(Circulation. 2002;105:2373.)
© 2002 American Heart Association, Inc.
Clinical Investigation and Reports |
From the Department of Cardiology, Swiss Cardiovascular Center, Bern, Switzerland.
Correspondence to Otto M. Hess, MD, Professor of Cardiology, Swiss Cardiovascular Center, Inselspital, CH-3010 Bern, Switzerland. E-mail otto.martin.hess{at}insel.ch
| Abstract |
|---|
|
|
|---|
Methods and Results Biplane quantitative coronary angiography was performed at rest and during bicycle exercise in 26 patients with coronary artery disease. Twelve patients had single vessel disease with stable angina pectoris (controls; group 1). Fourteen patients underwent coronary stenting for therapeutic reasons and were studied 10±3 months after the intervention (group 2). Minimal luminal area, stent area, and proximal and distal vessel areas were determined. In controls (group 1), vasoconstriction of the stenotic artery (- 29±4%; P<0.001) was observed during exercise, whereas the normal segment showed vasodilation (15±4%; P<0.05). In group 2, vasomotion of the stented segment was eliminated (0±1%), whereas the proximal and distal segments showed exercise-induced vasodilation (8±2% and 11±3%, respectively; P<0.005), which was not different from control segments (10±2%). Sublingual nitroglycerin was associated with maximal vasodilation of the proximal and distal vessel segments (30±8% and 38±13%, respectively; P<0.005).
Conclusions In contrast to the vasoconstriction of vessels in control patients, normal vasodilation of proximal and distal segments occurred during the physiological stress of exercise in patients with coronary stent placement. As expected, vasomotion was abolished in the stented region.
Key Words: stents exercise vasodilation vasoconstriction stenosis
| Introduction |
|---|
|
|
|---|
Enhanced endothelial dysfunction distal to the implanted stent has been reported by Caramori et al4 using acetylcholine testing late after the intervention. In contrast, partial normalization of coronary vasomotion of the treated vessel segment was found late after conventional balloon angiogplasty.5 Stenting mechanically stabilizes the dilated segment, which might convert a formerly dynamic artery into a rigid tube. Furthermore, the implantation of a metallic prosthesis induces considerable injury to the arterial wall, with prolonged inflammatory, prothrombotic, and proliferative reactions6,7 that are likely to extend beyond the stented segment. The purpose of the present study was, therefore, to evaluate coronary vasomotor response of the proximal and distal vessel segment several months after stenting using bicycle exercise as a physiological stress test.
| Methods |
|---|
|
|
|---|
Mean age and distribution of cardiovascular risk factors were similar in the 2 groups, as were the number of diseased vessels (Table 1). Balloon angioplasty and stent implantation were performed according to standard techniques. About half of the stents were premounted (AVE Microstent and Johnson & Johnson Crossflex stent) and half were hand-mounted stents (Johnson & Johnson, Palmaz Schatz, and Crown stents). Nominal stent diameter at implantation was 3.5 mm (n=7) and 3.0 mm (n=7) for premounted and hand-mounted stents, respectively, and mean stent length was 15±4 mm. Stents were deployed at an average pressure of 11±1 bar. Target vessels were the left anterior descending (n=7), left circumflex (n=2), and right coronary arteries (n=5). Residual stenosis after stent implantation was <10% in all patients.
|
Inclusion criteria for group 2 were successful stent implantation without angiographic restenosis, no additional hemodynamically significant stenosis, and willingness to participate in the study protocol with bicycle exercise. Exclusion criteria were unstable angina, recent myocardial infarction, coronary revascularization after stent placement, history of coronary spasm, severe left ventricular dysfunction, and clinically significant extracardiac disease.
Study Protocol
The local ethics committee approved the protocol, and informed consent was obtained from all patients. Vasoactive medication was discontinued 24 hours before catheterization. Only short-acting nitrates were allowed for angina relief, if necessary. Diagnostic catheterization was performed with standard techniques using 5F Judkins coronary catheters (Cordis). At the end of diagnostic catheterization, biplane coronary angiography was performed at rest with the patients feet attached to the supine bicycle ergometer. Exercise was begun at 50 or 75 W, and workload was increased every 2 minutes in increments of 25 W. The catheter was left in place during exercise. Coronary angiography was performed at the end of the maximal exercise level in deep inspiration. Average workload was slightly higher in the control group with stable angina pectoris (81±34 W) than in group 2 (63±13 W; P<0.05). This difference was attributable to several factors, such as smaller body size, higher age, and more exercise-limiting symptoms such as fatigue and leg weakness in group 2. The exercise test was terminated because of fatigue, angina pectoris, or ST-segment depression >0.2 mV. At the end of the exercise test, all patients received 1.6 mg of nitroglycerin sublingually and, 5 minutes later, coronary angiography was repeated. Nitroglycerin was administered routinely to assess endothelium-independent vasodilation. There were no complications related to the study protocol.
Quantitative Coronary Angiography
Coronary angiography was performed on a digital x-ray system (Philips DCI-SX and Philips Integris) at 12.5 frames/s. Simultaneous biplane projections were acquired in all patients, and rotation and angulation were adapted to minimize foreshortening of the target vessel.
Quantitative evaluation (Figure 1) was carried out in monoplane projection. Two orthogonal views were averaged for biplane assessment. Because of vessel overlap, analysis had to be restricted to a single plane in 50% of group 1 and 43% of group 2 segments, respectively. Data analysis was performed with the ACA package on Philips DCI/Integris systems with a documented accuracy of < 0.01 mm, precision of <0.10 mm,8 intraobserver variability of 0.11 mm, and interobserver variability of 0.10 mm.9 The tip of the diagnostic catheter (5F) was used for calibration purposes. At our center, intraobserver variability was
0.15 mm for minimal luminal diameter and
7% for stenosis severity.10 The measurements were taken by an independent observer who was blinded to the protocol. The diameter of defined vessel segments was determined at baseline and at the various steps of the protocol. Care was taken to select reference vessel segments between 2 branching points and not to include side branches. The same segments, identified by the anatomical landmarks, were assessed at all steps of the protocol. Mean cross-sectional lumen area was calculated from the 2 projections using an elliptical model. For monoplane projections, a circular shape was assumed. To optimize accuracy of the measurements, 3 measurements for each vessel segment were carried out and averaged. Percent changes were calculated in all patients using the baseline angiogram as reference.
|
In the control group, a vessel segment of a normal coronary artery, as well as the stenotic segment, were evaluated. In group 2, a normal vessel segment not related to the stented lesion, as well as the stented segment and its adjacent segments (between 5 and 15 mm proximal and distal to the stent edges) were assessed (Figure 1).
Statistics
Patient data are given as mean±1SD and cross-sectional lumen area measurements as mean±1SEM. Statistical analysis was performed by ANOVA for repeated measurements. When the test was significant, post hoc (Student-Newman-Keuls) tests for paired comparisons were applied. For intergroup comparisons, an unpaired Students t test was used. P<0.05 was considered significant.
| Results |
|---|
|
|
|---|
Hemodynamic Data
Heart rate, left ventricular end-diastolic pressure, left ventricular ejection fraction, and mean aortic pressure were similar in the 2 groups (Table 2). During exercise, heart rate increased in both groups significantly, as did mean aortic pressure. Exercise workload was significantly lower in group 2, and the rate-pressure-product tended to be smaller, although this difference did not reach statistical significance.
|
Quantitative Coronary Angiography
In the control group, the percent diameter stenosis of the stenotic vessel segment was 59±4%. This segment showed exercise-induced vasoconstriction (-29±4%), whereas the control segment elicited vasodilation of 15±4% (P
0.005 versus rest; Figure 2). Sublingual nitroglycerin induced maximal vasodilation (34±6%; P<0.005) in normal segments and mild vasodilation in stenoses (10±8%; P=NS).
|
In group 2, 5 of the 14 patients showed mild in-stent restenosis (23±10%). Vasomotion was completely abolished in the stented segment during exercise and after nitroglycerin, but it was maintained in the proximal and distal segment adjacent to the stent (proximal, 8±2%; distal, 11±3%; P<0.005 versus rest; Figure 3). Exercise-induced vasodilation of the control vessel in group 2 amounted to 10±2% and was not significantly different from that in the control vessel of group 1 (15±4%). Sublingual nitroglycerin was associated with significant vasodilation of the proximal, distal, and control vessel segment (proximal, 30±8%; distal, 38±13%; and control, 49±7%).
|
In the subgroup of patients with mild restenosis (n=5), the behavior of the proximal and distal vessel segment during exercise was similar to the whole group (proximal, 9±3%; distal, 8±4% vasodilation).
| Discussion |
|---|
|
|
|---|
Coronary Vasomotion During Exercise
Coronary artery disease is associated with exercise-induced vasoconstriction at the site of the stenotic lesion; normal coronary arteries dilate.11 The paradoxical response of the stenotic arteries during exercise has been attributed to (1) reduced nitric oxide bioavailability at the site of the stenosis (endothelial dysfunction); (2) enhanced vasoconstrictor response due to an increase in circulating catecholamines (enhanced sympathetic stimulation); (3) enhanced platelet aggregation due to turbulent blood flow through the stenotic lesion with release of thromboxane A2 and serotonin; and (4) flow-induced (passive) collapse of the normal vessel segment within the stenosis (Venturi effect).
These mechanisms alone or in combination may be responsible for exercise-induced vasoconstriction of stenotic lesions, and they may aggravate myocardial ischemia by a reduced flow increase during exercise, whereas normal vessel segments dilate as a result of the exercise-induced nitric oxide release.5,11 These mechanisms are stenosis related and do not necessarily apply to the proximal and distal vessel segments. However, a drop in distal perfusion pressure beyond a paradoxically constricting lesion, rather than diffuse endothelial dysfunction alone, might contribute to reduced distal vasomotor response.
A diminished vasomotor response to exercise has also been reported in patients with hypercholesterolemia or hypertension1214; this was thought to be due to endothelial dysfunction. Endothelial dysfunction has been assessed by intracoronary acetylcholine infusion showing vasodilation in normal coronary vessels but vasoconstriction in diseased arteries.1517 In the present study, the normal, although slightly reduced, vasodilation of the vessel segments adjacent to the stent during exercise (proximal, 8±2%; distal, 11±3%) can be explained by the presence of an increased serum cholesterol level (Table 1). Nevertheless, maximal vasodilation after nitroglycerin indicated preserved vasodilatory capacity. Mechanical stabilization of the treated vessel segment by coronary stenting abolishes vasoreactivity, but the loss is limited to the length of the implanted stent and does not extend to the adjacent vessel segments, as suggested by Caramori et al.4 The difference between the 2 studies may be related to the different techniques for measuring coronary vasomotor response (ie, pharmacological assessment of endothelial function by acetylcholine infusion versus flow-mediated [physiological] changes induced by bicycle exercise), although one earlier comparative study has shown a similar response in diseased coronary arteries during acetylcholine infusion and physiological exercise.18
Because testing endothelial function in human coronary arteries is a technically difficult procedure both with intracoronary acetylcholine infusion or supine bicycle exercise, almost no comparative data exist in the literature. However, even in the study of Gordon et al,18 the comparison between the 2 methods is limited to 6 patients. In 5 of these 6 patients, all vessel segments showed the same directional response to acetylcholine and exercise: 3 irregular and 2 stenotic segments constricted, whereas 4 smooth segments dilated to both acetylcholine and exercise. In accordance with our previously published data, 5,1114 Gordon et al18 showed vasoconstriction of stenotic and vasodilation of normal vessel segments in response to exercise. The order of magnitude of normal vessel vasodilation was similar to that in the present study (14.0±1.8%). Caramori et al4 reported vasoconstriction in the vessel segments distal to the stent and, to a lesser degree, after balloon angioplasty and even in normal control vessels. This is in contrast to our long-term data after balloon angioplasty.5 In line with the results of Gordon and coworkers,18 the discrepancy between the 2 studies could be explained by a more diffuse morphological disease in the cohort of Caramori et al.4 The response of angiographically normal vessel segments to intracoronary acetylcholine has been shown to be dependent not only on structural changes, but also on cardiovascular risk factors such as hypercholesterolemia or hypertension.16 Thus, a varying degree of coronary artery disease might provide an explanation for the differences.
Clinical Implications
Healing an injured vessel segment after percutaneous transluminal coronary angiography is associated with re-endothelialization19 and improvement of endothelial function.5 Although the cells of the neoendothelium are smaller and have a different shape compared with normal cells, the mechanical stabilization prevents vasodilation and, thus, may indirectly reduce nitric oxide bioavailability and diminish flow-mediated vascular changes. Therefore, the interruption of the continuity of the endothelial layering may lead to a propagation of arteriosclerosis distal to the stented vessel and impair the long-term outcome of coronary interventions. However, the present study indicates that the vasomotor response to exercise is maintained at the proximal and distal vessel sites and, thus, seems not to jeopardize the long-term results of coronary artery stenting.
It is of interest that even in those patients who developed some degree of in-stent restenosis (n=5), proximal and distal vasomotion was preserved. Apparently, mild in-stent restenosis does not affect the vasomotor response of the distal vessel segment.
Study Limitations
The following limitations may have influenced the data of the current study. (1) The differences in workload between the 2 groups may be explained by differences in body size, age, and exercise-limiting symptoms. Despite the lower workload in group 2, the reaction to exercise was similar to that in group 1. (2) Cardiovascular risk factors were slightly different between the 2 study groups. However, these differences were not statistically significant, although the stent group showed more risk factors than the control group. Nevertheless, the stent group elicited a nearly normal reaction of the vessels adjacent to the stented segment, indicating that there is no diffuse endothelial dysfunction after stent placement.
Conclusions
Coronary artery stenoses show exercise-induced vasoconstriction, whereas normal arteries dilate. This paradoxical response of stenotic arteries has been attributed to endothelial dysfunction with reduced nitric oxide bioavailability, enhanced sympathetic stimulation during exercise, platelet activation due to turbulent blood flow, or a passive vessel collapse of the normal vessel segment within the stenosis. In the present study, we showed that stent placement abolishes paradoxical vasoconstriction of the coronary stenosis but does not adversely affect vasomotion of the adjacent vessel segments. Thus, paradoxical vasoconstriction is a local, stenosis-related problem and does not extend to the proximal and distal vessel segments during the physiological stress of exercise.
Received December 31, 2001; revision received March 11, 2002; accepted March 11, 2002.
| References |
|---|
|
|
|---|
2.
Kimura T, Yokoi H, Nakagawa Y, et al. Three-year follow-up after implantation of metallic coronary-artery stents. N Engl J Med. 1996; 334: 561566.
3. National Institute for Clinical Excellence. Guidance on coronary artery stents in the treatment of ischemic heart disease. Available at: www.nice.org.uk. Accessed 2000.
4.
Caramori PR, Lima VC, Seidelin PH, et al. Long-term endothelial dysfunction after coronary artery stenting. J Am Coll Cardiol. 1999; 34: 16751679.
5.
Suter TM, Buechi M, Hess OM, et al. Normalization of coronary vasomotion after percutaneous transluminal coronary angioplasty? Circulation. 1992; 85: 8692.
6.
Farb A, Sangiorgi G, Carter AJ, et al. Pathology of acute and chronic coronary stenting in humans. Circulation. 1999; 99: 4452.
7.
Hanke H, Kamenz J, Hassenstein S, et al. Prolonged proliferative response of smooth muscle cells after experimental intravascular stenting. Eur Heart J. 1995; 16: 785793.
8. Reiber JHC. An overview of coronary quantitation techniques as of 1989.In: Reiber JHC, Serruys PW, eds. Quantitative Coronary Arteriography. Dordrecht, the Netherlands: Kluwer Academic Publishers; 1991: 55132.
9. Reiber JHC, Von Land CD, Koning G, et al. Comparison of accuracy and precision of quantitative coronary arterial analysis between cinefilm and digital systems.In: Reiber JHC, Serruys PW, eds. Progress in Quantitative Coronary Arteriography. Dordrecht, the Netherlands: Kluwer Academic Publishers; 1994: 6785.
10.
Schnyder G, Roffi M, Pin R, et al. Decreased rate of coronary restenosis after lowering of plasma homocysteine levels. N Engl J Med. 2001; 345: 15931600.
11.
Gage JE, Hess OM, Murakami T, et al. Vasoconstriction of stenotic coronary arteries during dynamic exercise in patients with classic angina pectoris: reversibility by nitroglycerin. Circulation. 1986; 73: 865876.
12.
Seiler C, Hess OM, Buechi M, et al. Influence of serum cholesterol and other coronary risk factors on vasomotion of angiographically normal coronary arteries. Circulation. 1993; 88: 21392148.
13. Frielingsdorf J, Kaufmann P, Seiler C, et al. Abnormal coronary vasomotion in hypertension: role of coronary artery disease. J Am Coll Cardiol. 1996; 28: 935941.[Abstract]
14.
Frielingsdorf J, Kaufmann P, Suter T, et al. Percutaneous transluminal coronary angioplasty reverses vasoconstriction of stenotic coronary arteries in hypertensive patients. Circulation. 1998; 98: 11921197.
15. Ludmer PL, Selwyn AP, Shook TL, et al. Paradoxical vasoconstriction induced by acetylcholine in atherosclerotic coronary arteries. N Engl J Med. 1986; 315: 10461051.[Abstract]
16.
Vita JA, Treasure CB, Nabel EG, et al. Coronary vasomotor response to acetylcholine relates to risk factors for coronary artery disease. Circulation. 1990; 81: 491497.
17.
Zeiher AM, Drexler H, Wollschläger H, et al. Modulation of coronary vasomotor tone in humans. Progressive endothelial dysfunction with different early stages of coronary atherosclerosis. Circulation. 1991; 83: 391401.
18. Gordon JB, Ganz P, Nabel EG, et al. Atherosclerosis influences the vasomotor response of epicardial coronary arteries to exercise. J Clin Invest. 1989; 83: 19461952.
19.
Weidinger FF, McLenachan JM, Cybulsky MI, et al. Persistent dysfunction of regenerated endothelium after balloon angioplasty of rabbit iliac artery. Circulation. 1990; 81: 16671679.
This article has been cited by other articles:
![]() |
M. Hamilos, J. Sarma, M. Ostojic, T. Cuisset, G. Sarno, N. Melikian, A. Ntalianis, O. Muller, E. Barbato, B. Beleslin, et al. Interference of Drug-Eluting Stents With Endothelium-Dependent Coronary Vasomotion: Evidence for Device-Specific Responses Circ Cardiovasc Interv, December 1, 2008; 1(3): 193 - 200. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. I. Hamilos, M. Ostojic, B. Beleslin, D. Sagic, L. Mangovski, S. Stojkovic, M. Nedeljkovic, D. Orlic, B. Milosavljevic, D. Topic, et al. Differential effects of drug-eluting stents on local endothelium-dependent coronary vasomotion. J. Am. Coll. Cardiol., June 3, 2008; 51(22): 2123 - 2129. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Togni, S. Windecker, R. Cocchia, P. Wenaweser, S. Cook, M. Billinger, B. Meier, and O. M. Hess Sirolimus-Eluting Stents Associated With Paradoxic Coronary Vasoconstriction J. Am. Coll. Cardiol., July 19, 2005; 46(2): 231 - 236. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Serry and W. F. Penny Endothelial Dysfunction After Sirolimus-Eluting Stent Placement J. Am. Coll. Cardiol., July 19, 2005; 46(2): 237 - 238. [Full Text] [PDF] |
||||
![]() |
P. Wenaweser, C. Rey, F. R. Eberli, M. Togni, D. Tuller, S. Locher, A. Remondino, C. Seiler, O. M. Hess, B. Meier, et al. Stent thrombosis following bare-metal stent implantation: success of emergency percutaneous coronary intervention and predictors of adverse outcome Eur. Heart J., June 2, 2005; 26(12): 1180 - 1187. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Togni, S. Windecker, P. Wenaweser, D. Tueller, A. Kaisaier, W. Maier, B. Meier, and O. M. Hess Deleterious Effect of Coronary Brachytherapy on Vasomotor Response to Exercise Circulation, July 13, 2004; 110(2): 135 - 140. [Abstract] [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2002 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |