(Circulation. 2004;110:3234-3238.)
© 2004 American Heart Association, Inc.
Imaging |
From the Department of Cardiology (E.M., A.D., C.R., F.R.) and Department of Diagnostic Imaging (A.R., M.T., M.S., G.S.), Tor Vergata University, Rome, Italy, and Division of Cardiovascular Medicine (J.L.M.), University of Arkansas for Medical Sciences, Little Rock, Ark.
Correspondence to Eugenio Martuscelli, MD, Via Cola di Rienzo 212, 00192 Rome, Italy. E-mail e.martuscelli{at}libero.it
Received February 2, 2004; de novo received March 30, 2004; revision received June 15, 2004; accepted June 29, 2004.
| Abstract |
|---|
|
|
|---|
Methods and Results In 96 patients (80 males, mean age 62 years) with previous CABG, a multislice computed tomography (MSCT) scan was performed (collimation 16x0.625 mm). Patients with atrial fibrillation, renal failure, severe respiratory disease, severe heart failure, heart rate >70 bpm despite therapy, or unstable angina were excluded. A total of 285 conduits implanted on the native coronary arteries at the time of CABG were evaluated. MSCT data were analyzed by 2 independent radiologists and compared with the results of conventional angiography. Three patients were excluded from analysis. All conduits were judged evaluable in 84 patients. Among these patients, MSCT correctly diagnosed 54 occluded grafts and 4 significant stenoses on the body of the grafts. Of the 17 significant anastomotic lesions, MSCT correctly diagnosed 15. For these 84 patients, diagnostic accuracy was 99%, sensitivity was 97%, and specificity was 100%. When all 93 patients were considered, the sensitivity of MSCT in diagnosing significant stenoses was 96%.
Conclusions MSCT with the new-generation scanner allows for accurate assessment of venous and arterial conduits in patients with previous CABG with a high degree of sensitivity and specificity. Exclusion criteria and radiation exposure remain limitations of the method.
Key Words: computed tomography angiography bypass surgery
| Introduction |
|---|
|
|
|---|
Venous and arterial conduits are ideal vessels for evaluation by MSCT because of their greater diameter, their direction with reference to the plane of the cross beam, and their relative spatial fixation. Arterial and venous conduits are usually free of severe calcification, which can impair assessment of the coronary lumen by this method.9 Several investigators have examined the potential of MSCT to detect bypass graft occlusion and stenosis. The first-generation MSCT scanner, which is able to acquire 4 slices with a subsecond rotation time, showed high sensitivity and specificity in the detection of venous and arterial occlusions, but identification of the presence or absence of significant stenoses was still inadequate (ie, 62%) for the application of this method in the clinical setting.1016 The introduction of a new-generation MSCT scanner with an isodimensional voxel (isotropic resolution) and the ability to acquire up to 16 submillimetric slices provides more accurate detection of the vascular lumen with a shorter scan time and less occurrence of cardiac or respiratory artifacts. This new-generation MSCT challenges the value of conventional angiography in coronary artery imaging.1721 In the present study, we examined the accuracy of the 16-slice MSCT scanner in the detection of patency and stenoses of arterial and venous conduits in patients who previously had CABG.
| Methods |
|---|
|
|
|---|
All patients received a ß-blocker (atenolol 50 to 100 mg/d, based on body mass and basal heart rate) at least 3 days before MSCT to obtain a stable low heart rate. Exclusion criteria for inclusion in the study were presence of multiple ectopic beats, atrial fibrillation, heart rate
70 bpm despite therapy, renal insufficiency, severe lung disease, severe heart failure (Canadian Cardiac Society class IV), and unstable angina. The study protocol was approved by the institutional review board.
MSCT Scan Protocol
MSCT was performed with a General Electric LightSpeed-16 scanner. First, a noncontrast localization scan was performed that yielded an anteroposterior view of the chest; this allowed us to position the imaging volume, which extended from the distal tract of the ascending aorta to the inferior border of the heart. Next, a precise estimation of the contrast agent transit time was made with a bolus intravenous injection of 40 mL of nonionic low-osmolality contrast agent (Iopamiro 370, Bracco spa). In the third step, the volume data set was acquired in spiral mode with simultaneous acquisition of 16 parallel slices with collimation 16x0.625 mm. The gantry rotation time was 500 ms, peak tube voltage was 140 kV, tube current was 10 to 440 mA in 5-mA increments, and the table feed averaged 2.9 mm/rotation. Contrast agent (145 mL, 4 mL/s) was injected as a single injection, and CT scan was initiated with a delay based on the previously determined contrast agent transit time. Patients were instructed to hold their breath during the scan. To facilitate the relatively long period of breath holding, a short session of hyperventilation was performed before patients were scanned. ECG was digitized and recorded continuously in all patients. Depending on the covered volume (mean 146 mm, range 125 to 180 mm), the scan time was 25 to 32 seconds (mean 28 seconds), and the breath holding time was 27 to 33 seconds (mean 31 seconds).
Image Reconstruction
ECG-gated image reconstruction was made with a desktop environment (ImageWork, General Electric). We used 2 reconstruction algorithms depending on the heart rate. If the heart rate was <60 bpm, a single sector for image reconstruction was used with a temporal resolution of 250 ms; if the heart rate was between 60 and 70 bpm, 2 sectors for image reconstruction were used with a temporal resolution of 125 ms. Transaxial images were reconstructed with a slice thickness of 0.625 mm at 0.4-mm increments, optimizing the position of the reconstruction window by increment or decrement of 10% in a range between 40% and 80%.
The image data set was transferred to a dedicated work station (Advantage window 4.1, General Electric) for postprocessing. Depending on vessel morphology and quality of the data, several postprocessing techniques were applied to assess arterial and venous conduits. These included thin-slab maximum-intensity projection, reconstruction of multiple curved cross sections, vessel tracking, and 3D volume rendering.22 Two radiologists experienced in cardiac CT evaluated the images independently without knowledge of the coronary angiograms.
Data Analysis
Both readers classified arterial and venous conduits as evaluable or unevaluable by visual estimation. Evaluable conduits were classified as patent or occluded. In patent grafts, presence or absence of a significant stenosis (
50% reduction in diameter) was identified. Stenoses were classified on the basis of their location in the body of the graft and at the anastomotic site. In case of disagreement between the 2 readers, a decision was reached by consensus.
Conventional Coronary Angiography
Conventional coronary angiography was performed with Philips Integris 5000 equipment (Medical Philips System [MPS]). Angiograms were evaluated by an expert cardiologist without knowledge of the MSCT results. Quantitative coronary analysis was performed offline by a resident MPS program that used the catheter tip for calibration. A diameter reduction
50% was defined as significant.
Statistical Analysis
Conventional coronary angiography was regarded as the standard of reference. Accuracy of MSCT was expressed in terms of sensitivity, specificity, positive predictive value, and negative predictive value. Concordance between readers 1 and 2 for the detection of occlusion or significant conduit stenosis by MSCT was calculated by the Cohen
-value, according to the formula
=IoIe/1Ie, where Io is the observed concordance and Ie the expected concordance.
| Results |
|---|
|
|
|---|
In the 84 fully evaluable patients, 251 conduits were available for analysis; of these, 85 were arterial and 166 venous (Table). Of the 85 arterial conduits, 12 were judged to be occluded (Figure 1A) and 73 patent by MSCT, with a sensitivity and specificity of 100%. Of the 166 venous conduits, 42 were judged to be occluded and 124 patent by MSCT (Figure 2), with a sensitivity and specificity of 100%. Relative to the detection of significant stenosis, 4 angiographic stenoses were localized in the body of the conduits (Figure 1B) and 17 at the anastomotic site (Figure 3). MSCT diagnosed correctly all stenoses localized in the body, but 2 of the 17 anastomotic site lesions could not be defined by MSCT, probably because of insufficient opacification of the distal anastomoses. Thus, sensitivity of MSCT was 90% and specificity 100% for assessment of conduit stenosis. Considering all data on occluded conduits and significant stenoses, sensitivity of MSCT was 97%, specificity was 100%, and diagnostic accuracy was 99%.
|
|
|
|
When all patients who were judged to be fully evaluable and those who were judged to be incompletely evaluable were considered together, MSCT identified 46 venous conduits as occluded and 12 arterial conduits as occluded, with a sensitivity and specificity of 100%. Relative to the detection of significant stenoses, MSCT correctly identified all 4 significant stenoses localized in the body of the graft and 15 of the 18 significant stenoses localized on the anastomotic site. All 3 significant stenoses not identified by MSCT were on the distal anastomotic site. Overall sensitivity was 96%. The
-value for interobserver variation in the detection of patency and significant stenoses of arterial and venous conduits was 0.95.
| Discussion |
|---|
|
|
|---|
Relative to the role of MSCT, Ropers et al16 performed a prospective comparison of MSCT with invasive coronary angiography in 65 patients with CABG, using a scanner able to acquire 4 parallel slices of heart of 1-mm collimation. Accuracy of MSCT in the detection of occluded conduits was very high, with sensitivity and specificity rates of 97% and 98%, respectively; however, 38% of 124 patent grafts could be not evaluated by MSCT because of insufficient suppression of respiratory and motion artifacts (11 cases), arrhythmias (5 cases), poor opacification (7 cases), and metallic clips (17 cases). Within the limits of conduits judged evaluable, sensitivity and specificity in the detection of significant stenosis were 75% and 92%, respectively. When conduits judged unevaluable were included in the analysis, the overall accuracy for detection of stenoses was quite low, with a sensitivity of 48%.
To the best of our knowledge, the present study is the first prospective investigation of the new-generation scanner in the imaging of arterial and venous conduits. Compared with the old-generation 4-slice MSCT, this scanner presents many important technical improvements that can explain the high level of accuracy. For example, spatial resolution is greatly improved by simultaneous acquisition of 16 slices as thin as 0.625 mm and by the potential to have an isodimensional volume element (isotropic voxel). Furthermore, as with conventional x-ray equipment, image noise decreases and image quality improves as the number of photons received by the detector arrays increases.22 This scanner has an x-ray tube that is able to deliver a high tube current, which means a much better signal/noise ratio and much better quality of the images. Because of this, metal clips can be defined clearly (Figure 1A) and do not impair analysis of blood vessels. In the present study, 88% of patients were judged fully evaluable, and only 3 distal anastomotic stenoses were missed by MSCT, with an overall sensitivity of 96%. In spite of this, some limitations of the method are still present.
Limitations of the Method
Metal ceramic x-ray tubes able to deliver high tube current may be a concern in terms of exposure of the patient to radiation. We do not have specific data on radiation exposure, but it is likely that the effective dose is higher than 8 to 9 mSv, which is the mean dose for patients undergoing 16-slice MSCT for evaluation of native coronary arteries18 and is much higher than the dose received during conventional coronary angiography.26,27 Nonetheless, a roentgen-modulation ECG gating can reduce radiation exposure by up to 50%.18 Second, atrial fibrillation should be considered a contraindication to MSCT, but atrial or ventricular ectopic beats can impair quality of the images, rendering them useless.28 Third, flow characteristics of the bypass, including direction of the filling and runoff, are related to the integrity of the wall of the conduit and to resistance in the native coronary artery. Data acquisition by MSCT is not capable of providing information about flow characteristics and the functional state of the conduit. Fourth, infusion of a large amount of iodine contrast agent is a limitation of MSCT. Because of this, patients with severe heart failure or overt renal failure were excluded from the present study.
Presence of severe respiratory disease was also considered an exclusion criteria in the present study because of the duration of the breath holding required for data acquisition. In addition, patients with unstable angina were sent immediately for conventional coronary angiography. Heart rate >70 bpm is not a contraindication for MSCT evaluation; however, at low heart rates, a reconstruction algorithm with 1 or 2 sectors for reconstruction allows for better definition of the metal clips and distal anastomosis.
It has been shown that 16-slice MSCT can be useful in the assessment of native coronary arteries.1821 The evaluation of native coronary circulation was not the aim of the present study, and thus, we cannot provide detailed information on this aspect. It has been shown in previous studies with 4-slice MSCT that severe calcifications and extensive atherosclerotic disease of the native coronary arteries are frequently found in patients with previous CABG, and these factors impair the evaluability of the native coronary segments and limit the accuracy of the method.29
Future Directions
Scanners able to acquire up to 64 slices with a slice thickness of <0.5 mm and served with a gantry rotation time <400 ms will soon be available for clinical use. These will greatly reduce the time required for data acquisition, reducing the duration of breath holding and reducing motion artifacts. This will also reduce the amount of contrast medium required for the scan. These factors are likely to translate into clinically significant improvements in diagnostic accuracy and applicability of the method.
| Conclusions |
|---|
|
|
|---|
| Acknowledgments |
|---|
| References |
|---|
|
|
|---|
2. Kahl FR, Wolfman NT, Watts LE. Evaluation of aortocoronary bypass graft status by computed tomography. Am J Cardiol. 1981; 48: 304310.[CrossRef][Medline] [Order article via Infotrieve]
3. McKay CR, Brundage BH, Ullyot DJ, et al. Evaluation of early postoperative coronary artery bypass graft patency by contrast-enhanced computed tomography. J Am Coll Cardiol. 1983; 2: 312317.[Abstract]
4. Moncada R, Salinas M, Churchill R, et al. Patency of saphenous aortocoronary-bypass grafts demonstrated by computed tomography. N Engl J Med. 1980; 303: 503505.[Medline] [Order article via Infotrieve]
5. Daniel WG, Dohring W, Stender HS, et al. Value and limitations of computed tomography in assessing aortocoronary bypass graft patency. Circulation. 1983; 67: 983987.
6. Engelmann MG, von Smekal A, Knez A, et al. Accuracy of spiral computed tomography for identifying arterial and venous coronary graft patency. Am J Cardiol. 1997; 80: 569574.[CrossRef][Medline] [Order article via Infotrieve]
7. Engelmann MG. Non-invasive coronary bypass graft imaging. Radiography. 2000; 6: 5562.[Medline] [Order article via Infotrieve]
8. Ueyama K, Ohashi H, Tsutsumi Y, et al. Evaluation of coronary artery bypass grafts using helical scan computed tomography. Catheter Cardiovasc Interv. 1999; 46: 322326.[CrossRef][Medline] [Order article via Infotrieve]
9. Kuettner A, Kopp AF, Schroeder S, et al. Diagnostic accuracy of multidetector computed tomography coronary angiography in patients with angiographically proven coronary artery disease. J Am Coll Cardiol. 2004; 43: 831839.
10. Engelmann MG, Knez A, von Smekal A, et al. Non-invasive coronary bypass graft imaging after multivessel revascularization. Int J Cardiol. 2000; 76: 6574.[CrossRef][Medline] [Order article via Infotrieve]
11. Frohner S, Wagner M, Schmitt R, et al. Multi-slice CT of aortocoronary venous bypasses and mammary artery bypasses: evaluation of bypasses and their anastomoses. Rontgenpraxis. 2002; 54: 163173.[Medline] [Order article via Infotrieve]
12. Yoo KJ, Choi D, Choi BW, et al. The comparison of the graft patency after coronary artery bypass grafting using coronary angiography and multi-slice computed tomography. Eur J Cardiothorac Surg. 2003; 24: 8691.
13. Burgstahler C, Kuettner A, Kopp AF, et al. Non-invasive evaluation of coronary artery bypass grafts using multi-slice computed tomography: initial clinical experience. Int J Cardiol. 2003; 90: 275280.[CrossRef][Medline] [Order article via Infotrieve]
14. Ko YG, Choi DH, Jang YS, et al. Assessment of coronary artery bypass graft patency by multislice computed tomography. Yonsei Med J. 2003 30; 44: 438444.[Medline] [Order article via Infotrieve]
15. Silber S, Finsterer S, Krischke I, et al. Noninvasive angiography of coronary bypass grafts with cardio-CT in a cardiology practice. Herz. 2003; 28: 126135.[CrossRef][Medline] [Order article via Infotrieve]
16. Ropers D, Ulzheimer S, Wenkel E, et al. Investigation of aortocoronary artery bypass grafts by multislice spiral computed tomography with electrocardiographic-gated image reconstruction. Am J Cardiol. 2001; 88: 792795.[CrossRef][Medline] [Order article via Infotrieve]
17. Gurevitch J, Gaspar T, Orlov B, et al. Noninvasive evaluation of arterial grafts with newly released multidetector computed tomography. Ann Thorac Surg. 2003; 76: 15231527.
18. Nieman K, Cademartiri F, Lemos PA, et al. Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation. 2002; 106: 20512054.
19. Ropers D, Baum U, Pohle K, et al. Detection of coronary artery stenoses with thin slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation. 2003; 107: 664666.
20. Cademartiri F, Nieman K, Mollet N, et al. Non-invasive 16-row spiral multislice computed tomography coronary angiography after one year of experience. Ital Heart J. 2003; 4: 587593.
21. Martuscelli E, Romagnoli A, DEliseo A, et al. Accuracy of thin slice computed tomography in the detection of coronary stenoses. Eur Heart J. 2004; 25: 10431048.
22. Morgan-Hughes GJ, Marshall AJ, Roobottom CA. Multislice computed tomography cardiac imaging: current status. Clin Radiol. 2002; 57: 872882.[CrossRef][Medline] [Order article via Infotrieve]
23. Budoff MJ, Achenbach S, Duerinckx A. Clinical utility of computed tomography and magnetic resonance techniques for noninvasive coronary angiography. J Am Coll Cardiol. 2003; 42: 18671878.
24. Langerak SE, Vliegen HW, Jukema JW, et al. Value of magnetic resonance imaging for the noninvasive detection of stenosis in coronary artery bypass grafts and recipients coronary arteries. Circulation. 2003; 107: 10521058.
25. Wittlinger TH, Voigtlander T, Kreitner KF, et al. Non-invasive magnetic resonance imaging of coronary bypass grafts: comparison of the haste and navigator techniques with conventional coronary angiography. Int J Cardiovasc Imaging. 2002; 18: 469477.[CrossRef][Medline] [Order article via Infotrieve]
26. Hunold P, Vogt FM, Schmermund A, et al. Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT. Radiology. 2003; 226: 145152.
27. Cusma JT, Bell MR, Wondrow MA, et al. Real-time measurement of radiation exposure to patients during diagnostic coronary angiography and percutaneous interventional procedures. J Am Coll Cardiol. 1999; 33: 427435.
28. Nieman K, Rensing BJ, van Geuns RJ, et al. Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate. Heart. 2002; 88: 470474.
29. Nieman K, Pattynama PM, Rensing BJ, et al. Evaluation of patients after coronary artery bypass surgery: angiographic assessment of grafts and coronary arteries. Radiology. 2003; 229: 749756.
This article has been cited by other articles:
![]() |
P G CAMPBELL, K S L TEO, S G WORTHLEY, M T KEARNEY, A TARIQUE, A NATARAJAN, and A G ZAMAN Non-invasive assessment of saphenous vein graft patency in asymptomatic patients Br. J. Radiol., April 1, 2009; 82(976): 291 - 295. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. A. Bluemke, S. Achenbach, M. Budoff, T. C. Gerber, B. Gersh, L. D. Hillis, W. G. Hundley, W. J. Manning, B. F. Printz, M. Stuber, et al. Noninvasive Coronary Artery Imaging: Magnetic Resonance Angiography and Multidetector Computed Tomography Angiography: A Scientific Statement From the American Heart Association Committee on Cardiovascular Imaging and Intervention of the Council on Cardiovascular Radiology and Intervention, and the Councils on Clinical Cardiology and Cardiovascular Disease in the Young Circulation, July 29, 2008; 118(5): 586 - 606. [Full Text] [PDF] |
||||
![]() |
M. Hamon, O. Lepage, P. Malagutti, J. W. Riddell, R. Morello, D. Agostini, and M. Hamon Diagnostic Performance of 16- and 64-Section Spiral CT for Coronary Artery Bypass Graft Assessment: Meta-Analysis Radiology, June 1, 2008; 247(3): 679 - 686. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. J. Rybicki, T. Sheth, and F. Y. Chen Cardiac Surgical Imaging Card. Surg. Adult, January 1, 2008; 3(2008): 179 - 198. [Full Text] |
||||
![]() |
A. R. Simon, H. Baraki, J. Weidemann, W. Harringer, M. Galanski, and A. Haverich High-resolution 64-slice helical-computer-assisted-tomographical-angiography as a diagnostic tool before CABG surgery: the dawn of a new era? Eur. J. Cardiothorac. Surg., December 1, 2007; 32(6): 896 - 901. [Abstract] [Full Text] [PDF] |
||||
![]() |
N I Stauder, B Klumpp, H Stauder, G Blumenstock, M Fenchel, A Kuttner, C D Claussen, and S Miller Assessment of coronary artery bypass grafts by magnetic resonance imaging Br. J. Radiol., December 1, 2007; 80(960): 975 - 983. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Deetjen, S. Mollmann, G. Conradi, A. Rolf, A. Schmermund, C. W Hamm, and T. Dill Use of automatic exposure control in multislice computed tomography of the coronaries: comparison of 16-slice and 64-slice scanner data with conventional coronary angiography Heart, September 1, 2007; 93(9): 1040 - 1043. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Malagutti, K. Nieman, W. B. Meijboom, C. A.G. van Mieghem, F. Pugliese, F. Cademartiri, N. R. Mollet, E. Boersma, P. P. de Jaegere, and P. J. de Feyter Use of 64-slice CT in symptomatic patients after coronary bypass surgery: evaluation of grafts and coronary arteries Eur. Heart J., August 1, 2007; 28(15): 1879 - 1885. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Andreini, G. Pontone, G. Ballerini, E. Bertella, E. Nobili, A. Parolari, and M. Pepi Bypass Graft and Native Postanastomotic Coronary Artery Patency: Assessment With Computed Tomography Ann. Thorac. Surg., May 1, 2007; 83(5): 1672 - 1678. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. F. Di Carli and R. Hachamovitch New Technology for Noninvasive Evaluation of Coronary Artery Disease Circulation, March 20, 2007; 115(11): 1464 - 1480. [Full Text] [PDF] |
||||
![]() |
C. M. Jones, T. Athanasiou, N. Dunne, J. Kirby, O. Aziz, A. Haq, C. Rao, V. Constantinides, S. Purkayastha, and A. Darzi Multi-Detector Computed Tomography in Coronary Artery Bypass Graft Assessment: A Meta-Analysis Ann. Thorac. Surg., January 1, 2007; 83(1): 341 - 348. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Ropers, F.-K. Pohle, A. Kuettner, T. Pflederer, K. Anders, W. G. Daniel, W. Bautz, U. Baum, and S. Achenbach Diagnostic Accuracy of Noninvasive Coronary Angiography in Patients After Bypass Surgery Using 64-Slice Spiral Computed Tomography With 330-ms Gantry Rotation Circulation, November 28, 2006; 114(22): 2334 - 2341. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Achenbach Computed Tomography Coronary Angiography J. Am. Coll. Cardiol., November 21, 2006; 48(10): 1919 - 1928. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Budoff, S. Achenbach, R. S. Blumenthal, J. J. Carr, J. G. Goldin, P. Greenland, A. D. Guerci, J. A.C. Lima, D. J. Rader, G. D. Rubin, et al. Assessment of Coronary Artery Disease by Cardiac Computed Tomography: A Scientific Statement From the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology Circulation, October 17, 2006; 114(16): 1761 - 1791. [Full Text] [PDF] |
||||
![]() |
T. Wittlinger, O. Dzemali, I. Martinovic, and A. Moritz Assessment of coronary artery bypass grafts patency with different magnetic resonance technologies. Eur. J. Cardiothorac. Surg., September 1, 2006; 30(3): 436 - 442. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. M. Jones, T. Athanasiou, N. Dunne, J. Kirby, S. Attaran, A. Chow, S. Purkayastha, and A. Darzi Multi-slice computed tomography in coronary artery disease. Eur. J. Cardiothorac. Surg., September 1, 2006; 30(3): 443 - 450. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Di Lazzaro, T. Ragni, G. Di Manici, G. Bardelli, U. Da Col, F. Grasselli, A. Antoniella, W. Papa, F. Crusco, and A. Giovagnoni Noninvasive midterm follow-up of radial artery bypass grafts with 16-slice computed tomography. Ann. Thorac. Surg., July 1, 2006; 82(1): 44 - 50. [Abstract] [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2004 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |