Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1969;40:863-870

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by SHAPIRO, W.
Right arrow Articles by CHAWLA, N. P. S.
Right arrow Search for Related Content
PubMed
Right arrow Articles by SHAPIRO, W.
Right arrow Articles by CHAWLA, N. P. S.

(Circulation. 1969;40:863.)
© 1969 American Heart Association, Inc.


Observations on the Regulation of Cerebral Blood Flow in Complete Heart Block

WILLIAM SHAPIRO M.D.1 N. P. S. CHAWLA M. B.1

1 From the Departments of Medicine, Veterans Administration Hospital and the University of Texas Southwestern Medical School, Dallas, Texas.

The simultaneous effects of right ventricular pacing on cerebral blood flow (CBF) and cardiac function in complete heart block have not been reported. Catheters in the jugular bulb, right ventricle, and pulmonary and brachial arteries of five patients, aged 49 to 78 years, allowed studies at initial rates of 30 to 40 and during the tenth minute of pacing at 60, 70, 90, and 100 per minute. Mean initial cardiac output (CO) was 2.8 L per minute and increased 29% to 3.6 at a rate of 60 per minute (P<0.01). Simultaneous mean control CBF was also low, but rose to 118% of control with pacing (P<0.05). Systemic, cerebral, and pulmonary vascular resistances declined with these increases in flow as the elevated mean venous and arterial pressures remained stable. Mean arterial oxygen and carbon dioxide tensions and pH were normal at all rates. The parameters measured were not materially altered by pacing at rates above 60 per minute. The changes in CBF were well correlated with those of CO (r=0.81, P<0.01) and unrelated to simultaneous mean arterial or cerebral perfusion pressures. The alterations in CO were also unrelated to these pressures. The data clearly demonstrate a disturbance in CBF autoregulation, which may be a function of the low CO state.


Key Words: Circulatory dynamics during pacing • Cerebral perfusion pressure • Cerebral blood flow equivalent • Blood gas • pH