Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2001;104:1999-2002
doi: 10.1161/hc4201.099224
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Al-Mubarak, N.
Right arrow Articles by Leon, M. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Al-Mubarak, N.
Right arrow Articles by Leon, M. B.
Related Collections
Right arrow Carotid Stenosis
Right arrow Embolic stroke
Right arrow Doppler ultrasound, Transcranial Doppler etc.
Right arrow Pathology of Stroke
Right arrow Angioplasty and Stenting

(Circulation. 2001;104:1999-2002.)
© 2001 American Heart Association, Inc.


Brief Rapid Communications

Effect of the Distal-Balloon Protection System on Microembolization During Carotid Stenting

Nadim Al-Mubarak, MD; Gary S. Roubin, MD PhD; Jiri J. Vitek, MD PhD; Sriram S. Iyer, MD; Gishel New, MD; Martin B. Leon, MD

From Lenox Hill Heart and Vascular Institute, New York, NY.

Correspondence to Gary S. Roubin, MD, PhD, 130 East 77th Street, New York, NY 10021. E-mail Groubin{at}lenoxhill.net

Received July 23, 2001; revision received September 7, 2001; accepted September 10, 2001.


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Background— The distal-balloon protection system is being evaluated for its efficacy in preventing embolic neurological events during carotid stenting (CAS). We sought to determine the effect of this system on the frequency of Doppler-detected microembolic signals (MES) during CAS.

Methods and Results— Using transcranial Doppler, we compared the frequency of MES during CAS in 2 groups: 39 patients without distal protection and 37 who used the distal-balloon protection system (GuardWire). There were no significant differences in the clinical or angiographic characteristics between the 2 groups. Three phases with increased MES counts were identified during unprotected CAS; these were stent deployment, predilation, and postdilation (75±57, 32±36, and 27±25 METS, respectively). The distal-balloon protection significantly reduced the frequency of MES during CAS (MES counts: 164±108 in the control versus 68±83 in the protection group; P=0.002), particularly during these 3 phases. MES in the protection group were detected predominantly during sheath placement, guidewire manipulation, and distal-balloon deflation.

Conclusion— Three phases with increased MES counts were identified during unprotected CAS (eg, stent deployment, predilation, and postdilation). The distal-balloon protection system significantly reduced the frequency of MES during CAS, particularly during these 3 phases.


Key Words: carotid arteries • angioplasty • stents • revascularization • embolism


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Carotid stenting (CAS) has emerged as an endovascular treatment for obstructive extracranial carotid artery disease.13 Initial reports suggest favorable efficacy in preventing stroke, and randomized trials are being commenced to compare its outcome to carotid endarterectomy.4 Despite advanced stenting techniques, neurological events linked to the embolization of particulate material in the cerebral circulation occur in {approx}5% of the cases.13,5 Efforts are ongoing to optimize the outcome of this treatment by developing strategies that eliminate the risk of embolic events.5 One such strategy is distal-balloon protection.6 By occluding the distal carotid artery with a balloon, embolic material released during the intervention is contained within the proximal blood column, which is subsequently aspirated before the protective balloon is deflated.

Transcranial Doppler studies have documented the prevalence of microembolization during unprotected CAS.7,8 Subclinical microemboli produce characteristic Doppler signals (microembolic signals, MES) that, in a variety of clinical conditions, correlate with increased risk for embolic neurological events.810 Thus, MES may serve as a surrogate marker of embolic events during CAS and facilitate the assessment of various distal-protection strategies. The higher frequency of MES compared with the clinical events in this setting allows such an assessment in a smaller number of patients.7,8 In this study, we evaluated the effect of distal-balloon protection on the frequency of the Doppler-detected MES during CAS.


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Study Population
The frequency of MES during CAS was assessed in 76 patients undergoing the procedure; 39 had no distal protection (control group), and 37 were treated with distal-balloon protection (GuardWire, Percusurge; protection group). The control group included participants of a prospective registry investigating the efficacy of CAS (January 1999 to April 2000) and preceded the enrollment of the protection group (May 2000 to November 2000), which was part of a trial investigating the feasibility of the GuardWire system during CAS (Carotid Angioplasty Free of Emboli, CAFÉ-USA). The enrollment criteria for both groups were identical and included symptomatic or asymptomatic patients with a stenosis in the internal carotid artery of ≥60% or ≥80% diameter obstruction, respectively, as determined by quantitative angiography (Phillips Integris) using the methodology from the North American Symptomatic Carotid Endarterectomy Trial (NASCET).11 Consecutive patients enrolled into either of the 2 protocols at our institution who had an optimal Doppler insonation window and who were cooperative with the transcranial Doppler monitoring procedure were enrolled in the present study.

Stenting Protocol
All procedures were performed in accordance with the guidelines of the Institutional Review Board. CAS was performed using the standard technique, as previously described.12 All patients were given 75 mg of clopidogrel (Plavix, Pfizer Inc) once a day and 325 mg of aspirin twice a day for 7 days before the procedure. A bolus of heparin (4000 U) was administered during the procedure. Glycoprotein IIb/IIIa antagonists were administered at the operator’s discretion. The GuardWire system was applied as previously described using a single-stage distal-balloon inflation with only-aspiration technique.6

Transcranial Doppler Protocol
Transcranial Doppler signals, using a multichannel system (EME-Pioneer-4040, Nicollet-Vascular), were recorded from the ipsilateral middle cerebral artery via the transtemporal window. Monitoring was started before the procedure and continued for 10 minutes after the procedure whenever possible. Standard settings were used, with 2 sample volumes of 10-mm in diameter, each at a depth of 46 to 56 mm (4 to 6 mm apart). Data were stored on a hard disk using a coding system and were analyzed off-line on a later day by an investigator who was blinded to patient information. MES were identified according to the recommended guidelines.13 The procedure was divided into the following phases: (1) sheath placement, (2) wiring, (3) predilation, (4) stent deployment, (5) postdilation, (6) aspiration phase (protection group only), and (7) angiography. These phases were defined from the time the respective catheter was introduced into the guiding sheath until it was removed.

Statistical Analysis
MES counts are expressed as mean±SD. By convention, 1 second of microembolic shower signal is considered 10 MES.7 All MES recorded during contrast injections were excluded from the analysis because they may indicate microbubbles, which may be less hazardous than solids.14 Data were compared using {chi}2 for categorical and Student’s t test for continuous variables.


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowReferences
 
Table 1 summarizes the baseline clinical characteristics. Except for history of prior carotid endarterectomy (22% in the control group versus 3% in the protection group), there were no significant differences in the age, sex, or clinical comorbidities between the 2 groups. Symptoms attributable to the treated artery occurring within 3 months before CAS were present in 26% of the control group and 28% of the protection group (P=NS).


View this table:
[in this window]
[in a new window]
 
Table 1. Patient Clinical Characteristics

Table 2 summarizes the angiographic and procedural data. There were no significant differences in angiographic lesion characteristics or residual stenosis between the 2 groups. A bolus of a glycoprotein IIb/IIIa antagonist (Aggrastat, Pfizer Inc.) was administered to 4 patients in the control group and 1 patient in the protection group. Self-expanding stents were used in all patients. The Wallstent (Boston Scientific) was used exclusively in the protection group but in only 49% of patients in the control group.


View this table:
[in this window]
[in a new window]
 
Table 2. Procedural Data

Two procedural, nondisabling embolic strokes occurred, one in each group. Both improved completely within 3 days. One patient in the protection group died 2 days after CAS from a subarachnoidal hemorrhage complicating hyperperfusion syndrome that developed immediately after intervention. His procedure was technically uncomplicated and notable for its low MES count.15 Baseline head MRI showed multiple lacunar infarctions but no acute ischemic changes. At 30 days, there have been no additional neurological events and no deaths in either group.

Microembolic Signals
MES were detected during all procedural phases in both groups (Table 3). Three phases with increased MES counts were identified in the control group; these were stent deployment, predilation, and postdilation (Figure 1). The GuardWire significantly reduced the total MES count compared with the control group (68±83 versus 164±108 MES; P=0.002), particularly during these 3 phases (Table 3). The combined MES count during the unprotected phases of the procedure (sheath placement and wire manipulation) was 30±24 in control group, and 34±41 in the protection group (P=NS). In the protection group, MES occurred predominantly during sheath placement, wire manipulation, and distal balloon deflation (Table 3). During the postprocedural observation period (mean, 9±5 minutes), no MES were detected in any of the patients.


View this table:
[in this window]
[in a new window]
 
Table 3. MES Counts



View larger version (41K):
[in this window]
[in a new window]
 
Figure 1. Microembolic profile during unprotected CAS. The mean MES counts during various phases of the procedure are displayed.

On further analysis of the control group, there was no significant difference in the MES counts between the patients who had a Wallstent versus those who had other self-expanding stents (156±93 versus 170±101 MES, respectively; P=NS). A significant difference was absent throughout the various steps, including the stenting phase (67±55 versus 78±63 MES; P=NS). Both subgroups were matched in their clinical and angiographic characteristics.


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowReferences
 
Preliminary results of the clinical evaluation of distal-balloon protection during CAS suggest that this strategy is associated with a favorable low rate of embolic stroke.6 In the present study, the use of distal-balloon protection during CAS was associated with significantly lower MES counts compared with no protection. This finding supports the clinical efficacy of this protection strategy. Further, the study defines the Doppler microembolic profile during CAS and describes the impact of distal-balloon protection on MES counts during the various procedural steps. Three critical phases are responsible for increased MES counts during the unprotected CAS: stent deployment, predilation, and postdilation, with the highest counts observed during stent deployment. This contradicts the general belief that stent deployment is associated with low embolic risk due to the scaffolding effect of the stent, which traps atherosclerotic debris against the arterial wall. It is possible that the sheer forces of the self-expanding stent, which is usually oversized to the artery, are responsible for the increased emboli release. In the protection group, MES counts were significantly reduced during these 3 critical phases. Our data also suggest that the unprotected phases (eg, sheath placement, wire manipulation, and the immediate postprocedural period) are associated with a relatively low risk of embolization.

Several factors may have contributed to the MES observed in the protection group. These include (1) a nonocclusive distal balloon; (2) embolization via the external carotid artery (Figure 2), which questions the suitability of the saline-flushing maneuver into the internal carotid artery before the distal-balloon deflation, diverting potential emboli into the external carotid artery6; and (3) trapped emboli within the "shadow-zone" of the aspiration catheter that were inaccessible for removal.



View larger version (69K):
[in this window]
[in a new window]
 
Figure 2. A, Angiogram shows GuardWire balloon (GW) occluding the distal internal carotid artery (ICA). Flow through the external carotid artery (ECA) is preserved. B, Cerebral angiogram in the lateral projection showing retrograde filling of the intracranial segment of the ICA and the middle cerebral artery (MCA) by collateral circulation from the ECA. The GuardWire balloon is visible. OA indicates ophthalmic artery.

Although the evidence that MES represent microemboli is well established, their use as a surrogate marker of embolic events during CAS may have a potential limitation.7,8 Although high MES counts correlate with an increased risk for embolic stroke in many clinical conditions, such a correlation during CAS has yet to be established. Because of the small number of clinical events, this correlation could not be examined in the present series. In addition, due to the logistics of enrolling consecutive patients into CAFE-USA when the technique became available at our institution, a randomized design of this study was not possible. However, the two groups were well matched in their clinical and angiographic characteristics. Subgroup analysis of the control group suggests that the difference in the stent type between the two groups did not seem to impact MES counts. Nevertheless, these data provide an important insight into the embolization profile during CAS and into the performance of the distal-balloon protection.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*References
 

  1. Roubin GS, New G, Iyer SS, et al. Immediate and late clinical outcomes of carotid artery stenting in symptomatic and asymptomatic carotid stenosis: a 5-year prospective analysis. Circulation. 2001; 103: 532–537.[Abstract/Free Full Text]
  2. Wholey MH, Wholey M, Mathias K, et al. Global experience in cervical carotid artery stent placement. Cathet Cardiovasc Interv. 2000; 50: 160–167.[Medline] [Order article via Infotrieve]
  3. Shawl F, Kadro W, Domanski MJ, et al. Safety and efficacy of elective carotid artery stenting in high-risk patients. J Am Coll Cardiol. 2000; 35: 1721–1728.[Abstract/Free Full Text]
  4. Hobson R. CREST (Carotid Revascularization Endarterectomy versus Stent Trial): background, design and current status. Semin Vasc Surg. 2000; 13: 139–143.[Medline] [Order article via Infotrieve]
  5. Ohki T, Veith F. Carotid stenting with and without protection devices: should protection be used in all patients?. Semin Vasc Surg. 2000; 13: 144–152.[Medline] [Order article via Infotrieve]
  6. Henry M, Amor M, Knonaris C, et al. Angioplasty and stenting of extracranial carotid arteries. Tex Heart Inst J. 2000; 27: 150–158.[Medline] [Order article via Infotrieve]
  7. Markus HS, Clifton A, Buckenham T, et al. Carotid angioplasty: detection of embolic signals during and after the procedure. Stroke. 1994; 25: 2403–2406.[Abstract]
  8. Markus HS. Monitoring embolism in real time. Circulation. 2000; 102: 826–828.[Free Full Text]
  9. Ackerstaff RG, Moons KG, Van de Vlasakker CJ, et al. Association of intraoperative transcranial Doppler monitoring variables with stroke from carotid endarterectomy. Stroke. 2000; 31: 1817–1823.[Abstract/Free Full Text]
  10. Gaunt ME, Martin PJ, Smith JL, et al. Clinical relevance of intraoperative embolization detected by transcranial Doppler ultrasonography during carotid endarterectomy: a prospective study of 100 patients. Br J Surg. 1994; 81: 1435–1439.[Medline] [Order article via Infotrieve]
  11. North American Symptomatic Carotid Endarterectomy Trial. Methods, patient characteristics, and progress. Stroke. 1991; 22: 711–720.[Abstract/Free Full Text]
  12. Al-Mubarak N, Roubin GS, Iyer SS, et al. Techniques of carotid stenting: The state of the art. Semin Vasc Surg. 2000; 13: 117–129.[Medline] [Order article via Infotrieve]
  13. Ringelstein EB, Droste DW, Babikian VL, et al. Consensus of microembolus detection by TCD: international consensus group on microembolus detection. Stroke. 1998; 29: 725–729.[Abstract/Free Full Text]
  14. Markus HS, Loh A, Isreal D, et al. Microscopic air embolism during cerebral angiography and strategies for its avoidance. Lancet. 1993; 341: 784–787.[Medline] [Order article via Infotrieve]
  15. Al-Mubarak N, Roubin GS, Vitek JJ, et al. Subarrachnoidal hemorrhage following carotid stenting with the distal-balloon protection: a case report. Cathet Cardiovasc Interv. In press.



This article has been cited by other articles:


Home page
J. Neurol. Neurosurg. PsychiatryHome page
Y Iguchi, K Kimura, K Kobayashi, Y Ueno, K Shibazaki, and T Inoue
Microembolic signals at 48 hours after stroke onset contribute to new ischaemia within a week
J. Neurol. Neurosurg. Psychiatry, March 1, 2008; 79(3): 253 - 259.
[Abstract] [Full Text] [PDF]


Home page
PERSPECT VASC SURG ENDOVASC THERHome page
M. K. Eskandari
Preventable Complications of Carotid Stenting
Perspectives in Vascular Surgery and Endovascular Therapy, March 1, 2008; 20(1): 17 - 25.
[Abstract] [PDF]


Home page
J Am Coll CardiolHome page
E. Mahmud, J. J. Cavendish, and A. Salami
Current Treatment of Peripheral Arterial Disease: Role of Percutaneous Interventional Therapies
J. Am. Coll. Cardiol., August 7, 2007; 50(6): 473 - 490.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M. Maynar, S. Baldi, R. Rostagno, T. Zander, M. Rabellino, R. Llorens, J. Alvarez, and F. Barajas
Carotid Stenting without Use of Balloon Angioplasty and Distal Protection Devices: Preliminary Experience in 100 Cases
AJNR Am. J. Neuroradiol., August 1, 2007; 28(7): 1378 - 1383.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. J. Clark, S. Lessio, M. O'Donoghue, C. Tsalamandris, R. Schainfeld, and K. Rosenfield
Mechanisms and Predictors of Carotid Artery Stent Restenosis: A Serial Intravascular Ultrasound Study
J. Am. Coll. Cardiol., June 20, 2006; 47(12): 2390 - 2396.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
G. S. Roubin, S. Iyer, A. Halkin, J. Vitek, and C. Brennan
Realizing the Potential of Carotid Artery Stenting: Proposed Paradigms for Patient Selection and Procedural Technique
Circulation, April 25, 2006; 113(16): 2021 - 2030.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
C. J. White
Catheter-Based Therapy for Atherosclerotic Renal Artery Stenosis
Circulation, March 21, 2006; 113(11): 1464 - 1473.
[Full Text] [PDF]


Home page
VASC ENDOVASCULAR SURGHome page
J. C. Lin, R. R. Kolvenbach, and L. Pinter
Protected Carotid Artery Stenting and Angioplasty via Transfemoral versus Transcervical Approaches
Vascular and Endovascular Surgery, November 1, 2005; 39(6): 499 - 503.
[Abstract] [PDF]


Home page
J Am Coll CardiolHome page
D. A. Gorog, R. A. Foale, and I. Malik
Distal Myocardial Protection During Percutaneous Coronary Intervention: When and Where?
J. Am. Coll. Cardiol., October 18, 2005; 46(8): 1434 - 1445.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. I. Bluth, J. A. Vos, and R. G. A. Ackerstaff
Value of US in Selecting Patients for Carotid Angioplasty and Stent Placement * Drs Vos and Ackerstaff respond:
Radiology, October 1, 2005; 237(1): 374 - 375.
[Full Text] [PDF]


Home page
StrokeHome page
H. D. Aronow, M. Shishehbor, D. A. Davis, I. L. Katzan, D. L. Bhatt, C. T. Bajzer, A. Abou-Chebl, K. W. Derk, P. L. Whitlow, and J. S. Yadav
Leukocyte Count Predicts Microembolic Doppler Signals During Carotid Stenting: A Link Between Inflammation and Embolization
Stroke, September 1, 2005; 36(9): 1910 - 1914.
[Abstract] [Full Text] [PDF]


Home page
Arch NeurolHome page
G. Orlandi, S. Fanucchi, S. Gallerini, C. Sonnoli, M. Cosottini, M. Puglioli, F. Sartucci, and L. Murri
Impaired Clearance of Microemboli and Cerebrovascular Symptoms During Carotid Stenting Procedures
Arch Neurol, August 1, 2005; 62(8): 1208 - 1211.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
S. P. Lownie, D. M. Pelz, D. H. Lee, S. Men, I. Gulka, and P. Kalapos
Efficacy of Treatment of Severe Carotid Bifurcation Stenosis By Using Self-Expanding Stents without Deliberate Use of Angioplasty Balloons
AJNR Am. J. Neuroradiol., May 1, 2005; 26(5): 1241 - 1248.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
G. Orlandi, S. Gallerini, M. Cosottini, L. Murri, L. K. Sztriha, E. Voros, P. Szikra, and L. Vecsei
Postprocedural Emboli in Carotid Artery Stenting: Where Do They Come From? * Response:
Stroke, May 1, 2005; 36(5): 928 - 929.
[Full Text] [PDF]


Home page
RadiologyHome page
J. A. Vos, J. C. van den Berg, S. M. P. G. Ernst, M. J. Suttorp, T. T. C. Overtoom, H. W. Mauser, O. J. M. Vogels, H. P. M. van Heesewijk, F. L. Moll, Y. van der Graaf, et al.
Carotid Angioplasty and Stent Placement: Comparison of Transcranial Doppler US Data and Clinical Outcome with and without Filtering Cerebral Protection Devices in 509 Patients
Radiology, February 1, 2005; 234(2): 493 - 499.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
L. K. Sztriha, E. Voros, K. Sas, R. Szentgyorgyi, A. Pocsik, P. Barzo, P. Szikra, A. Makai, A. Szolics, P. Elek, et al.
Favorable Early Outcome of Carotid Artery Stenting Without Protection Devices
Stroke, December 1, 2004; 35(12): 2862 - 2866.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. Schmidt, K.-W. Diederich, S. Scheinert, S. Braunlich, T. Olenburger, G. Biamino, G. Schuler, and D. Scheinert
Effect of two different neuroprotection systems on microembolization during carotid artery stenting
J. Am. Coll. Cardiol., November 16, 2004; 44(10): 1966 - 1969.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
R. Zahn, B. Mark, N. Niedermaier, U. Zeymer, P. Limbourg, T. Ischinger, K. Haerten, K. E. Hauptmann, E.-R. v. Leitner, W. Kasper, et al.
Embolic protection devices for carotid artery stenting: better results than stenting without protection?
Eur. Heart J., September 1, 2004; 25(17): 1550 - 1558.
[Abstract] [Full Text]


Home page
PERSPECT VASC SURG ENDOVASC THERHome page
H. E. Rodriguez and L. Leon
Current Status of Carotid Angioplasty and Stenting
Perspectives in Vascular Surgery and Endovascular Therapy, June 1, 2004; 16(2): 111 - 119.
[Abstract] [PDF]


Home page
NEJMHome page
D. P. Slovut and J. W. Olin
Fibromuscular Dysplasia
N. Engl. J. Med., April 29, 2004; 350(18): 1862 - 1871.
[Full Text] [PDF]


Home page
CirculationHome page
J. J. Ferguson
If There's Smoke, Is There Fire?
Circulation, March 30, 2004; 109(12): 1442 - 1444.
[Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
J. D. Barr, J. J. Connors III, D. Sacks, J. C. Wojak, G. J. Becker, J. F. Cardella, B. Chopko, J. E. Dion, A. J. Fox, R. T. Higashida, et al.
Quality Improvement Guidelines for the Performance of Cervical Carotid Angioplasty and Stent Placement: Developed by a Collaborative Panel of the American Society of Interventional and Therapeutic Neuroradiology, the American Society of Neuroradiology, and the Society of Interventional Radiology
AJNR Am. J. Neuroradiol., November 1, 2003; 24(10): 2020 - 2034.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. Schluter, T. Tubler, J. C. Steffens, D. G. Mathey, and J. Schofer
Focal ischemia of the brain after neuroprotected carotid artery stenting
J. Am. Coll. Cardiol., September 17, 2003; 42(6): 1007 - 1013.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. S. Yadav
Protecting the brain:how do we measure success?
J. Am. Coll. Cardiol., September 17, 2003; 42(6): 1014 - 1016.
[Full Text] [PDF]


Home page
CirculationHome page
G. W. Stone, C. Rogers, J. Hermiller, R. Feldman, P. Hall, R. Haber, A. Masud, P. Cambier, R. P. Caputo, M. Turco, et al.
Randomized Comparison of Distal Protection With a Filter-Based Catheter and a Balloon Occlusion and Aspiration System During Percutaneous Intervention of Diseased Saphenous Vein Aorto-Coronary Bypass Grafts
Circulation, August 5, 2003; 108(5): 548 - 553.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
F. Liistro and C. Di Mario
Carotid artery stenting
Heart, August 1, 2003; 89(8): 944 - 948.
[Full Text] [PDF]


Home page
StrokeHome page
B. Eckert and H. Zeumer
Editorial Comment--Carotid Artery Stenting With or Without Protection Devices? Strong Opinions, Poor Evidence!
Stroke, August 1, 2003; 34(8): 1941 - 1943.
[Full Text] [PDF]


Home page
StrokeHome page
A. Kastrup, K. Groschel, H. Krapf, B. R. Brehm, J. Dichgans, and J. B. Schulz
Early Outcome of Carotid Angioplasty and Stenting With and Without Cerebral Protection Devices: A Systematic Review of the Literature
Stroke, March 1, 2003; 34(3): 813 - 819.
[Abstract] [Full Text] [PDF]


Home page
Vasc MedHome page
S. Macdonald and P. A Gaines
Current concepts of mechanical cerebral protection during precutaneous carotid intervention
Vascular Medicine, February 1, 2003; 8(1): 25 - 32.
[Abstract] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Al-Mubarak, N.
Right arrow Articles by Leon, M. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Al-Mubarak, N.
Right arrow Articles by Leon, M. B.
Related Collections
Right arrow Carotid Stenosis
Right arrow Embolic stroke
Right arrow Doppler ultrasound, Transcranial Doppler etc.
Right arrow Pathology of Stroke
Right arrow Angioplasty and Stenting