(Circulation. 2001;104:2236.)
© 2001 American Heart Association, Inc.
Basic Science Reports |
From the Department of Cardiology, Thoraxcenter (W.J.v.d.G., E.R., M.S.H., R.B., J.L., P.W.S., A.d.B., P.D.V., E.B., H.M.M.v.B.), and Department of Radiation Oncology, Erasmus Medical Center (V.L.M.A.C., P.C.L.), Rotterdam, the Netherlands; and Guidant Inc, Santa Clara, Calif (A.A., T.H.).
Correspondence to Willem J. van der Giessen, MD, PhD, Department of Cardiology, Thoraxcenter, Bd 412, Erasmus Medical Center Rotterdam, 3015 GD Rotterdam, the Netherlands. E-mail vandergiessen{at}card.azr.nl
| Abstract |
|---|
|
|
|---|
Methods and Results Half-radioactive stents (n=20) and nonradioactive control stents (n=10) were implanted in the coronary arteries of Yucatan micropigs. Animals received aspirin and clopidogrel as antithrombotics. After 4 weeks, a significant midstent stenosis was observed by angiography in the half-radioactive stents. Two animals died suddenly because of coronary occlusion at this mid zone at 8 and 10 weeks. At 12-week follow-up angiography, intravascular ultrasound and histomorphometry showed a significant neointimal thickening at the midstent dose-falloff zone of the half-radioactive stents, but not at the stent-to-artery transitions at both extremities. Such a midstent response (mean angiographic late loss 1.0 mm) was not observed in the nonradioactive stents (mean loss 0.4 to 0.6 mm; P< 0.01).
Conclusions The edge effect of high-dose radioactive stents in porcine coronary arteries is associated with the combination of stent injury and radioactive dose falloff.
Key Words: stents radioisotopes angioplasty restenosis
| Introduction |
|---|
|
|
|---|
| Methods |
|---|
|
|
|---|
Half-Radioactive Multi-Link Stent
Regular 18-mm-long Multi-Link Duet stents (Guidant) were made radioactive with 32P (ß-emitter, half-life 14 days) over half of their length in the Forschungszentrum Karlsruhe GmbH, Germany. This yielded 1 radioactive half of 0.9 µCi/mm stent length (range 7.2 to 9.0 µCi/9 mm) and 1 nonradioactive half (Figure 1). Stents were crimped onto dedicated balloons (3.0 mm in diameter) designed with so-called short transitional edge protection (STEP) technology to limit balloon-induced damage outside the stented segment (Figure 2). Half-radioactive stents with the radioactive part directed distally or proximally on the balloons, as well as nonradioactive control stents, were provided sterile, covered by a polymeric shielding, and encoded to allow for random implantation.
|
|
Stent Implantation and Quantitative Coronary Angiography
A segment with a diameter of 2.7 to 3.0 mm was selected in each coronary artery by use of quantitative coronary angiography (QCA) (CAAS II, PIE Medical). Thereafter, 2 half-radioactive stents (1 hot-distal and 1 hot-proximal) and 1 control stent per animal were randomly implanted in different vessels at 8 atm balloon inflation pressure, aiming at a balloon-to-artery ratio of 1.1:1. After repeat angiography of the stented coronary arteries, the catheter and introducer sheath were removed, and the arteriotomy and the skin were closed. Animals received 300 mg aspirin and 75 mg clopidogrel daily during follow-up. After 4 and 12 weeks, QCA was repeated in the same projection.
3D Intracoronary Ultrasound Analysis
Intravascular ultrasound (IVUS) image acquisition was performed at 12-week follow-up with a 30-MHz mechanical system (ClearView, CVIS, Boston Scientific Corp). Motorized catheter pullback was ECG-gated (peak of the R wave) to eliminate motion artifacts (EchoScan, Tomtec). 3D volumetric lumen volume and neointimal volume were assessed with a semiautomatic contour detection program.22 Data are given as volumes normalized to 1 mm stent length (mm3/mm) to allow for direct comparison of zones of different lengths.
Histomorphometry
The coronary arteries were pressure-fixed in situ and processed for microscopy as described.23 After
7 half-lives of 14 days, the embedded stents were cut into equal longitudinal halves after alignment under fluoroscopic control. Thereafter, the specimens were placed on radiochromic film for 48 hours to allow identification of the radioactive part and the individual radioactive struts (Figure 3).
|
The neointima on top of the individual stent struts was measured on en-bloc toluidine bluestained specimens with a microscopy image analysis system (Impak C, Clemex Technologies). The distance between the endothelial lining and the stent strut or internal elastic lamina was taken as the thickness of the intima.
After completion of morphometric analysis, transverse thin sections were cut for qualitative histological examination. Hematoxylin-eosin was used as routine stain, and resorcin-fuchsin was used as elastin stain.
Definition of Subsegments
The stented vessel was divided into subsegments that were defined as follows (the stent spanned a distance from 0 to 18 mm, Figure 1): Reference zone: proximal (-5 to -3 mm) or distal (21 to 23 mm) vessel segment adjacent to the stent and not affected by radiation or balloon injury. Hot transition zone: zone between radioactive half and reference zone (17 to 21 mm). Hot zone: radioactive stent segment with full dose (10 to 16 mm). Mid zone: zone connecting nonradioactive and radioactive stent half (7 to 10 mm). Cold zone: nonradioactive segment within the stent (2 to 6 mm). Cold transition zone: between nonradioactive half and reference zone (-3 to 1 mm).
Statistical Analysis
Data were expressed as mean±SD. Angiographic data were analyzed by 2-way repeated-measures ANOVA followed by post hoc Dunnetts test. Histological data were analyzed by 2-way ANOVA and Dunnetts test. For these parameters, a value of P<0.05 was considered statistically significant, because Dunnetts test corrects for repeated testing. IVUS data were analyzed by 2-way ANOVA and unpaired t test. Because of repeated comparisons, a value of P<0.01 was considered statistically significant. Sigmastat and SPSS statistical software were used.
| Results |
|---|
|
|
|---|
At 4 weeks, angiography showed a reduction in lumen at the mid zone in all half-radioactive stents, but not in control stents (Figure 4). Two animals were killed to examine this phenomenon. Between 4 and 12 weeks, 2 animals died suddenly. Postmortem examination showed a thrombotic occlusion at the narrowed mid zone of the half-radioactive stent in the LAD. Five surviving animals remained for angiographic, IVUS, and histological examination at 12 weeks.
|
Radioactivity of Stents After Explantation
Exposure of radiochromic film by the embedded stent specimen revealed the activity of the individual stent struts (Figure 3). Typically, per half-radioactive stent, 7 struts per longitudinal cross section were identified as hot, and the remaining 7 struts were identified as cold.
QCA Measurements
QCA showed similar lumen diameters of the arteries with half-radioactive or control stents at baseline (Table). Average balloon size was 2.8±0.1 mm, and balloon-to-artery ratio was 1.1±0.1. After stenting, the vessels measured 2.8±0.1 mm, and no differences between groups were observed.
|
At 4 weeks, both types of half-radioactive stents showed a significantly smaller lumen diameter of 1.9 mm in the mid zone versus 2.4 mm in the cold and hot parts of the same stents (P<0.05). The mean diameter of the control stents was 2.3±0.3 mm, and in the midstent zone, 2.1±0.4 mm (P=NS).
Control stents showed no change in lumen diameter between 4- and 12-week data (2.2±0.4 mm). In the half-radioactive stents, however, a significant further decline of diameter at the mid zone could be observed. For the "proximal-hot" and the "distal-hot" stents, mid-zone diameters were 1.5±0.3 mm and 1.5±0.9 mm, respectively (P<0.05 versus control).
3D IVUS
IVUS examination at 12 weeks showed no difference in neointimal volume of the control stent (3.2±3.5 mm3/mm stent), cold zones (4.5±3.9 mm3/mm), and hot zones (2.0±1.3 mm3/mm). At the mid zones of the half-radioactive stents, however, a significant increase in neointimal volume was observed (6.0±3.5 mm3/mm; P<0.01).
Histopathological Examination
Macroscopy
The half-radioactive stents, but not the control stents, explanted after 4 and 12 weeks all demonstrated narrowing at the mid zone (Figure 5). Specimens retrieved from animals that died suddenly showed thrombotic occlusion at narrowed mid zones of LAD stents.
|
Microscopy
Both control stents and cold zones of the half-radioactive stents showed the typical appearance of a stented normal artery: mild to moderate intimal thickening consisting of smooth muscle cells (SMCs) in extracellular matrix with sparse inflammatory cells and covered by continuous endothelium (Figure 6A).
|
The mid zone of the half-radioactive stents was characterized by tissue appearing in a specific order (Figure 6B). From cold to hot: (1) enlarged cells with nuclear atypia (as previously described in association with radiotherapy24); (2) a steep increase in neointima containing SMCs in disarray within abundant extracellular matrix, dispersed macrophage foam cells, and amorphous proteinaceous material (edema) infiltrated by leukocytes. Endothelialization and neointimal cellularity decreased in parallel toward the hot zone; and (3) a sharp decrease in intimal thickness with a concomitant change to immature granulation tissue after reaching the first hot stent strut.
The hot zone generally showed immature granulation tissue of variable thickness containing amorphous proteinaceous material with few endothelial cells and a diffuse inflammatory response (Figure 6C). The intima-media border zone contained areas with barely organized thrombotic material (especially overlying stent struts).
The hot transition zone showed asymmetrical intimal thickening with incomplete endothelialization and characteristic pathological features: barely organized thrombotic material overlying the stent struts and the intima-media border zone, foam cells in the intima-media border zone, proteinaceous material infiltrated by leukocytes that composed the body of the intima, arborizing SMCs within an abundant extracellular matrix that composed the body of the intima and luminal border zone, and hypertrophic cells with nuclear atypia scattered throughout the intima and media. Normal vascular architecture returned in both control and half-radioactive stents within 2 mm from the stent edges.
Morphometry
Comparison of the mean neointimal thickness over the struts in the cold zone (struts 2 to 5) and the hot zone (struts 10 to 13) with the mid zone struts (struts 7 and 8) showed a significantly larger amount of neointima in the mid zone (P< 0.05; Figure 7). Also, the difference between the maximal neointimal thickness of the half-radioactive mid zones (0.65±0.06 mm) and the control stent mid zones (0.40±0.08 mm) was significant (P<0.05).
|
| Discussion |
|---|
|
|
|---|
Main Findings
In the present study, a moderate reduction of lumen diameter in the control, nonradioactive stents was observed, which was evenly distributed over the length of the stent. In contrast, the half-radioactive stents showed a maximal reduction of lumen diameter at the mid zone. This increased tissue response at the midstent zone exceeded that at the stent edges and demonstrated distinct histopathological features, such as an increased amount of extracellular material and thrombus, features recently described in a human case report.13
Effect of Injury and Low-Dose Radiation on Neointimal Hyperplasia
The mid-zone hyperplasia coincided with the presence of the stent and a sharply decreasing radioactive dose level. Each of these can promote cellular proliferation. The stent does so by inflicting chronic injury, causing inflammation and tissue proliferation.27,28 Low-dose radiation (±2 Gy) has been shown to potentiate cellular metabolic activities29 and immunological responses in various cells of mesodermal origin.3033 Furthermore, experimental studies of endovascular brachytherapy have shown that relatively low doses (±10 Gy) caused a paradoxical increase in tissue response,14,15 whereas higher doses proved antiproliferative. In a model of concanavalin-induced proliferation, low-dose radiation enhanced the tissue response.30 Combining the chronic mechanical irritation by the stent with low-dose radiation also had an additive effect on tissue proliferation in the present study. These findings suggest that low-dose radiation catalyzes the tissue response to pro-proliferative factors. To the best of our knowledge, low-dose radiation alone was never able to induce such a degree of tissue proliferation in normal tissue. The fact that significant neointima was not observed at the transition from hot stent half to artery underscores this.
Our results indicate that edge effects of radioactive stents may be avoided by limiting arterial trauma at the edges of the stent combined with measures to effectively irradiate the first 2 to 3 mm outside the stent extremities. The former could be done by using dedicated delivery systems or by manufacturing thinner and more flexible stent edges. The latter might be achieved by use of more penetrating radiation qualities, such as
-radiation.
Conclusions
This study demonstrates that the combination of radioactive dose falloff and the presence of stent material in the artery wall may be responsible for the edge restenosis that limits the efficacy of radioactive stents in the clinical setting. Further studies on the relationship between radiation dose and tissue response may enhance our understanding of the balance between tissue radiosensitivity, arterial injury, and effective radiation dose.
| Acknowledgments |
|---|
Received June 4, 2001; revision received August 2, 2001; accepted August 3, 2001.
| References |
|---|
|
|
|---|
2.
Fischman DL, Leon MB, Baim DS, et al. A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators. N Engl J Med. 1994; 331: 496501.
3. Popowski Y, Verin V, Urban P. Endovascular beta-irradiation after percutaneous transluminal coronary balloon angioplasty. Int J Radiat Oncol Biol Phys. 1996; 36: 841845.[Medline] [Order article via Infotrieve]
4.
Condado JA, Waksman R, Gurdiel O, et al. Long-term angiographic and clinical outcome after percutaneous transluminal coronary angioplasty and intracoronary radiation therapy in humans. Circulation. 1997; 96: 727732.
5.
Teirstein PS, Massullo V, Jani S, et al. Catheter-based radiotherapy to inhibit restenosis after coronary stenting. N Engl J Med. 1997; 336: 16971703.
6.
Hehrlein C, Stintz M, Kinscherf R, et al. Pure ß-particleemitting stents inhibit neointima formation in rabbits. Circulation. 1996; 93: 641645.
7.
Carter AJ, Laird JR, Bailey LR, et al. Effects of endovascular radiation from a ß-particleemitting stent in a porcine coronary restenosis model: a dose-response study. Circulation. 1996; 94: 23642368.
8. Fischell TA, Carter AJ, Laird JR. The beta-particle-emitting radioisotope stent (Isostent): animal studies and planned clinical trials. Am J Cardiol. 1996; 78: 4550.[Medline] [Order article via Infotrieve]
9.
Wardeh AJ, Kay IP, Sabate M, et al. ß-Particleemitting radioactive stent implantation: a safety and feasibility study. Circulation. 1999; 100: 16841689.
10.
Albiero R, Adamian M, Kobayashi N, et al. Short- and intermediate-term results of 32P radioactive ß-emitting stent implantation in patients with coronary artery disease: the Milan Dose-Response Study. Circulation. 2000; 101: 1826.
11.
Albiero R, Nishida T, Adamian M, et al. Edge restenosis after implantation of high activity 32P radioactive ß-emitting stents. Circulation. 2000; 101: 24542457.
12.
Wardeh AJ, Knook AHM, Kay IP, et al. Clinical and angiographic follow-up after implantation of a 612 microCi radioactive stent in patients with coronary artery disease. Eur Heart J. 2001; 22: 669675.
13.
Kim H, Waksman R, Kollum M, et al. Edge stenosis after intracoronary radiotherapy: angiographic, intravascular, and histological findings. Circulation. 2001; 103: 22192220.
14. Virmani R, Farb A, Carter AJ, et al. Comparative pathology: radiation-induced coronary artery disease in man and animals. Semin Intervent Cardiol. 1998; 3: 163172.[Medline] [Order article via Infotrieve]
15. Weinberger J, Amols H, Ennis RD, et al. Intracoronary irradiation: dose response for the prevention of restenosis in swine. Int J Radiat Oncol Biol Phys. 1996; 36: 767775.[Medline] [Order article via Infotrieve]
16.
Hehrlein C, Gollan C, Donges K, et al. Low-dose radioactive endovascular stents prevent smooth muscle cell proliferation and neointimal hyperplasia in rabbits. Circulation. 1995; 92: 15701575.
17.
Carter AJ, Scott D, Bailey L, et al. Dose-response effects of 32P radioactive stents in an atherosclerotic porcine coronary model. Circulation. 1999; 100: 15481554.
18. van Beusekom HM, van der Giessen WJ, van Suylen R, et al. Histology after stenting of human saphenous vein bypass grafts: observations from surgically excised grafts 3 to 320 days after stent implantation. J Am Coll Cardiol. 1993; 21: 4554.[Abstract]
19. Edelman ER, Rogers C. Pathobiologic responses to stenting. Am J Cardiol. 1998; 81: 4E6E.[Medline] [Order article via Infotrieve]
20. Grewe PH, Thomas D, Machraoui A, et al. Coronary morphologic findings after stent implantation. Am J Cardiol. 2000; 85: 554558.[Medline] [Order article via Infotrieve]
21.
Sabate M, Costa MA, Kozuma K, et al. Geographic miss: a cause of treatment failure in radio-oncology applied to intracoronary radiation therapy. Circulation. 2000; 101: 24672471.
22.
von Birgelen C, Mintz GS, de Feyter PJ, et al. Reconstruction and quantification with three-dimensional intracoronary ultrasound: an update on techniques, challenges, and future directions. Eur Heart J. 1997; 18: 10561067.
23.
van Beusekom HM, Whelan DM, Hofma SH, et al. Long-term endothelial dysfunction is more pronounced after stenting than after balloon angioplasty in porcine coronary arteries. J Am Coll Cardiol. 1998; 32: 11091117.
24. Baker PM, Young RH. Radiation-induced pseudocarcinomatous proliferations of the urinary bladder: a report of 4 cases. Hum Pathol. 2000; 31: 678683.[Medline] [Order article via Infotrieve]
25.
Mudra H, Regar E, Klauss V, et al. Serial follow-up after optimized ultrasound-guided deployment of Palmaz- Schatz stents: in-stent neointimal proliferation without significant reference segment response. Circulation. 1997; 95: 363370.
26. Costa MA, Sabate M, Serrano P, et al. The effect of 32P beta-radiotherapy on both vessel remodeling and neointimal hyperplasia after coronary balloon angioplasty and stenting: a three-dimensional intravascular ultrasound investigation. J Invasive Cardiol. 2000; 12: 113120.[Medline] [Order article via Infotrieve]
27.
Hanke H, Strohschneider T, Oberhoff M, et al. Time course of smooth muscle cell proliferation in the intima and media of arteries following experimental angioplasty. Circ Res. 1990; 67: 651659.
28.
Hofma SH, Whelan DM, van Beusekom HM, et al. Increasing arterial wall injury after long-term implantation of two types of stent in a porcine coronary model. Eur Heart J. 1998; 19: 601609.
29. Eidus LK. Hypothesis regarding a membrane-associated mechanism of biological action due to low-dose ionizing radiation. Radiat Environ Biophys. 2000; 39: 189195.[Medline] [Order article via Infotrieve]
30. Kojima S, Matsumori S, Ishida H, et al. Possible role of elevation of glutathione in the acquisition of enhanced proliferation of mouse splenocytes exposed to small-dose gamma-rays. Int J Radiat Biol. 2000; 76: 16411647.[Medline] [Order article via Infotrieve]
31.
Chen SL, Cai L, Meng QY, et al. Low-dose whole-body irradiation (LD-WBI) changes protein expression of mouse thymocytes: effect of a LD-WBI-enhanced protein RIP10 on cell proliferation and spontaneous or radiation-induced thymocyte apoptosis. Toxicol Sci. 2000; 55: 97106.
32. Ibuki Y, Goto R. Contribution of inflammatory cytokine release to activation of resident peritoneal macrophages after in vivo low-dose gamma-irradiation. J Radiat Res (Tokyo). 1999; 40: 253262.[Medline] [Order article via Infotrieve]
33.
Wang GJ, Cai L. Induction of cell-proliferation hormesis and cell-survival adaptive response in mouse hematopoietic cells by whole-body low-dose radiation. Toxicol Sci. 2000; 53: 369376.
This article has been cited by other articles:
![]() |
W. J. van der Giessen, O. Sorop, P. W. Serruys, I. Peters-Krabbendam, and H. M.M. van Beusekom Lowering the Dose of Sirolimus, Released From a Nonpolymeric Hydroxyapatite Coated Coronary Stent, Reduces Signs of Delayed Healing J. Am. Coll. Cardiol. Intv., April 1, 2009; 2(4): 284 - 290. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Degertekin, P. A. Lemos, C. H. Lee, K. Tanabe, J.E. Sousa, A. Abizaid, E. Regar, G. Sianos, W. J. van der Giessen, P. J. de Feyter, et al. Intravascular ultrasound evaluation after sirolimus eluting stent implantation for de novo and in-stent restenosis lesions Eur. Heart J., January 1, 2004; 25(1): 32 - 38. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Cheneau, R. Waksman, H. Yazdi, R. Chan, J. Fourdnadjiev, C. Berzingi, V. Shah, A. E. Ajani, L. Leborgne, and F. O. Tio How to Fix the Edge Effect of Catheter-Based Radiation Therapy in Stented Arteries Circulation, October 22, 2002; 106(17): 2271 - 2277. [Abstract] [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2001 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |