Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1977;55:497-503

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McLaughlin, P. R.
Right arrow Articles by Harrison, D. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McLaughlin, P. R.
Right arrow Articles by Harrison, D. C.
Right arrowPubmed/NCBI databases
*Compound via MeSH
*Substance via MeSH
Medline Plus Health Information
*Nuclear Scans
Hazardous Substances DB
*THALLIUM, ELEMENTAL

Circulation, Vol 55, 497-503, Copyright © 1977 by American Heart Association


ARTICLES

Reproducibility of thallium-201 myocardial imaging

PR McLaughlin, RP Martin, P Doherty, S Daspit, M Goris, W Haskell, S Lewis, JP Kriss and DC Harrison

Seventy-six thallium-201 myocardial perfusion studies were performed on twenty-five patients to assess their reproducibility and the effect ofvarying the level of exercise on the results of imaging. Each patient had a thallium-201 study at rest. Fourteen patients had studies on two occasions at maximum exercise, and twelve patients had studies both at light and at maximum exercise. Of 70 segments in the 14 patients assessed on each of two maximum exercise tests, 64 (91%) were reproducible. Only 53% (16/30) of the ischemic defects present at maximum exercise were seen in the light exercise study in the 12 patients assessed at two levels of exercise. Correlation of perfusion defects with arteriographically proven significant coronary stenosis was good for the left anterior descending and right coronary arteries, but not as good for circumflex artery disease. Thallium-201 myocardial imaging at maximum exercise is reproducible within acceptable limits, but careful attention to exercise technique is essential for valid comparative studies.


This article has been cited by other articles:


Home page
ANN INTERN MEDHome page
T. S. Kotler and G. A. Diamond
Exercise Thallium-201 Scintigraphy in the Diagnosis and Prognosis of Coronary Artery Disease
Ann Intern Med, November 1, 1990; 113(9): 684 - 702.
[Abstract] [PDF]