Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1979;60:62-70

This Article
Right arrow Order Full text via Infotrieve
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gabbay, S.
Right arrow Articles by Frater, R. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gabbay, S.
Right arrow Articles by Frater, R. W.

Circulation, Vol 60, 62-70, Copyright © 1979 by American Heart Association


ARTICLES

In vitro hydrodynamic comparison of mitral valve bioprostheses

S Gabbay, DM McQueen, EL Yellin and RW Frater

With the use of the pulse duplicator built in our laboratory, the hydrodynamic characteristics of three sizes of the four commercially available mitral bioprostheses, Hancock, Carpentier-Edwards, Angell- Shiley, and Ionescu-Shiley, were studied and compared. A wide range of performance was found: for example, during pulsatile testing, at peak flow of 15 1/min (corresonding to a normal resting cardiac output) transvalvular gradients varied from as high as 20 mm Hg (Angell-Shiley) to 5 mm Hg(Ionescu-Shiley) in the 25 mm mounting diameter size. Effective orifice areas (EOA) are significantly different in valves of the same mounting size, e.g., at peak flows of 20 1/min, the Ionescu- Shiley 25 provides an EOA of 1.7 cm2 while the Angell-Shiley provides only 1.17 cm2. The EOAs of all bioprostheses have been found to increase with increasing flow (e.g., from 10--30 1/min peak flow, the Hancock 25 changed from 1.25 cm2 to 1.50 cm2). The Gorlin formula, as constituted for calculating the area of stenotic mitral valves, is inappropriate for prosthetic valves. But the discharge coefficients of the bioprostheses have been found to be around 1 when the planimetered area of the open valve orifice is determined at a given flow. By using this discharge coefficient, the Gorlin formula will give an excellent estimate of the true orifice area of mitral bioprostheses.