(Circulation. 2002;106:2859.)
© 2002 American Heart Association, Inc.
Special Review |
From the Division of Cardiology, Montreal General Hospital/McGill University (M.N.B.), and the Divisions of Cardiology and Clinical Epidemiology, Jewish General Hospital/McGill University (M.J.E.), Montreal, Quebec, Canada.
Correspondence to Mark J. Eisenberg, MD, MPH, Associate Professor of Medicine, Divisions of Cardiology and Clinical Epidemiology, Jewish General Hospital/McGill University, 3755 Cote-St-Catherine Rd, Suite A-118, Montreal, Quebec H3T 1E2, Canada. E-mail marke{at}epid.jgh.mcgill.ca
Key Words: restenosis stents drugs
| Introduction |
|---|
|
|
|---|
| Human Studies |
|---|
|
|
|---|
Non-Randomized Studies
Stents Coated with Biocompatible Materials
The biocompatibility of stents coated with several materials, including carbon, gold, silicon carbide, and phosphorylcholine, has been investigated in humans. The Carbostent (Sorin Biomedica Cardio) is a metal stent coated with a carbon film that is thought to be less thrombogenic than uncoated steel stents.8 Antoniucci et al9 investigated the long-term biocompatibility of the Carbostent in a group of 112 patients with an intermediate risk of developing restenosis. Six-month follow-up revealed low MACE and restenosis rates of 12% and 11%, respectively. A second study in another group of 112 patients at high risk for restenosis resulted in a MACE rate of 20% and a binary restenosis rate of 25% by 6 months.10 These results suggest that the Carbostent is well tolerated in vivo and possibly inhibits neointimal hyperplasia, especially in high-risk patients (Table 1).
|
Gold has been touted as a biocompatible material and has been thought to be ideal for coating coronary stents because of its radio-opaque properties.1 Two studies evaluating the biocompatibility of gold-coated stents suggested equivalency with uncoated steel stents.11,12 However, two other studies concluded that these stents may increase neointimal hyperplasia compared with uncoated stents, although patients at a higher risk for restenosis were enrolled.13,14 Follow-up angiography at 6 months demonstrated a relatively high lumen late loss (postintervention minimum luminal diameter minus the minimum luminal diameter at follow-up) and diameter stenosis in both studies (Table 1). Overall, there have been conflicting results in observational studies examining gold-coated stents, and the restenosis rates seem to be no better than those obtained with uncoated steel stents.
Silicon carbide is an inert semiconductor that can be coated onto prosthetic surfaces and has been shown to be relatively biocompatible and hemocompatible in in vitro studies.15,16 Stents coated with silicon carbide also appear to be less thrombogenic than bare metal stents when implanted in human coronary arteries.17 In an observational study of 165 patients, Heublein et al18 reported a MACE rate of 32%, with a propensity for more events in higher risk patients. Follow-up angiography was done only on 27% of patients who developed symptoms after stent implantation, and revealed a restenosis rate of 36% by 5 months. Silicon carbide-coated stents were used in the stent arm of a clinical trial comparing balloon angioplasty alone with balloon angioplasty plus stenting in the setting of an acute myocardial infarction.19 Long-term follow-up results of the stent arm of this study suggest that silicon carbide-coated stents did not significantly decrease restenosis rates. Two other observational studies have been published with similar clinical event rates.20,21 A major limitation of most of these studies is the lack of routine follow-up angiography. Overall, silicon carbide-coated stents do not appear to have a significant effect on restenosis (Table 1).
Five nonrandomized studies have evaluated the properties of stents coated with phosphorylcholine, a naturally occurring phospholipid polymer. In a study of 224 patients, Zheng et al22 reported a MACE rate of 9% on the basis of clinical follow-up of 132 patients at 6 months. Repeat angiography was performed in only 28 patients, 8 of whom had angiographically documented in-stent restenosis. In a similar study of 218 consecutive patients who received a phosphorylcholine-coated stent, Galli et al23 reported a 6-month MACE rate of 13%, confirming that this type of stent is very well tolerated in humans. The same group24 showed that phosphorylcholine coated stents had low rates of subacute stent thrombosis (0%) and restenosis (12%), even when used in the setting of primary PCI for acute myocardial infarction.
Phosphorylcholine-coated stents have also been examined in the setting of PCI of small coronary vessels. In a retrospective series of 90 patients undergoing stenting of vessels 2.0 to 2.8 mm in diameter, Beaudry et al25 reported a MACE rate of 20%. Similar results have been obtained after deploying these stents in vessels <2.0 mm in diameter.26 Unfortunately, the lack of routine follow-up angiography is the major limitation of these 5 studies, and although well tolerated, it is unclear if phosphorylcholine-coated stents inhibit neointimal hyperplasia to a significant degree (Table 2).
|
Stents Coated with Heparin
Observational studies in animals have suggested that heparin-coated stents may decrease rates of subacute thrombosis and inhibit neointimal hyperplasia (see Part I of this review). Small series such as that by Atalar et al27 have demonstrated the safety of heparin-coated stents in humans. The Heparin-Coated Wiktor Stents in Human Coronary Arteries (MENTOR) study was a prospective study of 132 patients undergoing implantation of heparin-coated stents in coronary lesions at low risk of restenosis.28 The MACE rate was 15% at 6 months and the binary restenosis rate was 22% (Table 2). These results are comparable to those in previous studies using uncoated stents, such as in the stent arm of the first Belgium Netherlands Stent trial.29
Results suggesting equivalency between uncoated and heparin-coated stents in low risk lesions prompted other investigators to test the efficacy of heparin-coated stents in more complex lesions. Van Langenhove et al30 reported a MACE rate of only 10% and a binary restenosis rate of 22% at 6 months when heparin-coated stents were implanted in saphenous vein grafts.30 Shin et al31 assessed the efficacy of heparin-coated stents in 102 patients with an acute myocardial infarction undergoing primary PCI. Standard oral antiplatelet agents were given, but patients were not treated with intravenous heparin or glycoprotein IIb/IIIa inhibitors after stent deployment. Clinical and angiographic follow-up at 2 weeks did not reveal any findings of subacute stent thrombosis, and follow-up at 6 months revealed a MACE rate of 14% and an angiographic restenosis rate of 17%. The results of these 2 studies compare favorably with those of prior studies using uncoated stents in comparable patient populations.32,33
Several prospective studies comparing balloon angioplasty alone with balloon angioplasty plus stent implantation in treating coronary stenoses have used heparin-coated stents.3436 The primary objective of these trials was not to compare heparin-coated stents with uncoated steel stents, but rather to examine the effect of coronary stenting on restenosis rates after PCI. In 3 clinical trials, patients were randomized to either balloon angioplasty alone or balloon angioplasty with the implantation of heparin-coated stents. In those patients who had heparin-coated stents implanted, the 6-month MACE rates ranged from 13% to 16%, and the binary restenosis rates ranged from 16% to 55% (Table 2). Heparin-coated stents have also been evaluated in small coronary arteries (2.1 to 3.0 mm in diameter) and have shown promising results, with a MACE rate of only 10% and a binary restenosis rate of 10% at 6 months.37 The low clinical event rates were maintained at 1-year follow-up.38 These results also compare well with the results of other studies investigating uncoated stents in small-caliber coronary vessels.39,40
The characteristics of the treated lesions and the study protocols differ among the studies investigating heparin-coated stents, making comparisons with earlier studies difficult. Generally speaking, the results of these studies suggest that heparin-coated stents are well tolerated. Although the rate of subacute thrombosis for these stents seems to be lower than for uncoated steel stents, these stents do not seem to have a significant long-term impact on either MACE or restenosis rates when compared with uncoated stents (Table 2).
Stents Coated With Corticosteroids and Antimitotic Agents
In contrast with animal studies, there have been no published nonrandomized studies in humans examining stents coated with corticosteroids, and only a few studies have been published examining stents coated with antimitotic agents (Table 3).
|
The First In Man (FIM) study was the first published nonrandomized study in humans to investigate stents coated with antimitotic agents. It was conducted jointly in Brazil and Europe to assess the efficacy of sirolimus-coated stents in inhibiting neointimal hyperplasia.4143 In the Brazilian cohort, 30 patients with low-risk lesions were randomized to receive either a fast-release sirolimus-coated stent (drug elution <15 days) or a slow-release sirolimus-coated stent (drug elution >28 days). The patients had quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS) done at 4 months, with clinical follow-up at 8 months.41 No patient had binary restenosis shown by QCA, and all patients had <20% diameter stenosis by IVUS. No MACE had occurred by 8 months. There was also no difference in clinical or angiographic end points between the fast-release and slow-release formulations. The 1-year follow-up results of this cohort have also been published, showing essentially unchanged QCA variables.42 Only 1 MACE occurred by the 15-month clinical follow-up (Table 3).
Rensing et al43 published the European experience with the sirolimus-coated stent in 15 patients undergoing PCI as part of the FIM study. All stents contained the slow-release formulation of sirolimus. There were QCA and IVUS follow-up at 6 months and clinical follow-up at 9 months. The angiographic restenosis rate was 0%, with IVUS demonstrating a mean in-stent late loss of 0.0 mm (range -0.37 to 0.25 mm). There was 1 death due to an intracranial hemorrhage. The combined Brazilian and European results of the FIM study show no binary restenosis and no MACE up to 12 months, suggesting that both fast-release and slow-release sirolimus-coated stents have a potent inhibitory effect on neointimal hyperplasia in humans.
QP2, a taxane analogue structurally similar to paclitaxel, is another agent whose efficacy at inhibiting neointimal hyperplasia has been investigated in humans. In a study of 14 patients, Honda et al44 reported a binary restenosis rate of 0%. Only a minimal amount of neointimal proliferation was visible by IVUS by the 8-month follow-up period. The authors reported a significant increase in plaque area immediately proximal and distal to the stents, however, leading to revascularization procedures in 2 patients. These observations have caused concern about the possibility of edge restenosis with stents coated with antimitotic agents similar to that seen with radioactive stents.45 A cohort of 32 patients in Argentina who had QP2-coated stents inserted were reported to be clinically asymptomatic up to 2 years after stent implantation.46 QCA and IVUS demonstrated a 0% binary restenosis rate in a subgroup of 13 patients who underwent repeat cardiac catheterization (Table 3). Interestingly, 5 patients in this study had the QP2-coated stent deployed within a previously implanted stent with in-stent restenosis. Edge restenosis was not reported in the subgroup that underwent IVUS.
The efficacy of QP2-coated stents at reducing restenosis when inserted in lesions with preexisting in-stent restenosis has also been investigated in 1 study.47 The baseline patient and lesion characteristics predicted a high risk of restenosis. The 6-month clinical and QCA results suggested efficacy at reducing in-stent restenosis (MACE rate of 40% and binary restenosis rate of 13%). By the 12 month follow-up period, however, 87% of the patients had experienced a MACE and 62% of the implanted stents were restenotic (Table 3). These results suggest that QP2-coated stents may delay but do not decrease restenosis in lesions with preexisting neointimal hyperplasia.
In summary, observational studies in humans suggest that stents coated with inert materials do not have a significant impact on restenosis. It is unclear if phosphorylcholine-coated stents decrease restenosis rates, but they appear to be well tolerated and have the added advantage of potentially acting as a reservoir of an antiproliferative agent for drug elution. Heparin-coated stents reduce subacute thrombosis but do not have a significant inhibitory effect on neointimal hyperplasia. Several small observational studies examining stents coated with antimitotic agents in humans suggest that they have a potent inhibitory effect on neointimal hyperplasia. Sirolimus-coated stents have demonstrated a significant inhibitory effect on restenosis, although it is unclear if this antiproliferative effect will be sustained over the long term. The results of 3 studies investigating stents coated with QP2, a taxane analogue, are less conclusive. QP2-coated stents appear to have an antiproliferative effect, but do not significantly alter restenosis rates in high-risk lesions. Excessive proliferation of atherosclerotic plaques immediately proximal and distal to the site of stent insertion has also been reported with QP2 coated stents.
Clinical Trials
There are only a few published randomized clinical trials evaluating the efficacy of coated stents, although several have released results in abstract form, and several more are currently in progress.
Stents Coated With Biocompatible Materials
Three randomized, controlled, nonblinded clinical trials have evaluated the efficacy of gold-coated stents at reducing restenosis rates. Kastrati et al48 randomized 731 patients to receive either a gold-coated stent or an uncoated stent. Although there was no difference between the 2 groups with regard to acute and subacute events or survival, there was a significant difference in MACE rates at 1 year, with a worse outcome in the gold-coated stent group (26.1% uncoated versus 37.1% gold-coated, P=0.001). Results of angiographic variables such as binary restenosis, luminal late loss, and percent diameter stenosis also showed a worse outcome, suggesting that gold-coated stents actually increase the risk of restenosis when used in complex lesions (Table 4). Smaller clinical trials by vom Dahl et al49 and Park et al50 that enrolled a total of 420 patients have published similar results, demonstrating a worse outcome in the gold-coated stent arms of the trials. The authors of these studies concluded that gold-coated stents appear to exaggerate the proliferative response after PCI when implanted in complex lesions (Table 4).
|
Stents Coated With Heparin
To our knowledge, only 1 clinical trial comparing heparin-coated stents with uncoated stents for the prevention of restenosis has been published. Wohrle et al51 randomized 277 patients with predominantly complex lesions to receive either heparin-coated or uncoated stents. The heparin was eluted from the stents by a polyamine (polymer) coating previously shown to be inert. Clinical and angiographic follow-up at 6 months did not reveal a significant difference between the 2 groups in restenosis rates (heparin-coated 33.1% versus uncoated 30.3%) or MACE (heparin-coated 25.2% versus uncoated 25.7%). The results of this trial are consistent with those of nonrandomized studies and suggest that heparin-coated stents do not have a significant impact on in-stent restenosis.
Stents Coated With Antimitotic Agents
The RAndomized study with the Sirolimus-coated BX VELocity balloon expandable stent in the treatment of patients with de novo native coronary artery lesions (RAVEL) was a randomized, double-blind, controlled trial that evaluated a sirolimus-coated stent in humans.52 The sirolimus was blended with a mixture of polymers to achieve programmed elution of most of the drug within 30 days. Two hundred thirty-eight patients with low-risk lesions in native coronary arteries were randomized to receive either a sirolimus-coated stent (n=120) or an uncoated steel stent (n=118). All patients were treated with either clopidogrel or ticlopidine for 8 weeks following PCI. Follow-up at 1 year revealed a remarkable difference in the primary clinical end-point of MACE between the sirolimus-coated and the uncoated stent groups (5.8% versus 28.8%, P<0.001). Only 1 patient in the sirolimus-coated stent group had a MACE that was attributable to the stented vessel. The difference in the MACE rates between the 2 groups was primarily due to a difference in rates of percutaneous revascularization of the target lesion. Angiographic follow-up at 6 months also revealed a significant difference in the primary angiographic end-point of luminal late loss. The binary restenosis rate was 0% among patients who received a sirolimus-coated stent compared with a 26.6% restenosis rate for patients who received an uncoated stents (Table 4). No edge restenosis or delayed stent thrombosis occurred in the sirolimus group. The angiographic findings were confirmed in a subset of 95 patients who underwent IVUS in both arms of the trial.53
Four other clinical trials investigating stents eluting antimitotic agents have released preliminary results in abstract form at recent conferences, although they remain unpublished (Table 4). The ASian Paclitaxel-Eluting stent Clinical Trial (ASPECT) was a 177 patient prospective, multicenter, double-blind study comparing stents coated with 2 different concentrations of paclitaxel (high-dose, 3.1 µg/mm2 or low-dose, 1.3 µg/mm2) versus uncoated stents.54 Paclitaxel did not have a carrier polymer in this study. At 6 months, the angiographic parameters of percent diameter stenosis (14±21% versus 39±27%) and binary restenosis (4% versus 27%) were both decreased significantly in the high-dose group compared with the uncoated stents (P<0.001). The MACE rates for this trial have not yet been published.
The EvaLUation of PacliTaxel-Eluting Stents (ELUTES) trial randomized 192 patients in Europe with low-risk lesions in native coronary arteries to receive either an uncoated stent or a paclitaxel-coated stent with no carrier polymer in 4 different concentrations: 0.2 µg/mm2, 0.7 µg/mm2, 1.4 µg/mm2, or 2.7 µg/mm2.55 All patients were treated with aspirin and clopidogrel for 3 months. There was no difference in the 6-month MACE rates between the paclitaxel-coated and uncoated stent (11% in both groups). The binary restenosis rate, however, was 3% in the highest-dose paclitaxel group versus 21% in patients that received uncoated stents (P=0.055). The late loss and percent diameter stenosis were both in favor of the paclitaxel-stent group (P<0.01) (Table 4).
The TAXUS I trial was a double-blind randomized trial comparing uncoated stents (n=30) with paclitaxel-coated stents (n=31).56 Patients were treated with clopidogrel for 6 months. The angiographic results at 6 months have been reported to be in favor of the coated stent group (diameter stenosis 13±12% versus 27±17%, P<0.0005, and binary restenosis 0% versus 11%, P=0.106), although the difference in binary restenosis rates was not statistically significant.
Finally, the Study to COmpare REstenosis rates between QueST and QuaDDS-QP2 (SCORE) was a randomized multicenter trial that was terminated prematurely after interim analysis showed a dramatically increased predisposition for subacute and delayed stent thrombosis (9.4%) in the QP2-stent group compared with the uncoated stent group (0%).57 The 6-month angiographic results suggest that these stents inhibit neointimal hyperplasia, even after accounting for the excessive stent thrombosis rates in the QP2-stent group (Table 4).58
In summary, the results of 4 clinical trials investigating gold-coated and heparin-coated stents do not show any benefit with respect to reducing MACE or restenosis. Gold-coated stents may in fact confer a worse outcome compared with uncoated stents. There are no published trials evaluating corticosteroid-coated stents. Several small clinical trials assessing the efficacy of stents coated with antimitotic agents (sirolimus and paclitaxel) at reducing restenosis have been completed. The patients enrolled in these trials have had lesions in native coronary arteries at a low-risk for developing in-stent restenosis, but have demonstrated significant reductions in MACE and binary restenosis rates over 6 to 12 months. A total of 942 patients have been enrolled in these trials, but long-term follow-up results are not yet available.
Clinical Trials in Progress
Many trials evaluating drug-eluting stents are currently in progress (Table 5). These may enroll close to 6000 patients and involve stents coated with agents aimed at inhibiting cell proliferation (sirolimus, paclitaxel, and tacrolimus), cell migration (batimastat, a matrix metalloproteinase inhibitor), and abnormal healing (estradiol). Recruitment in the ACTinomycin-eluting stent Improves Outcomes by reducing Neointimal hyperplasia (ACTION) trial59 was stopped after interim analysis of the first 90 enrolled patients showed an above average restenosis rate in patients randomized to both coated stent and uncoated stent arms of the trial. Recruitment in the European Batimastat (BB-94) antiRestenosis trIaL utiLizIng the BiodivYsio locAl drug delivery PC steNT (BRILLIANT) II trial60 investigating phosphorylcholine-coated stents eluting batimastat was also suspended after an interim analysis demonstrated a lack of efficacy.
|
| Complications and Controversies |
|---|
|
|
|---|
| Conclusions |
|---|
|
|
|---|
Note Added in Proof
After this article went into publication, preliminary results of SIRIUS and TAXUS II were released at a recent interventional cardiology conference. The results are available at http://www.clinicaltrialresults.com.
| Acknowledgments |
|---|
| Footnotes |
|---|
| References |
|---|
|
|
|---|
2. Edelman ER, Rogers C. Stent-versus-stent equivalency trials: are some stents more equal than others? Circulation. 1999; 100: 896898.
3. Manolis AS. Reduced incidence of clinical restenosis with newer generation stents, stent oversizing and high-pressure deployment: single operator experience Clin Cardiol. 2001; 24: 119126.[Medline] [Order article via Infotrieve]
4. Hoffmann R, Jansen C, Konig A, et al. Stent design related neointimal tissue proliferation in human coronary arteries: an intravascular ultrasound study. Eur Heart J. 2001; 22: 20072014.
5. Kastrati A, Mehilli J, Dirschinger J, et al. Restenosis after coronary placement of various stent types. Am J Cardiol. 2001; 87: 3439.[Medline] [Order article via Infotrieve]
6. Bauters C, Hubert E, Prat A, et al. Predictors of restenosis after coronary stent implantation. J Am Coll Cardiol. 1998; 31: 12911298.
7. Kastrati A, Schomig A, Elezi S, et al. Predictive factors of restenosis after coronary stent placement. J Am Coll Cardiol. 1997; 30: 14281436.[Abstract]
8. Bartorelli AL, Trabattoni D, Montorsi P, et al. Aspirin alone antiplatelet regimen after intracoronary placement of the Carbostent: the ANTARES study. Catheter Cardiovasc Interv. 2002; 55: 150156.[CrossRef][Medline] [Order article via Infotrieve]
9. Antoniucci D, Bartorelli A, Vaenti R, et al. Clinical and angiographic outcome after coronary artery stenting with the Carbostent. Am J Cardiol. 2000; 85: 821825.[CrossRef][Medline] [Order article via Infotrieve]
10. Antoniucci D, Valenti R, Migliorini A, et al. Clinical and angiographic outcomes following elective implantation of the Carbostent in patients at high risk of restenosis and target vessel failure. Cathet Cardiovasc Interv. 2001; 54: 420426.[CrossRef][Medline] [Order article via Infotrieve]
11. Harding SA, McKenna CJ, Flapan AD, et al. Long-term clinical safety and efficacy of NIROYAL vs NIR intracoronary stent. Cath Cardiovasc Interv. 2001; 54: 141145.[CrossRef]
12. Cremonesi A, Benit E, Carlier M, et al. Multicenter registry to evaluate the efficacy of the NIROYAL stent in de novo and restenotic coronary arteries. J Invas Cardiol. 2000; 12: 225232.[Medline] [Order article via Infotrieve]
13. Danzi GB, Capuano C, Sesana M, et al. Patterns of in-stent restenosis after placement of NIR gold-coated stents in unselected patients. Catheter Cardiovasc Interv. 2002; 55: 157162.[CrossRef][Medline] [Order article via Infotrieve]
14. Hoffmann R, Mintz GS, Haager PK, et al. Relation of stent design and stent surface material to subsequent in-stent intimal hyperplasia in coronary arteries determined by intravascular ultrasound. Am J Cardiol. 2002; 89: 13601364.[CrossRef][Medline] [Order article via Infotrieve]
15. Aspenberg P, Anttila A, Konttinen YT, et al. Benign response to particles of diamond and SiC: bone chamber studies of new joint replacement coating materials in rabbits. Biomaterials. 1996; 17: 807812.[CrossRef][Medline] [Order article via Infotrieve]
16. Monnink SH, van Boven AJ, Peels HO, et al. Silicon-carbide coated coronary stents have low platelet and leukocyte adhesion during platelet activation. J Investig Med. 1999; 47: 304310.[Medline] [Order article via Infotrieve]
17. Heublein B, Ozbek C, Pethig K. Silicon carbide-coated stents: clinical experience in coronary lesions with increased thrombotic risk. J Endovasc Surg. 1998; 5: 3241.[CrossRef][Medline] [Order article via Infotrieve]
18. Heublein B, Pethig K, Elsayed AM. Silicon carbide coating: a semiconducting hybrid design of coronary stents: a feasibility study. J Invas Cardiol. 1998; 10: 255262.[Medline] [Order article via Infotrieve]
19. Scheller B, Hennen B, Severin-Kneib S, et al. Long-term follow-up of a randomized study of primary stenting versus angioplasty in acute myocardial infarction. Am J Med. 2001; 110: 16.[Medline] [Order article via Infotrieve]
20. Carrie D, Khalife K, Hamon M, et al. Initial and follow-up results of the Tenax coronary stent. J Interv Cardiol. 2001; 14: 15.[Medline] [Order article via Infotrieve]
21. Kalnins U, Erglis A, Dinne I, et al. Clinical outcomes of silicon carbide coated stents in patients with coronary artery disease. Med Sci Monit. 2002; 8: 1620.
22. Zheng H, Barragan P, Corcos T, et al. Clinical experience with a new biocompatible phosphorylcholine-coated coronary stent. J Invas Cardiol. 1999; 11: 608614.[Medline] [Order article via Infotrieve]
23. Galli M, Bartorelli A, Bedogni F, et al. Italian BiodivYsio open registry (BiodivYsio PC-coated stent): study of clinical outcomes of the implant of a PC-coated coronary stent. J Invas Cardiol. 2000; 12: 452458.[Medline] [Order article via Infotrieve]
24. Galli M, Sommariva L, Prati F, et al. Acute and mid-term results of phosphorylcholine coated stents in primary coronary stenting for acute myocardial infarction. Cath Cardiovasc Interv. 2001; 53: 182187.[CrossRef]
25. Beaudry Y, Sze S, Fagih B, et al. Six-month results of small vessel stenting (2.02.8 mm) with the Biodivysio SV stent. J Invas Cardiol. 2001; 13: 628631.[Medline] [Order article via Infotrieve]
26. Grenadier E, Roguin A, Hertz I, et al. Stenting very small coronary narrowings (<2 mm) using the biocompatible phosphorylcholine-coated coronary stent. Cathet Cardiovasc Interv. 2002; 55: 303308.[CrossRef][Medline] [Order article via Infotrieve]
27. Atalar E, Haznedaroglu I, Aytemir K, et al. Effects of stent coating on platelets and endothelial cells after coronary stent implantation. Clin Cardiol. 2001; 24: 159164.[Medline] [Order article via Infotrieve]
28. Vrolix MC, Legrand VM, Reiber JH, et al. Heparin-coated Wiktor stents in human coronary arteries (MENTOR trial). MENTOR Trial Investigators. Am J Cardiol. 2000; 86: 385389.[CrossRef][Medline] [Order article via Infotrieve]
29. Serruys PW, de Jaegere P, Kiemeneij F, et al. A comparison of balloon expandable stent implantation with balloon angioplasty in patients with coronary artery disease: The BENESTENT study group. N Eng J Med. 1994; 331: 489495.
30. Van Langenhove G, Vermeersch P, Serrano P, et al. Saphenous vein graft disease treated with the Wiktor Hepamed stent: procedural outcome, in-hospital complications and six-month angiographic follow-up. Can J Cardiol. 2000; 16: 473480.[Medline] [Order article via Infotrieve]
31. Shin EK, Son JW, Sohn MS, et al. Efficacy of heparin-coated stent in early setting of acute myocardial infarction. Catheter Cardiovasc Interv. 2001; 52: 306312.[CrossRef][Medline] [Order article via Infotrieve]
32. Savage MP, Douglas JS Jr, Fischman DL, et al. Stent placement compared with balloon angioplasty for obstructed coronary bypass grafts. Saphenous Vein De Novo Trial Investigators. N Engl J Med. 1997; 337: 740747.
33. Stone GW, Brodie BR, Griffin JJ, et al. Clinical and angiographic follow-up after primary stenting in acute myocardial infarction: the Primary Angioplasty in Myocardial Infarction (PAMI) stent pilot trial. Circulation. 1999; 99: 15481554.
34. Serruys PW, van Hout B, Bonnier H, et al. Randomized comparison of heparin-coated stents with balloon angioplasty in selected patients with coronary artery disease (BENESTENT II). Lancet. 1998; 352: 673681.[CrossRef][Medline] [Order article via Infotrieve]
35. Buller CE, Dzavic V, Carere RJ, et al. Primary stenting versus balloon angioplasty in occluded coronary arteries: the Total Occlusion Study of Canada (TOSCA). Circulation. 1999; 100: 236242.
36. Grines CL, Cox DA, Stone GW, et al. Coronary angioplasty with or without stent implantation for acute myocardial infarction. N Eng J Med. 1999; 341: 19491956.
37. Moer R, Myreng Y, Molstad P, et al. Stenting in small coronary arteries (SISCA) trial: a randomized comparison between balloon angioplasty and the heparin-coated beStent. J Am Coll Cardiol. 2001; 38: 15981603.
38. Moer R, Myreng Y, Molstad P, et al. Clinical benefit of small vessel stenting: one-year follow-up of the SISCA trial. Scand Cardiovasc J. 2002; 36: 8690.[CrossRef][Medline] [Order article via Infotrieve]
39. Kastrati A, Schomig A, Dirschinger J, et al. A randomized trial comparing stenting with balloon angioplasty in small vessels in patients with symptomatic coronary artery disease. ISAR-SMART Study Investigators: Intracoronary Stenting or Angioplasty for Restenosis Reduction in Small Arteries. Circulation. 2000; 102: 25932598.
40. Muramatsu T, Tsukahara R, Ho M, et al. Clinical outcome of stent implantation in small coronary arteries using different types of coronary stents. J Invasive Cardiol. 2001; 13: 634649.[Medline] [Order article via Infotrieve]
41. Sousa E, Costa M, Abizaid A, et al. Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries. Circulation. 2001; 103: 192195.
42. Sousa JE, Costa MA, Abizaid AC, et al. Sustained suppression of neointimal proliferation by sirolimus-eluting stents: one-year angiographic and intravascular ultrasound follow-up. Circulation. 2001; 104: 20072011.
43. Rensing BJ, Vos J, Smits PC, et al. Coronary restenosis elimination with a sirolimus eluting stent. Eur Heart J. 2001; 222: 21252130.
44. Honda Y, Grube E, de la Fuente LM, et al. Novel drug delivery stent: intravascular ultrasound observations from the first human experience with the QP2-eluting polymer stent system. Circulation. 2001; 104: 380383.
45. Sheppard R, Eisenberg MJ. Intracoronary radiotherapy for restenosis. N Engl J Med. 2001; 344: 295297.
46. de la Fuente LM, Miano J, Mrad J, et al. Initial results of the Quanam drug eluting stent (QuaDS-QP-2) Registry (BARDDS) in human subjects. Catheter Cardiovasc Interv. 2001; 53: 480488.[CrossRef][Medline] [Order article via Infotrieve]
47. Liistro F, Stankovic G, Di Mario C, et al. First clinical experience with a paclitaxel derivate-eluting polymer stent system implantation for in-stent restenosis: immediate and long-term clinical and angiographic outcome. Circulation. 2002; 105: 18831886.
48. Kastrati A, Schomig A, Dirschinger J, et al. Increased risk of restenosis after placement of gold-coated stents. Circulation. 2000; 101: 24782483.
49. vom Dahl J, Haager PK, Grube E, et al. Effect of gold coating of coronary stents on neointimal proliferation following stent implantation. Am J Cardiol. 2002; 89: 801805.[CrossRef][Medline] [Order article via Infotrieve]
50. Park SJ, Lee CW, Hong MK, et al. Comparison of gold-coated NIR stents with uncoated NIR stents in patients with coronary artery disease. Am J Cardiol. 2002; 89: 872875.[CrossRef][Medline] [Order article via Infotrieve]
51. Wohrle J, Al-Khayer E, Grotzinger U, et al. Comparison of the heparin coated vs. the uncoated Jostent: no influence on restenosis or clinical outcome. Eur Heart J. 2001; 22: 18081816.
52. Morice M-C, Serruys PW, Sousa JE, et al. A randomized comparison of a Sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med. 2002; 346: 17731780.
53. Serruys PW, Degertekin M, Tanabe K, et al. Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial. Circulation. 2002; 106: 798803.
54. Park SJ, Shim WH, Ho DS, et al. The clinical effectiveness of paclitaxel-coated coronary stents for the reduction of restenosis in the ASPECT trial. Circulation. 2001; 104 (suppl II): II464. Abstract.
55. Gershlick AH, De Scheerder I, Chevalier B, et al. Local drug delivery to inhibit coronary artery restenosis: data from the ELUTES (Evaluation of Paclitaxel Eluting Stent) clinical trial. Circulation. 2001; 104 (suppl II): II416. Abstract.
56. Grube E, Silber SM, Hauptmann KE, et al. TAXUS I: prospective, randomized, double-blind comparison of NIRx stents coated with paclitaxel in carrier de novo coronary lesions compared with uncoated controls. Circulation. 2001; 104 (suppl II): II463. Abstract.
57. Grube E, Hauptmann K, Colombo A, et al. SCORE trial interim safety results: despite efficacy, late stent thrombosis with the QuaDDS-QP2 stent. J Am Coll Cardiol. 2002; 39 (suppl A): 38A. Abstract.
58. Grube E, Lansky AJ, Reifart N, et al. SCORE six-month angiographic results: improved restenosis in patients with receiving the QuaDDS-QP2 drug-eluting stent compared with the control, bare stents. J Am Coll Cardiol. 2002; 39 (suppl A): 59A. Abstract.
59. American College of Cardiology. Presented at: European Society of Cardiology XXIV Annual Meeting. Berlin, Germany: August 31 through September 4, 2002. Available at http://www.accitalia.it/congress_centre/meeting_int/detail.asp?acr_trial=action. Accessed October 22, 2002.
60. British Biotech. Suspension of patient recruitment in the BRILLIANT II clinical trial for the Batimastat BiodivYsio stent. Available at http://www.britbio.co.uk/news/2002%20news/stentsuspen.htm. Accessed October 22, 2002.
61. Farb A, Heller PF, Shroff S, et al. Pathological analysis of local delivery of Paclitaxel via a polymer-coated stent. Circulation. 2001; 104: 473479.
62. Liistro F, Colombo A. Late acute thrombosis after paclitaxel eluting stent implantation. Heart. 2001; 86: 262264.
63. Kay IP, Wardeh AJ, Kozuma K, et al. Radioactive stents delay but do not prevent in-stent neointimal hyperplasia. Circulation. 2001; 103: 1417.
This article has been cited by other articles:
![]() |
K. Nakano, K. Egashira, S. Masuda, K. Funakoshi, G. Zhao, S. Kimura, T. Matoba, K. Sueishi, Y. Endo, Y. Kawashima, et al. Formulation of Nanoparticle-Eluting Stents by a Cationic Electrodeposition Coating Technology: Efficient Nano-Drug Delivery via Bioabsorbable Polymeric Nanoparticle-Eluting Stents in Porcine Coronary Arteries J. Am. Coll. Cardiol. Intv., April 1, 2009; 2(4): 277 - 283. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Egashira, K. Nakano, K. Ohtani, K. Funakoshi, G. Zhao, Y. Ihara, J.-i. Koga, S. Kimura, R. Tominaga, and K. Sunagawa Local Delivery of Anti-Monocyte Chemoattractant Protein-1 by Gene-Eluting Stents Attenuates In-Stent Stenosis in Rabbits and Monkeys Arterioscler. Thromb. Vasc. Biol., December 1, 2007; 27(12): 2563 - 2568. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Airoldi, A. Colombo, N. Morici, A. Latib, J. Cosgrave, L. Buellesfeld, E. Bonizzoni, M. Carlino, U. Gerckens, C. Godino, et al. Incidence and Predictors of Drug-Eluting Stent Thrombosis During and After Discontinuation of Thienopyridine Treatment Circulation, August 14, 2007; 116(7): 745 - 754. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Bode and M. Zehender The use of antiplatelet agents following percutaneous coronary intervention: focus on late stent thrombosis Eur. Heart J. Suppl., August 1, 2007; 9(suppl_D): D10 - D19. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Ohtani, K. Egashira, K. Nakano, G. Zhao, K. Funakoshi, Y. Ihara, S. Kimura, R. Tominaga, R. Morishita, and K. Sunagawa Stent-Based Local Delivery of Nuclear Factor-{kappa}B Decoy Attenuates In-Stent Restenosis in Hypercholesterolemic Rabbits Circulation, December 19, 2006; 114(25): 2773 - 2779. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Eisenberg Drug-Eluting Stents: The Price Is Not Right Circulation, October 17, 2006; 114(16): 1745 - 1754. [Full Text] [PDF] |
||||
![]() |
C. S. Karyekar, R. S. Pradhan, T. Freeney, Q. Ji, T. Edeki, W. Chiu, W. M. Awni, C. Locke, L. B. Schwartz, R. G. Granneman, et al. A Phase I Multiple-Dose Escalation Study Characterizing Pharmacokinetics and Safety of ABT-578 in Healthy Subjects J. Clin. Pharmacol., August 1, 2005; 45(8): 910 - 918. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Windecker, R. Simon, M. Lins, V. Klauss, F. R. Eberli, M. Roffi, G. Pedrazzini, T. Moccetti, P. Wenaweser, M. Togni, et al. Randomized Comparison of a Titanium-Nitride-Oxide-Coated Stent With a Stainless Steel Stent for Coronary Revascularization: The TiNOX Trial Circulation, May 24, 2005; 111(20): 2617 - 2622. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. J. Birdas, J. T. Landis, D. Haybron, D. Evers, P. K. Papasavas, and P. F. Caushaj Outcomes of Coronary Artery Bypass Grafting in Patients With Connective Tissue Diseases Ann. Thorac. Surg., May 1, 2005; 79(5): 1610 - 1614. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. G. Ellis, J. J. Popma, J. M. Lasala, J. J. Koglin, D. A. Cox, J. Hermiller, C. O'Shaughnessy, J. T. Mann, M. Turco, R. Caputo, et al. Relationship between angiographic late loss and target lesion revascularization after coronary stent implantation: Analysis from the TAXUS-IV trial J. Am. Coll. Cardiol., April 19, 2005; 45(8): 1193 - 1200. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Fajadet, M.-C. Morice, C. Bode, P. Barragan, P. W. Serruys, W. Wijns, C. R. Constantini, J.-L. Guermonprez, H. Eltchaninoff, D. Blanchard, et al. Maintenance of Long-Term Clinical Benefit With Sirolimus-Eluting Coronary Stents: Three-Year Results of the RAVEL Trial Circulation, March 1, 2005; 111(8): 1040 - 1044. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Naka, L. G. Bucciarelli, T. Wendt, L. K. Lee, L. L. Rong, R. Ramasamy, S. F. Yan, and A. M. Schmidt RAGE Axis: Animal Models and Novel Insights Into the Vascular Complications of Diabetes Arterioscler. Thromb. Vasc. Biol., August 1, 2004; 24(8): 1342 - 1349. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. H Chong and J. W. Cheng Early Experiences and Clinical Implications of Restenosis and Drug-Eluting Stents: Part 2 Ann. Pharmacother., May 1, 2004; 38(5): 845 - 852. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. M. Mourani, P. J. Garl, J. M. Wenzlau, T. C. Carpenter, K. R. Stenmark, and M. C.M. Weiser-Evans Unique, Highly Proliferative Growth Phenotype Expressed by Embryonic and Neointimal Smooth Muscle Cells Is Driven by Constitutive Akt, mTOR, and p70S6K Signaling and Is Actively Repressed by PTEN Circulation, March 16, 2004; 109(10): 1299 - 1306. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. W. Stone, S. G. Ellis, D. A. Cox, J. Hermiller, C. O'Shaughnessy, J. T. Mann, M. Turco, R. Caputo, P. Bergin, J. Greenberg, et al. A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease N. Engl. J. Med., January 15, 2004; 350(3): 221 - 231. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. A. Lemos, P. W. Serruys, and J. E. Sousa Drug-Eluting Stents: Cost Versus Clinical Benefit Circulation, June 24, 2003; 107(24): 3003 - 3007. [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2002 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |