Circulation, Vol 54, 102-108, Copyright © 1976 by American Heart Association
L Frazin, JV Talano, L Stephanides, HS Loeb, L Kopel and RM Gunnar
Esophageal echocardiography has been developed for use in patients with
chronic obstructive pulmonary disease and is a safe diagnostic procedure
which provides high resolution mirror image echoes of many cardiac
structures. Conventional anterior and esophageal echocardiograms were
performed in 38 subjects. Esophageal echoes were of diagnostic quality in
all 38 subjects, anterior echoes were of diagnostic quality in only 18.
Measurements from anterior and esophageal echocardiograms correlated well
for aortic valve diameter (r = 0.87), left atrium diameter (r = 0.96),
mitral valve EF slope (r = 0.97) and less well for aortic root diameter (r
= 0.69).
ARTICLES
Esophageal echocardiography
This article has been cited by other articles:
![]() |
P. P Sengupta and B. K Khandheria Transoesophageal echocardiography Heart, April 1, 2005; 91(4): 541 - 547. [Full Text] [PDF] |
||||
![]() |
A. I. Obeid Transesophageal Echocardiography and Staging in Lung Cancer: A View From the Rear Window Chest, February 1, 2005; 127(2): 420 - 423. [Full Text] [PDF] |
||||
![]() |
J.-B. Liu and B. B. Goldberg Catheter-Based Intraluminal Sonography J. Ultrasound Med., February 1, 2004; 23(2): 145 - 160. [Full Text] [PDF] |
||||
![]() |
R. A. Meyer History of Ultrasound in Cardiology J. Ultrasound Med., January 1, 2004; 23(1): 1 - 11. [Full Text] [PDF] |
||||
![]() |
J.R.T.C. Roelandt Seeing the heart; the success story of cardiac imaging Eur. Heart J., August 2, 2000; 21(16): 1281 - 1288. [PDF] |
||||
![]() |
P. A. Tunick, G. A. Krinsky, V. S. Lee, and I. Kronzon Diagnostic Imaging of Thoracic Aortic Atherosclerosis Am. J. Roentgenol., April 1, 2000; 174(4): 1119 - 1125. [Full Text] [PDF] |
||||
![]() |
P. Couture, A. Y. Denault, S. McKenty, D. Boudreault, F. Plante, R. Perron, D. Babin, L. Normandin, and N. Poirier Impact of routine use of intraoperative transesophageal echocardiography during cardiac surgery Can J Anesth, January 1, 2000; 47(1): 20 - 26. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. A. Greene, J. A. Alexander, D. G. Knauf, J. Talbert, M. Langham, D. Kays, and D. Ledbetter Endoscopic Evaluation of the Esophagus in Infants and Children Immediately Following Intraoperative Use of Transesophageal Echocardiography Chest, November 1, 1999; 116(5): 1247 - 1250. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Morris, P. L. Klineberg, R. Chard, V. Hanrahan, K. Harrison, G. Larcos, Y. Mudaliar, W. Meldrum Hanna, H. Paterson, and D. Shaw Establishment and First Audit of a New Perioperative Echocardiography Service Asian Cardiovasc Thorac Ann, December 1, 1998; 6(4): 300 - 305. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Ammar Monoplane, Biplane, or Multiplane Transducers: What Is Needed in the Operating Room? Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 1997; 1(1): 32 - 38. [PDF] |
||||
![]() |
H. Feigenbaum Evolution of Echocardiography Circulation, April 1, 1996; 93(7): 1321 - 1327. [Full Text] |
||||
![]() |
W. G. Daniel and A. Mugge Transesophageal Echocardiography N. Engl. J. Med., May 11, 1995; 332(19): 1268 - 1280. [Full Text] [PDF] |
||||
![]() |
S. Gordon, V. Aharonian, B. Corigliano, R. Parekh, R. Tester, and M. Butler Transesophageal Echocardiography in Endocarditis Journal of Diagnostic Medical Sonography, November 1, 1989; 5(6): 322 - 324. [PDF] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1976 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |