Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2004;109:2423-2427
Published online before print May 3, 2004, doi: 10.1161/01.CIR.0000129414.95137.CD
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
109/20/2423    most recent
01.CIR.0000129414.95137.CDv1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lazar, R. M.
Right arrow Articles by Naka, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lazar, R. M.
Right arrow Articles by Naka, Y.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*Heart Failure
*Stroke
Related Collections
Right arrow Health policy and outcome research
Right arrow Congestive
Right arrow CV surgery: transplantation, ventricular assistance, cardiomyopathy
Right arrow Embolic stroke

(Circulation. 2004;109:2423-2427.)
© 2004 American Heart Association, Inc.


Clinical Investigation and Reports

Neurological Events During Long-Term Mechanical Circulatory Support for Heart Failure

The Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) Experience

Ronald M. Lazar, PhD; Peter A. Shapiro, MD; Brian E. Jaski, MD; Michael K. Parides, PhD; Robert C. Bourge, MD; John T. Watson, PhD; Laura Damme, RN, MPH; Walter Dembitsky, MD; Jeffrey D. Hosenpud, MD; Lopa Gupta, RD, MPH; Anita Tierney, MPH; Tonya Kraus, RN, MSN; Yoshifumi Naka, MD

From the Departments of Neurology (R.M.L.), Psychiatry (P.A.S.), Biostatistics (M.K.P.), and Surgery (L.G., A.T., Y.N.), Columbia University College of Physicians and Surgeons, New York, NY; the Advanced Heart Failure and Cardiac Transplant Program (B.E.J., W.D.), Sharp Memorial Hospital, San Diego, Calif; the Division of Cardiovascular Disease (R.C.B.), University of Alabama at Birmingham; the Department of Bioengineering (J.T.W.), University of California San Diego; Thoratec Corp, Pleasanton, Calif (L.D.); the Organ Transplant Program (J.E.H.), St Luke’s Medical Center, Milwaukee, Wis; and Inova Fairfax Hospital, Fairfax, Va (T.K.).

Correspondence to Dr R.M. Lazar, Neurological Institute, 710 W 168th Street, New York, NY 10032. E-mail ral22{at}columbia.edu

Received October 28, 2003; revision received February 19, 2004; accepted February 25, 2004.


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Background— Progression of heart failure can lead to cardiac transplantation, but when patients are ineligible, long-term mechanical circulatory support may improve survival. The REMATCH trial showed that left ventricular assist devices (LVADs) prolonged survival in patients with end-stage disease, but with a significant number of adverse events. We report on the neurological outcomes in the REMATCH trial.

Methods and Results— We examined new neurological events in the 129 patients randomized to either LVAD placement (n=68) or medical management (n=61), classified as stroke, transient ischemic attack, toxic-metabolic encephalopathy, and other. There were 46 neurological events: 42 in 30 LVAD patients and 4 in 4 patients in the medical arm ({chi}2, 30/68 versus 4/61, P<0.001). Sixteen percent of the LVAD patients had a stroke, with a rate of 0.19 per year (95% CI, 0.10 to 0.33), many occurring in the postoperative period. The stroke rate in the medical arm was 0.052. A Kaplan-Meier survival analysis showed a 44% reduction in the risk of stroke or death in the LVAD group versus the optimal medical group (P=0.002). The mean interval from implantation to stroke was 221.8 days (±70.4 days). History of stroke, age, and sepsis were not stroke risk factors in the LVAD group.

Conclusions— Fewer than half of the patients in the LVAD group had a neurological event, and there were few neurological deaths. Survival analysis combining stroke or death demonstrated a significant benefit for long-term circulatory support with an LVAD over medical therapy. Future trials will need to address prospectively all neurological outcomes, including neurocognitive function, and the role of long-term neuroprotection.


Key Words: heart-assist device • stroke • heart failure


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
As the major indication for cardiac transplantation, heart failure affects an estimated 4.7 million Americans,1 but the shortage of donor hearts limits the availability of this treatment option.2 Ventricular assist devices (VADs) were originally used to provide mechanical circulatory support in patients awaiting planned heart transplantation. With the grave prognosis of end-stage heart failure on medical therapy and so few donor hearts at hand, the success of short-term bridge devices has led to clinical trials evaluating the suitability of VADs in patients not eligible for heart transplantation. The Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) study was the first larger-scale, randomized trial demonstrating that long-term support with a left ventricular assist device (LVAD) could result in a substantial improvement in long-term survival in this population.3

Neurological events are among the most commonly reported complications after placement of LVADs.4 Cerebral embolism is the most frequent brain event, with reports ranging from 3% to 47%, but these events occurred largely in cases in which the device was used for a limited period of time as a bridge to heart transplantation.5–9 The use of textured blood-contacting surfaces in devices may result in a lower incidence of neurological events.9,10 The patients enrolled in REMATCH, however, had more severe disease and comorbidities, were older, and remained on device support longer than patients in other randomized trials for device treatment of heart failure.11,12 Therefore, the nature and extent of neurological complications of LVAD as a destination device in this population have yet to be fully defined. REMATCH was designed to enroll 140 patients and to continue enrollment until 92 deaths had occurred, and in our initial report of the outcomes, we reported that 10% of the patients in the LVAD arm had an ischemic stroke. We review here the neurological events in REMATCH patients, including an additional 61 patient-months of experience for the medical arm and 215 patient-months for the LVAD arm beyond those reported originally.


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Patients and Procedures
As part of the REMATCH trial, 129 patients were randomized to either LVAD implantation (n=68) or optimal medical management (n=61). All participants signed institution-approved informed consent. Eligible patients for REMATCH were adults with chronic end-stage heart failure, most of whom had symptoms of NYHA class IV disease, with some later-randomized patients with class III heart failure. The primary end point was all-cause mortality; otherwise, patients were followed up for a period of 24 visits, once every 28 days (672 days), which was a joint decision between the investigators and the NHLBI Data Safety and Monitoring Board, which had oversight over the trial. The initial entry criteria for REMATCH included either NYHA class IV symptoms for >90 days despite maximal medical treatment, including ACE inhibitor, diuretic, and digoxin, and maximal oxygen consumption of <12 mL · kg–1 · min–1 or "continued need for" intravenous inotropic therapy. Inotrope dependence was initially defined as symptomatic hypotension, decreasing renal function, or worsening pulmonary congestion. It was later further defined as requiring evidence of 2 failed weaning attempts. Complete inclusion and exclusion criteria and details of IRB-approved, written informed consent are described elsewhere.3,13 Adverse events, including neurological events, were captured as secondary end points. All patients underwent administration of the NIH Stroke Scale14 at the time of study randomization in the hospital to quantify the nature and extent of previous neurological deficits, with higher scores denoting worse clinical states. A neurological event was defined as any new, temporary or permanent, focal or global neurological deficit ascertained in an examination by a neurologist using the NIH Stroke Scale and centrally adjudicated by a 5-member, independent committee of experts, which included a stroke neurologist, reporting to the National Heart, Lung, and Blood Institute of the US National Institutes of Health. Subsequently, all adjudicated neurological events were subdivided into 4 subcategories. A stroke was a focal ischemic or hemorrhagic brain event with signs and symptoms lasting >24 hours; a transient ischemic attack (TIA) was a focal ischemic brain event lasting <24 hours with a negative brain image, if one could be obtained; toxic-metabolic encephalopathy was a global change in mental status arising from organ or system failure; and other included miscellaneous conditions such as brain abscess, neurodegenerative disease, etc. Strokes and events subclassified as "other" were categorized as permanent deficits. A transient deficit consisted of the TIAs and toxic-metabolic encephalopathy because the latter was usually reversible if the underlying systemic condition was successfully treated. If a patient had a seizure judged to be caused by a toxic-metabolic disorder, then the event was considered to be in the toxic-metabolic category. Following the general principles of the REMATCH trial design, events were assigned to the LVAD or medical arm on an intent-to-treat basis.


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowReferences
 
There were 46 neurological events in this trial. Forty-two events occurred among 30 of the LVAD patients, and 4 events were documented among 4 patients in the medical management arm. Thus, patients in the LVAD arm were significantly more likely to suffer an adverse neurological event than those in the medical arm. ({chi}2, P<0.001). Figure 1 shows the distribution of these events among the LVAD patients in the 4 predefined categories: TIA, toxic-metabolic, other, and stroke. Approximately two thirds of these neurological episodes were transient, and one third were considered permanent. There were 12 strokes that occurred in 11 patients: 10 cerebral infarctions and 2 hemorrhages. Thus, 16% of all the LVAD patients had a stroke during their participation in this trial. The event rate for a permanent neurological deficit in the LVAD arm was 0.23 per patient-year (95% CI, 0.13 to 0.38), with a stroke rate of 0.19 per year (95% CI, 0.10 to 0.33). In contrast, the stroke rate in the medical management arm was 0.052. The cause of the stroke events was determined by reviewing the reports of radiographic images after strokes but not by the actual films. In the instances of nonhemorrhagic strokes, all were consistent with embolism except for border-zone infarction in one of the air emboli cases. The air emboli cases occurred because of a device failure (diaphragm rupture) and after inflow-graft repair. Four of the stroke events were adjudicated to have led to cerebrovascular death, with 2 such events occurring within the initial 30 days after LVAD implantation. None of the neurological events in the medical arm were adjudicated to have been the cause of death. Both cerebral hemorrhages in the LVAD arm were fatal. Neither of the 2 strokes in the medical management arm, 1 ischemic and 1 hemorrhagic, caused death. The "other" neurological events included focal brain infection, bilateral tremor, and new onset of dementia.



View larger version (19K):
[in this window]
[in a new window]
 
Figure 1. Relative proportion of transient and permanent neurological deficits among 68 patients in group that received LVAD.

We performed a Kaplan-Meier analysis to determine whether an end point that combined stroke or death would alter our original finding of a survival benefit to the LVAD group (Figure 2), reflecting the view that patient outcomes should include major causes of disability. There was a 44% reduction in the risk of either stroke or death in the LVAD group compared with optimal medical therapy (95% CI, 18% to 68%; P=0.002). The average follow-up time for patients in the LVAD arm was 341.3 days, and for the medical arm, 226.3 days.



View larger version (14K):
[in this window]
[in a new window]
 
Figure 2. Kaplan-Meier analysis of stroke-free survival in LVAD group and group that received optimal medical therapy (OMM). Follow-up took place for 672 days. Circles depict censored patients whose follow-up was <672 days.

Several analyses were performed to determine whether there were specific risk factors that were associated with the occurrence of stroke in the LVAD group. With regard to previous neurological events, 9 of 61 of the patients in the medical management arm had a previous stroke, ascertained as part of the medical history without need of documentation, and 8 of 68 of the patients in the LVAD group entered our study with a previous stroke. The mean baseline scores on the NIHSS, assessing previous neurological injury, were 0.46 (SD, 1.18) for the medical management group and 0.81 (SD, 1.66) for the LVAD group, which was not significantly different (t test, P=0.17). None of the 9 patients with previous stroke in the medical arm had a postrandomization neurological event. Three of the 8 LVAD patients with a previous brain infarct experienced a stroke subsequent to device implant. Unfortunately, we were unable to have the NIH Stroke Scale administered at the time of a clinical event or at future follow-up. We also could not obtain CT images for formal adjudication as to stroke subtype, arterial territory, lesion location, and infarct size. A linear logistic regression analysis showed that increasing age was not a risk factor for stroke in the LVAD group (P=0.83).

Figure 3 shows the Kaplan-Meier actuarial stroke-free curve among patients in the device group. The mean interval from implantation to stroke was 221.8 days (±70.4 days). There were 5 events within the first 30 days after implantation, but only 1 event from day 91 to day 480. Among the 68 patients who received the LVAD, there were 21 device replacements, after which 3 patients experienced a subsequent stroke. These 3 patients were stroke free from the time of the initial implantation until the replacement surgery, which was 358 days, 461 days, and 504 days, respectively. One patient had a cerebral ischemic event on the same day as implantation of the replacement LVAD. The other 2 patients had embolic strokes at 68 and 160 days, respectively, after they received the new device. There was 1 patient, randomized to the medical management arm, who crossed over to the LVAD group (implantation on day 280) and then had a stroke 112 days later. Because our analysis was based on intent to treat, his event was attributed to the original treatment assignment.



View larger version (10K):
[in this window]
[in a new window]
 
Figure 3. Kaplan-Meier analysis of time to stroke in LVAD group. Patients who died are censored.

There was no recommended antithrombotic protocol in REMATCH involving either anticoagulation or antiplatelet therapy. Decisions about such management were entirely up to the local clinical site. In the LVAD group, 49 patients were documented to be taking antiplatelet medication on at least 1 of the scheduled 30-day follow-ups, and 26 patients were on anticoagulation on at least 1 follow-up. Among the 11 patients who had a stroke in the LVAD arm, 2 were taking warfarin and an antiplatelet agent at the monthly follow-up visit before their events, 1 of whom suffered a fatal stroke from air emboli, and 5 patients were taking only antiplatelet medication.

We reported previously that sepsis was common among LVAD patients, defined as a systemic response to serious infection, usually manifested by fever, tachycardia, tachypnea, and leukocytosis, which did not have to be associated with a localized site of infection.13 Because of recent data suggesting the association of inflammation and stroke risk,15,16 we explored whether different kinds of infection predicted neurological events. There was no statistically significant relationship between the presence of sepsis, device-related (percutaneous site or pocket) infection, or non–device-related infection (eg, urinary tract, sinus infection, yeast infection) at any time and stroke.


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowReferences
 
Neurological events in REMATCH constituted a significant proportion of adverse events in patients with destination LVAD, with 44% sustaining at least 1 event and 16% having either an ischemic or hemorrhagic stroke. Approximately two thirds of these events were transient in nature (TIA or toxic metabolic), and one third were classified as permanent. The stroke rate from any cause was somewhat higher in the present analysis than the 10% reported previously,3 because we had the subsequent opportunity to follow up every patient until the earlier occurrence of either death or 672-day survival. Nevertheless, a revised survival analysis that combined stroke or death still demonstrates a significant benefit for long-term circulatory support with an LVAD over medical therapy.

All previous data on the neurological complications of LVADs have been derived from the study of patients who received temporary circulatory support as a bridge to heart transplantation. The stroke rates in these studies have been extremely variable,4,9,17–22 but these reports are difficult to compare, because most are retrospective analyses of nonstandardized, clinical examinations in which patients were implanted with different devices. The applicability of neurological outcomes of "bridge" studies to the results from REMATCH, however, may not be appropriate for several other reasons. First, none of our patients were eligible for cardiac transplantation. In addition to NYHA class IV heart failure, patients could have insulin-dependent diabetes with end-organ damage, chronic renal failure with a sustained serum creatinine of <3.5 mg/dL, or significant comorbidities such as obesity with a body mass index of not more than <40 kg/m2 or fixed pulmonary hypertension with a pulmonary vascular resistance of <8 Wood units. Whereas the mean ages for patients implanted with bridge devices have ranged from 41 to 53 years,17,20 the mean age for patients in REMATCH was >66 years. The mean duration of circulatory support in the patients receiving an LVAD as a bridge to transplantation has ranged from 18 days17 to 165 days.19 In contrast, the period of device support was much longer in REMATCH, with more than half of patients surviving >1 year on continued support.

Congestive heart failure ranks second after atrial fibrillation as a risk factor in cardiogenic stroke,23 with most strokes cardioembolic in origin.24 Our baseline data were consistent with this elevated risk, showing that 14.7% of the patients in the medical treatment arm had a stroke at some time before randomization and 11.7% of those assigned to receive the LVAD had a previous stroke. Most studies have found that previous stroke carries significant risk for recurrence.25,26 Even though patients in both treatment groups in REMATCH were at high risk for primary and secondary stroke events, those given the LVAD were much more likely to have a neurological event in general and a stroke specifically. Other risk factors for stroke, such as age and the presence of focal or systemic infection, did not show expected associations. We were unable to evaluate the potential role of atrial fibrillation, because our data collection did not separate dysrhythmia subtypes. Future research will have to determine the relative effects of cardiac surgery, the device, or the greater opportunity to have events in patients who survive longer.

There were no protocol guidelines with regard to antithrombotic therapy, in part because of concern over internal bleeding, and the previous experience with this device in the transplantation-eligible population not using anticoagulation had shown few clinically apparent, thromboembolic events (2.7%).9 Moreover, a subset of these bridge patients underwent transcranial Doppler studies of the middle cerebral arteries during LVAD support, detecting a mean of 0.52 high-intensity transient signals per 30-minute session. The patients enrolled in REMATCH, however, had more severe disease and comorbidities, were older, and most significantly, remained on device support longer than those in the bridge study. Although approximately half of the events in REMATCH occurred within the initial 30 days after implantation of either the initial or replacement device, the remaining strokes occurred from days 68 to 482. The bimodal occurrence of strokes over time in REMATCH suggests the possibility that there may be multiple pathophysiological mechanisms that might require different treatments. Unfortunately, we were unable to collect follow-up NIH Stroke Scale data or the brain images for the patients who had stroke after LVAD implantation, and so we did not have information about syndrome severity, stroke subtype, arterial territory, lesion location, and infarct size from which stroke mechanism might be inferred. Future research will need to have systematic collection of these stroke features so that we can better characterize the nature of these events. Additional research will have to determine the point after which the risk of hemorrhage is sufficiently reduced to permit safe treatment with traditional anticoagulants and whether novel approaches to anticoagulation might be suitable in the acute and postacute implantation period.10,27

Our study represents a starting point in the analysis of neurological complications in patients with long-term circulatory support for heart failure. There were only 129 patients in REMATCH, of whom 68 received the device. Although the device group clearly had more events, including stroke, the trial was not designed to have enough statistical power for analysis of specific risk factors. Our data addressed only outcomes from transplantation-ineligible patients receiving the HeartMate vented electric device (Thoratec). Future studies will determine the neurological outcomes from other devices providing long-term left ventricular assistance. Our patients were extremely sick with end-stage disease; how a younger, less sick population who might not otherwise qualify for transplantation might fare is not known. To make possible the future comparison of brain events across studies, there needs to be prospective measurement of neurological function using standardized instruments and event definitions at an appropriate baseline, at prescribed intervals, and at the time of new events. Neurological assessment also includes the specialized evaluation of neurocognitive function beyond that surveyed in instruments such as the NIH Stroke Scale, because its emphasis is primarily on motor and sensory function,28 and embolic stroke in the setting of heart failure may lead to significant cognitive loss.29,30 Moreover, neurocognitive dysfunction can occur in heart failure in the absence of clinically obvious stroke, resulting in significant disability.31 Collection of neurological events in databases such as the ISHLT Mechanical Support Device Registry32 in conjunction with prospective studies will lead to a further understanding of LVAD-associated neurological events and a reduction of their incidence.


*    Acknowledgments
 
This research was supported in part by a cooperative agreement (HL-53986) with the National Heart, Lung, and Blood Institute (NHLBI) of the National Institutes of Health and Thoratec Corporation. The event reporting, data collection, and statistical analysis were fully supported by NHLBI, with L. Damme, a full-time employee of Thoratec, not participating in the collection of adverse event data or their adjudication.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*References
 

  1. 2001 Heart and Stroke Statistical Update. Dallas, Tex: American Heart Association; 2000.
  2. Zaroff JG, Rosengard BR, Armstrong WF, et al. Consensus conference report: maximizing use of organs recovered from the cadaver donor: cardiac recommendations, March 28–29, 2001, Crystal City, Va. Circulation. 2002; 106: 836–841.[Abstract/Free Full Text]
  3. Rose EA, Gelijns AC, Moskowitz AJ, et al. Long-term mechanical left ventricular assistance for end-stage heart failure. N Engl J Med. 2001; 345: 1435–1443.[Abstract/Free Full Text]
  4. Holman WL, Bourge RC, Spruell RD, et al. Ventricular assist devices as a bridge to cardiac transplantation: a prelude to destination therapy. Ann Surg. 1997; 225: 695–704;discussion 705–706.
  5. Ashton RC Jr, Goldstein DJ, Rose EA, et al. Duration of left ventricular assist device support affects transplant survival. J Heart Lung Transplant. 1996; 15: 1151–1157.[Medline] [Order article via Infotrieve]
  6. Arabia FA, Smith RG, Rose DS, et al. Success rates of long-term circulatory assist devices used currently for bridge to heart transplantation. ASAIO J. 1996; 42: M542–M546.[Medline] [Order article via Infotrieve]
  7. Deng MC, Wilhelm M, Weyand M, et al. Long-term left ventricular assist device support: a novel pump rate challenge exercise protocol to monitor native left ventricular function. J Heart Lung Transplant. 1997; 16: 629–635.[Medline] [Order article via Infotrieve]
  8. Despotis GJ, Levine V, Joist H, et al. Multiple episodes of thrombosis with biventricular support devices with inadequate anticoagulation and evidence of accelerated intravascular coagulation. J Thorac Cardiovasc Surg. 1997; 113: 419–422.[Free Full Text]
  9. Slater JP, Rose EA, Levin HR, et al. Low thromboembolic risk without anticoagulation using advanced-design left ventricular assist devices. Ann Thorac Surg. 1996; 62: 1321–1327;discussion 1328.[Abstract/Free Full Text]
  10. Spanier T, Oz M, Levin H, et al. Activation of coagulation and fibrinolytic pathways in patients with left ventricular assist devices. J Thorac Cardiovasc Surg. 1996; 112: 1090–1097.[Abstract/Free Full Text]
  11. Packer M, Carver JR, Rodeheffer RJ, et al. Effect of oral milrinone on mortality in severe chronic heart failure. The PROMISE Study Research Group. N Engl J Med. 1991; 325: 1468–1475.[Abstract]
  12. Packer M, Coats AJ, Fowler MB, et al. Effect of carvedilol on survival in severe chronic heart failure. N Engl J Med. 2001; 344: 1651–1658.[Abstract/Free Full Text]
  13. Rose EA, Moskowitz AJ, Packer M, et al. The REMATCH trial: rationale, design, and end points. Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure. Ann Thorac Surg. 1999; 67: 723–730.[Abstract/Free Full Text]
  14. Goldstein LB, Bertels C, Davis JN. Interrater reliability of the NIH stroke scale. Arch Neurol. 1989; 46: 660–662.[Abstract]
  15. Elkind MS, Cheng J, Boden-Albala B, et al. Tumor necrosis factor receptor levels are associated with carotid atherosclerosis. Stroke. 2002; 33: 31–37.[Abstract/Free Full Text]
  16. Ross R. Atherosclerosis: an inflammatory disease. N Engl J Med. 1999; 340: 115–126.[Free Full Text]
  17. Quaini E, Pavie A, Chieco S, et al. The Concerted Action "Heart" European registry on clinical application of mechanical circulatory support systems: bridge to transplant. The Registry Scientific Committee. Eur J Cardiothorac Surg. 1997; 11: 182–188.[Abstract]
  18. Schmid C, Weyand M, Nabavi DG, et al. Cerebral and systemic embolization during left ventricular support with the Novacor N100 device. Ann Thorac Surg. 1998; 65: 1703–1710.[Abstract/Free Full Text]
  19. Koul B, Solem JO, Steen S, et al. HeartMate left ventricular assist device as bridge to heart transplantation. Ann Thorac Surg. 1998; 65: 1625–1630.[Abstract/Free Full Text]
  20. McCarthy PM, Smedira NO, Vargo RL, et al. One hundred patients with the HeartMate left ventricular assist device: evolving concepts and technology. J Thorac Cardiovasc Surg. 1998; 115: 904–912.[Abstract/Free Full Text]
  21. Reilly MP, Wiegers SE, Cucchiara AJ, et al. Frequency, risk factors, and clinical outcomes of left ventricular assist device–associated ventricular thrombus. Am J Cardiol. 2000; 86: 1156–1159, A10.
  22. Thomas CE, Jichici D, Petrucci R, et al. Neurologic complications of the Novacor left ventricular assist device. Ann Thorac Surg. 2001; 72: 1311–1315.[Abstract/Free Full Text]
  23. Kannel WB, Wolf PA, Verter J. Manifestations of coronary disease predisposing to stroke. The Framingham study. JAMA. 1983; 250: 2942–2946.[Abstract]
  24. Pullicino PM, Halperin JL, Thompson JL. Stroke in patients with heart failure and reduced left ventricular ejection fraction. Neurology. 2000; 54: 288–294.[Abstract/Free Full Text]
  25. Sacco RL, Shi T, Zamanillo MC, et al. Predictors of mortality and recurrence after hospitalized cerebral infarction in an urban community: the Northern Manhattan Stroke Study. Neurology. 1994; 44: 626–634.[Abstract/Free Full Text]
  26. Prencipe M, Culasso F, Rasura M, et al. Long-term prognosis after a minor stroke: 10-year mortality and major stroke recurrence rates in a hospital-based cohort. Stroke. 1998; 29: 126–132.[Abstract/Free Full Text]
  27. Spanier TB, Chen JM, Oz MC, et al. Time-dependent cellular population of textured-surface left ventricular assist devices contributes to the development of a biphasic systemic procoagulant response. J Thorac Cardiovasc Surg. 1999; 118: 404–413.[Abstract/Free Full Text]
  28. Mohr JP. Acute clinical trials: an expression of concern. Cerebrovasc Dis. 1999; 9 (suppl 3): 45–50.[Medline] [Order article via Infotrieve]
  29. Roman GC. Vascular dementia may be the most common form of dementia in the elderly. J Neurol Sci. 2002; 203–204: 7–10.
  30. Pullicino PM, Hart J. Cognitive impairment in congestive heart failure? Embolism vs hypoperfusion. Neurology. 2001; 57: 1945–1946.[Free Full Text]
  31. Zuccala G, Onder G, Pedone C, et al. Cognitive dysfunction as a major determinant of disability in patients with heart failure: results from a multicentre survey. On behalf of the GIFA (SIGG-ONLUS) Investigators. J Neurol Neurosurg Psychiatry. 2001; 70: 109–112.[Abstract/Free Full Text]
  32. International SoHLT. Heart/Lung Registries. Available at: http://www.ishlt.org/registries./ Accessed April 22, 2004.



This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. W. Long, A. H. Healy, B. Y. Rasmusson, C. G. Cowley, K. E. Nelson, A. G. Kfoury, S. E. Clayson, B. B. Reid, S. A. Moore, D. U. Blank, et al.
Improving outcomes with long-term "destination" therapy using left ventricular assist devices.
J. Thorac. Cardiovasc. Surg., June 1, 2008; 135(6): 1353 - 1361.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. G. Rogers, J. Butler, S. L. Lansman, A. Gass, P. M. Portner, M. K. Pasque, R. N. Pierson III, and for the INTrEPID Investigators
Chronic Mechanical Circulatory Support for Inotrope-Dependent Heart Failure Patients Who Are Not Transplant Candidates: Results of the INTrEPID Trial
J. Am. Coll. Cardiol., August 21, 2007; 50(8): 741 - 747.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
H. Tsukui, A. Abla, J. J. Teuteberg, D. M. McNamara, M. A. Mathier, L. M. Cadaret, and R. L. Kormos
Cerebrovascular accidents in patients with a ventricular assist device
J. Thorac. Cardiovasc. Surg., July 1, 2007; 134(1): 114 - 123.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
B. L. Steenwyk, J. K. Kirklin, W. Q. Gurley, and V. G. Nielsen
The Hemostatic History of a 15-Month-Old Child Implanted with a Berlin Heart Left Ventricular Assist Device
Anesth. Analg., March 1, 2007; 104(3): 538 - 540.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
L. W. Stevenson and P. Shekar
Ventricular Assist Devices for Durable Support
Circulation, August 30, 2005; 112(9): e111 - e115.
[Full Text] [PDF]


Home page
Evid. Based Med.Home page
Other articles noted
Evid. Based Med., September 1, 2004; 9(5): e5 - e5.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
109/20/2423    most recent
01.CIR.0000129414.95137.CDv1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lazar, R. M.
Right arrow Articles by Naka, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lazar, R. M.
Right arrow Articles by Naka, Y.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*Heart Failure
*Stroke
Related Collections
Right arrow Health policy and outcome research
Right arrow Congestive
Right arrow CV surgery: transplantation, ventricular assistance, cardiomyopathy
Right arrow Embolic stroke