Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1995;91:821-830

This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ismail, S.
Right arrow Articles by Kaul, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ismail, S.
Right arrow Articles by Kaul, S.

(Circulation. 1995;91:821-830.)
© 1995 American Heart Association, Inc.


Articles

Detection of Coronary Stenoses and Quantification of the Degree and Spatial Extent of Blood Flow Mismatch During Coronary Hyperemia With Myocardial Contrast Echocardiography

Presented in part at the 66th Scientific Sessions of the American Heart Association, Atlanta, Ga, November 8-11, 1993.

Suad Ismail, MD; Ananda R. Jayaweera, PhD; Norman C. Goodman, BSc; Gustavo P. Camarano, MD; Danny M. Skyba, MSc; Sanjiv Kaul, MD

From the Cardiovascular Division, University of Virginia School of Medicine, Charlottesville.

Correspondence to Sanjiv Kaul, MD, Cardiovascular Division, Box 158, University of Virginia, Charlottesville, VA 22908.

Background We hypothesized that the degree and spatial extent of blood flow mismatch in beds supplied by stenoses that are not flow-limiting at rest can be quantified with myocardial contrast echocardiography (MCE) using left atrial (LA) and right atrial (RA) injections of contrast during pharmacologically induced coronary hyperemia.

Methods and Results In 12 open-chest dogs, MCE was performed and myocardial blood flow (MBF) was measured by use of radiolabeled microspheres at baseline and during phenylephrine-induced coronary hyperemia. In the presence of this drug, stenoses were placed during different stages on the left anterior descending (LAD) and left circumflex (LCx) coronary arteries, and MCE and MBF assessments were performed. LA injections of 2 mL of 0.5 billion/mL microbubbles (mean diameter, 4.3 µm) were performed at each stage in all 12 dogs, and RA injections of 10 mL of 6 billion/mL microbubbles (mean diameter, 3.7 to 5.3 µm) were administered in 7 dogs. MCE images in which the contrast disparity between the LAD and LCx beds was maximal were digitally subtracted from precontrast images, and mean videointensities in these beds were measured after the dynamic range of gray-scale intensities was increased in the subtracted image and the image was color coded. The region showing hypoperfusion during LAD stenosis was planimetered and expressed as a percentage of the myocardial area in the short-axis slice. There was an excellent correlation between the LAD/LCx bed videointensity ratio and LAD/LCx bed MBF ratio (y=0.5x+0.44, r=.91, P<.001) during 57 LA injections. There was also an excellent correlation between the hypoperfused bed size on MCE during LA injection of contrast in the presence of LAD stenosis and the hypoperfused myocardium as determined by radiolabeled microspheres (y=0.8x+4.2, r=.90, P<.001, SEE=2.4, n=11). The anterior myocardium was opacified in 6 dogs receiving RA injections of contrast, and the hypoperfused area during LAD stenosis correlated closely with that determined by radiolabeled microspheres (y=0.86x+3.4, r=.93, P<.01).

Conclusions Coronary stenoses, which are not flow limiting at rest, can be detected and the degree and spatial extent of blood flow mismatch during pharmacologically induced coronary hyperemia can be quantified with MCE using LA and RA injections of contrast. Thus, it is possible that the severity of coronary stenoses and the quantum of myocardium in jeopardy could be quantified in the future with MCE using venous injection of contrast.


Key Words: stenosis • blood flow • echocardiography




This article has been cited by other articles:


Home page
CirculationHome page
S. Kaul
Myocardial Contrast Echocardiography: A 25-Year Retrospective
Circulation, July 15, 2008; 118(3): 291 - 308.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. A. Dijkmans, R. Senior, H. Becher, T. R. Porter, K. Wei, C. A. Visser, and O. Kamp
Myocardial Contrast Echocardiography Evolving as a Clinically Feasible Technique for Accurate, Rapid, and Safe Assessment of Myocardial Perfusion: The Evidence So Far
J. Am. Coll. Cardiol., November 8, 2006; (2006) j.jacc.2006.05.079v1.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
T. R. Porter, F. Xie, M. Silver, D. Kricsfeld, and E. O'Leary
Real-time perfusion imaging with low mechanical index pulse inversion Doppler imaging
J. Am. Coll. Cardiol., March 1, 2001; 37(3): 748 - 753.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
E. Leistad, K. Ohmori, T. A. Peterson, G. Christensen, and A. N. DeMaria
Quantitative assessment of myocardial perfusion during graded coronary artery stenoses by intravenous myocardial contrast echocardiography
J. Am. Coll. Cardiol., February 1, 2001; 37(2): 624 - 631.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
M. Scherrer-Crosbie, W. Steudel, R. Ullrich, P. R. Hunziker, N. Liel-Cohen, J. Newell, J. Zaroff, W. M. Zapol, and M. H. Picard
Echocardiographic determination of risk area size in a murine model of myocardial ischemia
Am J Physiol Heart Circ Physiol, September 1, 1999; 277(3): H986 - H992.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
T. Sakuma, Y. Hayashi, K. Sumii, M. Imazu, and M. Yamakido
Prediction of short- and intermediate-term prognoses of patients with acute myocardial infarction using myocardial contrast echocardiography one day after recanalization
J. Am. Coll. Cardiol., October 1, 1998; 32(4): 890 - 897.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. Kaul
Myocardial Contrast Echocardiography : 15 Years of Research and Development
Circulation, November 18, 1997; 96(10): 3745 - 3760.
[Full Text]


Home page
CirculationHome page
J. Sklenar, G. Camarano, N. C. Goodman, S. Ismail, A. R. Jayaweera, and S. Kaul
Contractile Versus Microvascular Reserve for the Determination of the Extent of Myocardial Salvage After Reperfusion: The Effect of Residual Coronary Stenosis
Circulation, September 15, 1996; 94(6): 1430 - 1440.
[Abstract] [Full Text]


Home page
CirculationHome page
T. R. Porter and F. Xie
Transient Myocardial Contrast After Initial Exposure to Diagnostic Ultrasound Pressures With Minute Doses of Intravenously Injected Microbubbles : Demonstration and Potential Mechanisms
Circulation, November 1, 1995; 92(9): 2391 - 2395.
[Abstract] [Full Text]