Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1973;48:III-74-III-79

This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by O'ROURKE, R. A.
Right arrow Articles by BRAUNWALD, N. S.
Right arrow Search for Related Content
PubMed
Right arrow Articles by O'ROURKE, R. A.
Right arrow Articles by BRAUNWALD, N. S.

(Circulation. 1973;48:III-74.)
© 1973 American Heart Association, Inc.


Postoperative Hemodynamic Evaluation of a New Fabric-Covered Ball-Valve Prosthesis

ROBERT A. O'ROURKE M.D.1; KIRK L. PETERSON M.D.1; NINA S. BRAUNWALD M.D.1

1 From the Departments of Surgery and Medicine, University of California, San Diego, California.

Previous in vitro and in vivo experimental studies have indicated that insertion of the Braun-wald-Cutter fabric-covered ball-valve prosthesis results in negligible thromboembolic complications and hemodynamic performance comparable to that of noncovered mitral and aortic ball-valve prostheses. To assess the clinical efficacy of this fabric-covered valve prosthesis, 35 patients have been followed for 4 to 26 months (540 patient-months) after mitral and/or aortic valve replacement, and 13 have had extensive hemodynamic re-evaluation.

In eight patients with the mitral valve prosthesis, the mean diastolic gradient averaged 4.8 mm Hg (range 0 to 8) and the end-diastolic gradient 0.8 mm Hg (range 0 to 2) at a time when the mean heart rate was 75 beats/min (range 50 to 100) and the cardiac output averaged 5.1 L/min (range 3.4 to 8.0). The calculated effective mitral valve orifice size averaged 2.68 cm2 (range 1.92 to 3.46). In six patients with the aortic valve prosthesis, the average peak systolic gradient was 13 mm Hg (range 0 to 22), and the mean systolic gradient averaged 14.5 mm Hg (range 0 to 24) when the mean heart rate was 82 beats/min (range 64 to 120) and the cardiac output averaged 6.2 L/min (range 3.2 to 9.3). The average effective aortic valve size in the five patients with a mean systolic transvalvular gradient was 1.41 cm2 (range 1.26 to 1.62).

Only one postoperative thromboembolic complication has been observed, and this occurred in a patient with atrial fibrillation and a large left atrium three weeks after discontinuing anticoagulant therapy because of gingival bleeding.

These data indicate that use of the fabric-covered Braunwald-Cutter ball prosthesis produces few thromboembolic complications and a satisfactory hemodynamic result.


Key Words: Anticoagulants • Thromboembolism • Prosthetic heart valves • Valve replacement