(Circulation. 2002;106:1090.)
© 2002 American Heart Association, Inc.
Clinical Investigation and Reports |
From Brigham and Womens Hospital (J.J.P., R.E.K.), Boston, Mass; University of Maryland (M.S.), Baltimore, Md; Lenox Hill Hospital (A.J.L.), New York, NY; Phoenix Heart Center (R.R.H., B.S.), Phoenix, Ariz; Scripps Clinic (P.S.T., V.M.), La Jolla, Calif; University of Florida (T.B., R.H.), Jacksonville; Dr. Mueller Hospital (S.S., P.v.R.), Munich, Germany; Montreal Heart Institute (R.B.), Montreal, Canada; Beth Israel Deaconess Medical Center (K.K.L.H.), Boston, Mass; and Harvard Clinical Research Institute (J.J.P., A.O., R.E.K.), Boston, Mass.
Correspondence to Jeffrey J. Popma, MD, Director, Interventional Cardiology, Brigham and Womens Hospital, 75 Francis St, L-2 Catheterization Laboratory, Boston, MA 02115. E-mail jpopma{at}partners.org
| Abstract |
|---|
|
|
|---|
Methods and Results After successful catheter-based treatment of in-stent restenosis, 476 patients were randomly assigned to receive an intracoronary catheter containing either 90Sr/90Y (n=244) or placebo (n=232) sources. The prescribed dose 2 mm from the center of the source was 18.4 Gy for vessels between 2.70 and 3.35 mm in diameter and 23.0 Gy for vessels between 3.36 and 4.0 mm. The primary end point, ie, clinically driven target-vessel revascularization by 8 months, was observed in 56 (26.8%) of the patients assigned to placebo and 39 (17.0%) of the patients assigned to radiation (P=0.015). The incidence of the composite including death, myocardial infarction, and target-vessel revascularization was observed in 60 (28.7%) of the patients assigned to placebo and 44 (19.1%) of the patients assigned to radiation (P=0.024). Binary 8-month angiographic restenosis (
50% diameter stenosis) within the entire segment treated with radiation was reduced from 45.2% in the placebo-treated patients to 28.8% in the 90Sr/90Y-treated patients (P=0.001). Stent thromboses occurred in 1 patient assigned to placebo <24 hours after the procedure and in 1 patient assigned to 90Sr/90Y at day 244.
Conclusions The results of this study demonstrated that ß-radiation using 90Sr/90Y is both safe and effective for preventing recurrence in patients with in-stent restenosis.
Key Words: restenosis stents angioplasty trials
| Introduction |
|---|
|
|
|---|
Three clinical trials in patients with in-stent restenosis have shown that compared with conventional PCI,
-radiation using 192Ir lowers the frequency restenosis.1113 These favorable results were sustained at 9 months but were tempered by the occurrence of late (>30-day) stent thrombosis in 5.3% of the patients.11 Episodes of late stent thrombosis were related to both the short duration (14 to 30 days) of ticlopidine therapy and the frequent (>80%) use of additional coronary stents.14
ß-Radiation using 90Y alone and 32P may also reduce the frequency of restenosis, 1517 but the utility of 90Sr/90Y brachytherapy in the setting of in-stent restenosis has not been tested. The purpose of the present study was to compare the safety and effectiveness of intracoronary 90Sr/90Y ß-radiation with placebo control after successful PCI in patients with in-stent restenosis.
| Methods |
|---|
|
|
|---|
20 mm in length and associated with objective evidence of myocardial ischemia. All patients were pretreated with aspirin (325 mg). After a successful angiographic result (<30% visual diameter stenosis) was obtained by using balloon angioplasty alone or in combination with rotational atherectomy, directional atherectomy, or excimer laser angioplasty, patients were randomly assigned to receive intracoronary treatment with 90Sr/90Y (n=244) or placebo (n=232). An activated clotting time between 275 and 300 seconds was obtained by using bolus unfractionated heparin. A 30-mm BetaCath radioactive source train (Novoste Corp) was used for lesions with a 20-mm balloon injury length (n=452); a 40-mm BetaCath source train was used for lesions with a 30-mm balloon injury length (n=24). Patients were excluded from the study if they had planned multivessel PCI, a recent (
72-hour) myocardial infarction (MI), unprotected left main coronary artery disease, 2 overlapping stents, a prior history of any chest radiotherapy, or prior stent placement for in-stent restenosis. Informed consent approved by a local institutional review board was obtained before the procedure in all patients.
Procedural Details
The BetaCath source delivery system had 2 components, a transfer device used to deliver the radiation source train to the treatment site and a 5F "over-the-wire" triple-lumen delivery catheter with a closed source lumen. The delivery catheter was advanced over a 0.014-in guidewire, and radiopaque marker bands on the delivery catheter were positioned on either side of the injured segment. Sterile water was then injected by using a syringe locked to the transfer device, causing hydraulic pressure to advance the active or placebo source from the transfer device to the end of the BetaCath delivery catheter.
The radioisotope used for the present study was 90Sr/90Y, which has a 28.1-year half-life. The mean activity of the 30-mm 12-source train was 39.96±2.5 mCi, and the mean dose rate was 0.0923±0.0058 Gy/s. The prescription point was 2 mm from the center line of the radiation source train. The dose prescription was 18.4 Gy for visual reference vessel sizes >2.7 mm and
3.35 mm and 23 Gy for visual reference vessel sizes >3.36 mm and
4.0 mm; the indwelling treatment time ranged from 3 to 5 minutes. After treatment, the sources were retrieved back into the transfer device, and the transfer device was separated from the delivery catheter and placed into a shielded storage. The use of PCI (including stents) after brachytherapy was discouraged and reserved for "bailout" indications (ie, >30% residual stenosis or a major dissection).18
After PCI, patients were given aspirin (325 mg daily) for the duration of the study. If a new stent was placed, patients enrolled from September 1998 until November 1998 also received ticlopidine (250 mg twice daily) for 14 days after the procedure. After November 1998, patients who received new stents were treated with ticlopidine (250 mg twice daily) or clopidogrel (75 mg daily) for at least 60 days after the procedure. Angiographic follow-up was obtained 8 months after the procedure, or sooner if recurrent symptoms developed.
Angiographic Analysis
All cineangiograms were forwarded to a central core laboratory for analysis with the use of standard criteria by observers blinded to the study protocol.19,20 Quantitative angiographic analysis was performed on 2 matched cine frames obtained before and after intervention and at follow-up. The following regions were analyzed by using a validated algorithm (Cardiovascular Measurement Systems; Leiden, the Netherlands)21: (1) the stent segment, which contained the entire axial length of the original stents; (2) the injured segment, which included the proximal and distal injured regions determined by the position of balloon; (3) the radiated segment, which included the proximal and distal location of the radiation source train; and (4) the analysis segment, which included a 5-mm segment proximal and distal to the regions of injury or radiation treatment. Semiquantitative measurements of the edges were obtained by using digital calipers. Geographic miss was defined as proximal or distal balloon injury that was not covered with any radiation treatment. By using the contrast-filled injection catheter as the reference standard, quantitative measures were obtained from the average proximal and distal reference segment and minimal lumen diameter (MLD). Late loss was calculated by the post-PCI MLD minus the follow-up MLD. Binary angiographic restenosis was defined as
50% follow-up diameter stenosis.
Clinical Outcomes
Death was reported as cardiac death and noncardiac death. MI was characterized as follows: Q-wave MI, defined as the development of new, pathological Q wave in
2 leads with postprocedural creatine kinase (CK) or CK-MB levels above normal, and non-Q-wave MI, defined as an elevation of the postprocedural CK levels to 2 times normal with CK-MB above normal. Device success was defined as the attainment of a <50% stenosis by quantitative analysis and the successful delivery of the radiation device. Procedural success was defined as the attainment of a residual stenosis <50% by quantitative analysis and no in-hospital major adverse cardiac events (MACEs), including death, MI, or emergency coronary artery bypass graft surgery (CABG) or repeat target-lesion PCI. Clinical stent thrombosis was defined as angiographic thrombus or subacute closure within the stented vessel at the time of clinically driven angiographic restudy due to chest pain or ECG changes.
Study End Points
The primary study end point was target-vessel revascularization (TVR), defined as clinically driven repeat revascularization (by symptoms or laboratory testing using PCI or bypass surgery), and a
50% stenosis within the treated vessel on follow-up angiography. The occurrence of target lesion revascularization was determined as clinically driven (
50% stenosis within 5 mm of the analysis segment associated with clinical ischemia or a
70% stenosis in the absence of clinical indicators) repeat revascularization. The primary safety end point was the occurrence of MACEs, which included a composite of death, MI, or TVR.
Statistical Analysis
Binary variables are presented as rates, and continuous variables are presented as mean±1 SD. Binary variables were compared by
2 analysis, and continuous variables were evaluated by using the Student t test. Survival analyses were performed by Kaplan-Meier methods, and survival was compared by the log-rank test. All analyses were performed with the use of SAS for Windows (versions 6.12 and 8.0, SAS Institute). A 2-sided value of P
0.05 was considered significant. The study power was sufficient to show a 38% treatment effect, assuming a 30% 8-month TVR rate in the placebo group and a 18.5% 8-month TVR rate in the treatment group, with
=0.05 and ß=0.80. This sample size was also sufficient to detect a 0.20-mm difference in the follow-up MLD between the 90Sr/90Y-treated patients and placebo-treated patients. The interaction between treatment assignment and diabetes, or use of an atherectomy device before brachytherapy, was tested by using regression models.
| Results |
|---|
|
|
|---|
|
Quantitative Angiographic Results
The distribution of target coronary vessels was similar between the 2 arms (Table 2). For both arms, the overall stented segment length was 22.7±10.7 mm, the injured segment length was 25.2±9.2 mm, the radiated segment length was 30.0±5.3 mm, and the analysis segment length was 40.8±9.4 mm. The balloon/artery ratio was 0.97 for both placebo- and 90Sr/90Y-treated patients.
|
Acute and follow-up quantitative angiographic results are found in Table 3. Angiographic complications were uncommon in both groups: a final National Heart, Lung, and Blood Institute dissection grade >B was present in 3.0% of the placebo-assigned patients and in 2.4% of the 90Sr/90Y-assigned patients. Final Thrombolysis in Myocardial Infarction (TIMI) 3 flow grade was 99.1% in the placebo arm and 100.0% in the 90Sr/90Y arm.
|
Angiographic follow-up was obtained at 8 months in 188 (81.0%) of the placebo-treated patients and in 198 (83.2%) of the 90Sr/90Y-treated patients. There was no significant difference in the follow-up reference vessel diameter between the 2 arms (2.82±0.46 mm for the 90Sr/90Y arm and 2.85± 0.44 mm for the placebo arm). Cumulative frequency distribution curves are presented for the MLD within the stent (Figure 1) and within the segment (Figure 2).
|
|
The lesion length at follow-up was significantly shorter in patients assigned to 90Sr/90Y compared with patients assigned to placebo (8.62±5.4 versus 12.5±10.7 mm, respectively; P<0.001). Asymptomatic late total occlusion was found with similar frequency between the 2 arms (4.0% in the 90Sr/90Y arm and 3.7% in the placebo arm, P=0.872). There were no new late aneurysms detected in either arm at the 8-month angiographic follow-up. Geographic miss was documented in 130 (34%) of 386 lesions available for follow-up angiographic analysis. Restenosis rates within the analysis segment in patients treated with 90Sr/90Y were similar in both groups (25.4% in patients with lesions with geographic miss and 29.4% in patients with no geographic miss). There were also no significant differences in the mean percent stenosis at the proximal or distal edges of the source train in patients treated with 90Sr/90Y or placebo.
The presence of diabetes mellitus or use of a debulking device did not influence the effect of 90Sr/90Y in reducing angiographic restenosis, as assessed by multivariable analysis. In patients who did not receive debulking therapy, the binary analysis segment restenosis rate was 38.5% in the placebo group and 27.3% in the 90Sr/90Y group (P=0.094). In patients who did receive debulking therapy, the binary analysis segment restenosis rate was 52.7% in the placebo group and 30.3% in the 90Sr/90Y group (P=0.0017). In patients without diabetes mellitus, the binary analysis segment restenosis rate was 45.3% in the placebo group and 26.9% in the 90Sr/90Y group (P=0.0019). In patients with diabetes mellitus, the binary analysis segment restenosis rate was 45.0% in the placebo group and 32.8% in the 90Sr/90Y group (P=0.164).
Early and Late Clinical Outcomes
There were no in-hospital deaths or differences in the rates of in-hospital MACEs between the 2 groups (Table 4). The procedural success (97%) and the device success (98%) rates were similar in placebo-assigned patients and 90Sr/90Y-assigned patients. Emergency CABG was performed in 1 patient assigned to 90Sr/90Y and in no patient assigned to placebo therapy. The BetaCath delivery device was successfully placed in 98.7% of the patients, and the sources were successfully delivered in 98.1% of the patients. Source drift was noted in 9% of the patients but was not associated with clinical sequelae. The temporary storage container was used in 5 patients because of the real or perceived inability to return the source train fully into the transfer device. None of these episodes was due to faulty administration according to the Nuclear Regulatory Commission criteria.
|
Late clinical outcome at 240±30-day follow-up was assessed in 439 (92.2%) of the 476 patients enrolled in the study. The primary end point, 8-month TVR, occurred significantly less frequently in patients treated with 90Sr/90Y (Table 4), with an event rate at 240 days by Kaplan-Meier estimates falling from 26.2% in placebo-treated patients to 16.5% in 90Sr/90Y-treated patients (P=0.012). According to 240-day Kaplan-Meier estimates, the rates of target lesion revascularization were reduced from 24.4% in placebo-treated patients to 13.6% in 90Sr/90Y-treated patients (P<0.001), and the Kaplan-Meier rates of MACEs were lowered from 27.8% to 18.6%, respectively (P=0.016, Figure 3).
|
There was 1 episode of late clinical stent thrombosis in the 90Sr/90Y group at 244 days. After brachytherapy in this patient, an in-stent residual stenosis was noted, and a stent was placed, resulting in a 48% residual diameter stenosis. The patient received 3 months of therapy with aspirin and clopidogrel but presented with late subacute closure at day 244.
There were 4 late deaths in the present study. One patient underwent a successful treatment followed by 90Sr/90Y therapy but died 193 days after treatment because of complications subsequent to surgical resection of a colon polyp, including pneumonia. Another patient underwent successful treatment for in-stent restenosis followed by 90Sr/90Y therapy and expired 225 days later because of a metastatic prostate and rectal cancer. A third patient underwent successful treatment for in-stent restenosis followed by 90Sr/90Y therapy and died 210 days after treatment that followed lung surgery. The fourth patient underwent successful treatment of in-stent restenosis, followed by placebo therapy. This patient died from cardiac causes 102 days after treatment.
| Discussion |
|---|
|
|
|---|
Outcomes After Stent Placement
Coronary stenting has reduced the frequency of clinical and angiographic restenosis compared with balloon angioplasty in most clinical subsets.16,22 The risk of clinical restenosis after stenting is between 10% and 30% and is increased with longer lesion or stent length,23 smaller vessel size, 24 smaller posttreatment lumen diameter, and the presence of diabetes mellitus.25 In-stent restenosis is due to excessive intimal hyperplasia within the stent and its edges.26,27 Conventional balloon angioplasty is a safe treatment for patients with stent restenosis,28 although recurrence restenosis rates after PCI for in-stent restenosis are higher than with the initial stent placement, ranging from 19% to 83%.7,8 Recurrence rates are highest when the pattern of stent restenosis is diffuse, the reference vessel is small, the patient has diabetes mellitus, or the time to recurrence is short. Debulking techniques have been used in an attempt to lower restenosis rates, but none has proven to be more effective than balloon angioplasty alone.10
Vascular Brachytherapy for Treatment of Stent Restenosis
Intracoronary 192Ir
-brachytherapy is an effective method for reducing recurrent restenosis after PCI for in-stent restenosis,1113 particularly in patients with diffuse lesions and multiple recurrent episodes of restenosis. The multicenter GAMMA-1 trial randomly assigned 252 patients to treatment with 192Ir or placebo.11 MACEs at 6 months were reduced by 36% with 192Ir (from 43.8% in placebo-treated patients to 28.2% in 192Ir-treated patients).11 Angiographic restenosis was also reduced by 41% (from 55.3% in placebo-treated patients to 32.4% in 192Ir-treated patients).11 These 192Ir trials were limited by prolonged dwell times (20 to 30 minutes), the need for extensive shielding apparatus, and the requirement for laboratory personnel to leave the room during brachytherapy administration. New stents were also commonly (>80%) used for the treatment of in-stent restenosis in these studies and resulted in frequent (5.3% to 8.3%) late stent thrombosis.11,13,14 Similar reductions in recurrence rates associated with PCI for in-stent restenosis were obtained with use of the 32P ß-source.16
Present Trial
In the present study, treatment with 90Sr/90Y after successful PCI for in-stent restenosis resulted in a 37% reduction in clinical restenosis by 240 days and a 36% reduction in angiographic restenosis. Control patients in this trial of in-stent restenosis had lower restenosis rates than did the control patients in the
-source trials. Two factors likely contributed to these differences: (1) shorter lesion lengths (control group mean lesion length in the 90Sr/90Y study was 16.0±7.6 mm versus 20.3±10.3 mm in the GAMMA-1 trial) and (2) a higher incidence of "first-time" in-stent restenosis patients in the present study.
Plaque-debulking devices, particularly rotational atherectomy, were used in nearly 50% of the patients in this trial. The use of these debulking devices did not appear to influence angiographic or clinical outcomes, and there was no diminution of the treatment effect associated with the use of debulking devices. An important feature of the present study was the infrequent (20.4%) use of additional coronary stents to treat in-stent restenosis.
Although a relationship between the occurrence of geographic miss and angiographic or clinical restenosis could not be identified, edge effect and geographic miss were not specifically evaluated in the present study. The failure to identify a relationship between geographic miss and restenosis may be due to the fact that the effective radiation length of 25 mm for the 30-mm source (accounting for the dose falloff at the edges of the radiation source) was insufficient to adequately cover the margins in most injured zones. Additional studies are needed to understand the relationship between radiation doses at the edge of the treatment zone and late restenosis.
Radiation Exposure
Compared with
-therapy, treatment with ß-radiation results in shorter treatment times (3 to 5 minutes with the use of 90Sr/90Y in the present study versus 20 to 30 minutes for 192Ir), which result in a significantly lower dose to nontarget tissue in the patient and allow the medical personnel to remain safely in the catheterization laboratory during the radiation treatment. The operator at the bedside receives
8.6x10-7 C/kg per hour for ß-radiation using 90Sr/90Y. In comparison, cardiac fluoroscopy has an exposure rate of 3.9x10-3 C/kg per hour. Accordingly, the exposure risk seen in coronary brachytherapy using 90Sr/90Y is clinically insignificant compared with the routine exposure from cardiac fluoroscopy. Differences in treatment duration, radiation exposure, and the ability to closely conform the dose to the target of interest may have important implications for the broader application of ß-radiation for the treatment of in-stent restenosis.
Late Clinical Stent Thrombosis
Prior radiation stent studies have reported that late (>30-day) clinical stent thrombosis may occur in up to 6% of patients undergoing radiation treatment. Late stent thrombosis after radiation brachytherapy is generally manifested as an acute non-Q-wave or Q-wave MI.11,13,14 The occurrence of late stent thrombosis has been attributed to delayed endothelialization over the stent struts and has been observed up to 9 to 12 months after new stent implantation.11 In the
-radiation trials, this complication has also been related to the use of a new second stent within the initial lesion.14 The relatively short-term (
4-week) dosing of antiplatelet therapy with ticlopidine or clopidogrel may have also contributed to the incidence of late thrombosis. In this trial, the 20.4% use of additional stents was reserved for bailout indications, and this lower incidence of new stent use coupled with extended dual antiplatelet therapy may have translated into a reduced rate of late stent thrombosis in the radiation arm in the present study.
Limitations of the Study
The present study did not include patients with very long lesions (stenosis lengths >30 mm) because of the relatively short (30- and 40-mm) BetaCath source trains available for the study. Longer source trains (40 and 60 mm) are now available for clinical use. It is also recognized that a lower profile delivery catheter may enhance catheter delivery in smaller vessels and in those with tortuosity, angulation, and diffuse disease, and a 3.5F catheter has now been approved for clinical use. Another limitation of the present study is the intermediate duration (240 days) of follow-up after radiation therapy. Longer angiographic and clinical follow-up (up to 2 to 3 years or more) is required to address whether stent restenosis is prevented or simply delayed.
The present study demonstrated that 90Sr/90Y ß-radiation is a safe and effective treatment for the prevention of recurrence in patients with in-stent restenosis. ß-Radiation may be used as an alternative to
-radiation in these patients. It provides the advantages of a shorter (3- to 5-minute) treatment time and allows laboratory personnel to remain at the patients bedside during the procedure. Further studies are required to evaluate the long-term duration of the effect and to determine whether other ß-sources may equally reduce recurrent restenosis after PCI for in-stent restenosis.
| Footnotes |
|---|
*A complete list of institutions and investigators participating in the START trial is listed in the Appendix. ![]()
| Appendix |
|---|
|
|
|---|
Data and Safety Monitoring Board Members
Data and Safety Monitoring Board members are as follows: Thomas Ryan (chairman), Bernard Gersh, David Faxon, John Hirshfield, Stuart Pocock (statistician), and Don Cutlip (Cardiovascular Data Analysis Center [CDAC] representative); CDAC/Harvard Clinical Research Institute Staff: Kalon Ho, William Smith (nurse reviewer), Alison Osattin, Matthew Pietrusewicz, and Lisa Beck; Angiographic Core Laboratory, Cardiology Research Foundation: Alexandra Lansky, MD; and ECG Core Laboratory, CDAC/Harvard Clinical Research Institute: Peter Zimetbaum and Shiu Ho.
Received August 23, 2001; revision received June 12, 2002; accepted June 12, 2002.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
S. G. Ellis, C. D. O'Shaughnessy, S. L. Martin, K. Kent, T. McGarry, M. A. Turco, D. J. Kereiakes, J. J. Popma, M. Friedman, J. Koglin, et al. Two-year clinical outcomes after paclitaxel-eluting stent or brachytherapy treatment for bare metal stent restenosis: the TAXUS V ISR trial Eur. Heart J., July 1, 2008; 29(13): 1625 - 1634. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Deiner, E. Shagdarsuren, P. L. Schwimmbeck, P. Rosenthal, C. Loddenkemper, U. Rauch, M. Pauschinger, R. Dietz, H.-P. Schultheiss, R. Dechend, et al. Nf-{kappa}b and AP-1 activation is associated with late lumen loss after porcine coronary angioplasty and antiproliferative beta-irradiation Cardiovasc Res, July 1, 2007; 75(1): 195 - 204. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Mauri, W.-h. Hsieh, J. M. Massaro, K. K.L. Ho, R. D'Agostino, and D. E. Cutlip Stent Thrombosis in Randomized Clinical Trials of Drug-Eluting Stents N. Engl. J. Med., March 8, 2007; 356(10): 1020 - 1029. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. J. Dzau, E. M. Antman, H. R. Black, D. L. Hayes, J. E. Manson, J. Plutzky, J. J. Popma, and W. Stevenson The Cardiovascular Disease Continuum Validated: Clinical Evidence of Improved Patient Outcomes: Part I: Pathophysiology and Clinical Trial Evidence (Risk Factors Through Stable Coronary Artery Disease) Circulation, December 19, 2006; 114(25): 2850 - 2870. [Full Text] [PDF] |
||||
![]() |
G. Weisz, M. B. Leon, D. R. Holmes Jr, D. J. Kereiakes, M. R. Clark, B. M. Cohen, S. G. Ellis, P. Coleman, C. Hill, C. Shi, et al. Two-Year Outcomes After Sirolimus-Eluting Stent Implantation: Results From the Sirolimus-Eluting Stent in de Novo Native Coronary Lesions (SIRIUS) Trial J. Am. Coll. Cardiol., April 4, 2006; 47(7): 1350 - 1355. [Abstract] [Full Text] [PDF] |
||||
![]() |
Additional Information JAMA, March 15, 2006; 295(11): E1 - E6. [Full Text] [PDF] |
||||
![]() |
G. W. Stone, S. G. Ellis, C. D. O'Shaughnessy, S. L. Martin, L. Satler, T. McGarry, M. A. Turco, D. J. Kereiakes, L. Kelley, J. J. Popma, et al. Paclitaxel-Eluting Stents vs Vascular Brachytherapy for In-Stent Restenosis Within Bare-Metal Stents: The TAXUS V ISR Randomized Trial JAMA, March 15, 2006; 295(11): 1253 - 1263. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. R. Holmes Jr, P. Teirstein, L. Satler, M. Sketch, J. O'Malley, J. J. Popma, R. E. Kuntz, P. J. Fitzgerald, H. Wang, E. Caramanica, et al. Sirolimus-Eluting Stents vs Vascular Brachytherapy for In-Stent Restenosis Within Bare-Metal Stents: The SISR Randomized Trial JAMA, March 15, 2006; 295(11): 1264 - 1273. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Mukherjee and D. J. Moliterno Brachytherapy for In-Stent Restenosis: A Distant Second Choice to Drug-Eluting Stent Placement JAMA, March 15, 2006; 295(11): 1307 - 1309. [Full Text] [PDF] |
||||
![]() |
S. C. Smith Jr, T. E. Feldman, J. W. Hirshfeld Jr, A. K. Jacobs, M. J. Kern, S. B. King III, D. A. Morrison, W. W. O'Neill, H. V. Schaff, P. L. Whitlow, et al. ACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention--Summary Article: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/SCAI Writing Committee to Update the 2001 Guidelines for Percutaneous Coronary Intervention) J. Am. Coll. Cardiol., January 3, 2006; 47(1): 216 - 235. [Full Text] [PDF] |
||||
![]() |
S. C. Smith Jr, T. E. Feldman, J. W. Hirshfeld Jr, A. K. Jacobs, M. J. Kern, S. B. King III, D. A. Morrison, W. W. O'Neill, H. V. Schaff, P. L. Whitlow, et al. ACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention--Summary Article: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/SCAI Writing Committee to Update the 2001 Guidelines for Percutaneous Coronary Intervention) Circulation, January 3, 2006; 113(1): 156 - 175. [Full Text] [PDF] |
||||
![]() |
G Sianos, A Hoye, F Saia, W van der Giessen, P Lemos, P J de Feyter, P C Levendag, R van Domburg, and P W Serruys Long term outcome after intracoronary {beta} radiation therapy Heart, July 1, 2005; 91(7): 942 - 947. [Abstract] [Full Text] [PDF] |
||||
![]() |
M R Thomas Brachytherapy: here today, gone tomorrow? Heart, June 1, 2005; 91(suppl_3): iii32 - iii34. [Full Text] [PDF] |
||||
![]() |
F.-J. Neumann, W. Desmet, E. Grube, J. Brachmann, P. Presbitero, P. Rubartelli, A. Mugge, F. Di Pede, D. Fullgraf, W. Aengevaeren, et al. Effectiveness and Safety of Sirolimus-Eluting Stents in the Treatment of Restenosis After Coronary Stent Placement Circulation, April 26, 2005; 111(16): 2107 - 2111. [Abstract] [Full Text] [PDF] |
||||
![]() |
Authors/Task Force Members, S. Silber, P. Albertsson, F. F. Aviles, P. G. Camici, A. Colombo, C. Hamm, E. Jorgensen, J. Marco, J.-E. Nordrehaug, et al. Guidelines for Percutaneous Coronary Interventions: The Task Force for Percutaneous Coronary Interventions of the European Society of Cardiology Eur. Heart J., April 2, 2005; 26(8): 804 - 847. [Full Text] [PDF] |
||||
![]() |
A. J. Lansky, J. S. Hochman, P. A. Ward, G. S. Mintz, R. Fabunmi, P. B. Berger, G. New, C. L. Grines, C. G. Pietras, M. J. Kern, et al. Percutaneous Coronary Intervention and Adjunctive Pharmacotherapy in Women: A Statement for Healthcare Professionals From the American Heart Association Circulation, February 22, 2005; 111(7): 940 - 953. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kastrati, J. Mehilli, N. von Beckerath, A. Dibra, J. Hausleiter, J. Pache, H. Schuhlen, C. Schmitt, J. Dirschinger, A. Schomig, et al. Sirolimus-Eluting Stent or Paclitaxel-Eluting Stent vs Balloon Angioplasty for Prevention of Recurrences in Patients With Coronary In-Stent Restenosis: A Randomized Controlled Trial JAMA, January 12, 2005; 293(2): 165 - 171. [Abstract] [Full Text] |