Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1998;98:2024-2029

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Amols, H. I.
Right arrow Articles by Weinberger, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Amols, H. I.
Right arrow Articles by Weinberger, J.

(Circulation. 1998;98:2024-2029.)
© 1998 American Heart Association, Inc.


Clinical Investigation and Reports

Intracoronary Radiation for Prevention of Restenosis

Dose Perturbations Caused by Stents

H. I. Amols, PhD; F. Trichter, DSc; ; J. Weinberger, MD, PhD

From Columbia University, Department of Radiation Oncology (H.I.A., F.T.) and Departments of Medicine and Pharmacology (J.W.), New York, NY.

Background—Intravascular irradiation with ß-emitters has been proposed for inhibition of restenosis in coronary arteries after balloon angioplasty or stent implantation. Previous studies have shown the effectiveness of {gamma}-radiation to prevent recurrent restenosis, even in the presence of an implanted stent. The limited range of ß-particles compared with {gamma}-radiation, however, opens the question of whether absorption and scattering of ß-particles by stent struts will cause significant perturbations in the uniformity and magnitude of the radiation dose, which may in turn compromise treatment.

Methods and Results—Nine different stents were deployed with a balloon filled with a ß-emitting radioactive liquid. Dose distributions were measured with Gafchromic film. Stents varied significantly in their absorption of ß-particles. Some stents, constructed of fine meshed wires, produced minimal dose perturbations. Others, with thicker, high-atomic-number struts, induced cold spots in the dose distribution adjacent to the wires of <=35%. Average dose reduction varied from 4% to 14% in the presence of various stents.

Conclusions—Radiation strategy may have to be tailored to stent design. Stents that minimally perturb the dose distribution may be deployed before irradiation. Those that significantly alter the radiation dose might be better deployed after irradiation. Dose prescriptions may require modification if such perturbations prove clinically significant. Observed dose perturbations, however, decreased rapidly with increasing distance from the stent, which may mitigate the clinical impact of these findings. This, as well as the effects of stents on {gamma}-dose distributions, requires further investigation.


Key Words: angioplasty • restenosis • brachytherapy • stents • beta rays




This article has been cited by other articles:


Home page
JOURNAL OF THE ICRUHome page
REFERENCES
J. ICRU, December 1, 2004; 4(2): 165 - 175.
[Full Text] [PDF]


Home page
CirculationHome page
Y. Morino, H. Kaneda, T. Fox, A. Takagi, A. H.M. Hassan, R. Bonan, I. Crocker, A. J. Lansky, W. K. Laskey, M. Suntharalingam, et al.
Delivered Dose and Vascular Response After {beta}-Radiation for In-Stent Restenosis: Retrospective Dosimetry and Volumetric Intravascular Ultrasound Analysis
Circulation, October 29, 2002; 106(18): 2334 - 2339.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
P.W. Serruys, G. Sianos, W. van der Giessen, H.J.R.M. Bonnier, P. Urban, W. Wijns, E. Benit, M. Vandormael, R. Dorr, C. Disco, et al.
Intracoronary {beta}-radiation to reduce restenosis after balloon angioplasty and stenting. The Beta Radiation In Europe (BRIE) study
Eur. Heart J., September 1, 2002; 23(17): 1351 - 1359.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
C. Hanefeld, S. Amirie, D. Borchardt, P. Grewe, K.-M. Muller, M. Kissler, and A. Mugge
Dosimetric Measurements in Isolated Human Coronary Arteries: Comparison of Commercially Available Iridium192 With Strontium/Yttrium90 Emitters
Circulation, May 28, 2002; 105(21): 2493 - 2496.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S.-W. Park, M.-K. Hong, D. H. Moon, S. J. Oh, C. W. Lee, J.-J. Kim, and S.-J. Park
Treatment of diffuse in-stent restenosis with rotational atherectomy followed by radiation therapy with a rhenium-188-mercaptoacetyltriglycine-filled balloon
J. Am. Coll. Cardiol., September 1, 2001; 38(3): 631 - 637.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. Makkar, J. Whiting, A. Li, H. Honda, M. C. Fishbein, F.F. Knapp, J. Hausleiter, F. Litvack, and N. L. Eigler
Effects of {beta}--Emitting 188Re Balloon in Stented Porcine Coronary Arteries : An Angiographic, Intravascular Ultrasound, and Histomorphometric Study
Circulation, December 19, 2000; 102(25): 3117 - 3123.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. E. Raizner, S. N. Oesterle, R. Waksman, P. W. Serruys, A. Colombo, Y.-L. Lim, A. C. Yeung, W. J. van der Giessen, L. Vandertie, J. K. Chiu, et al.
Inhibition of Restenosis With {beta}-Emitting Radiotherapy : Report of the Proliferation Reduction With Vascular Energy Trial (PREVENT)
Circulation, August 29, 2000; 102(9): 951 - 958.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. Hoher, J. Wohrle, M. Wohlfrom, H. Hanke, R. Voisard, H. H. Osterhues, M. Kochs, S. N. Reske, V. Hombach, and J. Kotzerke
Intracoronary {beta}-Irradiation With a Liquid 188Re-Filled Balloon : Six-Month Results From a Clinical Safety and Feasibility Study
Circulation, May 23, 2000; 101(20): 2355 - 2360.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. Waksman, B. Bhargava, L. White, R. C. Chan, R. Mehran, A. J. Lansky, G. S. Mintz, L. F. Satler, A. D. Pichard, M. B. Leon, et al.
Intracoronary {beta}-Radiation Therapy Inhibits Recurrence of In-Stent Restenosis
Circulation, April 25, 2000; 101(16): 1895 - 1898.
[Abstract] [Full Text] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
C. E. Chambers, S. T Riebel, and M. Kozak
Interventional Cardiology: Advances in Percutaneous Techniques for the Treatment of Cardiac Disease
Seminars in Cardiothoracic and Vascular Anesthesia, July 1, 1999; 3(2): 109 - 125.
[Abstract] [PDF]