Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1993;88:1724-1729

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Uehata, A.
Right arrow Articles by Yeung, A. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Uehata, A.
Right arrow Articles by Yeung, A. C.

Circulation, Vol 88, 1724-1729, Copyright © 1993 by American Heart Association


ARTICLES

Accuracy of electronic digital calipers compared with quantitative angiography in measuring coronary arterial diameter

A Uehata, T Matsuguchi, JA Bittl, J Orav, IT Meredith, TJ Anderson, AP Selwyn, P Ganz and AC Yeung
Cardiovascular Division, Brigham and Women's Hospital, Boston, Mass.

BACKGROUND: Quantitative angiography is the accepted method for measuring coronary luminal diameter. Electronic digital calipers have been used to assess arterial diameters in vasomotor function studies and after interventional procedures. However, careful validation of calipers against quantitative angiography has not been described. METHODS AND RESULTS. We used digital calipers and quantitative angiography to measure 517 arterial diameters (88 nonstenotic segments) in 24 transplant patients undergoing vasomotor function studies with acetylcholine and nitroglycerin, 20 stenoses in 14 patients with coronary artery disease, and 15 stenoses in 15 patients before and after excimer laser-facilitated coronary angioplasty and at 6 months' follow-up. In nonstenotic arterial segments ranging in size from 0.6 to 3.5 mm, calipers overestimated diameters measured by quantitative angiography by 0.29 +/- 0.21 mm (mean +/- SD) (limits of agreement, - 0.13 to 0.71 mm). However, when the vasomotor responses were expressed as percent diameter change, the two methods did not differ significantly (-1 +/- 10%; limits of agreement, -21% to 19%). In the 35 stenoses measured before intervention and 30 stenoses measured after intervention, calipers and quantitative angiography differed by 3 +/- 9% (limits of agreement, -15% to 21%) across a range of stenosis severity (11% to 80%). Repeat caliper measurements by the same observer of the percent diameter change in the transplant patients and the percent stenosis in the coronary artery disease patients led to standard deviations of the differences of 9.3% and 7.6%, respectively. Two different observers recorded percent diameter change and percent stenosis that differed with standard deviations of 9.6% and 7.8%, respectively. CONCLUSIONS. Quantitative angiography and electronic digital calipers produce similar relative changes in arterial diameters and percent stenosis in a broad range of severities. Digital calipers thus are a rapid and convenient alternative to computerized quantitative angiography in certain research studies and clinical practice of assessing stenosis severity.


This article has been cited by other articles:


Home page
CirculationHome page
C. J. Cooper, S. T. Haller, W. Colyer, M. Steffes, M. W. Burket, W. J. Thomas, R. Safian, B. Reddy, P. Brewster, M. A. Ankenbrandt, et al.
Embolic Protection and Platelet Inhibition During Renal Artery Stenting
Circulation, May 27, 2008; 117(21): 2752 - 2760.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
J. M. Tsutsui, F. Xie, D. Cloutier, S. Kalvaitis, A. Elhendy, and T. R. Porter
Real-time dobutamine stress myocardial perfusion echocardiography predicts outcome in the elderly
Eur. Heart J., February 1, 2008; 29(3): 377 - 385.
[Abstract] [Full Text] [PDF]


Home page
Biol Res NursHome page
D. J. Kennedy, M. W. Burket, S. A. Khuder, J. I. Shapiro, R. V. Topp, and C. J. Cooper
Quality of life improves after renal artery stenting.
Biol Res Nurs, October 1, 2006; 8(2): 129 - 137.
[Abstract] [PDF]


Home page
JAMAHome page
M. J. Garcia, J. Lessick, M. H. K. Hoffmann, and for the CATSCAN Study Investigators
Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis.
JAMA, July 26, 2006; 296(4): 403 - 411.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
E. Ghersin, D. Litmanovich, R. Dragu, S. Rispler, J. Lessick, A. Ofer, O. R. Brook, L. Gruberg, R. Beyar, and A. Engel
16-MDCT Coronary Angiography Versus Invasive Coronary Angiography in Acute Chest Pain Syndrome: A Blinded Prospective Study
Am. J. Roentgenol., January 1, 2006; 186(1): 177 - 184.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
M. H. K. Hoffmann
Coronary Angiography With Multislice Computed Tomography--Reply
JAMA, November 9, 2005; 294(18): 2298 - 2299.
[Full Text] [PDF]


Home page
Diabetes CareHome page
A. Elhendy, J. M. Tsutsui, E. L. O'Leary, F. Xie, A. C. McGrain, and T. R. Porter
Noninvasive Diagnosis of Coronary Artery Disease in Patients With Diabetes by Dobutamine Stress Real-Time Myocardial Contrast Perfusion Imaging
Diabetes Care, July 1, 2005; 28(7): 1662 - 1667.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
M. H. K. Hoffmann, H. Shi, B. L. Schmitz, F. T. Schmid, M. Lieberknecht, R. Schulze, B. Ludwig, U. Kroschel, N. Jahnke, W. Haerer, et al.
Noninvasive Coronary Angiography With Multislice Computed Tomography
JAMA, May 25, 2005; 293(20): 2471 - 2478.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. M. Tsutsui, A. Elhendy, F. Xie, E. L. O'Leary, A. C. McGrain, and T. R. Porter
Safety of dobutamine stress real-time myocardial contrast echocardiography
J. Am. Coll. Cardiol., April 19, 2005; 45(8): 1235 - 1242.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. Elhendy, E. L. O'Leary, F. Xie, A. C. McGrain, J. R. Anderson, and T. R. Porter
Comparative accuracy of real-time myocardial contrast perfusion imaging and wall motion analysis during dobutamine stress echocardiography for the diagnosis of coronary artery disease
J. Am. Coll. Cardiol., December 7, 2004; 44(11): 2185 - 2191.
[Abstract] [Full Text] [PDF]


Home page
Biol Res NursHome page
B. K. Reddy, D. J. Kennedy, W. R. Colyer, M. W. Burket, W. J. Thomas, S. A. Khuder, J. I. Shapiro, R. V. Topp, and C. J. Cooper
Compliance with Antihypertensive Therapy after Renal Artery Stenting
Biol Res Nurs, July 1, 2003; 5(1): 37 - 46.
[Abstract] [PDF]


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
S. Kinlay, J. Grewal, D. Manuelin, J. C. Fang, A. P. Selwyn, J. A. Bittl, and P. Ganz
Coronary Flow Velocity and Disturbed Flow Predict Adverse Clinical Outcome After Coronary Angioplasty
Arterioscler. Thromb. Vasc. Biol., August 1, 2002; 22(8): 1334 - 1340.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. L. Houghton, E. F. Philbin, D. S. Strogatz, M. T. Torosoff, S. A. Fein, P. A. Kuhner, V. E. Smith, and A. A. Carr
The presence of African American race predicts improvement in coronary endothelial function after supplementary L-arginine
J. Am. Coll. Cardiol., April 17, 2002; 39(8): 1314 - 1322.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
T. R. Porter, F. Xie, M. Silver, D. Kricsfeld, and E. O'Leary
Real-time perfusion imaging with low mechanical index pulse inversion Doppler imaging
J. Am. Coll. Cardiol., March 1, 2001; 37(3): 748 - 753.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
C. R. deFilippi, M. Tocchi, R. J. Parmar, S. Rosanio, G. Abreo, M. A. Potter, M. S. Runge, and B. F. Uretsky
Cardiac troponin T in chest pain unit patients without ischemic electrocardiographic changes: angiographic correlates and long-term clinical outcomes
J. Am. Coll. Cardiol., June 1, 2000; 35(7): 1827 - 1834.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
Y. Nakayama, K. Tsumura, N. Yamashita, K. Yoshimaru, and T. Hayashi
Pulsatility of Ascending Aortic Pressure Waveform Is a Powerful Predictor of Restenosis After Percutaneous Transluminal Coronary Angioplasty
Circulation, February 8, 2000; 101(5): 470 - 472.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. J. Scanlon, D. P. Faxon, A.-M. Audet, B. Carabello, G. J. Dehmer, K. A. Eagle, R. D. Legako, D. F. Leon, J. A. Murray, S. E. Nissen, et al.
ACC/AHA guidelines for coronary angiography: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Coronary Angiography) developed in collaboration with the Society for Cardiac Angiography and Interventions
J. Am. Coll. Cardiol., May 1, 1999; 33(6): 1756 - 1824.
[Full Text] [PDF]


Home page
HeartHome page
S C Eccleshall, P J Jordan, N P Buller, and J N Townend
In vitro validation of the luminal measurement of a novel catheter based moulding technique
Heart, February 1, 1999; 81(2): 206 - 211.
[Abstract] [Full Text]


Home page
J Am Coll CardiolHome page
R. N. Piana, W. H. Ahmed, B. Chaitman, P. Ganz, S. Kinlay, J. Strony, B. Adelman, J. A. Bittl, and on behalf of the Hirulog Angioplasty Study Investi
Effect of transient abrupt vessel closure during otherwise successful angioplasty for unstable angina on clinical outcome at six months
J. Am. Coll. Cardiol., January 1, 1999; 33(1): 73 - 78.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
N. Reifart, M. Vandormael, M. Krajcar, S. Gohring, W. Preusler, F. Schwarz, H. Storger, M. Hofmann, J. Klopper, S. Muller, et al.
Randomized Comparison of Angioplasty of Complex Coronary Lesions at a Single Center : Excimer Laser, Rotational Atherectomy, and Balloon Angioplasty Comparison (ERBAC) Study
Circulation, July 1, 1997; 96(1): 91 - 98.
[Abstract] [Full Text]


Home page
CirculationHome page
V. L. Roger, P. A. Pellikka, M. R. Bell, C. W.H. Chow, K. R. Bailey, and J. B Seward
Sex and Test Verification Bias: Impact on the Diagnostic Value of Exercise Echocardiography
Circulation, January 21, 1997; 95(2): 405 - 410.
[Abstract] [Full Text]


Home page
CirculationHome page
S. G. Ellis, N. Omoigui, J. A. Bittl, M. Lincoff, M. W. Wolfe, G. Howell, and E. J. Topol
Analysis and Comparison of Operator-Specific Outcomes in Interventional Cardiology : From a Multicenter Database of 4860 Quality-Controlled Procedures
Circulation, February 1, 1996; 93(3): 431 - 439.
[Abstract] [Full Text]


Home page
CirculationHome page
C. J. Cooper, M. J. Landzberg, T. J. Anderson, F. Charbonneau, M. A. Creager, P. Ganz, and A. P. Selwyn
Role of Nitric Oxide in the Local Regulation of Pulmonary Vascular Resistance in Humans
Circulation, January 15, 1996; 93(2): 266 - 271.
[Abstract] [Full Text]


Home page
NEJMHome page
J. A. Bittl, J. Strony, J. A. Brinker, W. H. Ahmed, C. R. Meckel, B. R. Chaitman, J. Maraganore, E. Deutsch, B. Adelman, and The Hirulog Angioplasty Study Investigators
Treatment with Bivalirudin (Hirulog) as Compared with Heparin during Coronary Angioplasty for Unstable or Postinfarction Angina
N. Engl. J. Med., September 21, 1995; 333(12): 764 - 769.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. W. Wolfe, G. S. Roubin, M. Schweiger, J. M. Isner, J. J. Ferguson, A. D. Cannon, M. Cleman, H. Cabin, F. Leya, R. Bonan, et al.
Length of Hospital Stay and Complications After Percutaneous Transluminal Coronary Angioplasty : Clinical and Procedural Predictors
Circulation, August 1, 1995; 92(3): 311 - 319.
[Abstract] [Full Text]