Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1974;50:956-961

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by DAHL, C. F.
Right arrow Articles by THOMAS, E. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by DAHL, C. F.
Right arrow Articles by THOMAS, E. D.

(Circulation. 1974;50:956.)
© 1974 American Heart Association, Inc.


Myocardial Necrosis from Direct Current Countershock

Effect of Paddle Electrode Size and Time Interval Between Discharges

CHARLES F. DAHL 1; GORDON A. EWY M.D.1; E. D. WARNER M.D.1; EVAN D. THOMAS 1

1 From the Departments of Medicine and Pathology, University of Arizona College of Medicine.

The effect of varying both paddle electrode size and the time interval between direct current countershock on myocardial necrosis was studied. Forty-two dogs were divided into seven groups of six dogs each. All dogs were given ten consecutive, 240 watt-second countershocks (delivered energy into a 50 ohm load). Three groups were shocked with paddle electrode diameters of 8.0 cm (standard electrodes), two groups with paddle electrode diameters of 12.8 cm (large electrodes), and two groups with paddle electrode diameters of 4.3 cm (small electrodes). The time intervals between discharges in the groups shocked with the standard electrodes were 15 seconds, one minute, and three minutes. The time interval between discharges in the groups shocked with small and large electrodes was 15 seconds and three minutes. Myocardial necrosis was quantitated by precordial electrocardiographic mapping recorded minutes after, and by gross and microscopic examination of the hearts four days after direct current countershock.

When the time interval between discharges was shorter, myocardial necrosis was greater. When the time interval between discharges was constant, more necrosis was produced with smaller-sized paddle electrodes. It is concluded that large paddle electrodes should be used for delivering direct current countershocks, and that during elective cardioversion, consecutive discharges should be delivered at time intervals greater than three minutes.


Key Words: Cardioversion • Defibrillation • Precordial electrocardiographic mapping

Submitted on June 25, 1973
Accepted on July 9, 1974




This article has been cited by other articles:


Home page
EuropaceHome page
Writing Committee Members, V. Fuster, L. E. Ryden, D. S. Cannom, H. J. Crijns, A. B. Curtis, K. A. Ellenbogen, J. L. Halperin, J.-Y. Le Heuzey, G. N. Kay, et al.
ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation: full text: A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation) Developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society
Europace, September 1, 2006; 8(9): 651 - 745.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
V. Fuster, L. E. Ryden, D. S. Cannom, H. J. Crijns, A. B. Curtis, K. A. Ellenbogen, J. L. Halperin, J.-Y. Le Heuzey, G. N. Kay, J. E. Lowe, et al.
ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation) Developed in Collaboration With the European Heart Rhythm Association and the Heart Rhythm Society
J. Am. Coll. Cardiol., August 15, 2006; 48(4): e149 - e246.
[Full Text] [PDF]


Home page
CirculationHome page
V. Fuster, L. E. Ryden, D. S. Cannom, H. J. Crijns, A. B. Curtis, K. A. Ellenbogen, J. L. Halperin, J.-Y. Le Heuzey, G. N. Kay, J. E. Lowe, et al.
ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation): Developed in Collaboration With the European Heart Rhythm Association and the Heart Rhythm Society
Circulation, August 15, 2006; 114(7): e257 - e354.
[Full Text] [PDF]


Home page
CirculationHome page
Part 5: Electrical Therapies: Automated External Defibrillators, Defibrillation, Cardioversion, and Pacing
Circulation, December 13, 2005; 112(24_suppl): IV-35 - IV-46.
[Full Text] [PDF]


Home page
CirculationHome page
Part 3: Defibrillation
Circulation, November 29, 2005; 112(22_suppl): III-17 - III-24.
[Full Text] [PDF]


Home page
CirculationHome page
J. J. Menegazzi, C. W. Callaway, L. D. Sherman, D. P. Hostler, H. E. Wang, K. C. Fertig, and E. S. Logue
Ventricular Fibrillation Scaling Exponent Can Guide Timing of Defibrillation and Other Therapies
Circulation, February 24, 2004; 109(7): 926 - 931.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
C. Waller, F. Callies, and H. Langenfeld
Adverse effects of direct current cardioversion on cardiac pacemakers and electrodes: Is external cardioversion contraindicated in patients with permanent pacing systems?
Europace, January 1, 2004; 6(2): 165 - 168.
[Abstract] [Full Text] [PDF]


Home page
PediatricsHome page
R. A. Samson, R. A. Berg, and R. Bingham
Use of Automated External Defibrillators for Children: An Update--An Advisory Statement From the Pediatric Advanced Life Support Task Force, International Liaison Committee on Resuscitation
Pediatrics, July 1, 2003; 112(1): 163 - 168.
[Full Text] [PDF]


Home page
CirculationHome page
R.A. Samson, R.A. Berg, R. Bingham, D. Biarent, A. Coovadia, M.F. Hazinski, R.W. Hickey, V. Nadkarni, G. Nichol, J. Tibballs, et al.
Use of Automated External Defibrillators for Children: An Update: An Advisory Statement From the Pediatric Advanced Life Support Task Force, International Liaison Committee on Resuscitation
Circulation, July 1, 2003; 107(25): 3250 - 3255.
[Full Text] [PDF]


Home page
Eur Heart JHome page
Guidelines for the management of patients with atrial fibrillation. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines and Policy Conferences (Committee to develop guidelines for the management of patients with atrial fibrillation) developed in collaboration with the North American Society of Pacing and Electrophysiology
Eur. Heart J., October 2, 2001; 22(20): 1852 - 1923.
[PDF]


Home page
J Am Coll CardiolHome page
V. Fuster, L. E. Ryden, R. W. Asinger, D. S. Cannom, H. J. Crijns, R. L. Frye, J. L. Halperin, G. N. Kay, W. W. Klein, S. Levy, et al.
ACC/AHA/ESC guidelines for the management of patients with atrial fibrillation: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines and Policy Conferences (Committee to Develop Guidelines for the Management of Patients With Atrial Fibrillation) Developed in Collaboration With the North American Society of Pacing and Electrophysiology
J. Am. Coll. Cardiol., October 1, 2001; 38(4): 1266 - 1266.
[Full Text] [PDF]


Home page
Eur Heart JHome page
D.A. Morrow and E.M. Antman
Cardiac marker elevation after cardioversion: sorting out chicken and egg
Eur. Heart J., February 1, 2000; 21(3): 171 - 173.
[PDF]


Home page
Eur Heart JHome page
M Lund, J.K French, R.N Johnson, B.F Williams, and H.D White
Serum troponins T and I after elective cardioversion
Eur. Heart J., February 1, 2000; 21(3): 245 - 253.
[Abstract] [PDF]


Home page
J Am Coll CardiolHome page
T. M. Hurst, M. Hinrichs, C. Breidenbach, N. Katz, and B. Waldecker
Detection of myocardial injury during transvenous implantation of automatic cardioverter-defibrillators
J. Am. Coll. Cardiol., August 1, 1999; 34(2): 402 - 408.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
L. A. Pagan-Carlo, L. A. Garcia, J. L. Hutchison, G. R. Buettner, and R. E. Kerber
Captopril Lowers Coronary Venous Free Radical Concentration After Direct Current Cardiac Shocks
Chest, August 1, 1999; 116(2): 484 - 487.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. E. Epstein, G. N. Kay, V. J. Plumb, S. M. Dailey, and P. G. Anderson
Gross and Microscopic Pathological Changes Associated With Nonthoracotomy Implantable Defibrillator Leads
Circulation, October 13, 1998; 98(15): 1517 - 1524.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. A. S. Cooper, V. J. Plumb, A. E. Epstein, G. N. Kay, and R. E. Ideker
Marked Reduction in Internal Atrial Defibrillation Thresholds With Dual-Current Pathways and Sequential Shocks in Humans
Circulation, June 30, 1998; 97(25): 2527 - 2535.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. A. S. Cooper, W. M. Smith, and R. E. Ideker
Internal Cardioversion of Atrial Fibrillation : Marked Reduction in Defibrillation Threshold With Dual Current Pathways
Circulation, October 21, 1997; 96(8): 2693 - 2700.
[Abstract] [Full Text]


Home page
CirculationHome page
J. Xie, M. H. Weil, S. Sun, W. Tang, Y. Sato, X. Jin, and J. Bisera
High-Energy Defibrillation Increases the Severity of Postresuscitation Myocardial Dysfunction
Circulation, July 15, 1997; 96(2): 683 - 688.
[Abstract] [Full Text]


Home page
CirculationHome page
R. A. S. Cooper, E. E. Johnson, and J. M. Wharton
Internal Atrial Defibrillation in Humans : Improved Efficacy of Biphasic Waveforms and the Importance of Phase Duration
Circulation, March 18, 1997; 95(6): 1487 - 1496.
[Abstract] [Full Text]


Home page
CirculationHome page
G. H. Bardy, F. E. Marchlinski, A. D. Sharma, S. J. Worley, R. M. Luceri, R. Yee, B. D. Halperin, C. L. Fellows, T. S. Ahern, D. A. Chilson, et al.
Multicenter Comparison of Truncated Biphasic Shocks and Standard Damped Sine Wave Monophasic Shocks for Transthoracic Ventricular Defibrillation
Circulation, November 15, 1996; 94(10): 2507 - 2514.
[Abstract] [Full Text]


Home page
CirculationHome page
E. U. Alt, P. C. Fotuhi, R. L. Callihan, E. Mestre, W. M. Smith, and R. E. Ideker
Endocardial Carbon-Braid Electrodes : A New Concept for Lower Defibrillation Thresholds
Circulation, September 15, 1995; 92(6): 1627 - 1633.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
E. Ovrum, G. Tangen, E. A. Holen, M.-A. L. Ringdal, and R. Istad
Conversion of Postischemic Ventricular Fibrillation With Intraaortic Infusion of Potassium Chloride
Ann. Thorac. Surg., July 1, 1995; 60(1): 156 - 159.
[Abstract] [Full Text]


Home page
CirculationHome page
G. H. Bardy, B. E. Gliner, P. J. Kudenchuk, J. E. Poole, G. L. Dolack, G. K. Jones, J. Anderson, C. Troutman, and G. Johnson
Truncated Biphasic Pulses for Transthoracic Defibrillation
Circulation, March 15, 1995; 91(6): 1768 - 1774.
[Abstract] [Full Text]


Home page
J Intensive Care MedHome page
R. L. Gold and J. C. Rios
Iatrogenic Cardiovascular Disease Secondary to Diagnostic and Therapeutic Procedures
J Intensive Care Med, January 1, 1987; 2(1): 49 - 60.
[Abstract] [PDF]