investigation and Reports

Feasibility of a Novel Blood Noise Reduction Algorithm to Enhance Reproducibility of Ultra–High-Frequency Intravascular Ultrasound Images

Kiyoshi Hibi, MD; Atsushi Takagi, MD; Xiangmin Zhang, PhD; Tat-Jin Teo, PhD; Heidi N. Bonneau, RN, MS; Paul G. Yock, MD; Peter J. Fitzgerald, MD, PhD

From the Division of Cardiovascular Medicine, Stanford University Medical Center, Stanford, Calif (K.H., A.T., P.G.Y., P.J.F.), and Boston Scientific Corp (X.Z., T.-J.T.) and Highlands Consulting, Inc (H.N.B.), San Jose, Calif.

Correspondence to Peter J. Fitzgerald, MD, PhD, Center for Research in Cardiovascular Interventions, Stanford University Medical Center, 300 Pasteur Dr, Room H3554, Stanford, CA 94305.

Background—Ultra–high-frequency (40- to 50-MHz) intravascular ultrasound (IVUS) improves image quality compared with conventional 20- to 30-MHz IVUS. However, as the frequency of IVUS increases, high-intensity backscatter from blood components may cause visual difficulties in discrimination between the lumen and arterial wall structure. The purpose of this study was to evaluate the effect of a novel blood noise reduction algorithm (BNR) on quantitative coronary ultrasound measurements.

Methods and Results—IVUS studies using a 40-MHz transducer were performed in 35 patients with coronary artery disease. A total of 620 gray-scale images (310 pairs) were processed with and without the BNR, and lumen cross-sectional area (CSA) was determined by 2 independent observers. With the BNR, the intraobserver and interobserver correlation coefficients for lumen CSA were significantly improved (0.85 to 0.99 and 0.80 to 0.98, respectively). In the 270 images (135 pairs) in which vessel wall measurements were possible, the BNR significantly improved the intraobserver and interobserver correlation coefficients for plaque plus media CSA (0.83 to 0.99 and 0.76 to 0.97, respectively), whereas no influence was observed for external elastic membrane CSA (1.00 to 1.00 and 0.99 to 0.99, respectively).

Conclusions—This study demonstrates the feasibility of this novel algorithm to reduce blood noise, thereby enabling accurate lumen border delineation and providing reproducible measurements of both the lumen and plaque plus media CSAs. Incorporating a digital BNR may serve as an important adjunct to ultra–high-frequency IVUS imaging for improving accurate quantitative evaluation of vessel dimensions.


Key Words: ultrasonics • imaging • coronary disease




This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
G.-X. Yan, S. J. Rials, Y. Wu, T. Liu, X. Xu, R. A. Marinchak, and P. R. Kowey
Ventricular hypertrophy amplifies transmural repolarization dispersion and induces early afterdepolarization
Am J Physiol Heart Circ Physiol, November 1, 2001; 281(5): H1968 - H1975.
[Abstract] [Full Text] [PDF]