(Circulation. 2004;110:3378-3383.)
© 2004 American Heart Association, Inc.
Basic Science for Clinicians |
From the Division of Hematology/Oncology, Department of Radiology, and Molecular Imaging Center, Beth Israel Deaconess Medical Center (J.V.F.); the Cardiology Laboratory of Integrative Physiology & Imaging, Cardiovascular Research Center, Massachusetts General Hospital (R.J.H.); and Harvard Medical School (J.V.F., R.J.H.), Boston, Mass.
Correspondence to John V. Frangioni, MD, PhD, Division of Hematology/Oncology, Beth Israel Deaconess Medical Center, 330 Brookline Ave, SL-B05, Boston, MA 02215. E-mail jfrangio{at}bidmc.harvard.edu
Abstract
Various stem cells hold promise for the treatment of human cardiovascular disease. Regardless of stem cell origin, future clinical trials will require that the location and number of such cells be tracked in vivo, over long periods of time. The problem of tracking small numbers of cells in the body is a difficult one, and an optimal solution does not yet exist. We review the many contrast agents and detectors that have been proposed for stem cell tracking during clinical trials, define the characteristics of an ideal imaging technology, and suggest future directions for research.
Key Words: stem cells imaging trials radiology
With the rapid increase of reported cases of stem cells being used to treat cardiovascular disease, it has become apparent that an urgent need exists to track stem cells in vivo during clinical trials.
For example, stem cell therapy for heart failure addresses an important problem in clinical medicine. Heart failure is a major cause of morbidity and mortality in the United States. The rates of new and recurrent heart failure events increase substantially with age. In patients aged 65 and older, congestive heart failure is the single most frequent cause of hospitalization in the United States. Despite substantial advances in the clinical management of heart failure, the diagnosis continues to carry a grave prognosis with an overall 5-year mortality rate of
50%. This rate is substantially worse in more severely affected patient subsets. An understanding of the role of stem cells in repopulating damaged areas in the heart would help target these diseased areas.1
The problem of imaging small numbers of cells in the living subject is not limited to stem cellbased treatments in cardiology but has broad applicability in oncology, immunology, and transplantation.
Ideal Imaging Technology for Stem Cell Tracking
Successful in vivo imaging requires that a contrast agent associated with a stem cell exert an "effect size" sufficient for detection by imaging hardware. Although the most attractive contrast agents for tracking are endogenous ones (ie, normal components of the stem cell), their effect size is extremely small. This review will focus on exogenous contrast agents, which have a large and controllable effect size. It also will focus on imaging technology that has clinical relevance because many preclinical small animal studies in the field of stem cell tracking are not translatable to clinical practice.
The 8 characteristics of an ideal imaging technology for stem cell tracking are presented in Table 1. First, and foremost, the exogenous contrast agent must be biocompatible, safe, and nontoxic. This is especially important when nanotechnology solutions to the tracking problem (mentioned below) are considered, because most solid-state devices will be composed of materials that do not have proven long-term safety in vivo.
|
Another consideration is the need for genetic modification of the stem cell or perturbation of its genetic program by the contrast agent itself. Several imaging techniques, such as enzymatic conversion of an injected substrate and receptor-based binding, require stable integration of transgenes. This strategy may be combined with genetic manipulation of stem cell populations to enhance the viability, differentiation, and coupling of these cells with the myocardium. These types of manipulations add significant cost, regulatory roadblocks, and the potential to induce genetic abnormalities, including uncontrolled growth and malignancy.2 Although exogenous genes have the distinct advantage of not being diluted by cell division and have the potential to induce cell survival or suicide on demand,3 it is unclear at present if the extra step of genetic manipulation will become routine in human clinical stem cell trials.
Ideally, imaging technology used for stem cell tracking would have single-cell sensitivity and would permit quantification of exact cell numbers at any anatomic location. Single-cell sensitivity is especially important in a new field such as that of stem cells because the pattern of migration of stem cells, even after local injection, is unknown, and there is a distinct possibility that single stem cells scattered diffusely throughout the body might be effective therapeutics for certain disease states.
Regardless of the level of sensitivity finally achieved, quantification of cell number can be especially difficult when we consider the effects of contrast agent dilution during cell division, the propensity of some contrast agents to be transferred to nonstem cells, and certain technical limitations (discussed below). The criteria of ultra-high high sensitivity, quantification, and full-body scanning render many clinically available imaging modalities inadequate at present.
The ideal imaging technology would permit tracking of injected stem cells for months to years because clinical trials undoubtedly will require long-term follow-up of tissue function or host survival. Finally, injectable contrast agents, such as enzyme substrates, add complexity and cost to stem celltracking procedures.
Detection Methods for In Vivo Stem Cell Tracking
At present, no imaging technology fulfills the 8 criteria presented above, although some come close. The following is a discussion of the advantages and disadvantages of various imaging modalities that might be considered for clinical stem cell trials (Table 2).
|
X-RayBased Methods
Plain films and computed tomography (CT) are the most readily available clinical imaging modalities. Unfortunately, contrast generation requires extremely high concentrations of high-density/highatomic number materials such as iodine, gadolinium, or metals. To render a stem cell or collection of stem cells visible by using even a solid metal, the volume of metal associated with the cell volume must be equal to or greater than the inverse of its density. For example, it would take approximately one eighth of the cell volume in solid iron to generate a signal above background during CT scanning. Such contrast is difficult to achieve, rendering x-raybased methods unlikely to play a direct role in stem cell tracking at the present time.
Optical Imaging
Two complementary optical imaging methods, bioluminescence and fluorescence, can be used for stem cell tracking. Bioluminescence utilizes light generated by the enzyme luciferase to detect cells in vivo. Four published studies, 3 in mice46 and 1 in rats,7 utilized bioluminescence to track the distribution and engraftment of stem cells in vivo. Unfortunately, luciferase genes and substrates described to date generate only visible (400 to 700 nm) light, which has very high absorption and scatter in living tissue. This precludes use of the technique in animals larger than rats, and even in mice false-negative scanning can occur, dependent on cell depth.8 Bioluminescence also requires the stable expression of nonhuman genes, and the injection of high concentrations of potentially immunogenic, nonhuman substrates, such as luciferin and coelenterazine. It is therefore unlikely that this technique will be used clinically.
Fluorescence imaging utilizes organic (eg, green fluorescent protein, small-molecule polymethines) or organic/inorganic hybrids (eg, quantum dots) as exogenous contrast agents for in vivo imaging (reviewed in Frangioni9). Because of high photon absorption and scatter at visible wavelengths, only near-infrared (NIR) (700 to 1000 nm) fluorophores have clinical potential. The major problem with NIR fluorescence is that even with tomographic imaging methods, detection is limited to only 4 to 10 cm of tissue (reviewed in Ntziachristos et al10 and Sevick-Muraca et al11). Hence, clinical use of NIR fluorescence likely will be limited to near-surface applications, such as intraoperative imaging.1214 A major advantage of NIR fluorescence is its compatibility with conventional microscopy,15,16 permitting single-cell detection of stem cells in pathological specimens. Ex vivo histological detection of stem cells undoubtedly will be required in clinical trials. Major disadvantages of NIR fluorescence are the dilution of the agent with each cell division and the possibility of uptake by nonstem cells after stem cell death.
Ultrasound
Because cardiologists likely will conduct the majority of clinical studies of stem cells in cardiovascular applications, tracking by echocardiography would be extremely convenient. Contrast for echocardiography is generated by acoustic interfaces such as water/gas (eg, microbubbles, perfluorocarbons). Although a single unit of contrast is on the order of 0.25 to 1 µm in diameter, the generated acoustic perturbation appears much larger. Echocardiography therefore has the potential to detect a single cell loaded with a single unit of contrast.17 Nevertheless, methods to accumulate contrast intracellularly are not yet robust, and effects on cell motility, etc, are not known. An additional problem is that echogenic contrast agents cast an acoustic "shadow" below the first unit of contrast detected, thus precluding accurate quantification of cell number. Such contrast agents are subject to dilution during cell division and transfer to nonstem cells after cell death. Finally, spatial resolution of ultrasound is limited, and many anatomic sites are inaccessible.
Single-Photon Emission Computed Tomography
High-energy gamma rays emitted by radioactive atoms as 99mTc, 111In, and 123I are detected by rotating a collimated gamma camera around the subject and reconstructing a 3-dimensional image. Three strategies for in vivo stem cell detection have been described: direct loading with a radiometal,1821 enzymatic conversion and retention of a radioactive substrate (reviewed in Gambhir et al22), and receptor-mediated binding.22,23
Direct loading is problematic given the tradeoff between half-life and long-term exposure to ionizing radiation and given the possibility of transfer of the radiometal from stem cells to nonstem cells.
Enzymatic conversion/retention has been used for both single-photon emission CT (SPECT) and positron emission tomography (PET) (see below) substrates. The significant advantages of this strategy include the ability to follow stem cells indefinitely after stable integration of the transgene, the absence of marker dilution by cell division, and the ability to destroy stem cells by administration of a suicide drug specific for the enzyme. The disadvantages of this strategy include the need to genetically manipulate the stem cell ex vivo and the need to administer a substrate intravenously for each imaging session.
Receptor-mediated targeting requires stable expression of a receptor not found elsewhere in the body and intravenous injection of a radioactive receptor ligand.
Positron Emission Tomography
PET utilizes coincident detection of 2 anti-parallel 511-keV gamma rays emitted after positron annihilation. Tradeoffs exist between the higher energy of the photons, coincident detection, and detector efficiency, but overall, PET has a higher sensitivity than SPECT and permits more accurate quantification of cell number. Although the 3 strategies mentioned above for SPECT can be used for stem cell tracking with PET, the most advanced by far is the stable integration of a mutant herpes simplex type 1 thymidine kinase (TK) into stem cells and periodic intravenous injection of the TK substrate 18FHBG.7 Although it permits tracking and quantification of stem cells over the course of months, this strategy requires genetic manipulation of the stem cells, an infrastructure for 18F chemistry, a PET scanner, and radiation exposure (albeit it intermittent) to the stem cells and subject.
Additional caveats for SPECT- and PET-based tracking of stem cells include nonspecific uptake of the radiotracer by normal tissue, relatively low efficiency of collimated SPECT cameras, and photon attenuation by tissue. Although tissue photon attenuation can be corrected in some cases, for example by employing hybrid nuclear medicine/CT systems, it reduces sensitivity, and prevents accurate quantification of stem cell number.19 Whether used for attenuation correction or not, hybrid CT systems have the major advantage that they permit coregistration of anatomic (CT) and physiological (SPECT or PET) images.
Another (often overlooked) issue is the inherent limits of radioactive methods for stem cell detection. A typical patient dose of 10 to 20 mCi is equivalent to only 3.5 to 7x1012 radioactive molecules of contrast agent. In typical clinical nuclear medicine imaging,
109 radioactive molecules per milliliter (a milliliter being the order of magnitude of clinical resolution) are required to generate detectable signal above background (J. Anthony Parker, MD, PhD, Associate Professor of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, personal communication, April 15, 2004). To detect a single stem cell,
0.01% of the injected dose would have to be concentrated in/on the cell, which is a formidable technical challenge.
Magnetic Resonance Imaging
Given its extraordinary 3-dimensional capabilities and high safety profile, magnetic resonance imaging (MRI) is the imaging modality used by most research studies to track stem cells in vivo. At this point in time, MRI imaging techniques can be divided into those generating primarily T1 contrast and those generating primarily T2/T2* contrast.
T1 contrast agents are those that utilize the lanthanide gadolinium (Gd3+), which changes the relaxivity of protons from associated water molecules and increases the signal on T1-weighted images. Unfortunately, with presently available field strengths, Gd3+-based contrast requires 50- to 500-µmol/L concentrations of low-molecular-weight Gd3+-containing molecules or attachment to bulky scaffolds such as dendrimers and dextrans to increase the T1 effect. At least 3 studies in the literature demonstrate convincingly, however, that Gd3+-containing scaffolds, loaded via pino/endocytosis into stem cells, permit tracking for up to 6 weeks.2426
T2/T2* contrast is by far the most widely used technique for stem cell imaging studies using MRI. This is a consequence of the observation made by the Weissleder group in the early 1990s that superparamagnetic iron oxide nanoparticles (also known as monocrystalline iron oxide nanocrystals [MIONs], ultrasmall superparamagnetic iron oxide [USPIOs]) congeal in endosomes after endocytosis, resulting in magnification of their susceptibility effects. More recent formulations from this group utilize Tat peptides to improve cell loading, which can now be accomplished in <1 hour.27,28 Because of the magnification effect, MIONs can be used to track extremely small numbers of stem cells, on the order of thousands, at high field strengths, for up to several weeks. T2/T2* contrast agents (reviewed in Daldrup-Link et al29) and their technical improvements28,3033 already have been applied by many groups for stem cell tracking in vivo. Most superparamagnetic formulations appear to be biocompatible, safe, and nontoxic, and some already have been approved by the US Food and Drug Administration for nonstem cell applications. The problems with superparamagnetic particles include dilution of contrast with cell division; difficulty in quantification because of susceptibility artifact; and the potential transfer of contrast to nonstem cells, such as macrophages, after stem cell death.
A significant clinical problem common to all MRI methods is that certain implantable devices, such as pacemakers and defibrillators, are currently contraindications to scanning. Although a recent report suggests that patients with pacemakers can be scanned safely at 1.5 T,34 MRIs role in clinical stem cell trials remains unclear because patients with cardiac devices undoubtedly will be candidates for early stem cell clinical trials, and cardiac MRI is not readily available at all institutions.
Multimodality Contrast Agents
Because no single contrast agent/detector pair will satisfy all needs of stem cell clinical trials, dual- and multimodality contrast agents, which combine the best features of each technology, have been developed. Fluorophore-labeled MIONs permit injection of stem cells under optical image guidance and identification of single cells in pathological specimens ex vivo.35,36 Similar dual optical/MRI contrast has been described using visible-wavelength fluorophores and Gd3+ chelators conjugated to high-molecular-weight scaffolds such as dextran.26 Large nanoparticles generating simultaneous MRI, ultrasound, and fluorescence contrast have also been described (reviewed in Wickline and Lanza37) and might prove useful for multimodality stem cell tracking.
Published Stem Cell Imaging Studies
Tracking the movement of different types of stem cells has been an important focus in studies of cellular cardiomyoplasty (Table 3). The different types of stem cells have specific characteristics in their mode of delivery and engraftment.3845 Mesenchymal stem cells (MSCs), which can be isolated in adults and expanded in culture, have phenotypic characteristics of smooth muscle, skeletal myoblasts, and cardiac myocyte cells. A number of studies have shown that MSCs can reverse adverse remodeling when injected directly into the infarcted heart or after homing to the infarcted area when injected intravenously. Studies with MSCs have been performed in rodents and larger animals, and the fate and movements of the MSCs have been imaged with MRI, radioscintigraphy, and visible fluorescence. Hematopoietic cells and endothelial cells also have been targeted toward areas of infarcts within the heart and also have been visualized by various imaging modalities. With these cells, the therapeutic end point also includes neovascularization and angiogenesis, which often require other imaging modalities such as intravital microscopy and optical coherence tomography for assessment. Finally, embryonic stem cells are being tested in cardiac repair, and because their potential to differentiate and transmigrate is greater than that of adult stem cells, multiple imaging modalities may be required to assess the overall distribution of these cells.
|
Future Directions
Given the inherent limitations of currently available imaging technology, future research should focus on improving sensitivity while minimizing patient exclusion, study cost, and study complexity. Novel ideas would be welcomed in the field. Paramagnetic chemical exchange saturation transfer (PARACEST) agents for MRI have the potential to improve MRI sensitivity by up to 2 orders of magnitude (reviewed in Zhang et al46). Terahertz47 and other electromagnetic frequencies offer certain advantages, although exogenous contrast agents do not yet exist. Solid-state nanotechnology solutions, however remote at present, are particularly attractive because they could potentially provide noninvasive, real-time monitoring of intracellular pH, calcium, etc, as well as anatomic location, of single stem cells.
Conclusion
In conclusion, x-ray techniques do not provide adequate contrast sensitivity for cardiovascular stem cell tracking in the clinical setting. Bioluminescence is limited to small animal studies and NIR fluorescence to near-surface and histological applications. Ultrasound/echocardiography has the potential for single-cell detection but has limited anatomic accessibility, resolution, and quantification. High-energy photon imaging (SPECT or PET) has high sensitivity, but for long-term tracking it requires genetic manipulation of the stem cell, stable expression of a transgene, and multiple exposures to ionizing radiation. MRI provides excellent 3-dimensional anatomy but is contraindicated for many patients and has limited availability at many institutions, and some contrast techniques have low sensitivity. Although multimodality contrast agents might improve the prospects for stem cell tracking both in vivo and ex vivo, no currently available imaging technology is ideal. Impending clinical trials utilizing stem cells must define, carefully, the limits of the imaging technology chosen.
Acknowledgments
We thank Monica Seo-Yoon Jang (Massachusetts General Hospital) for assistance with literature review; Ralph Weissleder (Massachusetts General Hospital), Robert E. Lenkinski (Beth Israel Deaconess Medical Center), J. Anthony Parker (Beth Israel Deaconess Medical Center), Jonathan B. Kruskal (Beth Israel Deaconess Medical Center), and Neil M. Rofsky (Beth Israel Deaconess Medical Center) for critical review of this manuscript; and Grisel Rivera for administrative assistance. Dr Hajjar is a Beeson Scholar of the American Federation of Aging Research. Drs Hajjar and Frangioni are Clinical Scientist Development Award recipients of the Doris Duke Charitable Foundation. Other support was provided by grants from the Center for Integration of Medicine and Innovative Technology (CIMIT; Drs Hajjar and Frangioni), NIH R01-HL-57623 (Dr Hajjar), NIH R01-HL-73756 (Dr Hajjar), NCI R33-CA-88256 (Dr Frangioni), NCI R21-CA-88870 (Dr Frangioni), NIBIB R33-EB-00673 (Dr Frangioni), NHLBI R01-HL-078691 (Drs Hajjar and Frangioni), and Department of Energy (Office of Biological and Environmental Research) DE-FG0201ER63188 (Dr Frangioni).
References
1. Britten MB, Abolmaali ND, Assmus B, et al. Infarct remodeling after intracoronary progenitor cell treatment in patients with acute myocardial infarction (TOPCARE-AMI): mechanistic insights from serial contrast-enhanced magnetic resonance imaging. Circulation. 2003; 108: 22122218.
2. Hacein-Bey-Abina S, Von Kalle C, Schmidt M, et al. LMO2-associated clonal T cell proliferation in two patients after gene therapy for SCID-X1. Science. 2003; 302: 415419.
3. Klatzmann D, Valery CA, Bensimon G, et al. A phase I/II study of herpes simplex virus type 1 thymidine kinase "suicide" gene therapy for recurrent glioblastoma. Study Group on Gene Therapy for Glioblastoma. Hum Gene Ther. 1998; 9: 25952604.[CrossRef][Medline] [Order article via Infotrieve]
4. Wang X, Rosol M, Ge S, et al. Dynamic tracking of human hematopoietic stem cell engraftment using in vivo bioluminescence imaging. Blood. 2003; 102: 34783482.
5. Tang Y, Shah K, Messerli SM, et al. In vivo tracking of neural progenitor cell migration to glioblastomas. Hum Gene Ther. 2003; 14: 12471254.[CrossRef][Medline] [Order article via Infotrieve]
6. Cao YA, Wagers AJ, Beilhack A, et al. Shifting foci of hematopoiesis during reconstitution from single stem cells. Proc Natl Acad Sci U S A. 2004; 101: 221226.
7. Wu JC, Chen IY, Sundaresan G, et al. Molecular imaging of cardiac cell transplantation in living animals using optical bioluminescence and positron emission tomography. Circulation. 2003; 108: 13021305.
8. Rice BW, Cable MD, Nelson MB. In vivo imaging of light-emitting probes. J Biomed Opt. 2001; 6: 432440.[CrossRef][Medline] [Order article via Infotrieve]
9. Frangioni JV. In vivo near-infrared fluorescence imaging. Curr Opin Chem Biol. 2003; 7: 626634.[CrossRef][Medline] [Order article via Infotrieve]
10. Ntziachristos V, Bremer C, Weissleder R. Fluorescence imaging with near-infrared light: new technological advances that enable in vivo molecular imaging. Eur Radiol. 2003; 13: 195208.[Medline] [Order article via Infotrieve]
11. Sevick-Muraca EM, Houston JP, Gurfinkel M. Fluorescence-enhanced, near infrared diagnostic imaging with contrast agents. Curr Opin Chem Biol. 2002; 6: 642650.[CrossRef][Medline] [Order article via Infotrieve]
12. Reynolds JS, Troy TL, Mayer RH, et al. Imaging of spontaneous canine mammary tumors using fluorescent contrast agents. Photochem Photobiol. 1999; 70: 8794.[CrossRef][Medline] [Order article via Infotrieve]
13. Nakayama A, del Monte F, Hajjar RJ, et al. Functional near-infrared fluorescence imaging for cardiac surgery and targeted gene therapy. Molecular Imaging. 2002; 1: 365377.[Medline] [Order article via Infotrieve]
14. Kim S, Lim YT, Soltesz EG, et al. Near-infrared fluorescent type II quantum dots for sentinel lymph node mapping. Nat Biotechnol. 2004; 22: 9397.[CrossRef][Medline] [Order article via Infotrieve]
15. Zaheer A, Lenkinski RE, Mahmood A, et al. In vivo near-infrared fluorescence imaging of osteoblastic activity. Nat Biotechnol. 2001; 19: 11481154.[CrossRef][Medline] [Order article via Infotrieve]
16. Nakayama A, Bianco AC, Zhang CY, et al. Quantitation of brown adipose tissue perfusion in transgenic mice using near-infrared fluorescence imaging. Molecular Imaging. 2003; 2: 3749.[Medline] [Order article via Infotrieve]
17. Klibanov AL, Rasche PT, Hughes MS, et al. Detection of individual microbubbles of ultrasound contrast agents: imaging of free-floating and targeted bubbles. Invest Radiol. 2004; 39: 187195.[CrossRef][Medline] [Order article via Infotrieve]
18. Gao J, Dennis JE, Muzic RF, et al. The dynamic in vivo distribution of bone marrow-derived mesenchymal stem cells after infusion. Cells Tissues Organs. 2001; 169: 1220.[CrossRef][Medline] [Order article via Infotrieve]
19. Chin BB, Nakamoto Y, Bulte JW, et al. 111In oxine labelled mesenchymal stem cell SPECT after intravenous administration in myocardial infarction. Nucl Med Commun. 2003; 24: 11491154.[CrossRef][Medline] [Order article via Infotrieve]
20. Barbash IM, Chouraqui P, Baron J, et al. Systemic delivery of bone marrowderived mesenchymal stem cells to the infarcted myocardium: feasibility, cell migration, and body distribution. Circulation. 2003; 108: 863868.
21. Aicher A, Brenner W, Zuhayra M, et al. Assessment of the tissue distribution of transplanted human endothelial progenitor cells by radioactive labeling. Circulation. 2003; 107: 21342139.
22. Gambhir SS, Herschman HR, Cherry SR, et al. Imaging transgene expression with radionuclide imaging technologies. Neoplasia. 2000; 2: 118138.[CrossRef][Medline] [Order article via Infotrieve]
23. Simonova M, Shtanko O, Sergeyev N, et al. Engineering of technetium-99mbinding artificial receptors for imaging gene expression. J Gene Med. 2003; 5: 10561066.[CrossRef][Medline] [Order article via Infotrieve]
24. Bulte JW, Douglas T, Witwer B, et al. Magnetodendrimers allow endosomal magnetic labeling and in vivo tracking of stem cells. Nat Biotechnol. 2001; 19: 11411147.[CrossRef][Medline] [Order article via Infotrieve]
25. Bulte JW, Douglas T, Witwer B, et al. Monitoring stem cell therapy in vivo using magnetodendrimers as a new class of cellular MR contrast agents. Acad Radiol. 2002; 9 (suppl 2): S332S335.[CrossRef][Medline] [Order article via Infotrieve]
26. Modo M, Cash D, Mellodew K, et al. Tracking transplanted stem cell migration using bifunctional, contrast agent-enhanced, magnetic resonance imaging. Neuroimage. 2002; 17: 803811.[CrossRef][Medline] [Order article via Infotrieve]
27. Josephson L, Tung CH, Moore A, et al. High-efficiency intracellular magnetic labeling with novel superparamagnetic-Tat peptide conjugates. Bioconjug Chem. 1999; 10: 186191.[CrossRef][Medline] [Order article via Infotrieve]
28. Lewin M, Carlesso N, Tung CH, et al. Tat peptidederivatized magnetic nanoparticles allow in vivo tracking and recovery of progenitor cells. Nat Biotechnol. 2000; 18: 410414.[CrossRef][Medline] [Order article via Infotrieve]
29. Daldrup-Link HE, Rudelius M, Oostendorp RA, et al. Targeting of hematopoietic progenitor cells with MR contrast agents. Radiology. 2003; 228: 760767.
30. Frank JA, Miller BR, Arbab AS, et al. Clinically applicable labeling of mammalian and stem cells by combining superparamagnetic iron oxides and transfection agents. Radiology. 2003; 228: 480487.
31. van den Bos EJ, Wagner A, Mahrholdt H, et al. Improved efficacy of stem cell labeling for magnetic resonance imaging studies by the use of cationic liposomes. Cell Transplant. 2003; 12: 743756.[Medline] [Order article via Infotrieve]
32. Garot J, Unterseeh T, Teiger E, et al. Magnetic resonance imaging of targeted catheter-based implantation of myogenic precursor cells into infarcted left ventricular myocardium. J Am Coll Cardiol. 2003; 41: 18411846.
33. Hinds KA, Hill JM, Shapiro EM, et al. Highly efficient endosomal labeling of progenitor and stem cells with large magnetic particles allows magnetic resonance imaging of single cells. Blood. 2003; 102: 867872.
34. Martin ET, Coman JA, Shellock FG, et al. Magnetic resonance imaging and cardiac pacemaker safety at 1.5-Tesla. J Am Coll Cardiol. 2004; 43: 13151324.
35. Josephson L, Kircher MF, Mahmood U, et al. Near-infrared fluorescent nanoparticles as combined MR/optical imaging probes. Bioconjug Chem. 2002; 13: 554560.[CrossRef][Medline] [Order article via Infotrieve]
36. Hill JM, Dick AJ, Raman VK, et al. Serial cardiac magnetic resonance imaging of injected mesenchymal stem cells. Circulation. 2003; 108: 10091014.
37. Wickline SA, Lanza GM. Nanotechnology for molecular imaging and targeted therapy. Circulation. 2003; 107: 10921095.
38. Ford JW, Welling TH, 3rd, Stanley JC et al. PKH26 and 125I-PKH95: characterization and efficacy as labels for in vitro and in vivo endothelial cell localization and tracking. J Surg Res. 1996; 62: 2328.[CrossRef][Medline] [Order article via Infotrieve]
39. Askenasy N, Farkas DL. Optical imaging of PKH-labeled hematopoietic cells in recipient bone marrow in vivo. Stem Cells. 2002; 20: 501513.[CrossRef][Medline] [Order article via Infotrieve]
40. Askenasy N, Farkas DL. In vivo imaging studies of the effect of recipient conditioning, donor cell phenotype and antigen disparity on homing of haematopoietic cells to the bone marrow. Br J Haematol. 2003; 120: 505515.[CrossRef][Medline] [Order article via Infotrieve]
41. Sugiyama D, Ogawa M, Hirose I, et al. Erythropoiesis from acetyl LDL incorporating endothelial cells at the preliver stage. Blood. 2003; 101: 47334738.
42. Kihara T, Oshima A, Hirose M, et al. Three-dimensional visualization analysis of in vitro cultured bone fabricated by rat marrow mesenchymal stem cells. Biochem Biophys Res Commun. 2004; 316: 943948.[CrossRef][Medline] [Order article via Infotrieve]
43. Jendelova P, Herynek V, Urdzikova L, et al. Magnetic resonance tracking of transplanted bone marrow and embryonic stem cells labeled by iron oxide nanoparticles in rat brain and spinal cord. J Neurosci Res. 2004; 76: 232243.[CrossRef][Medline] [Order article via Infotrieve]
44. Bai J, Ding W, Yu M, et al. Radionuclide imaging of mesenchymal stem cells transplanted into spinal cord. Neuroreport. 2004; 15: 11171120.[CrossRef][Medline] [Order article via Infotrieve]
45. Niyibizi C, Wang S, Mi Z, et al. The fate of mesenchymal stem cells transplanted into immunocompetent neonatal mice: implications for skeletal gene therapy via stem cells. Mol Ther. 2004; 9: 955963.[CrossRef][Medline] [Order article via Infotrieve]
46. Zhang S, Merritt M, Woessner DE, et al. PARACEST agents: modulating MRI contrast via water proton exchange. Acc Chem Res. 2003; 36: 783790.[CrossRef][Medline] [Order article via Infotrieve]
47. Ferguson B, Wang S, Gray D, et al. Towards functional 3D T-ray imaging. Phys Med Biol. 2002; 47: 37353742.[CrossRef][Medline] [Order article via Infotrieve]
This article has been cited by other articles:
![]() |
H. Leong-Poi Molecular imaging using contrast-enhanced ultrasound: evaluation of angiogenesis and cell therapy Cardiovasc Res, November 1, 2009; 84(2): 190 - 200. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Terrovitis, R. Lautamaki, M. Bonios, J. Fox, J. M. Engles, J. Yu, M. K. Leppo, M. G. Pomper, R. L. Wahl, J. Seidel, et al. Noninvasive quantification and optimization of acute cell retention by in vivo positron emission tomography after intramyocardial cardiac-derived stem cell delivery. J. Am. Coll. Cardiol., October 20, 2009; 54(17): 1619 - 1626. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. D. Adler, A. Bystrup, K. C. Briley-Saebo, V. Mani, W. Young, S. Giovanonne, P. Altman, S. J. Kattman, J. A. Frank, H. J. Weinmann, et al. In Vivo Detection of Embryonic Stem Cell-Derived Cardiovascular Progenitor Cells Using Cy3-Labeled Gadofluorine M in Murine Myocardium J. Am. Coll. Cardiol. Img., September 1, 2009; 2(9): 1114 - 1122. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. A. Kuliszewski, H. Fujii, C. Liao, A. H. Smith, A. Xie, J. R. Lindner, and H. Leong-Poi Molecular imaging of endothelial progenitor cell engraftment using contrast-enhanced ultrasound and targeted microbubbles Cardiovasc Res, September 1, 2009; 83(4): 653 - 662. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Q. Ly, K. Hoshino, I. Pomerantseva, Y. Kawase, R. Yoneyama, Y. Takewa, A. Fortier, S. L. Gibbs-Strauss, C. Vooght, J. V. Frangioni, et al. In vivo myocardial distribution of multipotent progenitor cells following intracoronary delivery in a swine model of myocardial infarction Eur. Heart J., August 17, 2009; (2009) ehp322v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Higuchi, M. Anton, K. Dumler, S. Seidl, J. Pelisek, A. Saraste, A. Welling, F. Hofmann, R. A.J. Oostendorp, B. Gansbacher, et al. Combined Reporter Gene PET and Iron Oxide MRI for Monitoring Survival and Localization of Transplanted Cells in the Rat Heart J. Nucl. Med., July 1, 2009; 50(7): 1088 - 1094. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. J. Blackwood, B. Lewden, R. G. Wells, J. Sykes, R. Z. Stodilka, G. Wisenberg, and F. S. Prato In Vivo SPECT Quantification of Transplanted Cell Survival After Engraftment Using 111In-Tropolone in Infarcted Canine Myocardium J. Nucl. Med., June 1, 2009; 50(6): 927 - 935. [Abstract] [Full Text] [PDF] |
||||
![]() |
Z. Bagi and G. Kaley Where Have All the Stem Cells Gone? Circ. Res., February 13, 2009; 104(3): 280 - 281. [Full Text] [PDF] |
||||
![]() |
C.-P. Chen, S.-H. Liu, J.-P. Huang, J. D. Aplin, Y.-H. Wu, P.-C. Chen, C.-S. Hu, C.-C. Ko, M.-Y. Lee, and C.-Y. Chen Engraftment potential of human placenta-derived mesenchymal stem cells after in utero transplantation in rats Hum. Reprod., January 1, 2009; 24(1): 154 - 165. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Terrovitis, K. F. Kwok, R. Lautamaki, J. M. Engles, A. S. Barth, E. Kizana, J. Miake, M. K. Leppo, J. Fox, J. Seidel, et al. Ectopic Expression of the Sodium-Iodide Symporter Enables Imaging of Transplanted Cardiac Stem Cells In Vivo by Single-Photon Emission Computed Tomography or Positron Emission Tomography J. Am. Coll. Cardiol., November 11, 2008; 52(20): 1652 - 1660. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. L. Franc, P. D. Acton, C. Mari, and B. H. Hasegawa Small-Animal SPECT and SPECT/CT: Important Tools for Preclinical Investigation J. Nucl. Med., October 1, 2008; 49(10): 1651 - 1663. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Gyongyosi, J. Blanco, T. Marian, L. Tron, O. Petnehazy, Z. Petrasi, R. Hemetsberger, J. Rodriguez, G. Font, I. J. Pavo, et al. Serial Noninvasive In Vivo Positron Emission Tomographic Tracking of Percutaneously Intramyocardially Injected Autologous Porcine Mesenchymal Stem Cells Modified for Transgene Reporter Gene Expression Circ Cardiovasc Imaging, September 1, 2008; 1(2): 94 - 103. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. V. Frangioni New Technologies for Human Cancer Imaging J. Clin. Oncol., August 20, 2008; 26(24): 4012 - 4021. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Terrovitis, M. Stuber, A. Youssef, S. Preece, M. Leppo, E. Kizana, M. Schar, G. Gerstenblith, R. G. Weiss, E. Marban, et al. Magnetic Resonance Imaging Overestimates Ferumoxide-Labeled Stem Cell Survival After Transplantation in the Heart Circulation, March 25, 2008; 117(12): 1555 - 1562. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Valina, K. Pinkernell, Y.-H. Song, X. Bai, S. Sadat, R. J. Campeau, T. H. Le Jemtel, and E. Alt Intracoronary administration of autologous adipose tissue-derived stem cells improves left ventricular function, perfusion, and remodelling after acute myocardial infarction Eur. Heart J., November 1, 2007; 28(21): 2667 - 2677. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. A. Jaffer, P. Libby, and R. Weissleder Molecular Imaging of Cardiovascular Disease Circulation, August 28, 2007; 116(9): 1052 - 1061. [Full Text] [PDF] |
||||
![]() |
S. L.M.A. Beeres, F. M. Bengel, J. Bartunek, D. E. Atsma, J. M. Hill, M. Vanderheyden, M. Penicka, M. J. Schalij, W. Wijns, and J. J. Bax Role of Imaging in Cardiac Stem Cell Therapy J. Am. Coll. Cardiol., March 20, 2007; 49(11): 1137 - 1148. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Freyman, G. Polin, H. Osman, J. Crary, M. Lu, L. Cheng, M. Palasis, and R. L. Wilensky A quantitative, randomized study evaluating three methods of mesenchymal stem cell delivery following myocardial infarction Eur. Heart J., May 1, 2006; 27(9): 1114 - 1122. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Cao, S. Lin, X. Xie, P. Ray, M. Patel, X. Zhang, M. Drukker, S. J. Dylla, A. J. Connolly, X. Chen, et al. In Vivo Visualization of Embryonic Stem Cell Survival, Proliferation, and Migration After Cardiac Delivery Circulation, February 21, 2006; 113(7): 1005 - 1014. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2004 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |