(Circulation. 1997;95:2155-2161.)
© 1997 American Heart Association, Inc.
Articles |
From the Hospital of the Westfälische Wilhelms-University, Department of Cardiology and Angiology and Institute for Arteriosclerosis Research, Münster, Germany.
Correspondence to Hans Kottkamp, MD, Westfälische Wilhelms-Universität Münster, Medizinische Klinik und Poliklinik, Innere Medizin C (Kardiologie und Angiologie), D-48129 Münster, Germany.
Background The ability of radiofrequency energy to extend across scar tissue is unknown. We investigated the effects of radiofrequency catheter ablation on intramural temperature in experimental chronic myocardial infarction.
Methods and Results Myocardial infarction was induced in eight dogs by a transcatheter coronary artery occlusion-reperfusion technique. The dogs were reanesthetized after 15 to 24 days. Four additional dogs served as controls. The freshly excised preparations were cut and placed in a saline bath at 37°C. Temperature-guided energy applications with a preselected catheter tip temperature of 80°C were performed for 60 seconds with a 7F ablation catheter. Thermoelements were inserted into the ventricular muscle at depths of 2.5 to 3.0 mm ("subendocardial") and 5.5 to 6.0 mm ("intramural"). Surviving muscle fibers were interspersed among the transmural scar tissue. The maximal temperatures did not differ significantly between normal hearts and chronic infarctions at the subendocardial (64.5±6.4°C versus 66.7±6.6°C) or intramural thermoelement (51.9±5.7°C versus 52.3±5.7°C). The myocardial temperature rise was slow, and steady-state temperatures had not been reached after 60 seconds. The intramural temperatures in chronic infarctions measured 49.0±4.3°C after 40 seconds of energy delivery and were still below the critical tissue temperature of 50°C that is necessary to induce permanent myocardial damage.
Conclusions Temperature-guided radiofrequency ablation in a dog model of chronic myocardial infarction may induce tissue temperatures >50°C at a depth of 5.5 to 6.0 mm. The intramural temperature rise was slow, indicating that long energy applications might be necessary if the arrhythmogenic substrate is subepicardial.
Key Words: ablation catheter ablation myocardial infarction tachycardia
This article has been cited by other articles:
![]() |
S. P. Thomas, D. J.R. Guy, A. C. Boyd, V. E. Eipper, D. L. Ross, and R. B. Chard Comparison of epicardial and endocardial linear ablation using handheld probes Ann. Thorac. Surg., February 1, 2003; 75(2): 543 - 548. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. O. von Oppell, T. Rauch, G. Hindricks, H. Kottkamp, and F. Mohr Effectiveness of two radiofrequency ablation systems in atrial tissue Eur. J. Cardiothorac. Surg., November 1, 2001; 20(5): 956 - 960. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Erdogan, J. Carlsson, S. Grumbrecht, S. Kostin, B. Schulte, M. Schlapp, J. Neuzner, and H. F. Pitschner Electrochemical potentials during radiofrequency energy delivery: a new method to control catheter ablation of arrhythmias Europace, January 1, 2001; 3(3): 201 - 207. [Abstract] [PDF] |
||||
![]() |
H. H. Petersen, X. Chen, A. Pietersen, J. H. Svendsen, and S. Haunso Lesion Dimensions During Temperature-Controlled Radiofrequency Catheter Ablation of Left Ventricular Porcine Myocardium : Impact of Ablation Site, Electrode Size, and Convective Cooling Circulation, January 19, 1999; 99(2): 319 - 325. [Abstract] [Full Text] [PDF] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1997 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |