Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2008;117:1912-1913
doi: 10.1161/CIRCULATIONAHA.108.770156
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Moss, A. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Moss, A. J.
Related Collections
Right arrow Congestive
Right arrow Ablation/ICD/surgery

(Circulation. 2008;117:1912-1913.)
© 2008 American Heart Association, Inc.


Editorial

Life Versus Death

Arthur J. Moss, MD

From the Heart Research Follow-Up Program of the Cardiology Division, Department of Medicine, University of Rochester School of Medicine and Dentistry, Rochester, NY.

Correspondence to Arthur J. Moss, MD, Heart Research Follow-Up Program, Box 653, University of Rochester Medical Center, 601 Elmwood Ave, Rochester, NY 14642. E-mail heartajm@heart.rochester.edu


Key Words: Editorials • death, sudden • defibrillation • heart failure • defibrillators, implantable


An extract of the first 250 words of the full text is provided, because this article has no abstract.
 

Randomized clinical trials have clearly shown that the implanted cardiac defibrillator (ICD) saves lives1–3 and that cardiac resynchronization therapy (CRT) and combined ICD and CRT devices reduce both heart failure and mortality.4–6 However, during long-term follow-up of patients with these implanted devices, only a minority will use appropriate ICD therapy for life-threatening ventricular tachyarrhythmic events. For example, in the Multicenter Automatic Defibrillator Implantation Trial II (MADIT-II), only 35% of the patients in the ICD arm received appropriate ICD therapy (shock or antitachycardia pacing) during 3-year follow-up.7 The challenge facing the medical profession is how to better identify and select patients who will benefit from implanted ICD or combined ICD and CRT devices so as to achieve greater therapeutic efficacy without losing patients. During recent years, several noninvasive and invasive electrophysiological tests have been evaluated, including signal-averaged ECG, heart rate variability, heart rate turbulence, T-wave alternans, and programmed electrophysiological testing, but the risk-stratification results from these tests have not been very encouraging. Recently, Goldenberg et al demonstrated that the ICD:conventional therapy hazard ratio in patients with advanced renal disease (blood urea nitrogen >50 mg/dL) and in good-risk patients without adverse clinical factors such as heart failure, atrial fibrillation, older age, and wide QRS complex, renal dysfunction was close to 1.0 in 35% of the ICD-treated patients, with no evident benefit from the ICD.8 The remaining 65% of the at-risk ICD-treated patients received considerably enhanced benefit from the ICD, with a 50% or greater reduction in mortality. These findings are encouraging, but . . . [Full Text of this Article]