(Circulation. 2007;115:84-93.)
© 2007 American Heart Association, Inc.
Imaging |
From the Division of Hemostasis and Thrombosis (R.F., G.J.G.), the Division of Hematology/Oncology (E.T., A.M.D.G., R.G.L., J.V.F.), and the Department of Radiology (J.V.F.), Beth Israel Deaconess Medical Center, and the Cardiovascular Research Center (K.H., R.J.H.), Massachusetts General Hospital, Boston, Mass.
Correspondence to Robert Flaumenhaft, MD, PhD, Division of Hemostasis and Thrombosis, Beth Israel Deaconess Medical Center, 330 Brookline Ave, Boston, MA 02215. E-mail rflaumen{at}bidmc.harvard.edu
Received June 5, 2006; accepted October 24, 2006.
Background Imaging of thrombus formation in vivo has been limited by the inability to directly visualize and measure thrombi in large blood vessels in real time. Near-infrared light, with its superior tissue penetration and reduced scatter, could potentially solve this problem.
Methods and Results Platelets were labeled with the near-infrared fluorophore IR-786. Optimal total fluorescence yield occurred at 6 attomoles of IR-786 per platelet. IR-786labeled platelets were tested for their ability to detect thrombus formation in large animal model systems relevant to common human vascular procedures. Invisible near-infrared light did not distort the surgical field in any way, and even after optimization of per-platelet fluorescent yield, platelets remained fully functional. Intravenous infusion of just 3.6x1010 labeled platelets into a 35-kg Yorkshire pig permitted thrombus visualization, with a signal-to-background ratio
2, for at least 2 hours in coronary, carotid, and femoral vessels. Platelet-rich, actively growing clots were monitored in real time and quantified with respect to size and kinetics after injury to vessels, cutaneous incisions, intravascular stent insertion, or introduction of embolic coils. Similarly, formed clots were monitored in real time during thrombolysis with streptokinase and heparin. Vessel patency was assessed independently with a second near-infrared fluorescent blood pool agent.
Conclusions IR-786labeled platelets provide sensitive, specific, and real-time visualization of thrombi in thick-walled blood vessels. In addition to immediate application in cardiac, transplant, and vascular surgery, the mechanisms that underlie thrombus formation in large blood vessels can now be investigated.
Related Article:
This article has been cited by other articles:
![]() |
F. Prunier, Y. Kawase, D. Gianni, C. Scapin, S. B. Danik, P. T. Ellinor, R. J. Hajjar, and F. del Monte Prevention of Ventricular Arrhythmias With Sarcoplasmic Reticulum Ca2+ ATPase Pump Overexpression in a Porcine Model of Ischemia Reperfusion Circulation, August 5, 2008; 118(6): 614 - 624. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. von zur Muhlen, D. von Elverfeldt, J.A. Moeller, R.P. Choudhury, D. Paul, C.E. Hagemeyer, M. Olschewski, A. Becker, I. Neudorfer, N. Bassler, et al. Magnetic Resonance Imaging Contrast Agent Targeted Toward Activated Platelets Allows In Vivo Detection of Thrombosis and Monitoring of Thrombolysis Circulation, July 15, 2008; 118(3): 258 - 267. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Sanz, P. R. Moreno, and V. Fuster The year in atherothrombosis. J. Am. Coll. Cardiol., March 4, 2008; 51(9): 944 - 955. [Full Text] [PDF] |
||||
![]() |
R. J. Westrick, M. E. Winn, and D. T. Eitzman Murine Models of Vascular Thrombosis Arterioscler. Thromb. Vasc. Biol., October 1, 2007; 27(10): 2079 - 2093. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. V. Denis and D. D. Wagner Platelet Adhesion Receptors and Their Ligands in Mouse Models of Thrombosis Arterioscler. Thromb. Vasc. Biol., April 1, 2007; 27(4): 728 - 739. [Abstract] [Full Text] [PDF] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2007 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |