Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1995;92:132-136

This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Backer, C. L.
Right arrow Articles by Mavroudis, C.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Backer, C. L.
Right arrow Articles by Mavroudis, C.

(Circulation. 1995;92:132-136.)
© 1995 American Heart Association, Inc.


Articles

Coarctation of the Aorta

Repair With Polytetrafluoroethylene Patch Aortoplasty

Carl L. Backer, MD; Kerry Paape, MD; Vincent R. Zales, MD; Thomas J. Weigel, MD; Constantine Mavroudis, MD

From the Divisions of Cardiovascular-Thoracic Surgery (C.L.B., K.P., C.M.) and Cardiology (V.R.Z., T.J.W.), The Children's Memorial Hospital, and the Departments of Surgery and Pediatrics, Northwestern University Medical School, Chicago, Ill.

Background The first successful surgical repair of coarctation of the aorta (CoAo) was performed in 1944, but during the years that followed a high incidence of recoarctation was seen, ranging from 20% to 86%. In response to that problem, the patch aortoplasty was introduced in 1957; however, true aneurysms were found in the aortic wall opposite the patch after Dacron patch aortoplasty, particularly when the coarctation ridge was excised. The purpose of our review was to evaluate the results of patch aortoplasty for CoAo using a relatively new material, polytetrafluoroethylene (PTFE), and an operative technique that does not involve resection of the coarctation ridge.

Methods and Results Between 1979 and 1993, 125 infants and children underwent PTFE patch aortoplasty for CoAo; 111 of the procedures were primary repairs, and 14 were reoperations. Diagnoses were isolated CoAo (96 patients), CoAo and ventricular septal defect (15 patients), and CoAo with complex intracardiac anomaly (14 patients). Patient age at the time of repair ranged from 4 days to 17 years (mean age, 5.1±4.5 years). There were no instances of intraoperative mortality or paraplegia. There were 4 deaths from 10 to 40 days postoperatively, all in neonates (mean age, 33 days) who received additional intracardiac procedures for complex associated anomalies. Follow-up has ranged from 6 months to 12.5 years (mean, 4.5±3.2 years). All children had postoperative chest roentgenograms, 80 (66%) patients have had a postoperative echocardiogram and 16 (13%) a cardiac catheterization. One patient had successful repair of a false aneurysm 4 months postoperatively. No patient has developed a late true aneurysm. Of the patients <1 month of age at the time of CoAo repair (12 patients), 6 patients had recurrent CoAo (gradient >20 mm Hg) compared with only 4 recurrences in 97 patients >1 month of age at the time of repair (P<.001).

Conclusions For children >1 year of age, PTFE patch aortoplasty remains our procedure of choice for CoAo repair because of the low mortality rate, low recoarctation rate, and absence of late true aneurysms. We have stopped using this technique for infants <1 month of age because of the high recurrence rate.


Key Words: surgery • pediatrics • coarctation • aorta




This article has been cited by other articles:


Home page
JRSMHome page
I. M Loftus, K. J Molloy, P. R F Bell, and A R. Naylor
Mycotic aortic aneurysm with protective coarctation
J R Soc Med, June 1, 2003; 96(6): 291 - 292.
[Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
P. Narasinga Rao, R. N. S. Kumar, D. Anil Kumar, H. M. Mohmoud, S. Chandran, A. K. Dhir, D. K. Saxena, S. P. Azhagappan, V. R. Pillai, C. G. Venkitachalam, et al.
Coarctation of the Aorta in Neonates And Young Infants: Surgical Experience
Asian Cardiovasc Thorac Ann, December 1, 2002; 10(4): 310 - 313.
[Abstract] [Full Text] [PDF]


Home page
Postgrad. Med. J.Home page
S Saunders and C Young
An unusual epistaxis
Postgrad. Med. J., October 1, 2002; 78(924): 619 - 620.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. L. Backer and C. Mavroudis
Congenital Heart Surgery Nomenclature and Database Project: patent ductus arteriosus, coarctation of the aorta, interrupted aortic arch
Ann. Thorac. Surg., April 1, 2000; 69(4): S298 - 307.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. L. Backer, C. Mavroudis, E. A. Zias, Z. Amin, and T. J. Weigel
Repair of coarctation with resection and extended end-to-end anastomosis
Ann. Thorac. Surg., October 1, 1998; 66(4): 1365 - 1370.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. A. Brauner, H. Laks, D. C. Drinkwater Jr, F. Scholl, and S. McCaffery
Multiple Left Heart Obstructions (Shone's Anomaly) With Mitral Valve Involvement: Long-Term Surgical Outcome
Ann. Thorac. Surg., September 1, 1997; 64(3): 721 - 729.
[Abstract] [Full Text]