Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1979;60:231-240

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gascho, J. A.
Right arrow Articles by O'Brien, W. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gascho, J. A.
Right arrow Articles by O'Brien, W. M.

Circulation, Vol 60, 231-240, Copyright © 1979 by American Heart Association


ARTICLES

Determinants of ventricular defibrillation in adults

JA Gascho, RS Crampton, ML Cherwek, JN Sipes, FP Hunter and WM O'Brien

Conventional defibrillators which stored no more than 400 J and used damped sine wave pulses defibrillated 240 of 253 (95%) episodes of ventricular fibrillation (VF) in 94 prospectively assessed resuscitations in 88 adults. Shocks of 80--240 J (under 3 J/kg) delivered to the chest wall defibrillated more often than higher energy levels. Defibrillation rate did not correlate with weight. Defibrillation was determined by the diagnosis and setting in which VF occurred. Patients with acute myocardial infarction (AMI) and primary VF or with coronary disease and no AMI defibrillated more easily than patients with AMI and secondary VF or with no coronary disease. VF in a terminal patient (agonal VF) defibrillated less often than VF in other clinical situations. Age, weight, delivered energy, duration of pulse wave, and duration of VF had little, if any, influence on rate of defibrillation. These data fail to support the use of more expensive, high-output defibrillators sold by 11 or 14 American manufactures.


This article has been cited by other articles:


Home page
Card Surg AdultHome page
M. P. Anstadt and J. E. Lowe
Cardiopulmonary Resuscitation
Card. Surg. Adult, January 1, 2008; 3(2008): 487 - 506.
[Full Text]


Home page
ANN INTERN MEDHome page
N. K. Choudhry, S. Choudhry, and P. A. Singer
CPR for Patients Labeled DNR: The Role of the Limited Aggressive Therapy Order
Ann Intern Med, January 7, 2003; 138(1): 65 - 68.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
M. P. Anstadt and J. E. Lowe
Cardiopulmonary Resuscitation
Card. Surg. Adult, January 1, 2003; 2(2003): 471 - 494.
[Full Text]


Home page
Arch Intern MedHome page
M. S. Eisenberg, J. F. Pantridge, L. A. Cobb, and J. S. Geddes
The Revolution and Evolution of Prehospital Cardiac Care
Arch Intern Med, August 12, 1996; 156(15): 1611 - 1619.
[Abstract] [PDF]


Home page
JAMAHome page
R. S. Hummel III, J. P. Ornato, S. M. Weinberg, and A. M. Clarke
Spark-Generating Properties of Electrode Gels Used During Defibrillation: A Potential Fire Hazard
JAMA, November 25, 1988; 260(20): 3021 - 3024.
[Abstract] [PDF]


Home page
JAMAHome page
Standards and Guidelines for Cardiopulmonary Resuscitation (CPR) and Emergency Cardiac Care (ECC)
JAMA, June 6, 1986; 255(21): 2905 - 2984.
[Abstract] [PDF]


Home page
JAMAHome page
Standards and Guidelines for Cardiopulmonary Resuscitation (CPR) and Emergency Cardiac Care (ECC)
JAMA, August 1, 1980; 244(5): 453 - 509.
[Abstract] [PDF]