Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1969;39:I-207-I-213

This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by HIGHTOWER, B. M.
Right arrow Articles by KIRKLIN, J. W.
Right arrow Search for Related Content
PubMed
Right arrow Articles by HIGHTOWER, B. M.
Right arrow Articles by KIRKLIN, J. W.

(Circulation. 1969;39:I-207.)
© 1969 American Heart Association, Inc.


Double-Outlet Right Ventricle with Transposed Great Arteries and Subpulmonary Ventricular Septal Defect

The Taussig-Bing Malformation

BILLY M. HIGHTOWER M.D.1; ALBERTO BARCIA M.D.1; LIONEL M. BARGERON JR. M.D.1; JOHN W. KIRKLIN M.D.1

1 From the Departments of Surgery, Radiology, and Pediatrics, University of Alabama Medical Center, Birmingham, Alabama.

The angiocardiographic findings and successful surgical treatment of three patients with double-outlet right ventricle, bilateral conus, transposition of the great arteries, subpulmonary ventricular septal defect, and pulmonary-mitral valve discontinuity are reported. The atria, viscera, and ventricles were normally located, and the aorta originated to the right and anterior to the pulmonary artery.

Surgical repair was accomplished by closure of the ventricular septal defect in such a way that left ventricular outflow was routed via a prosthetic tunnel to the pulmonary artery. Then systemic venous return was transposed intra-atrially by the Mustard technique.

All patients survived complete repair and have continued to improve over a period ranging from several months to 1 year after operation. In one patient complete heart block developed postoperatively, necessitating the insertion of a permanent electronic pacemaker. Details of the method of repair and preoperative studies are presented.