Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2002;105:1995-1999
Published online before print April 1, 2002, doi: 10.1161/01.CIR.0000014972.94443.EF
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
105/16/1995    most recent
01.CIR.0000014972.94443.EFv1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pitton, M. B.
Right arrow Articles by Thelen, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pitton, M. B.
Right arrow Articles by Thelen, M.
Related Collections
Right arrow Secondary prevention
Right arrow Cardiovascular imaging agents/Techniques
Right arrow Animal models of human disease
Right arrow Imaging
Right arrow Other Treatment
Right arrow CT and MRI
Right arrow CV surgery: aortic and vascular disease
Right arrow Other Vascular biology
Right arrow Other Research

(Circulation. 2002;105:1995.)
© 2002 American Heart Association, Inc.


Basic Science Reports

Endovascular Aneurysm Repair

Magnetic Resonance Monitoring of Histological Organization Processes in the Excluded Aneurysm

Michael Bernhard Pitton, MD; Ralf Patrick Schmenger, MD; Achim Neufang, MD; Moritz Anton Konerding, MD; Christoph Düber, MD; Manfred Thelen, MD

From the Departments of Radiology (M.B.P., R.P.S., M.T.), Cardiovascular Surgery (A.N.), and Anatomy (M.A.K.), University Hospital, Johannes Gutenberg University of Mainz, Germany, and Department of Radiology (C.D.), University Hospital Mannheim, Ruprecht-Karls University of Heidelberg, Germany.

Correspondence to PD Dr Michael B. Pitton, Department of Radiology, University Hospital, Langenbeckstraße 1, 55101 Mainz, Germany. E-mail pitton{at}radiologie.klinik.uni-mainz.de

Background The purpose of the present study was to systematically analyze the histopathologic organization processes in excluded aneurysms after endovascular stenting and to develop a noninvasive monitoring method for these processes using MRI.

Methods and Results In 36 mongrel dogs, autologous aortic aneurysms were created. Endovascular treatment was performed using covered stents. Follow-up was after 1 week, 6 weeks, and 6 months. MRI was performed with T2-weighted turbo-spin-echo sequences and T1-weighted spin-echo sequences and was repeated after contrast bolus with gadolinium. Histopathologic findings were correlated to signal intensities (SIs) of MRI images. SIs of distinct areas were analyzed and related to the SI of the reference tissue (SI ratio). The histological organization process was gradated in the following 4 classes: class 0, detritus without organization; classes I and II, connective tissue proliferation with increasing fiber synthesis; and class III, dense fibrous connective tissue. The SI ratios of T2-weighted images were significantly reduced from 4.76 in detritus (0) to 1.70 in dense fibrous connective tissue (III) as a function of histopathologic classes. SI ratios of T1-weighted images were reduced from 1.84 (0) to 1.12 (III). Contrast bolus with gadolinium-DTPA showed no change of SI ratio in detritus (0.99) but an increase from 1.12 (I) to 1.70 (III) as organization increased.

Conclusions The histological organization of excluded aneurysms can be monitored by MRI. Progressive organization is indicated by decreasing SIs in T2- and an increasing signal increase in T1-weighted images after gadolinium bolus.


Key Words: aneurysm • grafting • stents • magnetic resonance imaging • aorta




This article has been cited by other articles:


Home page
CirculationHome page
M. Kajimoto, T. Shimono, K. Hirano, Y. Miyake, Y. Sawada, N. Kato, H. Hirata, K. Imanaka-Yoshida, M. Nishikawa, T. Yoshida, et al.
Development of a New Method for Endovascular Aortic Repair: Combination Therapy of Cell Transplantation and Stent Grafts With a Drug Delivery System
Circulation, July 4, 2006; 114(1_suppl): I-378 - I-383.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. B. Pitton, H. Schweitzer, S. Herber, W. Schmiedt, A. Neufang, P. Kalden, M. Thelen, and C. Duber
MRI Versus Helical CT for Endoleak Detection After Endovascular Aneurysm Repair
Am. J. Roentgenol., November 1, 2005; 185(5): 1275 - 1281.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. H. Yamani, R. C. Starling, D. J. Cook, E. M. Tuzcu, A. Abdo, P. Paul, K. Powell, N. B. Ratliff, Y. Yu, P. M. McCarthy, et al.
Donor Spontaneous Intracerebral Hemorrhage Is Associated With Systemic Activation of Matrix Metalloproteinase-2 and Matrix Metalloproteinase-9 and Subsequent Development of Coronary Vasculopathy in the Heart Transplant Recipient
Circulation, October 7, 2003; 108(14): 1724 - 1728.
[Abstract] [Full Text] [PDF]