Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2006;113:1723-1729
Published online before print April 3, 2006, doi: 10.1161/CIRCULATIONAHA.105.596593
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
113/14/1723    most recent
CIRCULATIONAHA.105.596593v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pérez, F. J.
Right arrow Articles by Schubert, C. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pérez, F. J.
Right arrow Articles by Schubert, C. M.
Related Collections
Right arrow Arrythmias-basic studies
Right arrow Ablation/ICD/surgery

(Circulation. 2006;113:1723-1729.)
© 2006 American Heart Association, Inc.


Arrhythmia/Electrophysiology

Effects of Gap Geometry on Conduction Through Discontinuous Radiofrequency Lesions

Francisco J. Pérez, MD; Mark A. Wood, MD; Christine M. Schubert, PhD

From the Department of Cardiology (F.J.P., M.A.W.) and Department of Biostatistics (C.M.S.), Virginia Commonwealth University Medical Center, Richmond, Va.

Correspondence to Mark Wood, MD, Box 980053, Virginia Commonwealth University Medical Center, Richmond, VA, 23298-0053. E-mail mwoodmd{at}pol.net

Received October 20, 2005; revision received January 27, 2006; accepted February 3, 2006.

Background— Gaps of sufficient cross-sectional dimensions within linear radiofrequency (RF) lesions may allow conduction through the lesion. The purpose of this study was to examine the effects of different gap geometries on conduction through discontinuous RF lesions.

Methods and Results— Radiofrequency lesions were created in isolated, perfused rabbit right ventricular (RV) free wall preparations to produce gaps with 3 different lesion geometries: straight, bifurcated, and angled (n=10 each group). Angled preparations contained 2 right angles within the conduction path. Optical mapping was used to assess bidirectional conduction through the myocardium before and after gap formation during pacing at 1000-, 400-, and 200-ms cycle lengths. Histological analysis was performed on each preparation after optical mapping. After lesion formation, 9 of 10 straight gap preparations and 1 of 10 angled gap preparations demonstrated bidirectional conduction (P<0.001) at all cycle lengths. Nine of 10 bifurcated gap preparations demonstrated bidirectional conduction and 1 demonstrated unidirectional conduction at all cycle lengths. Two bifurcated gap preparations showed rate-dependent unidirectional 2:1 conduction. All unidirectional and rate-dependent block occurred during impulse propagation in the direction of diverging arms of the bifurcation. The occurrence of bidirectional conduction in the gaps was associated with the gap geometry (P<0.0001). Histological analysis confirmed the continuity of viable myocardium transmurally throughout the length of the gap in each preparation. The sites of conduction block were demonstrated to be just after the first angle in the conduction path for angled gaps and at the branch point of a bifurcated gap. The predominant myofiber orientation was changed relative to the conduction path at angulations of the gaps. Flecainide (0.1 µmol/L) produced bidirectional conduction block in straight and bifurcated gap preparations with bidirectional conduction at baseline.

Conclusions— Conduction through discontinuities in RF lesions is associated with gap geometry. Complex gap geometry may allow for unidirectional and/or rate-dependent block. Gaps within RF lesions are susceptible to pharmacological blockade.


 

CLINICAL PERSPECTIVE




This article has been cited by other articles:


Home page
Circ Arrhythm ElectrophysiolHome page
Y. Khaykin, A. Skanes, J. Champagne, S. Themistoclakis, L. Gula, A. Rossillo, A. Bonso, A. Raviele, C. A. Morillo, A. Verma, et al.
A Randomized Controlled Trial of the Efficacy and Safety of Electroanatomic Circumferential Pulmonary Vein Ablation Supplemented by Ablation of Complex Fractionated Atrial Electrograms Versus Potential-Guided Pulmonary Vein Antrum Isolation Guided by Intracardiac Ultrasound
Circ Arrhythm Electrophysiol, October 1, 2009; 2(5): 481 - 487.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. Castella, A. Garcia-Valentin, D. Pereda, A. Colli, A. Martinez, D. Martinez, J. Ramirez, and J. Mulet
Anatomic aspects of the atrioventricular junction influencing radiofrequency Cox maze IV procedures.
J. Thorac. Cardiovasc. Surg., August 1, 2008; 136(2): 419 - 423.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
F. G. Cosio, E. Aliot, G. L. Botto, H. Heidbuchel, C. J. Geller, P. Kirchhof, J.-C. De Haro, R. Frank, J. P. Villacastin, J. Vijgen, et al.
Delayed rhythm control of atrial fibrillation may be a cause of failure to prevent recurrences: reasons for change to active antiarrhythmic treatment at the time of the first detected episode
Europace, January 1, 2008; 10(1): 21 - 27.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
D. G. Katritsis and A. J. Camm
Catheter ablation of atrial fibrillation: do we know what we are doing?
Europace, November 1, 2007; 9(11): 1002 - 1005.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. Chae, H. Oral, E. Good, S. Dey, A. Wimmer, T. Crawford, D. Wells, J.-F. Sarrazin, N. Chalfoun, M. Kuhne, et al.
Atrial Tachycardia After Circumferential Pulmonary Vein Ablation of Atrial Fibrillation: Mechanistic Insights, Results of Catheter Ablation, and Risk Factors for Recurrence
J. Am. Coll. Cardiol., October 30, 2007; 50(18): 1781 - 1787.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. P. Daubert
Iatrogenic Left Atrial Tachycardias: Where Are We?
J. Am. Coll. Cardiol., October 30, 2007; 50(18): 1788 - 1790.
[Full Text] [PDF]