Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2000;102:1364-1368

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lansky, A. J.
Right arrow Articles by Leon, M. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lansky, A. J.
Right arrow Articles by Leon, M. B.
Related Collections
Right arrow Restenosis
Right arrow Catheter-based coronary interventions: stents

(Circulation. 2000;102:1364.)
© 2000 American Heart Association, Inc.


Clinical Investigation and Reports

Randomized Comparison of GR-II Stent and Palmaz-Schatz Stent for Elective Treatment of Coronary Stenoses

Alexandra J. Lansky, MD; Gary S. Roubin, MD, PhD; Charles D. O’Shaughnessy; Paul B. Moore, MD; Larry S. Dean, MD; Albert E. Raizner, MD; Robert D. Safian, MD; James P. Zidar, MD; Jennifer L. Kerr, MS; Jeffrey J. Popma, MD; Roxana Mehran, MD; Richard E. Kuntz, MD; Martin B. Leon, MD; for the GR-II Randomized Clinical Trial Investigators

From Lenox Hill Hospital (A.J.L., G.S.R., R.M., M.B.L.), New York, NY; the North Ohio Heart Center (C.D.O.), Elyria; Baptist Medical Center (P.B.M.), Montgomery, Ala; the University of Alabama at Birmingham (L.S.D.); Methodist Hospital (A.E.R.), Houston, Tex; William Beaumont Hospital (R.D.S.), Royal Oak, Mich; Duke Medical Center (J.P.Z.), Durham, NC; Brigham and Women’s Hospital (J.J.P.) and Beth Israel Deaconess Hospital (R.E.K.), Boston, Mass; and MED Institute (J.L.K.), West Lafayette, Ind.


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowAppendix 1
down arrowReferences
 
Background—This prospective multicenter randomized clinical trial was designed to evaluate the long-term angiographic and clinical outcomes of elective treatment with the GR-II stent compared with the Palmaz-Schatz (PS) stent in patients with coronary stenoses.

Methods and Results—Seven hundred fifty-five patients with myocardial ischemia and de novo native coronary stenoses in 3- to 4-mm vessels were randomly assigned to the PS (375 patients) or the GR-II stent (380 patients). The primary end point was 12-month target lesion revascularization (TLR)-free survival. Angiography was performed at baseline and at follow-up in the first 300 consecutive patients to assess the frequency of angiographic restenosis. Procedure success was 98.5% for the GR-II stent and 99.4% for the PS stent (P=0.19). At 30 days, patients assigned to the GR-II stent had a higher stent thrombosis rate (3.9% versus 0.3% for PS stent, P<0.001) and TLR rate (3.9% versus 0.5% for PS stent, P<0.001). The GR-II group had a higher follow-up restenosis frequency (47.3% versus 20.6% for the PS group, P<0.001) and a lower 12-month TLR-free survival rate (71.7% versus 83.9% for the PS group, P<0.001). Multivariate logistic regression analysis identified a smaller final stent minimal lumen diameter (odds ratio [OR] 2.49, 95% CI 1.56 to 3.98; P<0.001), diabetes mellitus (OR 2.14, 95% CI 1.42 to 3.22; P<0.001), and use of the GR-II stent (OR 1.78, 95% CI 1.20 to 2.64; P<0.01) as independent determinants of 12-month TLR.

Conclusions—On the basis of these long-term follow-up data, we conclude that use of the GR-II stent should be limited to the acute treatment of abrupt or threatened closure after failed conventional balloon angioplasty procedures.


Key Words: angioplasty • stents • restenosis


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowAppendix 1
down arrowReferences
 
Prior randomized trials have shown that the Palmaz-Schatz (PS) coronary stent (Johnson and Johnson Interventional Systems) reduces the frequency of clinical and angiographic restenosis by a relative 25% to 30% in native coronary arteries compared with restenosis frequency after balloon angioplasty (PTCA).1 2 Newer second- and third-generation stents (Multi-Links, Guidant; NIR, Boston Scientific; and AVE-GFX, Medtronic-AVE) have recently been approved by the Food and Drug Administration (FDA) for the prevention of restenosis in de novo or restenotic native coronary lesions, on the basis of the proven equivalence of these newer stents to the standard PS stent. Other stents (Gianturco-Roubin Flex Stent and GR-II, Cook Inc; Wiktor, Medtronic) are approved for the treatment of abrupt or threatened closure after balloon angioplasty on the basis of superior 30-day clinical outcomes, but data comparing the late angiographic and clinical outcomes with conventional elective PS stenting are lacking.

The first-generation Gianturco-Roubin Flex Stent was initially evaluated in clinical trials in 1987. In 1993, FDA approval was granted on the basis of 30-day clinical outcome data demonstrating safety and effectiveness for the treatment of abrupt and threatened closure. The second-generation GR-II stent is an improved design, including a sheathless, balloon-expandable, flexible, coiled stent composed of a polymer-coated, single, 0.006-in, 316L stainless-steel wire that is coiled into interdigitating loops in a "clamshell" design. The coil is linked by a longitudinal spine to prevent axial stent shortening or deformation, and radiopaque gold markers at the proximal and distal ends of the stent allow easy visualization of the stent margins. The GR-II stent is available in 2 standard stent lengths (20 and 40 mm), allowing single-stent use for longer lesions. This advanced version of the GR-II stent was approved by the FDA for abrupt or threatened closure syndrome in May 1997.

The purpose of the present study was to compare the late clinical and angiographic outcomes in patients treated electively with either the GR-II stent or the PS stent in native coronary stenoses.


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowAppendix 1
down arrowReferences
 
Patient Population
Patients providing informed consent were included in the study if they had objective evidence of myocardial ischemia, a de novo native coronary lesion in a vessel between 3.0 to 4.0 mm in diameter by visual estimate, and required 1 or two 20-mm or a single 40-mm GR-II stent or 1 or two 15-mm PS stents. Lesions up to 30 mm in length were included. Patients were excluded if there was evidence of a recent (<7-day) myocardial infarction, angiographic thrombus, left ventricular ejection fraction <35%, unprotected left main disease, or unplanned stent use, such as the occurrence of a significant dissection or reduced (Thrombolysis in Myocardial Infarction [TIMI] grade 2) flow after conventional PTCA.

Adjunct Pharmacology
The protocol recommended that all patients be premedicated with aspirin (325 mg daily) and ticlopidine (250 mg twice daily) for 48 hours before the procedure. Bolus intravenous heparin was administered to maintain the activated clotting time between 250 to 350 seconds. After the stent procedure, all patients received aspirin (325 mg) indefinitely and ticlopidine (250 mg twice daily) for 4 weeks. Postprocedural administration of unfractionated heparin, low molecular weight heparin, coumadin, or antiplatelet agents were left to the discretion of the operator.

Stent Deployment Method
Predilation using conventional PTCA techniques was performed before stent implantation in all patients. For patients assigned to the PS stent, a 3.0-, 3.5-, or 4.0-mm PS stent was deployed at 6 to 8 atm with use of the stent delivery balloon to approximate a 1.1/1.0 stent-to-artery ratio. After dilatation, high-pressure (16- to 18-atm) inflation was recommended; a noncompliant PTCA balloon was used in an attempt to achieve a <10% final diameter stenosis. In patients assigned to the GR-II stent, the protocol recommended that a slightly oversized GR-II stent (0.1 to 0.5 mm larger than the reference) be selected to achieve a 1.1–1.2 to 1.0 stent–to–reference artery ratio. Only GR-II stents between 3.0, 3.5, and 4.0 mm in diameter were available for this study. The GR-II stent was deployed at 6 to 8 atm with use of the stent delivery balloon; subsequent high-pressure (14- to 16-atm) inflations were performed with the use of a semicompliant or noncompliant balloon.

Data Collection and End Points
Detailed case report forms were completed by the clinical coordinator at each site and were forwarded to the data analysis center (MED Institute, West Lafayette, Ind) after independent monitoring. Clinical follow-up was obtained at 30 days and 12 months. All adverse clinical events were adjudicated by an independent clinical events committee (CDAC, Department of Medicine, Beth Israel Hospital, Boston, Mass). All procedural and follow-up cineangiograms were obtained by using standard acquisition guidelines and were submitted to an independent Angiographic Core Laboratory (Washington Hospital Center, Washington, DC). Follow-up cineangiograms were obtained in the first 300 consecutive patients at {approx}9 months. Quantitative angiographic analysis was performed by use of the CMS-GFT system (Medis).3 Standard morphological criteria were used to characterize baseline lesion complexity4 and to identify the occurrence of angiographic complications.5

The prespecified primary end point of the trial was the 12-month target lesion revascularization (TLR)-free survival. Secondary end points included procedure success, defined as the attainment of <50% diameter stenosis in the absence of death or emergent bypass surgery, stent thrombosis, and major adverse cardiac events, including death, myocardial infarction, and TLR at 30 days and 12 months. Myocardial infarction was defined as a rise in total creatinine kinase >2 times normal with a positive MB fraction in association with any of the following criteria: (1) ischemic chest pain lasting >30 minutes, (2) a new 2-step Minnesota Code Q wave, (3) persistent ST- or T-wave changes, or (4) a new left bundle branch block. Stent thrombosis was defined as an angiographically or clinically documented coronary occlusion (TIMI grade 0 flow) at the stent site or cardiac death within 30 days of the procedure. The secondary angiographic end point was the restenosis frequency, defined as a >50% follow-up diameter stenosis within the stent. The mean reference diameter (RD) and the minimal lumen diameter (MLD) within the axial stent length were used to calculate the percent diameter stenosis, defined as (1-MLD/RD)x100, within the stent. MLD 0.0 was imputed in the presence of a total occlusion at baseline or follow-up. Acute gain (in millimeters) was defined as the change in the stent MLD from baseline to the final procedural angiogram; late loss (in millimeters) was defined as the change in stent MLD from the final to the follow-up angiogram. The regression loss index within the stent was defined as the regression coefficient of the relationship between late loss (y-axis) and acute gain (x-axis). Stent recoil, defined as (final balloon MLD-final stent MLD)/RD, was measured as an index of the maximal loss in lumen dimensions resulting from the final balloon deflation.6

Statistical Analysis
The sample size determination for this trial was based on the equivalency methods of Blackwelder and Chang.7 8 The null hypothesis for the study was that 12-month TLR-free survival rate was at least 8% lower or higher for patients treated with the GR-II stent than for those treated with the PS stent. The alternate hypothesis was that the difference in 12-month TLR-free survival rates between the 2 groups was <8%. With an estimated 85% 12-month TLR-free survival rate in PS stent–treated patients, 341 patients (682 total patients) would be required per arm to achieve a statistical power of 90% with a type I ({alpha}) error of 0.05. Assuming a 10% dropout rate due to patient loss to clinical follow-up, 750 patients were required for the present study.

Patient outcomes were analyzed by using an "intention-to-treat" analysis. Continuous variables are reported as mean±SD, and all binary and ordinal variables are presented as frequencies. Comparisons between patients treated with the GR-II stent and the PS stent were performed by use of t tests or Wilcoxon nonparametric tests for continuous variables; ordinal variables were compared by {chi}2 analysis or the Fisher exact test. Multivariable logistic analyses were performed to identify clinical and angiographic predictors of (1) 30-day stent thrombosis, (2) 12-month TLR, and (3) angiographic restenosis. Variables included in the model were reference vessel size, location of the left anterior descending coronary artery, lesion length, final MLD, stent length–to–lesion length ratio, total length of implanted stent, stent-to-artery ratio, GR-II stent use, diabetes mellitus, and "incorrect" GR-II stent sizing (undersized and oversized). Binary stepwise multivariate logistic regression analysis used a value of P<0.10 for entry and P<0.20 for removal. A 2-tailed value of P<0.05 was considered significant.


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowAppendix 1
down arrowReferences
 
Procedural Findings
Between January and October 1996, 755 patients at 31 clinical sites (Appendix) were randomly assigned to elective stent placement with the GR-II stent (380 patients) or the PS stent (375 patients). Six patients in the GR-II stent group and 7 in the PS stent group had failed stent deployment and did not receive a stent or received an alternate stent. Baseline clinical demographics and lesion characteristics were similar in the 2 groups (Table 1Down). On average, the PS stent group had more stents implanted per lesion (1.47±0.72 versus 1.27±0.57 for GR-II, P<0.001), but the total length of stent material implanted was greater in patients treated with the GR-II stent (29.3±15.1 versus 22.0±10.9 mm for the PS stent, P<0.001), and as a result, the ratio of stent to lesion length was significantly higher for the GR-II group (2.5 versus 1.9 for the PS group, P<0.001). Correct GR-II stent sizing, as defined by the protocol, was achieved in only 41.2% of cases, and of the 58.8% incorrectly sized GR-II stents, 20% were undersized and 38.8% were oversized when angiographic core laboratory measures of reference vessel diameter were used. The GR-II stent group had a lower stent-to-artery ratio (1.02±0.12 versus 1.06±0.12 for the PS stent group, P<0.001) and more stent recoil (17.9±12.4% versus 11.2±14.2% for the PS stent group, P<0.001), despite a tendency for a higher final balloon-to-artery ratio (1.16±0.16 versus 1.14±0.17 for the PS stent group, P=0.06). GR-II patients had a higher final stent percent diameter stenosis (15.6±10.7% versus 9.8±10.5 for PS patients, P<0.001; Table 2Down) and more final American College of Cardiology/American Heart Association grade B dissections (18.2% versus 8.0% for PS patients, P<0.001). Procedural success was 98.5% for the GR-II stent group and 99.4% for the PS stent group (P=0.188).


View this table:
[in this window]
[in a new window]
 
Table 1. Baseline Clinical and Angiographic Characteristics


View this table:
[in this window]
[in a new window]
 
Table 2. Quantitative Angiographic Results

Early Clinical Outcomes
At 30 days, composite major adverse cardiac events were significantly higher in the GR-II stent group (P=0.029) because of a higher need for 30-day TLR (P<0.01) and a higher incidence of stent thrombosis (P<0.001) (Table 3Down). By multivariate logistic regression analysis, a low stent-to-artery ratio (odds ratio [OR] 0.006, 95% CI 0.00 to 0.14; P<0.01), use of the GR-II stent (OR 13.56, 95% CI 1.58 to 116.06; P=0.02), and the presence of diabetes (OR 3.13, 95% CI 1.01 to 9.65; P<0.05) were independent determinants of 30-day stent thrombosis. In addition, incorrect GR-II stent sizing was a univariate predictor of stent thrombosis (OR 8.22, P=0.04). Mortality was low in both the GR-II (0.3%) and the PS (0.5%) stent groups.


View this table:
[in this window]
[in a new window]
 
Table 3. Clinical Outcome

Late Clinical Outcomes
Complete 12-month clinical follow-up was available in 97.1% of the GR-II patients (6 patients were lost to follow-up, and 5 patients were not treated) and in 97.6% of the PS patients (6 patients were lost to follow-up, and 3 patients were not treated) (Table 3Up). The primary end point of the study, 12-month TLR-free survival rate, was significantly lower for the GR-II stent group than for the PS stent group (71.7% versus 83.9%, respectively; P<0.001) (Figure 1Down). Multivariate logistic regression analysis identified a smaller final stent MLD (OR 2.49, 95% CI 1.56 to 3.98; P<0.001), diabetes mellitus (OR 2.14, 95% CI 1.42 to 3.22; P<0.001), and use of the GR-II stent (OR 1.78, 95% CI 1.20 to 2.64; P<0.01) as independent determinants of TLR. Major adverse cardiac events at 12 months were significantly higher in the GR-II arm because of a greater need for TLR (P<0.001). TLR rates tended to be higher for patients with oversized (27.9%) and undersized (26.0%) compared with correctly sized (24.2%) GR-II stent selection, and site-to-site variability in 12-month TLR was substantially greater in the GR-II–treated patients.



View larger version (17K):
[in this window]
[in a new window]
 
Figure 1. TLR-free survival: Kaplan-Meier estimate of overall survival free of TLR. Freedom from TLR at 12 months was 71.7% for GR-II stent vs 83.9% for PS stent (P<0.001).

Follow-Up Angiographic Findings
Follow-up angiography was available in 217 of the 306 prespecified patients (72% of GR-II and 70% of PS stent patients) (Table 2Up). The follow-up stent MLD was significantly lower and the percent diameter stenosis was significantly higher in the GR-II–treated patients (Figure 2Down). Use of the GR-II stent was associated with a lower acute gain, a higher late loss, and a higher loss index. The angiographic restenosis rate was significantly higher in GR-II–treated patients (47.3% versus 20.6% for PS-treated patents, P<0.001). Multivariate logistic regression analysis identified the preprocedural MLD (OR 3.36, 95% CI 1.42 to 7.69; P<0.01), use of the GR-II stent (OR 3.24, 95% CI 1.69 to 6.24; P<0.001), diabetes mellitus (OR 2.46, 95% CI 1.20 to 5.05; P=0.014), and longer lesion length (OR 1.06, 95% CI 1.02 to 1.10; P=0.003) as independent determinants of restenosis. Total stent length was a univariate (OR 10.43, P<0.001) but not a multivariate predictor of restenosis.



View larger version (28K):
[in this window]
[in a new window]
 
Figure 2. Cumulative distribution curves for MLD at baseline, final procedure, and 9-month follow-up in patients randomized to GR-II and PS stent. MLDs at baseline are similar in both groups; however, final procedure MLDs (2.64±0.41 mm for GR-II stent vs 2.83±0.43 mm for PS stent, P<0.001) and follow-up MLDs (1.48±0.73 mm for GR-II stent vs 1.90±0.74 mm for PS stent, P<0.001) were significantly smaller for GR-II–treated patients.


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowAppendix 1
down arrowReferences
 
In the present study comparing elective stent treatment of native coronary stenoses, patients treated with the GR-II stent had more early complications (stent thrombosis and 30-day composite events) and higher late angiographic and clinical restenosis rates than did the patients treated with the PS stent. Independent predictors of 12-month TLR-free survival (the primary end point of this randomized trial) were a smaller final MLD, diabetes mellitus, and implantation of a GR-II stent.

The likely explanation for increased early complications associated with the GR-II stent in this clinical trial is the reduced stent-to-artery ratio resulting from (1) increased acute recoil of this coiled stent design and (2) implantation of undersized stents (an operator-dependent variable). Other studies have demonstrated that small stent size and incompletely expanded stents are important predictors of subacute stent thrombosis.9

There are a number of potential (and perhaps interrelated) reasons for the disappointing late outcomes of the GR-II stent compared with the PS stent. First, late patient outcomes (both angiographic restenosis and TLR) are strongly influenced by the acute angiographic results after any coronary intervention.10 In the present study, the final angiographic diameter stenosis was considerably higher in patients treated with GR-II stents (15.6% versus 9.8% for PS patients, P<0.001). The design of the GR-II stent is different from most other tubular-slotted and multicellular stents; there is more acute stent recoil, and there is more open space between stent struts, allowing increased tissue prolapse. Thus, implanting GR-II stents with a technique similar to that used for PS stents resulted in higher final diameter stenoses and worsened overall late outcomes in the GR-II stent patients. The problem was compounded by operator undersizing of the GR-II stents in the present study (20% of cases when vessel size was assessed quantitatively and an even greater number according to investigator estimates of reference vessel size). Previous studies have emphasized the importance of avoiding GR-II stent undersizing.9 Second, the stent lengths available for the present study inadvertently resulted in a much higher total stent length and stent length–to–lesion length ratio for the GR-II stent (29.3 versus 22.0 mm for the PS stent [P<0.001] and 2.5 versus 1.5 for the PS stent [P<0.001], respectively). In this trial and others, stent length has been an important predictor of late angiographic and clinical restenosis. Third, as with any new device, operator technique is critical for achieving optimal results.11 There was a marked site-to-site variability in long-term patient outcomes in the GR-II group, a finding not seen in the PS stent group. It is possible that a different stent implantation technique (ie, a larger balloon-to-artery ratio to offset the acute recoil and tissue prolapse, resulting in lower final procedural diameter stenoses) would have produced better results in the GR-II arm of the present study. In 2 other randomized clinical trials (albeit in patients with acute myocardial infarction) comparing the GR-II stent with balloon angioplasty (the GR II Stent in Acute Myocardial Infarction [GRAMI] and the Florence Randomized Elective Stenting in Acute Coronary Occlusion [FRESCO] trials), the long-term patient outcomes in the stent groups were significantly better than the long-term outcomes in the present study.12 13 The present study cannot address the mechanism of increased late lumen renarrowing in patients treated with GR-II stents. Serial intravascular ultrasound studies have shown that late stent recoil is minimal with tubular slotted stents and that intimal hyperplasia is the dominant contributor to late lumen renarrowing in patients with PS stents.14 Because late lumen loss and loss index were higher in the patients treated with the GR-II stent, it is clear that there was either late mechanical recoil of the GR-II coil stent, increased intimal hyperplasia (or late tissue prolapse), or a combination of both.

Study Limitations
Limitations of the present study include the inherent differences in stent lengths between the GR-II and the PS stents, making a precise comparison problematic. In addition, inconsistencies in operator technique and infrequent optimal GR-II size selection resulted in pronounced intersite TLR variability. Because greater variability was noted in the GR-II–treated patients, a "roll in" learning phase may have reduced some of the observed differences. Perhaps these issues should serve as an important lesson for future randomized clinical trials. Appropriate interdevice comparisons require that operator technique factors relating to new devices be completely understood and consistently applied by investigators before embarking on definitive randomized controlled clinical trials. In this context, it may be appropriate for the FDA to require sponsors to demonstrate optimal device use and technique by the investigators before approving the initiation of large-scale randomized clinical trials and the release of new devices.

We conclude that in patients undergoing elective stent placement in de novo native coronary lesions, the GR-II coronary stent is associated with higher stent thrombosis, angiographic restenosis, and late TLR rates.


*    Footnotes
 
Reprint requests to Martin B. Leon, MD, Cardiovascular Research Foundation, 55 E 59th St, 6th Floor, New York, NY 10022.

Dr Roubin was a compensated consultant to Cook, Inc (manufacturer of the GR-II stent) from 1994 to 1999.

Guest Editor for this article was Spencer B. King III, MD, Emory University, Atlanta, Ga.


*    Appendix 1
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*Appendix 1
down arrowReferences
 
The following investigators were participants in the clinical trial: Arizona Heart Institute and Foundation, Phoenix, R.R. Heuser; Montgomery Cardiovascular, Montgomery, Ala, P.B. Moore; Beth Israel Hospital, Boston, Mass, J.P. Carrozza, Jr; Brigham and Women’s Hospital, Boston, Mass, J.A. Bittl; Lindner Center for Cardiovascular Research, Cincinnati, Ohio, D.J. Kereiakes; The Cleveland Clinical Foundation, Cleveland, Ohio, S.G. Ellis; Duke North Hospital, Durham, NC, J.P. Zidar; North Ohio Heart Center, Elyria, C.D. O’Shaughnessy; Iowa Heart Center, Des Moines, L.A. Iannone; Johns Hopkins Hospital, Baltimore, Md, J.A. Brinker; Lenox Hill Hospital, New York, NY, J.W. Moses; Loma Linda Hospital, Los Angeles, Calif, C.E. Ruiz; Mayo Clinic Foundation, Rochester, Minn, D.R. Holmes; The Methodist Hospital, Houston, Tex, A.E. Raizner; Mid-Carolina Cardiology, Charlotte, NC, D.A. Cox; Midwest Cardiology Research Foundation, Columbus, Ohio, S.J. Yakubov and B.S. George; Prairie Cardiovascular Consultants, Ltd, Springfield, Ill, K. Rocha-Singh; Rhode Island Hospital, Providence, D.O. Williams; Rochester General Hospital, Rochester, NY, M.A. Thompson; Sacred Heart Hospital, Pensacola, Fla, E.W. Rogers; St. Joseph Hospital, Atlanta, Ga, W.D. Knoff; St. Luke’s Hospital, Milwaukee, Wis, G. Dorros; St. Vincent Hospital, Indianapolis, Ind, E.T.A. Fry and J.B. Hermiller; Sanger Clinic, PA, Charlotte, NC, C.A. Simonton; Summitt Cardiology, Seattle, Wash, D. Warth; Medical College of Ohio at Toledo, C.J. Cooper; University of Alabama at Birmingham, L.S. Dean and G.S. Roubin; University Hospital, Tampa, Fla, R.E. Bowerman; Vancouver Hospital and Health Science Center, Vancouver, BC, I.M. Penn; Washington Hospital Center, Washington, DC, M.B. Leon; and William Beaumont Hospital, Royal Oak, Mich, R.D. Safian.

Received August 19, 1999; revision received April 14, 2000; accepted April 27, 2000.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
up arrowAppendix 1
*References
 
1. Fischman DL, Leon MB, Baim DS, et al. A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease. N Engl J Med. 1994;331:496–501.[Abstract/Free Full Text]

2. Serruys PW, de Jaegere P, Kiemeneij F, et al. A comparison of balloon expandable stent implantation with balloon angioplasty in patients with coronary artery disease. N Engl J Med. 1994;331:489–495.[Abstract/Free Full Text]

3. van der Zwet PH, Reiber JH. A new approach for the quantification of complex lesion morphology: the gradient field transform: basic principles and validation results. J Am Coll Cardiol. 1994;24:216–224.[Abstract]

4. Ellis S, Vandormael M, Cowley M, et al. Coronary morphologic and clinical determinants of procedural outcome with angioplasty for multivessel coronary disease. Circulation. 1990;82:1193–1202.[Abstract/Free Full Text]

5. Lansky A, Popma J. Qualitative and quantitative angiography. In: Topol EJ, ed. Textbook of Interventional Cardiology. 3rd ed. Philadelphia, Pa: WB Saunders Co; 1998:725–748.

6. Popma J, Bashore T. Qualitative and quantitative angiography. In: Topol EJ, ed. Textbook of Interventional Cardiology. 3rd ed. Philadelphia, Pa: WB Saunders Co; 1994:1052–1068.

7. Blackwelder W. "Proving the null hypothesis" in clinical trials. Control Clin Trials. 1982;3:345–353.[Medline] [Order article via Infotrieve]

8. Blackwelder W, Chang M. Sample size graphs for "proving the null hypothesis." Control Clin Trials. 1984;5:97–105.[Medline] [Order article via Infotrieve]

9. Lansky A, Curran M, Hanzel G, et al. The impact of stent size selection on clinical outcome after use of the Gianturco Roubin II stent: results from the randomized clinical trial. Circulation. 1998;98(suppl I):I-160–I-161.

10. Kuntz R, Safian R, Carrozza J, et al. The importance of acute luminal diameter in determining restenosis after coronary atherectomy or stenting. Circulation. 1992;86:1827–1835.[Abstract/Free Full Text]

11. Schatz R, Baim D, Leon M, et al. Clinical experience with the Palmaz-Schatz coronary stent: initial results of a multicenter study. Circulation. 1991;83:148–161.[Abstract/Free Full Text]

12. Antoniucci D, Santoro G, Bolognese L, et al. A clinical trial comparing primary stenting of the infarct-related artery with optimal primary angioplasty for acute myocardial infarction: results from the Florence Randomized Elective Stenting in Acute Coronary Occlusion (FRESCO) trial. J Am Coll Cardiol. 1998;31:1234–1239.[Abstract/Free Full Text]

13. Rodrigez A, Bernardi V, Santaera C, et al. Coronary stents improve outcome in acute myocardial infarction: immediate and long term results of the GRAMI trial. J Am Coll Cardiol. 1998;31:64A. Abstract.

14. Painter J, Mintz G, Wong C, et al. Serial intravascular ultrasound studies fail to show evidence of chronic Palmaz-Schatz stent recoil. Am J Cardiol. 1995;75:398–400.[Medline] [Order article via Infotrieve]




This article has been cited by other articles:


Home page
CirculationHome page
L. Mauri, E. J. Orav, S. C. Candia, D. E. Cutlip, and R. E. Kuntz
Robustness of Late Lumen Loss in Discriminating Drug-Eluting Stents Across Variable Observational and Randomized Trials
Circulation, November 1, 2005; 112(18): 2833 - 2839.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. E. Rodriguez, J. Baldi, C. F. Pereira, J. Navia, M. R. Alemparte, A. Delacasa, F. Vigo, D. Vogel, W. O'Neill, I. F. Palacios, et al.
Five-Year Follow-Up of the Argentine Randomized Trial of Coronary Angioplasty With Stenting Versus Coronary Bypass Surgery in Patients With Multiple Vessel Disease (ERACI II)
J. Am. Coll. Cardiol., August 16, 2005; 46(4): 582 - 588.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Pathol.Home page
J Butany, K Carmichael, S W Leong, and M J Collins
Coronary artery stents: identification and evaluation
J. Clin. Pathol., August 1, 2005; 58(8): 795 - 804.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
J. Pache, A. Dibra, J. Mehilli, J. Dirschinger, A. Schomig, and A. Kastrati
Drug-eluting stents compared with thin-strut bare stents for the reduction of restenosis: a prospective, randomized trial
Eur. Heart J., July 1, 2005; 26(13): 1262 - 1268.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
L. Mauri, E. J. Orav, and R. E. Kuntz
Late Loss in Lumen Diameter and Binary Restenosis for Drug-Eluting Stent Comparison
Circulation, June 28, 2005; 111(25): 3435 - 3442.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
L. Mauri, E. J. Orav, A. J. O'Malley, J. W. Moses, M. B. Leon, D. R. Holmes Jr, P. S. Teirstein, J. Schofer, G. Breithardt, D. E. Cutlip, et al.
Relationship of Late Loss in Lumen Diameter to Coronary Restenosis in Sirolimus-Eluting Stents
Circulation, January 25, 2005; 111(3): 321 - 327.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. Mehran, G. D. Dangas, Y. Kobayashi, A. J. Lansky, G. S. Mintz, E. D. Aymong, M. Fahy, J. W. Moses, G. W. Stone, and M. B. Leon
Short- and long-term results after multivessel stenting in diabetic patients
J. Am. Coll. Cardiol., April 21, 2004; 43(8): 1348 - 1354.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
A. J Nordmann, P. Hengstler, B. M Leimenstoll, T. Harr, J. Young, and H. C Bucher
Clinical outcomes of stents versus balloon angioplasty in non-acute coronary artery disease: A meta-analysis of randomized controlled trials
Eur. Heart J., January 1, 2004; 25(1): 69 - 80.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J.u. Pache, A. Kastrati, J. Mehilli, H. Schuhlen, F. Dotzer, J.o. Hausleiter, M. Fleckenstein, F.-J. Neumann, U. Sattelberger, C. Schmitt, et al.
Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial
J. Am. Coll. Cardiol., April 16, 2003; 41(8): 1283 - 1288.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. B. Berger
Can euphoria be bad?
J. Am. Coll. Cardiol., April 16, 2003; 41(8): 1289 - 1292.
[Full Text] [PDF]


Home page
HeartHome page
A Rodriguez, M Rodriguez Alemparte, J Baldi, J Navia, A Delacasa, D Vogel, R Oliveri, C Fernandez Pereira, V Bernardi, W O'Neill, et al.
Coronary stenting versus coronary bypass surgery in patients with multiple vessel disease and significant proximal LAD stenosis: results from the ERACI II study
Heart, February 1, 2003; 89(2): 184 - 188.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. Colombo, G. Stankovic, and J. W. Moses
Selection of coronary stents
J. Am. Coll. Cardiol., September 18, 2002; 40(6): 1021 - 1033.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J.o. Hausleiter, A. Kastrati, J. Mehilli, H. Schuhlen, J.u. Pache, F. Dotzer, J. Dirschinger, and A. Schomig
Predictive factors for early cardiac events and angiographic restenosis after coronary stent placement in small coronary arteries
J. Am. Coll. Cardiol., September 4, 2002; 40(5): 882 - 889.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. Kastrati, H. Schuhlen, and A. Schomig
Stenting for small coronary vessels: a contestable winner
J. Am. Coll. Cardiol., November 15, 2001; 38(6): 1604 - 1607.
[Full Text] [PDF]


Home page
CirculationHome page
A. Kastrati, J. Mehilli, J. Dirschinger, F. Dotzer, H. Schuhlen, F.-J. Neumann, M. Fleckenstein, C. Pfafferott, M. Seyfarth, and A. Schomig
Intracoronary Stenting and Angiographic Results : Strut Thickness Effect on Restenosis Outcome (ISAR-STEREO) Trial
Circulation, June 12, 2001; 103(23): 2816 - 2821.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. L. Goldberg, A. Loussararian, J. De Gregorio, C. Di Mario, R. Albiero, and A. Colombo
Predictors of diffuse and aggressive intra-stent restenosis
J. Am. Coll. Cardiol., March 15, 2001; 37(4): 1019 - 1025.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
K. E. Kip, E. L. Alderman, M. G. Bourassa, M. M. Brooks, L. Schwartz, D. R. Holmes Jr, R. M. Califf, P. L. Whitlow, B. R. Chaitman, and K. M. Detre
Differential Influence of Diabetes Mellitus on Increased Jeopardized Myocardium After Initial Angioplasty or Bypass Surgery: Bypass Angioplasty Revascularization Investigation
Circulation, April 23, 2002; 105(16): 1914 - 1920.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lansky, A. J.
Right arrow Articles by Leon, M. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lansky, A. J.
Right arrow Articles by Leon, M. B.
Related Collections
Right arrow Restenosis
Right arrow Catheter-based coronary interventions: stents