Circulation, Vol 72, 327-333, Copyright © 1985 by American Heart Association
DE Jansen, JR Corbett, CL Wolfe, SE Lewis, G Gabliani, N Filipchuk, G Redish, RW Parkey, LM Buja and AS Jaffe
Single photon-emission computed tomography (SPECT) with 99mTc-
pyrophosphate (PPi) has been shown to estimate size of myocardial
infarction accurately in animals. We tested the hypothesis that SPECT with
99mTc-PPi and blood pool subtraction can provide prompt and accurate
estimates of size of myocardial infarction in patients. SPECT estimates are
potentially available early after the onset of infarction and should
correlate with estimates of infarct size calculated from serial
measurements of plasma MB-creatine kinase (CK) activity. Thirty- three
patients with acute myocardial infarction and 16 control patients without
acute myocardial infarction were studied. Eleven of the patients had
transmural anterior myocardial infarction, 16 had transmural inferior
myocardial infarction, and six had nontransmural myocardial infarction.
SPECT was performed with a commercially available rotating gamma camera.
Identical projection images of the distribution of 99mTc-PPi and the
ungated cardiac blood pool were acquired sequentially over 180 degrees.
Reconstructed sections were color coded and superimposed for purposes of
localization of infarct. Areas of increased PPi uptake within myocardial
infarcts were thresholded at 65% of peak activity. The blood pool was
thresholded at 50% and subtracted to determine the endocardial border for
the left ventricle. Myocardial infarcts ranged in size from 1 to 126 gram
equivalents (geq) MB-CK. The correlation of MB-CK estimates of size of
infarct with size determined by SPECT (both in geq) was good (r = .89 with
a regression line of y = 13.1 + 1.5x).(ABSTRACT TRUNCATED AT 250 WORDS)
ARTICLES
Quantification of myocardial infarction: a comparison of single photon- emission computed tomography with pyrophosphate to serial plasma MB- creatine kinase measurements
This article has been cited by other articles:
![]() |
H. Fonge, K. Vunckx, H. Wang, Y. Feng, L. Mortelmans, J. Nuyts, G. Bormans, A. Verbruggen, and Y. Ni Non-invasive detection and quantification of acute myocardial infarction in rabbits using mono-[123I]iodohypericin {micro}SPECT Eur. Heart J., January 2, 2008; 29(2): 260 - 269. [Abstract] [Full Text] [PDF] |
||||
|