Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1974;50:487-495

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by SPURRELL, R. A. J.
Right arrow Articles by SOWTON, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by SPURRELL, R. A. J.
Right arrow Articles by SOWTON, E.

(Circulation. 1974;50:487.)
© 1974 American Heart Association, Inc.


Retrograde Invasion of the Bundle Branches Producing Aberration of the QRS Complex During Supraventricular Tachycardia Studied by Programmed Electrical Stimulation

ROWORTHA A. J. SPURRELL M.D., M.R.C.P.1; DENNIS M. KRIKLER M.D., F.R.C.P., F.A.C.C.1; EDGAR SOWTON M.D., F.R.C.P., F.A.C.C.1

1 From the Department of Cardiology, Guy's Hospital, London, England.

Four patients with paroxysmal supraventricular tachycardia have been studied using programmed electrical stimulation of the heart and intracardiac recordings. One patient had an atrioventricular (A-V) junctional tachycardia, possibly due to a rapidly discharging protected ectopic focus, and three patients had anomalous atrioventricular connections. The ECG recordings in all four patients showed a bundle branch block pattern during tachycardia, and normal intraventricular conduction could be produced by suitably timed right ventricular premature beats. The cycle length of the tachycardia was shorter with normal intraventricular conduction than in the presence of a bundle branch block pattern in two patients. Evidence is presented indicating that the bundle branch block during tachycardia was likely to be due to concealed retrograde conduction of the appropriate bundle branch, and in the presence of an anomalous bypass, the cycle length of the tachycardia depended on the anatomical relationship of the anomalous bypass to the blocked bundle branch.


Key Words: Wolff-Parkinson-White Syndrome • Atrioventricular conduction • Fusion beats • Accessory pathways • Ectopic beats • Bundle branch block • Junctional rhythm

Submitted on May 7, 1973
Accepted on May 2, 1974




This article has been cited by other articles:


Home page
CirculationHome page
K. Hirao, K. Otomo, X. Wang, K. J. Beckman, J. H. McClelland, L. Widman, M. D. Gonzalez, M. Arruda, H. Nakagawa, R. Lazzara, et al.
Para-Hisian Pacing: A New Method for Differentiating Retrograde Conduction Over an Accessory AV Pathway From Conduction Over the AV Node
Circulation, September 1, 1996; 94(5): 1027 - 1035.
[Abstract] [Full Text]