(Circulation. 1998;98:2509-2512.)
© 1998 American Heart Association, Inc.
Brief Rapid Communications |
From the Thoraxcenter (B.J.R., R.J.G., P.O., P.J.F.) and Daniel den Hoed Kliniek (A.B., M.O.), Rotterdam, Netherlands
Correspondence to Benno J. Rensing, MD, Catheterization Laboratory, Thoraxcenter BD416, Dr Molewaterplein 40, 3015 GD Rotterdam, Netherlands. E-mail rensing{at}card.azr.nl
BackgroundNoninvasive detection of coronary stenoses with electron beam CT (EBCT) after intravenous injection of contrast medium has recently emerged. We sought to determine the diagnostic accuracy of EBCT angiography in the clinical setting using conventional coronary angiography as the "gold standard."
Methods and ResultsThirty-seven patients (30 men) were investigated. After intravenous injection of 150 mL of contrast medium, 40 to 60 consecutive transaxial tomograms, covering the proximal and middle parts of the coronary arteries, were obtained with ECG triggering at end diastole during breath-holding. Three-dimensional reconstructions of the proximal and middle parts of the arteries were compared with the conventional angiograms. Of the 259 proximal and middle coronary segments, 211 (81%) were analyzable by EBCT. Of the left anterior descending coronary artery (LAD) segments, 95% were assessable. Right coronary artery (RCA) and left circumflex artery (LCx) segments were assessable in 66% and 76%, respectively. Overall sensitivity and specificity to detect a >50% diameter stenosis were 77% and 94%, respectively. This was 82% and 92% for the LAD, 60% and 97% for the RCA, and 83% and 89% for the LCx (all figures based on assessable lesions).
ConclusionsIntravenous EBCT coronary angiography is a promising coronary imaging technique. The technique is not yet robust enough to be an alternative to conventional coronary angiography. It can detect and rule out significant coronary artery disease of the left main proximal and mid portions of the LAD with good accuracy.
Key Words: angiography tomography
This article has been cited by other articles:
![]() |
M. J. Budoff, S. Achenbach, R. S. Blumenthal, J. J. Carr, J. G. Goldin, P. Greenland, A. D. Guerci, J. A.C. Lima, D. J. Rader, G. D. Rubin, et al. Assessment of Coronary Artery Disease by Cardiac Computed Tomography: A Scientific Statement From the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology Circulation, October 17, 2006; 114(16): 1761 - 1791. [Full Text] [PDF] |
||||
![]() |
A S Lowe and C L Kay Recent developments in CT: a review of the clinical applications and advantages of multidetector computed tomography Imaging, June 1, 2006; 18(2): 62 - 67. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. S. Berman, R. Hachamovitch, L. J. Shaw, J. D. Friedman, S. W. Hayes, L. E.J. Thomson, D. S. Fieno, G. Germano, P. Slomka, N. D. Wong, et al. Roles of Nuclear Cardiology, Cardiac Computed Tomography, and Cardiac Magnetic Resonance: Assessment of Patients with Suspected Coronary Artery Disease J. Nucl. Med., January 1, 2006; 47(1): 74 - 82. [Abstract] [Full Text] [PDF] |
||||
![]() |
A F Kopp, A Kuttner, T Trabold, M Heuschmid, S Schroder, and C D Claussen Multislice CT in cardiac and coronary angiography Br. J. Radiol., December 1, 2004; 77(suppl_1): S87 - S97. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Lu, N. Zhuang, S.-S. Mao, J. Child, S. Carson, and M. J. Budoff Baseline Heart Rate-adjusted Electrocardiographic Triggering for Coronary Artery Electron-Beam CT Angiography Radiology, November 1, 2004; 233(2): 590 - 595. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Schlosser, T. Konorza, P. Hunold, H. Kuhl, A. Schmermund, and J.o. Barkhausen Noninvasive visualization of coronary artery bypass grafts using 16-detector row computed tomography J. Am. Coll. Cardiol., September 15, 2004; 44(6): 1224 - 1229. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Schoenhagen, S. S. Halliburton, A. E. Stillman, S. A. Kuzmiak, S. E. Nissen, E. M. Tuzcu, and R. D. White Noninvasive Imaging of Coronary Arteries: Current and Future Role of Multi-Detector Row CT Radiology, July 1, 2004; 232(1): 7 - 17. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Hoffmann, R. Millea, C. Enzweiler, M. Ferencik, S. Gulick, J. Titus, S. Achenbach, D. Kwait, D. Sosnovik, and T. J. Brady Acute Myocardial Infarction: Contrast-enhanced Multi-Detector Row CT in a Porcine Model Radiology, June 1, 2004; 231(3): 697 - 701. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Desjardins and E. A. Kazerooni ECG-Gated Cardiac CT Am. J. Roentgenol., April 1, 2004; 182(4): 993 - 1010. [Full Text] [PDF] |
||||
![]() |
M. J. Budoff, S. Achenbach, and A. Duerinckx Clinical utility of computed tomography and magnetic resonance techniques for noninvasive coronary angiography J. Am. Coll. Cardiol., December 3, 2003; 42(11): 1867 - 1878. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Gurevitch, T. Gaspar, B. Orlov, R. Amar, D. Dvir, N. Peled, and D. J. Aravot Noninvasive evaluation of arterial grafts with newly released multidetector computed tomography Ann. Thorac. Surg., November 1, 2003; 76(5): 1523 - 1527. [Abstract] [Full Text] [PDF] |
||||
![]() |
C R Peebles Non-invasive coronary imaging: computed tomography or magnetic resonance imaging? Heart, June 1, 2003; 89(6): 591 - 594. [Full Text] [PDF] |
||||
![]() |
A W Leber, A Knez, C Becker, A Becker, C White, C Thilo, M Reiser, R Haberl, and G Steinbeck Non-invasive intravenous coronary angiography using electron beam tomography and multislice computed tomography Heart, June 1, 2003; 89(6): 633 - 639. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Barriales-Villa, M. Penas-Lado, C. Moris, P. W.M. Fedak, S. Verma, T. E. David, R. D. Weisel, R. L. Leask, and J. Butany Bicuspid Aortic Valve and Coronary Anomalies * Response Circulation, April 29, 2003; 107 (16): e105 - e105. [Full Text] [PDF] |
||||
![]() |
R. L. Morin, T. C. Gerber, and C. H. McCollough Radiation Dose in Computed Tomography of the Heart Circulation, February 18, 2003; 107(6): 917 - 922. [Full Text] [PDF] |
||||
![]() |
K Nieman, B J Rensing, R-J M van Geuns, J Vos, P M T Pattynama, G P Krestin, P W Serruys, and P J de Feyter Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate Heart, December 1, 2002; 88(5): 470 - 474. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. Y. Kim, P. G. Danias, M. Stuber, S. D. Flamm, S. Plein, E. Nagel, S. E. Langerak, O. M. Weber, E. M. Pedersen, M. Schmidt, et al. Coronary Magnetic Resonance Angiography for the Detection of Coronary Stenoses N. Engl. J. Med., December 27, 2001; 345(26): 1863 - 1869. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Hong, C. R. Becker, A. Huber, U. J. Schoepf, B. Ohnesorge, A. Knez, R. Bruning, and M. F. Reiser ECG-gated Reconstructed Multi-Detector Row CT Coronary Angiography: Effect of Varying Trigger Delay on Image Quality Radiology, September 1, 2001; 220(3): 712 - 717. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Achenbach, T. Giesler, D. Ropers, S. Ulzheimer, H. Derlien, C. Schulte, E. Wenkel, W. Moshage, W. Bautz, W. G. Daniel, et al. Detection of Coronary Artery Stenoses by Contrast-Enhanced, Retrospectively Electrocardiographically-Gated, Multislice Spiral Computed Tomography Circulation, May 29, 2001; 103(21): 2535 - 2538. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. Moshage, S. Achenbach, and W. G. Daniel Novel approaches to the non-invasive diagnosis of coronary-artery disease Nephrol. Dial. Transplant., January 1, 2001; 16(1): 21 - 28. [Full Text] [PDF] |
||||
![]() |
S. Achenbach, S. Ulzheimer, U. Baum, M. Kachelrie{beta}, D. Ropers, T. Giesler, W. Bautz, W. G. Daniel, W. A. Kalender, and W. Moshage Noninvasive Coronary Angiography by Retrospectively ECG-Gated Multislice Spiral CT Circulation, December 5, 2000; 102(23): 2823 - 2828. [Abstract] [Full Text] [PDF] |
||||
![]() |
S Achenbach, D Ropers, M Regenfus, G Muschiol, W G Daniel, and W Moshage Contrast enhanced electron beam computed tomography to analyse the coronary arteries in patients after acute myocardial infarction Heart, November 1, 2000; 84(5): 489 - 493. [Abstract] [Full Text] |
||||
![]() |
P J de Feyter, K Nieman, P van Ooijen, and M Oudkerk IMAGING TECHNIQUES: Non-invasive coronary artery imaging with electron beam computed tomography and magnetic resonance imaging Heart, October 1, 2000; 84(4): 442 - 448. [Full Text] |
||||
![]() |
S. Achenbach, D. Ropers, J. Holle, G. Muschiol, W. G. Daniel, and W. Moshage In-Plane Coronary Arterial Motion Velocity: Measurement with Electron-Beam CT Radiology, August 1, 2000; 216(2): 457 - 463. [Abstract] [Full Text] |
||||
![]() |
P. M. A. van Ooijen, M. Oudkerk, R. J. M. van Geuns, B. J. Rensing, and P. J. de Feyter Coronary Artery Fly-Through Using Electron Beam Computed Tomography Circulation, July 4, 2000; 102 (1): e6 - e10. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. W. K. Kwok, Y. T. Lim, S. T. Quek, L. K. A. Tan, B. Kwok Wing Kuin, Y. T. Lim, S. T. Quek, and L. Tan Kheng Ann Electron-Beam Computed Tomography for Symptomatic Coronary Disease Asian Cardiovasc Thorac Ann, March 1, 2000; 8(1): 46 - 49. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. R. Margulis and J. H. Sunshine Radiology at the Turn of the Millennium1 Radiology, January 1, 2000; 214(1): 15 - 23. [Abstract] [Full Text] |
||||
![]() |
R J M van Geuns, H G de Bruin, B J W M Rensing, P A Wielopolski, M D Hulshoff, P M A van Ooijen, M Oudkerk, and P J de Feyter Magnetic resonance imaging of the coronary arteries: clinical results from three dimensional evaluation of a respiratory gated technique Heart, October 1, 1999; 82(4): 515 - 519. [Abstract] [Full Text] [PDF] |
||||
![]() |
B J Rensing, A H H Bongaerts, R J van Geuns, P M A van Ooijen, M Oudkerk, and P J de Feyter In vivo assessment of three dimensional coronary anatomy using electron beam computed tomography after intravenous contrast administration Heart, October 1, 1999; 82(4): 523 - 525. [Abstract] [Full Text] [PDF] |
||||
![]() |
Noninvasive Coronary Angiography Almost a Reality Journal Watch (General), December 18, 1998; 1998(1218): 2 - 2. [Full Text] |
||||
![]() |
S. E. Langerak, P. Kunz, H. W. Vliegen, J. W. Jukema, A. H. Zwinderman, P. Steendijk, H. J. Lamb, E. E. van der Wall, and A. de Roos MR Flow Mapping in Coronary Artery Bypass Grafts: A Validation Study with Doppler Flow Measurements Radiology, January 1, 2002; 222(1): 127 - 135. [Abstract] [Full Text] [PDF] |
||||
|