Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1986;73:1029-1036

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Holt, P. M.
Right arrow Articles by Boyd, E. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Holt, P. M.
Right arrow Articles by Boyd, E. G.

Circulation, Vol 73, 1029-1036, Copyright © 1986 by American Heart Association


ARTICLES

Hematologic effects of the high-energy endocardial ablation technique

PM Holt and EG Boyd

Ablation of atrioventricular conduction is now widely accepted in the management of supraventricular arrhythmias. Reports of high temperatures, high pressures, and gas production suggest that there may be adverse effects on the blood, the electrode, and the cardiovascular system. In this investigation, using samples of fresh, heparinized pig blood, we measured hemolytic damage, the liberated gas volume and composition, and electrode erosion associated with high-energy electrical ablation. The blood was tested in a 10 liter tank at room temperature. Impulses of 10 to 400 J were applied to new USCI No. 6F bipolar pacing electrodes using both positive and negative polarities. Voltage and current waveforms were recorded. The volume of gas liberated with cathodal electrodes was 0.50 microliter/J up to 50 J and 0.29 microliter/J above 100 J. It was composed predominantly of hydrogen and nitrogen, with carbon dioxide and oxygen. With positive electrodes, the gas volume was linearly related to energy at 4.34 microliter/J up to 200 J and also contained carbon monoxide. The hemolysis was directly proportional to impulse energy for both cathodal and anodal electrodes, being 1.37 microliter/J and 4.48 microliters/J, respectively. Electrode erosion was substantial but clinically acceptable. We conclude that there are marked differences in the energy conversion processes and, where the same energy can achieve a comparable clinical effectiveness, there are advantages in using a cathodal electrode polarity. It is also advisable to use lower energies.