Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1996;94:1974-1980

This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Behrens, S.
Right arrow Articles by Franz, M. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Behrens, S.
Right arrow Articles by Franz, M. R.

(Circulation. 1996;94:1974-1980.)
© 1996 American Heart Association, Inc.


Articles

Reduced Arrhythmogenicity of Biphasic Versus Monophasic T-Wave Shocks

Implications for Defibrillation Efficacy

Steffen Behrens, MD; Cuilan Li, PhD; Paulus Kirchhof, BS; F. Larissa Fabritz, BS; Michael R. Franz, MD, PhD

the Cardiology Divisions of the Veterans Administration Medical Center and Georgetown University, Washington, DC. (S.B., C.L., P.K., F.L.F., M.R.F.) and the Klinikum Benjamin Franklin, Free University, Berlin, Germany (S.B.).

Correspondence to Michael R. Franz, MD, PhD, Cardiology Division, Veterans Administration Medical Center, 50 Irving St NW, Washington, DC 20422.

Background Biphasic waveforms defibrillate more effectively than monophasic waveforms; however, the mechanism remains unknown. The "upper-limit-of-vulnerability" hypothesis of defibrillation suggests that unsuccessful defibrillation is due to reinduction of ventricular fibrillation (VF). Thus, VF induction mechanisms may be important for the understanding of defibrillation mechanisms. We therefore compared myocardial VF vulnerability for monophasic versus biphasic shocks.

Methods and Results In 10 Langendorff-perfused rabbit hearts, monophasic and biphasic T-wave shocks were randomly administered over a wide range of shock coupling intervals and shock strengths, and the two-dimensional coordinates within which VF was induced were used to calculate the area of vulnerability (AOV) for both shock waveforms. The arrhythmic response to biphasic shocks differed from that to monophasic shocks in three distinct ways: (1) the AOV was smaller (8.9±4.2 versus 13.9±6.0 area units, P<.02), (2) the transition zone between VF-inducing and nonarrhythmogenic shocks was narrower (14.7±4.8 versus 29.9±6.4 area units, P<.001), and (3) the entire AOV shifted toward longer coupling intervals (by 11.0±8.8 ms at the left border [P<.005] and 6.0±5.2 ms at the right border [P=.005] of the AOV).

Conclusions Biphasic shocks encounter a smaller AOV than monophasic shocks, a narrower transition zone from VF to no arrhythmia induction, and a lesser effectiveness in inducing VF at short coupling intervals. In keeping with the upper-limit-of-vulnerability hypothesis, these waveform-dependent differences in VF inducibility might help explain the lower defibrillation threshold for biphasic shocks.


Key Words: electrophysiology • fibrillation • defibrillation • shock




This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
J. J. Sims, A. W. Miller, and M. R. Ujhelyi
Disparate effects of biphasic and monophasic shocks on postshock refractory period dispersion
Am J Physiol Heart Circ Physiol, June 1, 1998; 274(6): H1943 - H1949.