Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1965;32:386-393

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by LANGENDORF, R.
Right arrow Articles by KATZ, L. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by LANGENDORF, R.
Right arrow Articles by KATZ, L. N.

(Circulation. 1965;32:386.)
© 1965 American Heart Association, Inc.


Experimental Demonstration of Concealed AV Conduction in the Human Heart

R. LANGENDORF M.D.1; A. PICK M.D.1; A. EDELIST M.D.1; L. N. KATZ M.D.1

1 From the Cardiovascular Institute, Michael Reese Hospital and Medical Center, Chicago, Illinois.

Artificial pacing of patients with Stokes-Adams disease provided an opportunity to study experimentally the ways of operation of concealed antegrade or retrograde conduction, or both, in the AV junction.

With a catheter electrode in the right atrium the classical experiment of Lewis and Master was repeated, revealing, during a 2:1 ventricular response to an atrial tachycardia, the delaying effect of seemingly blocked atrial impulses on subsequent AV conduction.

Shifting the position of a single premature atrial impulse within a constant driving cycle of the atria produced graded effects of "blocked" atrial impulses on AV junctional refractoriness, permitting an estimation of the duration of the "phase of concealed AV conduction."

Interpolation of such premature atrial impulses into successive driving cycles resulted in "repetitive concealed conduction."

In an artificially produced atrial parasystole there was observed "concealed discharge" of a subsidiary (escaping) AV junctional pacemaker by an apparently nonconducted atrial impulse.

With a catheter electrode in the right ventricle in a case of advanced AV block, concealed retrograde conduction of pacer stimuli disturbed the rhythmicity of a spontaneous AV junctional pacemaker.

In a case of advanced AV block with preserved retrograde conduction (unidirectional block), evidence of penetration of the upper AV junction by the "blocked" antegrade impulse was found.

With electrodes implanted in the left ventricle in a case of advanced AV block, concealed retrograde conduction of the artificial pacemaker stimuli enhanced antegrade conduction by transiently changing an area of unidirectional block to one of supernormal conduction.

Thus, all known manifestations of concealed atrioventricular and ventriculo-atrial conduction, occurring spontaneously in clinical records or induced in animal experiments, were artificially reproduced in the human heart.




This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
R. S. T. Leung, M. E. Bowman, T. M. Diep, G. Lorenzi-Filho, J. S. Floras, and T. D. Bradley
Influence of Cheyne-Stokes respiration on ventricular response to atrial fibrillation in heart failure
J Appl Physiol, November 1, 2005; 99(5): 1689 - 1696.
[Abstract] [Full Text] [PDF]