In this issue of Circulation, Koch and associates1 from the Cleveland Clinic published a study on the relationship between prosthetic valve size and the Duke Activity Status Index (DASI) after aortic valve replacement (AVR). The study was conducted with 1014 patients operated on from 1995 through 1998, completed 1 year later, and published now. DASI scores increased from a mean of 29 preoperatively to 46 postoperatively after a mean follow-up of 8.3 months. The investigators could find no obvious relationship between prosthetic valve size and postoperative DASI score. One of the limitations of the study was that prosthetic valve gradients and effective orifice areas were not measured by echocardiography to quantify prosthesispatient mismatch. It is also interesting to note that more than two thirds of the patients were in New York Heart Association functional classes I and II preoperatively, and yet the DASI mean score before surgery was only 29 out of a maximum of 58.2. For this reason alone, it must be assumed that factors other than the aortic valve disease played a role in the DASI score. Nevertheless, this is not the first study to suggest that valve size plays no role in the clinical outcomes of AVR.
See p 3221
Valve prosthesispatient mismatch (PPM) is a term introduced by Rahimtoola in 1978 to describe a condition in which the in vivo prosthetic valve effective orifice area is smaller than that of the native valve.2 According to this broad definition, every patient with a prosthetic heart valve
Related Article:
Circulation 2005 111: 3221-3229.
This article has been cited by other articles:
![]() |
V. A. Mannacio, V. De Amicis, L. Di Tommaso, F. Iorio, and C. Vosa Influence of prosthesis-patient mismatch on exercise-induced arrhythmias: A further aspect after aortic valve replacement J. Thorac. Cardiovasc. Surg., September 1, 2009; 138(3): 632 - 638. [Abstract] [Full Text] [PDF] |
||||
![]() |
J Mascherbauer, R Rosenhek, C Fuchs, E Pernicka, U Klaar, C Scholten, M Heger, G Wollenek, G Maurer, and H Baumgartner Moderate patient-prosthesis mismatch after valve replacement for severe aortic stenosis has no impact on short-term and long-term mortality Heart, December 1, 2008; 94(12): 1639 - 1645. [Abstract] [Full Text] [PDF] |
||||
![]() |
2006 WRITING COMMITTEE MEMBERS, R. O. Bonow, B. A. Carabello, K. Chatterjee, A. C. de Leon Jr, D. P. Faxon, M. D. Freed, W. H. Gaasch, B. W. Lytle, R. A. Nishimura, et al. 2008 Focused Update Incorporated Into the ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease): Endorsed by the Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons Circulation, October 7, 2008; 118(15): e523 - e661. [Full Text] [PDF] |
||||
![]() |
R. O. Bonow, B. A. Carabello, K. Chatterjee, A. C. de Leon Jr, D. P. Faxon, M. D. Freed, W. H. Gaasch, B. W. Lytle, R. A. Nishimura, P. T. O'Gara, et al. 2008 Focused Update Incorporated Into the ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease) Endorsed by the Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons J. Am. Coll. Cardiol., September 23, 2008; 52(13): e1 - e142. [Full Text] [PDF] |
||||
![]() |
S Bleiziffer, W B Eichinger, I Hettich, D Ruzicka, M Wottke, R Bauernschmitt, and R Lange Impact of patient-prosthesis mismatch on exercise capacity in patients after bioprosthetic aortic valve replacement Heart, May 1, 2008; 94(5): 637 - 641. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Dalmau, J. Maria Gonzalez-Santos, J. Lopez-Rodriguez, M. Bueno, A. Arribas, and F. Nieto One year hemodynamic performance of the Perimount Magna pericardial xenograft and the Medtronic Mosaic bioprosthesis in the aortic position: a prospective randomized study Interactive CardioVascular and Thoracic Surgery, June 1, 2007; 6(3): 345 - 349. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Bove, Y. Van Belleghem, K. Francois, F. Caes, H. Van Overbeke, and G. Van Nooten Stentless and stented aortic valve replacement in elderly patients: factors affecting midterm clinical and hemodynamical outcome Eur. J. Cardiothorac. Surg., November 1, 2006; 30(5): 706 - 713. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. O. Bonow, B. A. Carabello, K. Chatterjee, A. C. de Leon Jr, D. P. Faxon, M. D. Freed, W. H. Gaasch, B. W. Lytle, R. A. Nishimura, P. T. O'Gara, et al. ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease) Developed in Collaboration With the Society of Cardiovascular Anesthesiologists Endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of Thoracic Surgeons J. Am. Coll. Cardiol., August 1, 2006; 48(3): e1 - e148. [Full Text] [PDF] |
||||
![]() |
N. J. Howell, B. E. Keogh, V. Barnet, R. S. Bonser, T. R. Graham, S. J. Rooney, I. C. Wilson, and D. Pagano Patient-prosthesis mismatch does not affect survival following aortic valve replacement. Eur. J. Cardiothorac. Surg., July 1, 2006; 30(1): 10 - 14. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Dalmau, J. MariaGonzalez-Santos, J. Lopez-Rodriguez, M. Bueno, and A. Arribas The Carpentier-Edwards Perimount Magna aortic xenograft: a new design with an improved hemodynamic performance Interactive CardioVascular and Thoracic Surgery, June 1, 2006; 5(3): 263 - 267. [Abstract] [Full Text] [PDF] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2005 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |