Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1973;47:341-352

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by MORRISON, J.
Right arrow Articles by KILLIP, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by MORRISON, J.
Right arrow Articles by KILLIP, T.

(Circulation. 1973;47:341.)
© 1973 American Heart Association, Inc.


Serum Digitalis and Arrhythmia in Patients Undergoing Cardiopulmonary Bypass

JOHN MORRISON M.D.1 THOMAS KILLIP M.D.1

1 From the Division of Cardiology, Department of Medicine, Cornell University Medical College, New York, New York.

To assess the possible role of digitalis in the etiology of arrhythmia following cardiopulmonary bypass, serum digoxin or digitoxin was determined serially by radioimmunoassay in 24 chronically digitalized patients undergoing open-heart surgery. After an initial fall during bypass probably secondary to intraoperative fluid, serum digitalis rebounded, rising to or surpassing the preoperative value in 21 of the 24 patients studied. Peak rebound serum digitalis occurred an average of 13 hours following onset of bypass. Eight patients receiving maintenance digoxin developed arrhythmia postbypass at or near the peak of the rebound. The arrhythmia subsided as the peak was passed. Mean serum digoxin at the time of arrhythmia was 1.3 ± 0.2 (sd) ng/ml. A significantly higher (P < 0.001) value than the value of 0.07 ± 0.03 ng/ml found in patients without arrhythmia. Occurrence of arrhythmia could not be correlated with diagnosis, clinical status, cardiac size, blood gas, or serum electrolyte values. In 77 control subjects with ECG evidence of digoxin toxicity, mean serum digoxin level was 3.1 ± 0.9 (sd) ng/ml. Since arrhythmia occurred at serum levels of digitalis lower than those observed in patients toxic to the drug who had not undergone cardiopulmonary bypass, and since the arrhythmia subsided as the serum level declined, and since the levels were higher in patients who had arrhythmia postbypass than in those who did not, this study suggests that myocardial sensitivity to the toxic effects of digitalis is increased in the first 24 hours following cardiopulmonary bypass.


Key Words: Serum digoxin • Serum digitoxin • Digitalis toxicity • Open-heart surgery

Submitted on March 2, 1972
Accepted on October 23, 1972




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
S. C. Thomasset, S. L. Ong, and S. R. Large
Post-Coronary Artery Bypass Graft Liver Failure: A Possible Association With Leflunomide
Ann. Thorac. Surg., February 1, 2005; 79(2): 698 - 699.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
R. H. Goldman
The Use of Serum Digoxin Levels in Clinical Practice
JAMA, July 15, 1974; 229(3): 331 - 332.
[Abstract] [PDF]