Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2004;109:756-762
doi: 10.1161/01.CIR.0000112571.06979.B2
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Siebes, M.
Right arrow Articles by Piek, J. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Siebes, M.
Right arrow Articles by Piek, J. J.
Related Collections
Right arrow Pathophysiology
Right arrow Catheter-based coronary interventions: stents
Right arrow Coronary imaging: angiography/ultrasound/Doppler/CC
Right arrow Coronary circulation

(Circulation. 2004;109:756-762.)
© 2004 American Heart Association, Inc.


Clinical Investigation and Reports

Single-Wire Pressure and Flow Velocity Measurement to Quantify Coronary Stenosis Hemodynamics and Effects of Percutaneous Interventions

Maria Siebes, PhD; Bart-Jan Verhoeff, MSc; Martijn Meuwissen, MD; Robbert J. de Winter, MD; Jos A.E. Spaan, PhD; Jan J. Piek, MD

From the Departments of Cardiology (M.S., B.-J.V., M.M., R.J.d.W., J.J.P.) and Medical Physics (M.S., J.A.E.S.), Academic Medical Center, Amsterdam, The Netherlands.

Reprint requests to Dr Maria Siebes, PhD, Department of Medical Physics, Academic Medical Center, Meibergdreef 9, PO Box 22700, 1105 AZ Amsterdam, The Netherlands. E-mail m.siebes{at}amc.uva.nl

Received December 30, 2002; de novo received August 18, 2003; revision received October 30, 2003; accepted October 31, 2003.


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Background— Lack of high-fidelity simultaneous measurements of pressure and flow velocity distal to a coronary artery stenosis has hampered the study of stenosis pressure drop–velocity ({Delta}P-v) relationships in patients.

Methods and Results— A novel 0.014-inch dual-sensor (pressure and Doppler velocity) guidewire was used in 15 coronary lesions to obtain per-beat averages of pressure drop and velocity after an intracoronary bolus of adenosine. {Delta}P-v relations from resting to maximal hyperemic velocity were constructed before and after stepwise executed percutaneous coronary intervention (PCI). Before PCI, half of the {Delta}P-v relations revealed the presence of a compliant stenosis, which was stabilized by angioplasty. Fractional flow reserve (FFR), coronary flow reserve (CFVR), and velocity-based indices of stenosis resistance (h-SRv) and microvascular resistance (h-MRv) at maximal hyperemia were compared. Stepwise PCI significantly lowered h-SRv, with an initial marked reduction in hyperemic pressure drop followed by further gains in velocity. A concomitant significant reduction of h-MRv accounted for half of the gain in velocity after PCI. The average magnitude of absolute incremental hemodynamic changes was highest for h-SRv (56.8±39.2%) compared with CFVR (35.3±34.5%, P<0.005) or FFR (19.5±25.2%, P<0.0001).

Conclusions— {Delta}P-v relations comprehensively visualize improvements in coronary hemodynamics after PCI. h-SRv is a powerful and sensitive descriptor of the functional gain achieved by PCI, combining information about both pressure gradient and velocity, which are oppositely affected by PCI. Simultaneous assessment of stenosis and microvascular resistance may provide a valuable tool for guidance of PCI.


Key Words: coronary disease • hemodynamics • stenosis • angioplasty • microcirculation


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Both pressure-derived myocardial fractional flow reserve (FFR) and coronary flow velocity reserve (CFVR) have been evaluated as powerful predictors of inducible ischemia, as measured by noninvasive stress tests, and of adverse events after stent placement.1,2 However, as the underlying models of these traditional indices demonstrate, their values depend not only on stenosis resistance but also on microvascular resistance at full dilation, which may vary as a result of heart rate, metabolic demand, or microvascular disease3–5 and which affects FFR and CFVR in opposite directions.6,7 The combination of pressure and flow velocity into an index of hyperemic stenosis resistance significantly improved diagnostic accuracy as assessed by noninvasive ischemic testing,8 especially in cases with discordant outcomes between the traditional parameters.6

The relationship between distal coronary velocity and transstenotic pressure gradient is almost entirely determined by the coronary stenosis and is thus by definition well suited to evaluate its hemodynamic severity.9,10 Diastolic pressure gradient–velocity ({Delta}P-v) relationships have been obtained in humans with 2 single-sensor–equipped guidewires.11–13 Recently, the simultaneous measurement of phasic distal pressure and velocity by a single dual-sensor–equipped guidewire has become possible.

In the present study, we report on the first group of patients in whom this novel device was used to quantify changes in stenosis hemodynamics and its alterations due to stepwise executed percutaneous coronary intervention (PCI) by the assessment of complete {Delta}P-v curves obtained from per-beat averages throughout the response to a vasodilator stimulus. We hypothesized that evaluation of stenosis hemodynamics and effects of PCI benefits from combined distal pressure and velocity measurements, because they reveal information not attainable with single-variable measurements and uncover mechanisms of action on the epicardial (stenosis) and microvascular compartments of the coronary circulation through quantitative assessment of the functional gain after PCI in terms of stenosis and microvascular resistance.


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Patient Population
The study population consisted of 19 patients (15 males, mean age 56±8 years) with stable angina pectoris scheduled for elective PTCA. Exclusion criteria were diffuse or 3-vessel disease, significant left main coronary artery stenosis, or a subtotal lesion in the target vessel; recent myocardial infarction (<6 weeks); prior cardiac surgery; or hypertrophic cardiomyopathy. The procedures were in accordance with institutional guidelines. All patients gave written informed consent, and the institutional Medical Ethics Committee approved the study protocol.

Cardiac Catheterization Procedure
All antianginal and antiplatelet medication was continued until cardiac catheterization. After oral administration of lorazepam (1 mg), cardiac catheterization was performed by percutaneous femoral approach. All patients received a bolus of heparin (7500 IU IV) at the beginning of the procedure. Additional heparin was administered if the procedure lasted more than 90 minutes. Nitroglycerin (0.1 mg IC) was given before coronary angiography and every 30 minutes throughout the procedure.

Hemodynamic Measurements
Aortic pressure was measured through a 5F or 6F guiding catheter. In an angiographically normal reference vessel and distal to the stenosis in the target vessel, intracoronary pressure and flow velocity were measured with a novel 0.014-inch-diameter guidewire (JOMED Inc; now Volcano Therapeutics Inc) that combines a standard Doppler sensor at the tip and a standard pressure sensor 3 cm proximal to the tip (Figure 1). The signals were processed by standard hardware (FloMap and WaveMap, JOMED Inc; now Volcano Therapeutics, Inc). Benchtop testing before the patient study verified high-quality measurements similar to those of established single-sensor guidewires. The position of the Doppler sensor was manipulated until an optimal and stable blood flow velocity signal was obtained distal to the lesion. The sensors were positioned at the same location for all measurements obtained throughout the procedure. Aortic pressure (Pa), coronary pressure (Pd) and instantaneous peak velocity (v) distal to the stenosis, and the ECG were recorded on a personal computer after 12-bit analog-to-digital conversion at 120 Hz. All signals were continuously recorded at rest and throughout induction and decline of maximum hyperemia after an intracoronary bolus of 20 to 40 µg of adenosine.14



View larger version (52K):
[in this window]
[in a new window]
 
Figure 1. Dual-sensor guidewire (JOMED Inc; now Volcano Therapeutics Inc).

Protocol
After baseline hemodynamic measurements were taken in an angiographically normal reference vessel and in the target vessel, all patients underwent balloon angioplasty, with the balloon size based on angiographic dimensions, followed by placement of a single slotted-tube stent. The stent was upsized according to the CLOUT (Clinical Outcomes with Ultrasound Trial) criteria by intravascular ultrasound guidance.15 Immediately after PTCA and stent placement, hemodynamic and angiographic recordings were obtained.

Coronary Angiography
Coronary angiograms were obtained before and after each step of the percutaneous intervention. Several views were obtained before PCI, and the one that showed the most severe stenosis without overlap or foreshortening was maintained for comparison with the posttreatment situation. Biplane views were obtained when possible, and the results were averaged.

Data Analysis
Percent diameter stenosis, reference diameter, and minimal lumen diameter were obtained by quantitative analysis of the coronary angiograms with a validated computer-assisted analysis system (QCA-CMS version 5.0, MEDIS). For each heart cycle throughout the complete hyperemic response to administration of adenosine, the per-beat average of stenosis pressure gradient (in mm Hg; {Delta}P=Pa-Pd) was plotted versus the mean flow velocity v (in cm/s). These data were fitted with the equation describing the underlying fluid dynamic model,9,10Down


Parameters of functional stenosis severity were calculated as myocardial FFR (Pd/Pa), CFVR (vhyp/vbaseline), relative CFVR (CFVRtarget/CFVRreference), and velocity-based indices of stenosis resistance (h-SRv={Delta}P/v) and distal microvascular resistance (h-MRv=Pd/v) at maximal hyperemia.6 Because stenosis resistance is flow dependent,8,16 it should be determined at maximum hyperemia. Signed and unsigned (absolute) incremental changes in these parameters were compared per PCI step.

The separate contribution of changes in each of these 2 resistance indices to the velocity gain achieved by PCI was assessed with a lumped model of 2 resistancs in series representing the coronary circulation. With venous pressure assumed to be zero and the vessel diameter at the site of measurement constant, velocity can be expressed asDown


By substituting the hyperemic MRv measured before PCI (MRvpre), the relative gain in velocity exclusively due to a decrease in h-SRv after each PCI step was then calculated with the maximal hyperemic velocity achieved after PCI (vSRv) asDown


Statistical Analysis
Continuous variables were expressed as mean±SD and compared by paired Student’s t test or ANOVA with repeated measures followed by contrast analysis as appropriate (SPSS version 11.5). Reproducibility of hyperemic measurements before PCI was assessed by coefficient of variation, calculated as the square root of the within-subject variance component obtained with the use of a 1-way random-effect model ANOVA divided by the group mean. Values of P<0.05 were considered statistically significant.


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowReferences
 
Clinical and Angiographic Characteristics
The protocol could not be completed in 5 patients (in 3 because of initial technical problems related to drift or electromagnetic interference between the 2 sensors and in 2 for clinical reasons). The clinical profile of the remaining 14 patients is summarized in Table 1. Most patients had moderate to severe anginal complaints (72% Canadian Cardiovascular Society [CCS] class 3, 14% CCS class 2, and 14% CCS class 1). In 3 patients, direct stenting needed to be performed without hemodynamic measurements after balloon angioplasty. These patients are included in the "balloon" group for stepwise comparison. In 2 patients, the reference vessel was not instrumented for clinical reasons. One patient required 2 stents in the same vessel in different procedures. Hemodynamic baseline characteristics of the treated lesions (11 left anterior descending coronary arteries, 2 right coronary arteries, 1 left circumflex artery, and 1 marginal branch) and reference vessels (2 left anterior descending coronary arteries, 9 left circumflex arteries, and 2 marginal branches) are listed in Table 2.


View this table:
[in this window]
[in a new window]
 
TABLE 1. Patient Clinical Characteristics


View this table:
[in this window]
[in a new window]
 
TABLE 2. Hemodynamic Characteristics of the Stenoses

Balloon angioplasty and stent implantation reduced diameter stenosis from 52.2±8.6% (range 33.3% to 65.5%) to 2.5±8.9% (range -14.6% to 19.3%). Minimum stenosis diameter increased from 1.33±0.30 to 3.33±0.48 mm. Average diameter stenosis in the reference vessels was 24.3±8.8%.

Hemodynamic Data
Reproducibility of repeated hyperemic measurements obtained in the reference vessel and in the target vessel before PCI (n=46) was excellent. The coefficient of variation was 6.4% for velocity, 3.2% for aortic pressure, and 3.5% for distal pressure. Corresponding values for derived data were 5.7% for h-{Delta}P, 4.6% for h-SRv, and 6.2% for h-MRv.

A typical example of phasic signals is shown in Figure 2. The left panel was obtained before treatment and shows that injection of adenosine caused a transient decrease in MRv, accompanied by only a small increase in flow velocity and a marked drop in distal pressure. These characteristics improved after completion of PCI, as shown in the right panel.



View larger version (68K):
[in this window]
[in a new window]
 
Figure 2. Hemodynamic tracings before (left) and after (right) intervention. Arrows indicate adenosine injection.

Figure 3 illustrates PCI-induced hemodynamic changes in terms of {Delta}P-v relations obtained in 1 patient before treatment and after balloon angioplasty, stenting, and upsized stenting. Each data point represents the average over 1 beat, from baseline in the lower left to maximal hyperemia at the upper right of each curve. These curves provide a comprehensive overview of the progressive hemodynamic improvement achieved by stepwise PCI. With reduction in stenosis severity by PCI, the relationships became less steep, and maximal flow velocity increased, thereby approaching the {Delta}P-v relation of the reference vessel.



View larger version (25K):
[in this window]
[in a new window]
 
Figure 3. Pressure drop–velocity relationships obtained before (pre) and after successive treatment steps in 1 patient. UPstent indicates upsized stent; arrows indicate maximum flow achievable if microvascular resistance had remained at pretreatment level.

Before treatment, 7 of the 15 lesions exhibited a "looped" {Delta}P-v relation, which disappeared after PTCA or stenting (Figure 4). This hysteresis-like behavior is characteristic for a compliant, often flow-limiting lesion (ie, a lesion in which further reduction in downstream resistance will not increase flow). This special hemodynamic behavior was not obvious from the continuous pressure and flow-velocity tracings obtained during catheterization, nor could it be discerned from angiographic, clinical, or descriptive hemodynamic parameters.



View larger version (24K):
[in this window]
[in a new window]
 
Figure 4. Example of pressure drop–velocity relationship demonstrating a loop before treatment (pre), which indicates a compliant stenosis. Arrows indicate maximum flow achievable if microvascular resistance had remained at pretreatment level.

Figure 5 illustrates that the initial PCI step (balloon angioplasty) caused a significant decrease in hyperemic pressure gradient (P<0.005) followed by progressively smaller changes for further treatment steps (stenting and upsized stenting). In contrast, maximal velocity continued to increase significantly (P<0.025), with both signals approaching the values obtained in the reference vessel. The relative unsigned incremental change in h-SRv averaged over all PCI steps was therefore significantly higher than that of FFR (P<0.0001), CFVR (P<0.01), or relative CFVR (P<0.005), as shown in Figure 6.



View larger version (18K):
[in this window]
[in a new window]
 
Figure 5. Average hyperemic pressure gradient (h-{Delta}P) and distal velocity (h-v). *P<0.02 vs previous step, {dagger}P<0.05 vs upsized stent. pre indicates before treatment; Upstent, upsized stent; and Ref, reference.



View larger version (14K):
[in this window]
[in a new window]
 
Figure 6. Average unsigned incremental (Incr.) changes in hemodynamic parameters. Minus sign indicates actual direction of changes was negative for h-SRv and h-MRv. *P<0.005. rCFVR indicates relative CFVR.

Heart rate did not change. In addition to the expected increase in FFR and CFVR and the anticipated large decrease in h-SRv compared with pretreatment values (Table 2), there was a significant reduction in h-MRv after PCI (P<0.005). The vertical arrows in Figures 3 and 4Up indicate the calculated maximally achievable hyperemic flow velocity (Equation 3) if h-MRv had remained unchanged at the pretreatment level. Averaged over all steps, the relative contribution of the decrease in h-SRv and h-MRv to the gain in maximal velocity after PCI was approximately equal (52.4±63.6% versus 47.6±63.6%, P=0.82).


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowReferences
 
We assessed the effect of PCI on stenosis and coronary microvascular hemodynamics in terms of {Delta}P-v relations obtained throughout the hyperemic response to adenosine. PCI-induced changes in stenosis geometry resulted in characteristic hemodynamic changes that were comprehensively visualized by {Delta}P-v relations. Compared with traditional measures of functional stenosis severity such as FFR, CFVR, and relative CFVR, a velocity-based index of stenosis resistance during maximal hyperemia (h-SRv) was the most sensitive hemodynamic measure of PCI-induced improvements in stenosis severity, by combining opposite changes in {Delta}P and velocity. A concomitant decrease in microvascular resistance (h-MRv) accounted for approximately half of the increase in maximal flow velocity after PCI.

Interpretation of the Pressure-Gradient–Flow-Velocity Relationship
The hemodynamic behavior of an arterial stenosis is uniquely characterized by its pressure drop–velocity relation, a concept put forward by Young9 and extensively validated by in vitro and in vivo studies.10,17,18 For a given coronary stenosis, {Delta}P-v relations start at resting values of {Delta}P and v and increase curvilinear to hyperemic values in response to microvascular dilation after adenosine injection. Alterations in stenosis geometry (eg, by PCI) will result in a different curve. The composite of curves thus obtained per patient after stepwise PCI provides a clear and comprehensive overview of the hemodynamic improvement in both stenosis and distal coronary hemodynamics achieved by the interventions.

Instantaneous {Delta}P-v relationships obtained in artificially created coronary artery stenoses in dogs were first reported by Gould18 for the diastolic part of the cardiac cycle. Fifteen years later, the first {Delta}P-v relationships of coronary stenoses in humans were obtained after placement of both a pressure and Doppler guidewire distal to the lesion.11,12 Marques and coworkers13 demonstrated the feasibility and reproducibility of this diastolic relationship and its ability to discriminate between normal and diseased coronary arteries.

We used a single dual-sensor–equipped wire, thereby minimizing potential overestimation of stenosis severity, especially before treatment.19 In addition, instead of diastolic portions of selected cycles during the hyperemic response, we used successive per-beat averages to generate the pressure-drop–flow relationship of a coronary stenosis from baseline throughout maximal hyperemia.10,17 The main advantages are easier postprocessing with less user interaction, which circumvents problems related to phase delays between the pressure transducers, the characterization of stenosis hemodynamics over the entire range of possible flow velocities, and the ability to identify partially compliant lesions. The present results support previous findings that coronary flow can be considered as quasi-steady,10,17 because the mean pressure drop–velocity data were nicely fit with the quadratic equation when a fixed stenosis was present. Rapid changes in the flow waveform are confined to brief periods during the cardiac cycle, and flow pulsatility declines with increasing stenosis severity, thus only minimally affecting means of pressure and flow.

Flow-mediated dilation of the normal reference diameter can worsen stenosis severity, which results in an upward shift of the instantaneous diastolic {Delta}P-v relation between baseline and maximal hyperemia.20 However, patients in the present study received intracoronary nitroglycerin every 30 minutes throughout the procedure to vasodilate the epicardial vessels before hyperemia was induced. In contrast, coronary artery stenoses are frequently at least partially compliant, and stenosis dimensions then depend on intrastenotic pressure.16,21–24 As intrastenotic pressure falls with increasing flow during the hyperemic response, the stenosis becomes more severe, which results in a deviation from the quadratic {Delta}P-v relation. Although we did not obtain angiograms during maximal hyperemia to document possible changes in stenosis dimensions, this explanation can be inferred from the nature of the pressure drop–flow relationship of partially compliant stenoses.25,26 In severe cases, the stenosis may behave as a Starling resistor, where flow becomes disassociated from the pressure gradient.24

At minimum MRv after adenosine injection, partial collapse of a compliant stenosis produces maximal pressure gradient at submaximal flow. Flow reaches a maximum at a considerably lower pressure gradient (dashed lines in Figure 4). This behavior represents an additional mechanism for the existence of discordant measurements between FFR and CFVR at the epicardial level, besides the role of h-MRv.6,7 The frequent occurrence of this phenomenon in the patient group in the present study suggests that stenosis compliance may be a contributing factor to anginal complaints, especially during periods of low microvascular resistance.

Changes in Hemodynamic Parameters by PCI
Quantitative analysis of the data obtained at rest and during maximal hyperemia revealed h-SRv to be a powerful and sensitive indicator of the functional gain achieved after PCI. Generally, a large initial decline in pressure gradient was followed by further gains in hyperemic flow velocity with treatment. The combination of pressure gradient and flow velocity is therefore well suited to assess changes in hemodynamic stenosis severity and avoids pitfalls due to variations in baseline velocity affecting CFVR,27 the declining sensitivity of pressure-based methods (FFR) with improvement in stenosis geometry, or nonmaximal hyperemia (CFVR and FFR).3

The simultaneous assessment of distal pressure and flow velocity furthermore permits the separate assessment of changes in both the proximal epicardial and distal myocardial resistance index with PCI. The initial results obtained in the present study indicate that flow restoration after PCI is not only due to the primary effect of treating the epicardial lesion but also to a significant accessory reduction in hyperemic microvascular resistance. Additional studies should be performed in a larger patient group to elucidate this phenomenon, which has been described previously.28

Methodological Considerations
Current prototypes of the dual-sensor guidewire were designed with a distance of 3 cm between the Doppler flow sensor at the tip and the pressure sensor. Ideally, pressure and velocity should be measured at the same location to avoid time delays between the signals. However, this is only relevant for the instantaneous (diastolic) {Delta}P-v relation and not for relationships between means as in the present study. Another disadvantage of this design is the inability to measure between lesions that are <3 cm apart. Future designs could result in a more practical compromise between sensor distance and wire-tip flexibility.

The use of velocity-based parameters is potentially limited by their diameter dependence and thus by the axial position of the Doppler sensor and possible diameter variations at that location. However, velocity normalizes flow for differences in coronary arterial diameter due to branching and is preserved between proximal and distal segments.29 An increase in distal diameter due to pressure restoration after PCI attenuates the rise in hyperemic velocity that would be seen if vessel diameters remained at pre-PCI levels. Hence, the observed decrease in the velocity-based resistance indices after PCI may have been underestimated compared with the pre-PCI situation. Although the principles of stenosis {Delta}P-v relationships to assess the presence of a compliant stenosis and treatment success have been established in the present study, the small sample size limits extension of our quantitative findings to a larger patient group.

Clinical Implications
Combined measurement of distal pressure and flow velocity, made possible by recent advancements in wire fabrication technology, not only yields a high diagnostic accuracy8 but also holds great potential for improved guidance of coronary interventions in the catheterization laboratory. The {Delta}P-v relationship does not depend on the level of vasodilation achieved by adenosine but only on the severity of the stenosis. It can identify compliant lesions, the severity of which changes as a function of intrastenotic pressure, which may be an additional mechanism responsible for anginal complaints. The frequent occurrence of this phenomenon illustrates potential pitfalls in the analysis of coronary hemodynamics based on traditional hemodynamic parameters. The effect of interventions on the hemodynamics of the stenosed artery and distal microcirculation can be separately quantified, thereby providing insight into mechanisms for nonoptimized FFR or CFVR after PCI that have been associated with a worse outcome.1,2 Further studies are needed to establish the potential prognostic value of h-SRv and h-MRv after coronary interventions.


*    Acknowledgments
 
This study was funded in part by the Netherlands Heart Foundation (grant 2000.090). The authors thank the clinical and nursing staff of the catheterization laboratory. The skillful wire photography by Cees Hersbach is gratefully appreciated.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*References
 
1. Voskuil M, van Liebergen RAM, Albertal M, et al. Coronary hemodynamics of stent implantation after suboptimal and optimal balloon angioplasty. J Am Coll Cardiol. 2002; 39: 1513–1517.[Abstract/Free Full Text]

2. Pijls NHJ, Klauss V, Siebert U, et al. Coronary pressure measurement after stenting predicts adverse events at follow-up: a multicenter registry. Circulation. 2002; 105: 2950–2954.[Abstract/Free Full Text]

3. Hoffman JIE. Problems of coronary flow reserve. Ann Biomed Eng. 2000; 28: 884–896.[CrossRef][Medline] [Order article via Infotrieve]

4. Sambuceti G, Marzilli M, Fedele S, et al. Paradoxical increase in microvascular resistance during tachycardia downstream from a severe stenosis in patients with coronary artery disease: reversal by angioplasty. Circulation. 2001; 103: 2352–2345.[Abstract/Free Full Text]

5. Siebes M, Chamuleau SAJ, Meuwissen M, et al. Influence of hemodynamic conditions on fractional flow reserve: parametric analysis of underlying model. Am J Physiol Heart Circ Physiol. 2002; 283: H1462–H1470.[Abstract/Free Full Text]

6. Meuwissen M, Chamuleau SAJ, Siebes M, et al. Role of variability in microvascular resistance on fractional flow reserve and coronary blood flow velocity reserve in intermediate coronary lesions. Circulation. 2001; 103: 184–187.[Abstract/Free Full Text]

7. Meuwissen M, Siebes M, Spaan JAE, et al. Rationale of combined intracoronary pressure and flow velocity measurements. Z Kardiol. 2002; 91: III/108–III/112.

8. Meuwissen M, Siebes M, Chamuleau SAJ, et al. Hyperemic stenosis resistance index for evaluation of functional coronary lesion severity. Circulation. 2002; 106: 441–446.[Abstract/Free Full Text]

9. Young DF. Fluid mechanics of arterial stenoses. J Biomech Eng. 1979; 101: 157–175.

10. Gould KL. Quantification of coronary artery stenosis in vivo. Circ Res. 1985; 57: 341–353.[Free Full Text]

11. Serruys PW, Di Mario C, Meneveau N, et al. Intracoronary pressure and flow velocity with sensor-tip guidewires: a new methodologic approach for assessment of coronary hemodynamics before and after coronary interventions. Am J Cardiol. 1993; 71: 41D–53D.[CrossRef][Medline] [Order article via Infotrieve]

12. Di Mario C, Gil R, de Feyter PJ, et al. Utilization of translesional hemodynamics: comparison of pressure and flow methods in stenosis assessment in patients with coronary artery disease. Cathet Cardiovasc Diagn. 1996; 38: 189–201.[CrossRef][Medline] [Order article via Infotrieve]

13. Marques KMJ, Spruijt HJ, Boer C, et al. The diastolic flow-pressure gradient relation in coronary stenoses in humans. J Am Coll Cardiol. 2002; 39: 1630–1636.[Abstract/Free Full Text]

14. De Bruyne B, Pijls NHJ, Barbato E, et al. Intracoronary and intravenous adenosine 5'-triphosphate, adenosine, papaverine, and contrast medium to assess fractional flow reserve in humans. Circulation. 2003; 107: 1877–1883.[Abstract/Free Full Text]

15. Stone GW, Hodgson JM, St Goar FG, et al. Improved procedural results of coronary angioplasty with intravascular ultrasound-guided balloon sizing: the CLOUT pilot trial: Clinical Outcomes with Ultrasound Trial (CLOUT) Investigators. Circulation. 1997; 95: 2044–2052.[Abstract/Free Full Text]

16. Logan SE. On the fluid mechanics of human coronary artery stenosis. IEEE Trans Biomed Eng. 1975; 22: 327–334.[Medline] [Order article via Infotrieve]

17. Young DF, Cholvin NR, Kirkeeide RL, et al. Hemodynamics of arterial stenoses at elevated flow rates. Circ Res. 1977; 41: 99–107.[Abstract/Free Full Text]

18. Gould KL. Pressure-flow characteristics of coronary stenoses in unsedated dogs at rest and during coronary vasodilation. Circ Res. 1978; 43: 242–253.[Abstract/Free Full Text]

19. Back LH, Kwack EY, Back MR. Flow rate-pressure drop relation in coronary angioplasty: catheter obstruction effect. J Biomech Eng. 1996; 118: 83–89.[Medline] [Order article via Infotrieve]

20. Gould KL, Kelley KO. Physiological significance of coronary flow velocity and changing stenosis geometry during coronary vasodilation in awake dogs. Circ Res. 1982; 50: 695–704.[Free Full Text]

21. Saner HE, Gobel FL, Salomonowitz E, et al. The disease-free wall in coronary atherosclerosis: its relation to degree of obstruction. J Am Coll Cardiol. 1985; 6: 1096–1099.[Abstract]

22. Schwartz JS, Carlyle PF, Cohn JN. Effect of coronary arterial pressure on coronary stenosis resistance. Circulation. 1980; 61: 70–76.[Free Full Text]

23. Brown BG, Bolson EL, Dodge HT. Dynamic mechanisms in human coronary stenosis. Circulation. 1984; 70: 917–922.[Abstract/Free Full Text]

24. Gould KL. Collapsing stenoses. In: Coronary Artery Stenosis and Reversing Atherosclerosis. London, UK: Arnold; 1999: 79–92.

25. Aoki T, Ku DN. Collapse of diseased arteries with eccentric cross-section. J Biomech. 1993; 26: 133–142.[CrossRef][Medline] [Order article via Infotrieve]

26. Siebes M, D’Argenio DZ, Campbell CS. Fluid dynamics of a partially collapsible stenosis in a flow model of the coronary circulation. J Biomech Eng. 1996; 118: 489–497.[Medline] [Order article via Infotrieve]

27. Van Liebergen RAM, Piek JJ, Koch KT, et al. Immediate and long-term effect of balloon angioplasty or stent implantation on the absolute and relative coronary blood flow velocity reserve. Circulation. 1998; 98: 2133–2140.[Abstract/Free Full Text]

28. Chamuleau SA, Siebes M, Meuwissen M, et al. The association between coronary lesion severity and distal microvascular resistance in patients with coronary artery disease. Am J Physiol Heart Circ Physiol. 2003; 285: H2194–H2200.[Abstract/Free Full Text]

29. Ofili EO, Kern MJ, St Vrain JA, et al. Differential characterization of blood flow, velocity, and vascular resistance between proximal and distal normal epicardial human coronary arteries: analysis by intracoronary Doppler spectral flow velocity. Am Heart J. 1995; 130: 37–46.[CrossRef][Medline] [Order article via Infotrieve]




This article has been cited by other articles:


Home page
HeartHome page
J A Spaan
Coronary flow is not that simple!
Heart, May 1, 2009; 95(9): 761 - 762.
[Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
H. Kitabata, T. Imanishi, T. Kubo, S. Takarada, M. Kashiwagi, H. Matsumoto, H. Tsujioka, H. Ikejima, Y. Arita, K. Okochi, et al.
Coronary Microvascular Resistance Index Immediately After Primary Percutaneous Coronary Intervention as a Predictor of the Transmural Extent of Infarction in Patients With ST-Segment Elevation Anterior Acute Myocardial Infarction.
J. Am. Coll. Cardiol. Img., March 1, 2009; 2(3): 263 - 272.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
R. Torii, N. B. Wood, N. Hadjiloizou, A. W. Dowsey, A. R. Wright, A. D. Hughes, J. Davies, D. P. Francis, J. Mayet, G.-Z. Yang, et al.
Stress phase angle depicts differences in coronary artery hemodynamics due to changes in flow and geometry after percutaneous coronary intervention
Am J Physiol Heart Circ Physiol, March 1, 2009; 296(3): H765 - H776.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
C. Kolyva, B.-J. Verhoeff, J. A. E. Spaan, J. J. Piek, and M. Siebes
Increased diastolic time fraction as beneficial adjunct of {alpha}1-adrenergic receptor blockade after percutaneous coronary intervention
Am J Physiol Heart Circ Physiol, November 1, 2008; 295(5): H2054 - H2060.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
A. R. Pries, H. Habazettl, G. Ambrosio, P. R. Hansen, J. C. Kaski, V. Schachinger, H. Tillmanns, G. Vassalli, I. Tritto, M. Weis, et al.
A review of methods for assessment of coronary microvascular disease in both clinical and experimental settings
Cardiovasc Res, November 1, 2008; 80(2): 165 - 174.
[Abstract] [Full Text] [PDF]


Home page
Phil Trans R Soc AHome page
J. Spaan, C. Kolyva, J. van den Wijngaard, R. ter Wee, P. van Horssen, J. Piek, and M. Siebes
Coronary structure and perfusion in health and disease
Phil Trans R Soc A, September 13, 2008; 366(1878): 3137 - 3153.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
C. Kolyva, J. A. E. Spaan, J. J. Piek, and M. Siebes
Windkesselness of coronary arteries hampers assessment of human coronary wave speed by single-point technique
Am J Physiol Heart Circ Physiol, August 1, 2008; 295(2): H482 - H490.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
J. J. Piek
Beyond Epicardial Reperfusion
N. Engl. J. Med., May 3, 2007; 356(18): 1880 - 1882.
[Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
H. J. Verberne, M. Meuwissen, S. A. J. Chamuleau, B.-J. Verhoeff, B. L. F. van Eck-Smit, J. A. E. Spaan, J. J. Piek, and M. Siebes
Effect of simultaneous intracoronary guidewires on the predictive accuracy of functional parameters of coronary lesion severity
Am J Physiol Heart Circ Physiol, May 1, 2007; 292(5): H2349 - H2355.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. J. Kern, A. Lerman, J.-W. Bech, B. De Bruyne, E. Eeckhout, W. F. Fearon, S. T. Higano, M. J. Lim, M. Meuwissen, J. J. Piek, et al.
Physiological Assessment of Coronary Artery Disease in the Cardiac Catheterization Laboratory: A Scientific Statement From the American Heart Association Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology
Circulation, September 19, 2006; 114(12): 1321 - 1341.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
O. Sorop, E. N. T. P. Bakker, A. Pistea, J. A. E. Spaan, and E. VanBavel
Calcium channel blockade prevents pressure-dependent inward remodeling in isolated subendocardial resistance vessels
Am J Physiol Heart Circ Physiol, September 1, 2006; 291(3): H1236 - H1245.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. K.C. Ng, A. C. Yeung, and W. F. Fearon
Invasive Assessment of the Coronary Microcirculation: Superior Reproducibility and Less Hemodynamic Dependence of Index of Microcirculatory Resistance Compared With Coronary Flow Reserve
Circulation, May 2, 2006; 113(17): 2054 - 2061.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
J. E. Davies, Z. I. Whinnett, D. P. Francis, K. Willson, R. A. Foale, I. S. Malik, A. D. Hughes, K. H. Parker, and J. Mayet
Use of simultaneous pressure and velocity measurements to estimate arterial wave speed at a single site in humans
Am J Physiol Heart Circ Physiol, February 1, 2006; 290(2): H878 - H885.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. A.E. Spaan, J. J. Piek, J. I.E. Hoffman, and M. Siebes
Physiological Basis of Clinically Used Coronary Hemodynamic Indices
Circulation, January 24, 2006; 113(3): 446 - 455.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
J. W. G. E. VanTeeffelen, S. Dekker, D. S. Fokkema, M. Siebes, H. Vink, and J. A. E. Spaan
Hyaluronidase treatment of coronary glycocalyx increases reactive hyperemia but not adenosine hyperemia in dog hearts
Am J Physiol Heart Circ Physiol, December 1, 2005; 289(6): H2508 - H2513.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
A. S. Roy, R. K. Banerjee, L. H. Back, M. R. Back, S. Khoury, and R. W. Millard
Delineating the guide-wire flow obstruction effect in assessment of fractional flow reserve and coronary flow reserve measurements
Am J Physiol Heart Circ Physiol, July 1, 2005; 289(1): H392 - H397.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
D. S. Fokkema, J. W. G. E. VanTeeffelen, S. Dekker, I. Vergroesen, J. B. Reitsma, and J. A. E. Spaan
Diastolic time fraction as a determinant of subendocardial perfusion
Am J Physiol Heart Circ Physiol, May 1, 2005; 288(5): H2450 - H2456.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
B.-J. Verhoeff, M. Siebes, M. Meuwissen, B. Atasever, M. Voskuil, R. J. de Winter, K. T. Koch, J. G.P. Tijssen, J. A.E. Spaan, and J. J. Piek
Influence of Percutaneous Coronary Intervention on Coronary Microvascular Resistance Index
Circulation, January 4, 2005; 111(1): 76 - 82.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Siebes, M.
Right arrow Articles by Piek, J. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Siebes, M.
Right arrow Articles by Piek, J. J.
Related Collections
Right arrow Pathophysiology
Right arrow Catheter-based coronary interventions: stents
Right arrow Coronary imaging: angiography/ultrasound/Doppler/CC
Right arrow Coronary circulation