1 From the Departments of Medicine (Cardiology), Radiology, and Surgery, University of Rochester School of Medicine and Dentistry, Rochester, New York.
Echocardiographic studies demonstrated the presence of co-existing idiopathic hypertrophic subaortic stenosis (IHSS) in six patients with aortic valve disease (four calcific aortic stenosis, two pure aortic incompetence). The characteristics of IHSS were a narrow left ventricular outflow tract, a systolic anterior movement of the mitral valve (SAM), and asymmetric ventricular septal hypertrophy. Large SAMs were observed in two patients with pure aortic incompetence and one with aortic stenosis. Relatively small, inconstant, and often incomplete SAMs were noted in the remaining three patients with aortic stenosis. In contrast to isolated IHSS, the small SAMs observed in this group did not become prominent with the Valsalva maneuver or amyl nitrite inhalation. These features may be related to the afterload provided by the fixed, distal stenosis. Echocardiographic evidence of aortic valve disease was present in all patients. Clinically, co-existence of IHSS was not suspected in five patients. Associated IHSS was established using provocative measures during cardiac catheterization in three cases, while in the remainder it was substantiated at surgery. Three of four patients who underwent myotomy/myectomy concomitant with aortic valve replacement survived and postoperative echocardiographic studies revealed complete absence of SAMs in two of them. Echocardiography appears to be useful in the diagnosis of associated IHSS in the presence of aortic valve disease.
Submitted on March 1, 1974
© 1974 American Heart Association, Inc.
Echocardiography in the Diagnosis of Idiopathic Hypertrophic Subaortic Stenosis Co-existing With Aortic Valve Disease
Key Words: Ultrasound Aortic incompetence Aortic valve stenosis Myotomy Myectomy SAM
Accepted on June 7, 1974
This article has been cited by other articles:
![]() |
J. Bartunek, S. U. Sys, A. C. Rodrigues, E. Van Schuerbeeck, L. Mortier, and B. de Bruyne Abnormal Systolic Intraventricular Flow Velocities After Valve Replacement for Aortic Stenosis : Mechanisms, Predictive Factors, and Prognostic Significance Circulation, February 15, 1996; 93(4): 712 - 719. [Abstract] [Full Text] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1974 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |