Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2001;103:1858-1862

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Soejima, K.
Right arrow Articles by Stevenson, W. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Soejima, K.
Right arrow Articles by Stevenson, W. G.
Related Collections
Right arrow Electrophysiology
Right arrow Ablation/ICD/surgery
Right arrow Arrhythmias, clinical electrophysiology, drugs

(Circulation. 2001;103:1858.)
© 2001 American Heart Association, Inc.


Clinical Investigation and Reports

Saline-Cooled Versus Standard Radiofrequency Catheter Ablation for Infarct-Related Ventricular Tachycardias

Kyoko Soejima, MD; Etienne Delacretaz, MD; Makoto Suzuki, MD; Corinna B. Brunckhorst, MD; William H. Maisel, MD; Peter L. Friedman, MD, PhD; William G. Stevenson, MD

From the Cardiovascular Division, Department of Internal Medicine, Brigham and Women’s Hospital, Harvard Medical School, Boston, Mass.

Correspondence to William G. Stevenson, MD, Cardiovascular Division, Brigham and Women’s Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115. E-mail wstevenson{at}rics.bwh.harvard.edu

Background—Saline cooling of the electrode during radiofrequency (RF) ablation increases lesion size in animal models. If cooled RF also increases lesion size in human infarcts, it should facilitate the termination of ventricular tachycardia (VT).

Methods and Results—In 66 patients with VT due to prior infarction, 366 ablation sites, which were classified by entrainment and isolated potentials followed by ablation during VT with either standard RF energy (247 sites) or cooled RF (119 sites), were retrospectively reviewed to compare the efficacy for terminating VT. RF energy was applied at 259 isthmus sites, 62 bystander sites, 28 inner loop sites, and 17 outer loop sites. Compared with standard RF, cooled RF terminated VT more frequently at isthmus sites where an isolated potential was present (89% versus 54%, P=0.003), isthmus sites without an isolated potential (36% versus 21%, P=0.04), and at inner loop sites (60% versus 22%, P=0.04). Termination rates were similarly low for cooled and standard RF at bystander sites (14% versus 9%, P=0.56) and outer loop sites (13% versus 11%, P=0.93).

Conclusions—Greater efficacy of cooled RF for terminating VT is consistent with the production of a larger lesion in human infarctions, which should facilitate successful ablation.


Key Words: tachycardia • ablation • reentry




This article has been cited by other articles:


Home page
EuropaceHome page
E. M. Aliot, W. G. Stevenson, J. M. Almendral-Garrote, F. Bogun, C. H. Calkins, E. Delacretaz, P. D. Bella, G. Hindricks, P. Jais, M. E. Josephson, et al.
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias: Developed in a partnership with the European Heart Rhythm Association (EHRA), a Registered Branch of the European Society of Cardiology (ESC), and the Heart Rhythm Society (HRS); in collaboration with the American College of Cardiology (ACC) and the American Heart Association (AHA)
Europace, June 1, 2009; 11(6): 771 - 817.
[Full Text] [PDF]


Home page
EuropaceHome page
M. Linhart, H. Mollnau, A. Bitzen, S. Wurtz, J. W. Schrickel, R. Andrie, F. Stockigt, C. Weiss, G. Nickenig, L. M. Lickfett, et al.
In vitro comparison of platinum-iridium and gold tip electrodes: lesion depth in 4 mm, 8 mm, and irrigated-tip radiofrequency ablation catheters
Europace, May 1, 2009; 11(5): 565 - 570.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
W. G. Stevenson, D. J. Wilber, A. Natale, W. M. Jackman, F. E. Marchlinski, T. Talbert, M. D. Gonzalez, S. J. Worley, E. G. Daoud, C. Hwang, et al.
Irrigated Radiofrequency Catheter Ablation Guided by Electroanatomic Mapping for Recurrent Ventricular Tachycardia After Myocardial Infarction: The Multicenter Thermocool Ventricular Tachycardia Ablation Trial
Circulation, December 16, 2008; 118(25): 2773 - 2782.
[Abstract] [Full Text] [PDF]


Home page
Circ Arrhythm ElectrophysiolHome page
F. Sacher, U. B. Tedrow, M. E. Field, J.-M. Raymond, B. A. Koplan, L. M. Epstein, and W. G. Stevenson
Ventricular Tachycardia Ablation: Evolution of Patients and Procedures Over 8 Years
Circ Arrhythm Electrophysiol, August 1, 2008; 1(3): 153 - 161.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
H. Calkins, J. Brugada, D. L. Packer, R. Cappato, S.-A. Chen, H. J.G. Crijns, R. J. Damiano Jr, D. W. Davies, D. E. Haines, M. Haissaguerre, et al.
HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Personnel, Policy, Procedures and Follow-Up: A report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation Developed in partnership with the European Heart Rhythm Association (EHRA) and the European Cardiac Arrhythmia Society (ECAS); in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), and the Society of Thoracic Surgeons (STS). Endorsed and Approved by the governing bodies of the American College of Cardiology, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, and the Heart Rhythm Society.
Europace, June 1, 2007; 9(6): 335 - 379.
[Full Text] [PDF]


Home page
CirculationHome page
W. G. Stevenson and K. Soejima
Catheter Ablation for Ventricular Tachycardia
Circulation, May 29, 2007; 115(21): 2750 - 2760.
[Full Text] [PDF]


Home page
EuropaceHome page
M. Volkmer, F. Ouyang, F. Deger, S. Ernst, M. Goya, D. Bansch, K. Berodt, K.-H. Kuck, and M. Antz
Substrate mapping vs. tachycardia mapping using CARTO in patients with coronary artery disease and ventricular tachycardia: impact on outcome of catheter ablation.
Europace, November 1, 2006; 8(11): 968 - 976.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
K. Soejima and W. G. Stevenson
Ventricular Tachycardia Associated With Myocardial Infarct Scar: A Spectrum of Therapies for a Single Patient
Circulation, July 9, 2002; 106(2): 176 - 179.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. K. Triedman, M. E. Alexander, B. A. Love, K. K. Collins, C. I. Berul, L. M. Bevilacqua, and E. P. Walsh
Influence of patient factors and ablative technologies on outcomes of radiofrequency ablation of intra-atrial re-entrant tachycardia in patients with congenital heart disease
J. Am. Coll. Cardiol., June 5, 2002; 39(11): 1827 - 1835.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
R.J. Schilling
Can catheter ablation cure post-infarction ventricular tachycardia?
Eur. Heart J., March 1, 2002; 23(5): 352 - 354.
[Full Text] [PDF]


Home page
Journal Watch CardiologyHome page
New Form of RF Catheter Ablation for VT Patients with Prior MI
Journal Watch Cardiology, July 6, 2001; 2001(706): 11 - 11.
[Full Text]