Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2004;110:515-521
Published online before print July 26, 2004, doi: 10.1161/01.CIR.0000137821.94074.EE
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
110/5/515    most recent
01.CIR.0000137821.94074.EEv1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Angelini, A.
Right arrow Articles by Chierchia, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Angelini, A.
Right arrow Articles by Chierchia, S.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*Angina
*Angioplasty
Related Collections
Right arrow Catheter-based coronary and valvular interventions: other
Right arrow Catheter-based coronary interventions: stents
Right arrow Acute coronary syndromes
Right arrow Chronic ischemic heart disease

(Circulation. 2004;110:515-521.)
© 2004 American Heart Association, Inc.


Original Articles

Distal Protection With a Filter Device During Coronary Stenting in Patients With Stable and Unstable Angina

Annalisa Angelini, MD; Paolo Rubartelli, MD; Flavio Mistrorigo, MD; Mila Della Barbera, BSc; Francesco Abbadessa, MD; Massimo Vischi, MD; Gaetano Thiene, MD, FRCP; Sergio Chierchia, MD

From the Department of Pathology, University of Padua Medical School, Padua (A.A., F.M., M.D.B., G.T.), and the Cardiology Division, San Martino Hospital, Genoa (P.R., F.A., M.V., S.C.), Italy.

Correspondence to Gaetano Thiene, MD, Department of Pathology, University of Padua Medical School, Via A. Gabelli, 61, 35121 Padua, Italy. E-mail cardpath{at}unipd.it

Received October 29, 2003; de novo received February 13, 2004; revision received April 29, 2004; accepted April 30, 2004.

Background— Filter protection after percutaneous coronary intervention (PCI) is now available to prevent distal embolization. The aims of this study were (1) to evaluate the microembolization phenomenon during procedures of stent implantation in native coronary arteries of patients with stable and unstable angina, (2) to assess the amount and characteristics of the debris captured by the Angioguard, and (3) to investigate the relation between clinical and angiographic variables and pathological data.

Methods and Results— Elective coronary stenting with the use of a protective filter was attempted in 39 consecutive coronary artery lesions with >60% stenosis (mean, 67.6±8.79%). Debris was present in 75.6% of the filters. Particle size ranged from 47.16 to 2503.48 µm (mean, 518.83±319.61 µm) in the major axis. Particles >300 µm were found in 24 of 28 filters with debris (85.7%), and particles >1000 µm were present in 10 of 28 filters (35.7%). Patients with unstable angina had greater particles (mean maximum longitudinal diameter, 1098.33±714.3 µm) than those with stable angina (412.91±453 µm; P<0.001). The presence of unstable angina (OR, 65; CI, 1.2 to 3420; P=0.03) and age >67 years (OR, 42; CI, 1 to 1698; P=0.04) were found to be the only independent predictors of embolic particle size.

Conclusions— By limiting embolization, protective devices may prevent a number of potentially unfavorable events, thereby improving outcome. Our data support the use of these devices, especially in lesions with higher embolic potential, such as those occurring in older patients and in those with unstable angina.


Key Words: angioplasty • stents • embolism • pathology • coronary disease




This article has been cited by other articles:


Home page
CirculationHome page
G. Heusch, P. Kleinbongard, D. Bose, B. Levkau, M. Haude, R. Schulz, and R. Erbel
Coronary Microembolization: From Bedside to Bench and Back to Bedside
Circulation, November 3, 2009; 120(18): 1822 - 1836.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol IntvHome page
C. Di Mario and G. Ferrante
Embolization: The "Dark Side" of Percutaneous Coronary Interventions
J. Am. Coll. Cardiol. Intv., June 1, 2008; 1(3): 277 - 278.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. K. Shah
Distal Embolization After Percutaneous Coronary Interventions: Prediction, Prevention, and Relevance
J. Am. Coll. Cardiol., October 23, 2007; 50(17): 1647 - 1648.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
T. Kawamoto, H. Okura, Y. Koyama, I. Toda, H. Taguchi, K. Tamita, A. Yamamuro, Y. Yoshimura, Y. Neishi, E. Toyota, et al.
The Relationship Between Coronary Plaque Characteristics and Small Embolic Particles During Coronary Stent Implantation
J. Am. Coll. Cardiol., October 23, 2007; 50(17): 1635 - 1640.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
A. Angelini, M. Della Barbera, and G. Thiene
Interventional procedures for atherothrombosis: pathology of retrieved material
Heart, October 1, 2007; 93(10): 1301 - 1308.
[Full Text] [PDF]


Home page
CirculationHome page
P. Bahrmann, G. S. Werner, G. Heusch, M. Ferrari, T. C. Poerner, A. Voss, and H. R. Figulla
Detection of Coronary Microembolization by Doppler Ultrasound in Patients With Stable Angina Pectoris Undergoing Elective Percutaneous Coronary Interventions
Circulation, February 6, 2007; 115(5): 600 - 608.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
I. Porto, J. B. Selvanayagam, W. J. Van Gaal, F. Prati, A. Cheng, K. Channon, S. Neubauer, and A. P. Banning
Plaque Volume and Occurrence and Location of Periprocedural Myocardial Necrosis After Percutaneous Coronary Intervention: Insights From Delayed-Enhancement Magnetic Resonance Imaging, Thrombolysis in Myocardial Infarction Myocardial Perfusion Grade Analysis, and Intravascular Ultrasound
Circulation, August 15, 2006; 114(7): 662 - 669.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
J. Herrmann
Peri-procedural myocardial injury: 2005 update
Eur. Heart J., December 1, 2005; 26(23): 2493 - 2519.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
Authors/Task Force Members, S. Silber, P. Albertsson, F. F. Aviles, P. G. Camici, A. Colombo, C. Hamm, E. Jorgensen, J. Marco, J.-E. Nordrehaug, et al.
Guidelines for Percutaneous Coronary Interventions: The Task Force for Percutaneous Coronary Interventions of the European Society of Cardiology
Eur. Heart J., April 2, 2005; 26(8): 804 - 847.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
C. M. Gibson, A. J. Kirtane, K. Boundy, H. Ly, D. Karmpaliotis, S. A. Murphy, R. P. Giugliano, C. P. Cannon, E. M. Antman, E. Braunwald, et al.
Association of a negative residual stenosis following rescue/adjunctive percutaneous coronary intervention with impaired myocardial perfusion and adverse outcomes among ST-segment elevation myocardial infarction patients
J. Am. Coll. Cardiol., February 1, 2005; 45(3): 357 - 362.
[Abstract] [Full Text] [PDF]