Change in Character of Mitral Prosthesis Regurgitant Murmur With Bundle-Branch Block
Correlation of Auscultatory and Echocardiographic Findings
Elizabeth W. Ryan, MBBS;
Elyse Foster, MD
From the University California, San Francisco.
Correspondence to Elyse Foster, MD, FACC, Director, Adult Echocardiography Laboratory, University of California, San Francisco, 505 Parnassus Ave, M314, San Francisco, CA 94143-0214. E-mail foster{at}medicine.ucsf.edu (Circulation. 2001;103:1715-1716.)
Key Words: mitral valve regurgitation echocardiography prosthesis murmur
This 75-year-old
woman, in whom a Carpentier Edwards porcine mitral valve prosthesis
(No. 29) had been implanted in 1990, presented with episodic
breathlessness and dizziness. Examination revealed an apical
pansystolic murmur with a frequent but intermittent loud musical
"honking" character. The patient was in sinus rhythm, 68 to 74 bpm,
with alternating runs of narrow QRS and bundle-branch block. The
amplified, honking quality was observed intermittently only during
periods of narrow QRS complexes.
Echocardiography revealed thickened prosthesis
leaflets, a 3-mm vibrating density
(Figure 1
) on the leaflets atrial surface, and a 2-mm
systolic coaptation defect with prosthesis regurgitation. The
regurgitant jet was eccentric, directed anteriorly and toward the left
atrial appendage. Regurgitation was graded as moderate. Mitral inflow
velocities were mildly elevated (peak E 1.3 m/s, peak A 1.8 m/s, and
mean gradient 6.6 mm Hg), with a pressure half-time of 123 ms,
indicative of minimal prosthesis stenosis. Systolic vibration is noted
on M-mode echocardiography of the mitral prosthesis
(Figure 2
) associated with marked aliasing of color
(Figures 3
and 4
) corresponding to the honking murmur.
Increased density of the continuous-wave spectral Doppler
(Figure 4
) is also noted in conjunction with the intermittent
honking murmur.

View larger version (127K):
[in this window]
[in a new window]
|
Figure 1. Transesophageal image of porcine mitral prosthesis. Arrow indicates a vibratory mass on atrial side of prosthesis. LA indicates left atrium; LV, left ventricle.
|
|

View larger version (81K):
[in this window]
[in a new window]
|
Figure 2. Transthoracic M-mode recording of mitral prosthesis. Arrows indicate systolic vibration of leaflets. LA indicates left atrium; MV, mitral valve prosthesis leaflets.
|
|

View larger version (43K):
[in this window]
[in a new window]
|
Figure 3. Transthoracic parasternal views showing mitral prosthesis regurgitation. Left image was obtained during bundle-branch block conduction. Image on right shows marked aliasing of color correlated with honking murmur and narrow QRS complexes. LV indicates left ventricle; Ao, aorta; and MR, mitral regurgitation.
|
|

View larger version (85K):
[in this window]
[in a new window]
|
Figure 4. Transthoracic spectral Doppler patterns (top) and color M-mode recordings (bottom) of mitral prosthesis. Images on right correlated with honking characteristic of regurgitant murmur. Increased density of Doppler signal (top right) and marked aliasing of color (bottom right) are noted compared with recordings when murmur did not have a honking quality (left). LA indicates left atrium.
|
|