| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
(Circulation. 2004;110:2988-2995.)
© 2004 American Heart Association, Inc.
Arrhythmia/Electrophysiology |
From the Division of Cardiovascular Disease, Department of Internal Medicine, Mayo Clinic, Rochester, Minn.
Correspondence to Douglas L. Packer, MD, Heart Rhythm Services, Mayo Clinic, St. Marys Hospital, 1216 2nd St SW, AL 2-416, Rochester, MN 55902. E-mail packer.douglas{at}mayo.edu
Received March 31, 2004; revision received June 16, 2004; accepted June 21, 2004.
Background Many ablative approaches in or near the orifice of the pulmonary vein (PV) have demonstrated success in eliminating atrial fibrillation. Despite current practice, there are no data regarding the in vivo efficacy and safety of an 8-mm catheter tip for ablation at the PV orifice.
Methods and Results Ten mongrel dogs were studied. Thermocouples were implanted in the atrial muscle of the PV orifice. Intracardiac echocardiography monitored catheter position, tip/tissue orientation, and microbubble formation. Ninety-four ablations were performed for 120 seconds. A temperature discrepancy >10°C between the catheter tip and tissue occurred during 47 (50%) of the ablations. Despite termination of energy delivery, the average tissue temperature remained within 1°C of the achieved steady state for 9 seconds. A temperature discrepancy >10°C was more common in the right superior PV, with oblique catheter positioning, when tissue temperatures were >60°C or 80°C, and with type 1 or type 2 microbubble formation. However, microbubbles were not present in 7 (13%, type 1) and 10 (40%, type 2) ablations with tissue temperatures >80°C. The maximum tissue temperature achieved with nonfull-thickness lesions was 47.3±7.4°C vs 75.9±11.7°C (P<0.0001) for full-thickness lesions.
Conclusions Marked discrepancies between catheter-tip and tissue temperatures occurred with higher temperatures, prolonged ablation times, and unfavorable catheter thermistortissue contact. Also, these data suggest a conservative approach to atrial ablation, because full-thickness lesions were obtained when tissue temperatures reached 50°C to 60°C and the tissue retained high heat levels despite termination of radiofrequency energy. Finally, microbubbles are inconsistent markers of tissue overheating.
Key Words: catheter ablation myocardium temperature veins fibrillation
This article has been cited by other articles:
![]() |
M. Schmidt, G. Nolker, H. Marschang, K.-J. Gutleben, V. Schibgilla, H. Rittger, A.-M. Sinha, G. Ritscher, D. Mayer, J. Brachmann, et al. Incidence of oesophageal wall injury post-pulmonary vein antrum isolation for treatment of patients with atrial fibrillation Europace, February 1, 2008; 10(2): 205 - 209. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Calkins, J. Brugada, D. L. Packer, R. Cappato, S.-A. Chen, H. J.G. Crijns, R. J. Damiano Jr, D. W. Davies, D. E. Haines, M. Haissaguerre, et al. HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Personnel, Policy, Procedures and Follow-Up: A report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation Developed in partnership with the European Heart Rhythm Association (EHRA) and the European Cardiac Arrhythmia Society (ECAS); in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), and the Society of Thoracic Surgeons (STS). Endorsed and Approved by the governing bodies of the American College of Cardiology, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, and the Heart Rhythm Society. Europace, June 1, 2007; 9(6): 335 - 379. [Full Text] [PDF] |
||||
![]() |
H. Oral and F. Morady Radiofrequency energy delivery for pulmonary vein isolation: is less more? Europace, November 1, 2006; 8(11): 966 - 967. [Full Text] [PDF] |
||||
![]() |
T. J. Bunch, S. Mahapatra, G. K. Bruce, S. B. Johnson, D. V. Miller, B. D. Horne, X.-L. Wang, H.-C. Lee, N. M. Caplice, and D. L. Packer Impact of Transforming Growth Factor-{beta}1 on Atrioventricular Node Conduction Modification by Injected Autologous Fibroblasts in the Canine Heart Circulation, May 30, 2006; 113(21): 2485 - 2494. [Abstract] [Full Text] [PDF] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2004 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |