Circulation. 2005;112:2592-2601
doi: 10.1161/CIRCULATIONAHA.104.510412
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Previous Version of This Article
Right arrow Correction (v113,pe677)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yue, A. M.
Right arrow Articles by Morgan, J. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yue, A. M.
Right arrow Articles by Morgan, J. M.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*Atrial Fibrillation
Related Collections
Right arrow Electrophysiology

(Circulation. 2005;112:2592-2601.)
© 2005 American Heart Association, Inc.


Arrhythmia/Electrophysiology

Global Dynamic Coupling of Activation and Repolarization in the Human Ventricle

Arthur M. Yue, MRCP; Tim R. Betts, MD, MRCP; Paul R. Roberts, MD, MRCP; John M. Morgan, MD, FRCP

From the Wessex Cardiac Center, Southampton General Hospital, Southampton, UK.

Correspondence to Dr John Morgan, Wessex Cardiac Center, Southampton General Hospital, Mailpoint 46, Southampton SO16 6YD, UK. E-mail jmm{at}cardiology.co.uk

Received September 29, 2004; revision received July 20, 2005; accepted July 25, 2005.


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Background— The ability to determine spatial and dynamic changes in ventricular repolarization may help to understand arrhythmogenic mechanisms in humans. We hypothesized that noncontact mapping could be used to investigate global activation-repolarization coupling in the human ventricle during steady state and premature extrastimulation.

Methods and Results— Activation-recovery intervals (ARIs) determined from reconstructed unipolar electrograms by the Ensite system were analyzed during sinus rhythm, constant pacing, spontaneous ventricular ectopic beats, and premature stimulation at intermediate and short coupling intervals in the left or right ventricle of 13 patients (6 female; mean age, 48 years) without structural myocardial disease. ARIs were measured from 32 sites in each ventricle with the use of a method validated with monophasic action potential recordings and unipolar contact electrograms. Global T-wave distribution was displayed on a 3-dimensional geometry of the ventricle, with polarities opposite to the direction of activation during steady state and premature stimulation. There was a significant inverse correlation between activation times and ARIs during sinus rhythm, ventricular ectopy, and premature stimulation (r=0.72, slope=–0.76, P<0.001). Premature stimuli at short coupling intervals flattened the regression slope compared with sinus rhythm (–0.61 versus –0.81; P=0.05), but the global pattern of repolarization was preserved. In comparison to our method, the Wyatt method of ARI measurement failed to demonstrate significant coupling between activation and repolarization (r=0.34, slope=0.19).

Conclusions— Global, dynamic repolarization mapping of the human ventricle is feasible. An inverse coupling of activation and repolarization during steady state and premature stimulation may preserve electric stability in the normal ventricle.


Key Words: electrophysiology • mapping • repolarization • ventricles


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
The activation-repolarization relationship is crucial in determining ventricular arrhythmogenic mechanisms. Disturbances in the dynamic interplay between activation and repolarization patterns have been linked to the induction and maintenance of ventricular arrhythmias in experimental models of coronary artery disease and the long QT syndrome.1,2 Conversely, an inverse coupling between activation and repolarization could maintain ventricular electric stability during steady states.3–5 However, studies in humans have been limited by the lack of a robust clinical technique to measure instantaneously global changes in cardiac repolarization.

Noncontact mapping can assess global repolarization changes in the human ventricle instantaneously. We have validated the use of activation-recovery intervals (ARIs) reconstructed by noncontact mapping with endocardial monophasic action potential recordings in humans.6 However, T-wave morphologies from reconstructed unipolar electrograms were not specifically validated with contact recordings, and the feasibility of our method to analyze high-density global repolarization data and T-wave distribution on the entire ventricle was not demonstrated. The Wyatt method determines ARI by estimating recovery at the maximum derivative of the T wave,7,8 but it has been shown to underestimate ARIs with positive T-wave polarities.6,9 The use of this approach to estimate global activation-repolarization coupling has not been previously examined.

In this study we investigated the activation-repolarization coupling and endocardial T-wave distribution in the normal ventricle during steady state, spontaneous ventricular ectopic beats, and premature stimuli at intermediate and short coupling intervals using a noncontact mapping method we have developed.6 In addition, we compared this approach with the Wyatt method to examine the activation-repolarization relationship in the human ventricle.


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Patients
Thirteen patients (6 female; mean age, 48 years) who underwent radiofrequency ablation treatment for ventricular or atrial tachycardias guided by noncontact mapping in the Wessex Cardiac Center, Southampton, UK, were enrolled into the study. Twelve patients presented with idiopathic monomorphic ventricular tachycardia, and 1 patient presented with ectopic atrial tachycardia (Table 1). They underwent initial evaluation with clinical history, physical examination, 12-lead ECG, and transthoracic echocardiography. Coronary angiography did not demonstrate clinically significant coronary artery disease, and left ventriculography was normal in all cases. MRI showed no structural abnormality of the right heart. All antiarrhythmic medications were discontinued for 5 half-life periods. The study was performed in the left or right ventricle in the postabsorptive state immediately after successful ablation of ventricular tachycardia or ectopic right atrial tachycardia. In the patient with right atrial tachycardia, right ventricular geometry was constructed after introducing the multielectrode array (MEA) catheter from atrium to ventricle after ablation. All patients had signed written consent before the study. Ethical approval of this study was granted by the Southampton and Southwest Hampshire research ethics committee.


View this table:
[in this window]
[in a new window]
 
TABLE 1. Patient Characteristics

Noncontact Mapping
The technique of noncontact mapping with the use of the Ensite 3000 system (Endocardial Solutions Inc) has been described previously.10,11 The system consists of a 64-MEA mounted on a 7.5-mL inflatable balloon on a 9F catheter, an amplifier system, and a Silicon Graphics workstation. For left ventricular study, the MEA was introduced under fluoroscopic guidance from the left femoral artery via the retrograde transaortic route into the ventricle. For right ventricular study, the MEA was introduced from the left femoral vein. A 7F, 4-mm-tip deflectable ablation catheter (Stinger, Bard) was then introduced into the ventricle by the same route as the MEA catheter. The system calculated the position of the ablation catheter relative to the fixed, known position of the ring electrodes at either end of the MEA. By dragging the ablation catheter tip along the endocardial surface and constantly passing a 5-kHz locator signal to the 2 ring electrodes, a 3-dimensional geometry of the ventricle was determined. The intracavity signals were computed with the use of an inverse Laplace’s equation and projected onto the geometry at >3300 endocardial sites simultaneously. These reconstructed unipolar electrograms were selectively displayed on the workstation screen with the use of manual placement of a cursor on the endocardial geometry. Data were stored on optical discs for offline analysis.

Reconstructed Unipolar Electrograms
Three different morphologies of unipolar electrogram T wave were defined: positive, negative, and biphasic. ARIs were measured by both the Wyatt method and an alternative method to investigate the implications of these 2 approaches on the estimation of global repolarization in a normal ventricle. In the Wyatt method, local ARI was measured between times of dV/dtmin of the QRS and the dV/dtmax of the T wave in the unipolar electrogram of all T-wave morphologies.8 In the alternative method, recovery was determined at the dV/dtmax of the T wave for negative T wave, at the dV/dtmin of the T wave for positive T wave, and at the mean time between dV/dtmax and dV/dtmin for biphasic T wave (Figure 1). Unipolar electrograms with ST-segment elevation without discernible T-wave upstroke were rarely observed in cases in which the pacing electrode was in contact with ventricular endocardium and were excluded from measurement with the Wyatt method. For a T wave with double peak derivatives, recovery time was taken at the mean between 2 peaks. Activation time (AT) was defined as the interval from the onset of QRS or pacing stimulus from surface ECG to the onset of ARI. Repolarization time (RT) was taken as the sum of local activation time and ARI.


Figure 1
View larger version (25K):
[in this window]
[in a new window]
 
Figure 1. Measurement of ARIs from reconstructed unipolar electrograms and their first derivatives (dV/dt). Wyatt (w) and alternative (a) methods used for determining ARIs for negative (I), positive (II), and biphasic (III) T waves are shown.

Premature Stimulation
Constant right ventricular pacing (S1) with a bipolar woven catheter (Bard EP Inc) at the right ventricular apex was performed for 2 minutes at cycle lengths of 400 ms with a pulse width of 2-ms duration and stimulus strength of twice diastolic threshold. After steady state has been established, an extrastimulus (S2) was introduced at every 10-beat cycle. A "short" S1-S2 coupling interval was defined as the shortest interval that resulted in S2 capture. An "intermediate" S1-S2 coupling interval was defined as 75% of total S1-S2 shortening from steady state to S2 refractoriness.

Contact Unipolar Recordings
In 2 patients (12 and 13), reconstructed T-wave morphologies were validated with contact unipolar electrogram recordings at multiple endocardial sites. Contact unipolar electrograms were measured between the tip of the ablation catheter and the most proximal reference electrode (20 cm from the tip) of the MEA catheter by jump connections in the breakout box. Thus, the same reference electrode was used for determining contact and reconstructed unipolar electrograms by the Ensite system. The EnGuide locator signal was directed through the ablation catheter tip to display its location on the geometry. A total of 117 recordings at 39 different ventricular sites were made (3 consecutive beats analyzed from each site) during sinus rhythm, spontaneous ventricular ectopy, and right ventricular apical pacing.

Data Analysis
Data were analyzed with the Silicon Graphics workstation with the use of the standard Precision software (version 4.0). Measurements were made manually from electrograms displayed on a Silicon Graphics color monitor at 200 mm/s resolution. The use of electronic calipers from the workstation allows timings of activation and repolarization to be determined to an accuracy of 1 ms.

Validation of T-Wave Morphology
Three consecutive paired recordings were selected from each site for comparison, including abrupt changes in local T-wave morphology caused by ventricular ectopic beats or pacing (Figure 2). Recording bandwidth was set at 0.1 to 300 Hz for contact and unipolar electrogram recordings. Simultaneous voltage data from contact and unipolar electrogram T waves were exported for cross-correlation analysis. Differences in timing between unipolar electrograms and contact electrograms were measured. The distance of each sampling site of the geometry from the center of the MEA was documented with the use of the workstation algorithm.


Figure 2
View larger version (12K):
[in this window]
[in a new window]
 
Figure 2. Validation of reconstructed T-wave morphologies. Contact unipolar (UNI) and reconstructed virtual electrograms are taken from the same right ventricular site (closed arrow) during sinus rhythm and right ventricular apical pacing. Note that ventricular apical pacing (open arrow) induces a change in T-wave morphology in the contact electrogram that is matched by the corresponding change in the virtual electrogram. T-wave data from contact and virtual electrograms as marked by the calipers are exported for cross-correlation analysis.

Measurement of Global ARIs
A custom-designed template was used to display the unipolar electrogram and its first derivative (dV/dt) from 2 endocardial sites at a time. A total of 32 sites were analyzed from each ventricle, with 2 sites 1 cm apart from each of 16 predefined segments in the left or right ventricular geometry (Figure 3). Samples were evenly selected from the entire ventricle on the basis of anatomic grounds and not on electrogram appearances. For timing measurement of the first derivatives of the QRS and T waves, filter bandwidth was selected at 0.1 to 25 Hz.6 Global dispersion of RT was calculated by the range of RTs within a map (maximum RT–minimum RT). Adjacent dispersion of RT was defined as the difference between 2 adjacent sites (1 cm apart) within each segment of the ventricle. Sinus rhythm, ventricular ectopy, and pacing recordings were randomly selected for analysis.


Figure 3
View larger version (19K):
[in this window]
[in a new window]
 
Figure 3. Sixteen regional segments in both left and right ventricles (RV) from which data were sampled. PV indicates location of pulmonary valve.

T-Wave Maps
Endocardial T-wave distribution was displayed as colors on the geometry by using the isochronal map algorithm, with detection sensitivity set at maximum and the filter bandwidth set at 0.1 to 300 Hz. After the "static map" option was selected, calipers were placed from the onset to the end of a T wave on the surface ECG. Because the algorithm determined local timings from the peak dV/dtmin of the selected waveforms, sites with negative and biphasic unipolar electrogram T waves, which had earlier peak dV/dtmin, could be separated from sites with positive T waves, which had much later peak dV/dtmin. Accordingly, areas with negative and biphasic T waves were displayed in yellow to red and positive T waves in blue on the isochronal map. Therefore, the spatial distribution of different T-wave morphologies for any selected beat could be displayed on the geometry.

Statistical Analysis
Continuous data that were approximately normally distributed were presented as mean±SD. T-wave morphologies for paired unipolar electrograms and contact electrograms were compared by cross-correlation analysis.10 The correlation between activation time and ARI or RT for each map was calculated with the use of Pearson’s correlation coefficient test and simple linear regression analysis. Continuous data that were not approximately normally distributed were compared with the Wilcoxon matched pair signed rank test. Median regression slopes during sinus rhythm and premature stimulation were compared with the Wilcoxon matched pair signed rank test paired by patient and state. Thirty-two sites from each ventricle were analyzed to detect a correlation coefficient of 0.60 with 90% power. A probability value of <0.05 was considered statistically significant.


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowReferences
 
Validation of T-Wave Morphology
A total of 117 recordings of paired contact and reconstructed electrograms were compared. The overall mean correlation of T-wave morphology was 0.97±0.06, with a difference in timing between unipolar electrograms and contact electrograms of 4±14 ms. Correlation was statistically significant for all 3 T-wave morphologies. Cross-correlation coefficients were 0.98 (P<0.001) for negative T wave, 0.96 (P<0.001) for positive T wave, and 0.96 (P<0.001) for biphasic T wave. The mean distance of sampling sites from the center of the MEA was 24±5 mm.

Endocardial T-Wave Distribution
A total of 54 ventricular maps were constructed from 13 patients, of which there were 13 from sinus rhythm, 12 from ventricular ectopy, 12 from constant ventricular pacing, 8 during intermediate premature stimuli, and 9 during short premature stimuli. In 45 of 54 maps, T-wave morphologies were arranged in a spatially predictable manner, with positive T waves located in areas of earliest endocardial activation, negative T waves in regions of latest activation, and biphasic T waves in between. The global pattern of T-wave distribution was consistent during sinus rhythm (Figure 4), spontaneous ventricular ectopic beats (Figure 5), constant pacing, and extrastimulation (Figure 6). Repolarization distribution was preserved in the global ventricle, and changes in T-wave morphology at short premature coupling intervals only occurred within border regions of T-wave transition (Figure 6). In the 9 maps with atypical distributions, 4 maps showed only positive T waves, 2 maps showed only negative T waves, and 3 maps showed no relationship between T-wave morphology and activation times.


Figure 4
View larger version (33K):
[in this window]
[in a new window]
 
Figure 4. Isochronal maps of the left ventricle during sinus rhythm in patient 1 (left anterior oblique view). Activation map (A) and T wave map (B) during repolarization (positive T waves in blue; negative and biphasic T waves in yellow to red) are shown. Positive T waves are located at sites of earliest activation, and negative T waves are located at sites of latest activation. Ant indicates anterior; Lat, lateral.


Figure 5
View larger version (28K):
[in this window]
[in a new window]
 
Figure 5. Isochronal maps of the left ventricle during spontaneous ventricular ectopic activity in patient 1 (anterior-posterior view). Activation map (A) and T wave map during repolarization (B) (positive T waves in blue; negative and biphasic T waves in yellow to red) are shown. Positive T waves are located at sites of earliest activation, and negative T waves are located at sites of latest activation. Ant indicates anterior; AV, aortic valve.


Figure 6
View larger version (37K):
[in this window]
[in a new window]
 
Figure 6. Isochronal maps of the right ventricle during constant pacing and after a premature extrastimulus in patient 7 (anterior posterior view). An isochronal activation map during constant right ventricular apical pacing is shown (A). T-wave maps are shown during constant pacing (B) and premature stimulus (C) (positive T waves in blue; negative and biphasic T waves in yellow to red). Virtual electrogram 3 is selected at the border region to demonstrate a change in T-wave morphology from biphasic to positive after a premature stimulus (arrow). However, the global pattern of T-wave distribution is preserved, with positive T waves located at sites of earliest activation and negative T waves located at sites of latest activation. RVOT indicates right ventricular outflow tract; RVA, right ventricular apex; and TV, tricuspid valve.

Global Activation-Repolarization Coupling
Of the 1728 measurements of ARIs made from 54 maps during steady states and extrastimuli, 43 (2%) were excluded from analysis because of flat or complex T waves, and an additional 21 (1%) were specifically excluded from Wyatt method measurement because of ST elevations in which the upstroke of T wave could not be defined.

With the use of our alternative method for ARI determination in both ventricles, ARIs were found to correlate inversely and linearly with ATs during sinus rhythm, ventricular ectopic beats, constant right ventricular pacing at 400-ms drive cycle lengths, and premature stimulation (Figure 7). The inverse coupling between activation and repolarization could be demonstrated even in maps with uniform or atypical T-wave distribution. The overall correlation was 0.72, with a regression slope of –0.76 (P<0.001) (Table 2). The mean intermediate S1-S2 coupling interval during premature stimulation was 260±17 ms, and mean short S1-S2 interval was 204±22 ms. During intermediate and short premature stimulations, not only was the inverse activation-relationship maintained, but there was also a significant trend toward progressive flattening of regression slope with short premature extrastimuli compared with sinus rhythm (–0.61 versus –0.81; P=0.05) (Figure 8).


Figure 7
View larger version (16K):
[in this window]
[in a new window]
 
Figure 7. A, Relationship between AT and ARI. A typical example is taken from patient 7 during constant ventricular pacing. A significant inverse correlation is demonstrated with the alternative method (closed circles; slope=–1.03, r=0.92, P<0.001) but not the Wyatt method (open triangles; slope=0.27, r=0.28, P=0.06). B, Relationship between AT and total RT. RTs estimated by the alternative method (closed circles) are constant over the global endocardium (range, 34 ms). RTs measured by the Wyatt method (open triangles) are heterogeneous at short AT (range, 76 ms).


View this table:
[in this window]
[in a new window]
 
TABLE 2. Activation-Repolarization Relationship During Steady State and Premature Stimulation (Alternative Method)


Figure 8
View larger version (9K):
[in this window]
[in a new window]
 
Figure 8. ARI regression slopes during steady state, ventricular ectopy, and premature stimulation for all patients (box and whisker plot shows median, interquartile range, and extreme values). SR indicates sinus rhythm; VE, ventricular ectopy; Pace, constant right ventricular pacing; and R1 and R2, premature stimuli at intermediate and short coupling intervals, respectively. *P=0.05.

Dispersion of Total Repolarization Times
Global dispersion of repolarization during steady state was 45 ms in sinus rhythm and 49 ms during constant ventricular pacing. Similar values were found for ventricular ectopic beats (43 ms) and premature stimulation at intermediate coupling intervals (47 ms), but global dispersion was increased by premature stimulation at short coupling intervals to 50 ms (Table 2). Adjacent dispersion of repolarization was small and was not altered by premature stimulation with an overall mean of 6±3 ms.

Comparison of Wyatt Method With Alternative Method
If ARIs were measured with the Wyatt method for the global ventricle, the activation-repolarization relationship was not statistically significant (r=0.34, 52% of slopes with P<0.05) in comparison to the inverse correlation with the use of the alternative method (r=0.72, 91% of slopes with P<0.001) during steady state and premature stimulation (Table 3). The use of the Wyatt method was also associated with greater global dispersion of repolarization times compared with the alternative method (99 versus 47 ms; P<0.001) because of differences in repolarization times in regions with positive T waves (Figure 7).


View this table:
[in this window]
[in a new window]
 
TABLE 3. Comparison Between Wyatt and Alternative Methods


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowReferences
 
The close correlation of reconstructed unipolar T-wave morphology with contact electrograms in this report, combined with the excellent correlation between reconstructed ARIs and monophasic action potential durations,6 demonstrates that noncontact mapping is a valid technique for quantifying ventricular repolarization and endocardial T-wave distribution in humans.

Global Distribution of T-Wave Polarities
Unipolar T-wave polarities are opposite to the deflection resulting from the direction of activation12; hence, the positive T waves are in areas of earliest activation, and negative T waves are at sites of latest activation. This finding has been shown previously during steady states in the dog heart with the use of transmural electrodes,13,14 in the swine endocardium with the use of sequential contact recordings,4 and in the human epicardium with the use of contact electrodes.9 We have demonstrated these repolarization gradients in the human endocardium not only in steady state but also after premature stimulation. A transmural gradient may also exist during sinus rhythm, with T waves being positive in the epicardium and negative in the endocardium in the canine heart.14 These transventricular and transmural potential gradients are used to predict the directionality of ventricular repolarization from areas with positive to negative potentials. Because our technique is validated with endocardial contact recordings, T-wave distribution maps could be used to analyze instantaneous spatial forces of repolarization in the human ventricle.

Inverse Coupling of Activation and Repolarization
The data presented in this study suggest that activation is inversely coupled to repolarization in the normal ventricle, so that areas activated the earliest are associated with longer local action potential durations than areas activated the latest. Our findings concur with recent reports of global repolarization mapping in the swine and human ventricles.3–5 Franz et al3 demonstrated such an inverse relationship using monophasic action potential recordings in the human ventricle during sinus rhythm and further showed that the epicardium activated later but repolarized earlier than the endocardium, which accounted for the T-wave concordance of the normal ECG. Gepstein et al4 constructed high-density repolarization maps of the swine left ventricle using electroanatomic mapping. They found that during both sinus rhythm and right ventricular pacing, ARIs were the longest near the area of earliest activation and gradually shortened with increasing distance from this site. Yuan et al5 also found an inverse linear relationship between local activation times and monophasic action potential durations in one patient during ventricular ectopic beats and another patient during ventricular tachycardia.

Electrotonic interaction is a potential mechanism that may relate activation to repolarization sequence over the global ventricle. Gap junction proteins may mediate the transfer of action potential between adjacent myocytes15 over extended distances.16 Activation wave fronts from ectopic or paced rhythms, which preferentially utilize intermyocyte conduction rather than specialized conduction systems, may particularly be influenced by this phenomenon. As a result of electrotonic interaction, transverse or longitudinal excitation propagation along the long axis of ventricular fibers determines the spatial gradient of ventricular repolarization.17 However, when nonuniform activation is simulated by introducing anisotropic conductivities, marked spatial dispersion of repolarization is induced.18 There is also evidence to suggest that repolarization currents applied during repolarization may shorten the local action potential.3,12 Therefore, an upstream cell that repolarizes earlier than a downstream cell may, through electrotonic interaction, shorten the action potential duration of the downstream cell. If this pattern were uniformly maintained over the entire ventricle, an inverse linear relationship between activation and repolarization times could be formed.

Global Dispersion of Repolarization
It is debated whether repolarization in the regions with latest activation completes before or after areas of earliest activation, as reflected by the slope of linear regression for action potential duration against activation time. Were the mean regression slope to be more negative than –1, as demonstrated by Franz et al3 at 5 to 11 recording sites, then repolarization would complete earliest in regions of latest activation. If the regression slope were more positive than –1, as shown in our study (–0.76) or others that also employed 3-dimensional mapping technologies,4,5 the converse would be true. In either case, activation is correlated inversely with repolarization, which may be a mechanism whereby spatial dispersion of repolarization is minimized in the normal ventricle. A progressive and homogeneous reduction of local ARI with increasing distance and activation delay from the site of earliest activation may minimize the overall dyssynchrony of ventricular repolarization times. Thus, the median global dispersion of repolarization times during steady state and premature stimulation in our patients ranges from 43 to 50 ms, which is consistent with values obtained from prior studies in human subjects without structural or repolarization abnormalities that range from 30 to 60 ms.3,19–21

Spatial dispersion of ventricular repolarization of a much greater magnitude ranging from 90 to 190 ms is frequently required for the induction of ventricular arrhythmias under clinical conditions.21,22

Coupling of Activation and Repolarization During Premature Stimulation
We have shown that the global pattern of T-wave distribution and activation-repolarization coupling gradient are both preserved during premature stimulation and that this effect is instantaneous, occurring after a single extrastimulus or ventricular ectopic beat. This inverse coupling appears to maintain uniformity of spatial and temporal repolarization patterns and electric stability in the normal heart during both steady state and spontaneous ectopic activity. Extrastimuli at progressive proximity to the preceding beat might induce ventricular arrhythmias by flattening the regression slope and increasing global dispersion of repolarization. However, we have not observed any reversal of the action potential gradients and T-wave morphologies at short coupling intervals, as demonstrated by optical mapping studies on the guinea pig epicardium.23 We note in our patients that changes in T-wave morphology sometimes occur during short premature stimulation but are limited to small border regions, with the overall global distribution maintained. Therefore, it is possible that the disparity is related to optical mapping data being sampled from a relatively small area or the difference between epicardial and endocardial response to extrastimulation.

Activation-repolarization coupling during single ectopic beats or premature stimulation in our patients without structural heart disease probably represents a "primary" effect of depolarization modulating its own repolarization gradient.24 As such, there is no prior electric remodeling, and the polarities of T wave remain opposite to the direction of activation. However, there is a trend toward a lesser negative regression slope during premature stimulation compared with sinus rhythm, which may suggest an instantaneous adaptation effect. If abnormal activation were to persist, electric remodeling could be induced and manifested after return to sinus rhythm as "secondary" abnormal repolarization pattern and loss of normal activation-repolarization coupling.24,25

Methodology of Determining Repolarization From Unipolar Electrograms
The Wyatt approach for determining ARIs is based on theoretical derivation26 and has undergone systematic validation.8,27 However, a number of studies have reported that the Wyatt method may underestimate ARIs of the positive T-wave polarity,4,6,9 and the error may be more pronounced during premature stimulation. Our study shows that by using the Wyatt method, the relationship between activation and repolarization is altered with loss of linearity, inverse correlation, and statistical significance. Furthermore, global dispersion of repolarization is greater when measured by the Wyatt method compared with the alternative method. It is our opinion that this is an overestimation of dispersion of repolarization, but the implications of the differences between the 2 methods require further evaluation.

Clinical Implications
Dispersion of refractoriness has been shown in experimental studies to favor the development of reentry ventricular arrhythmias,2,28,29 but its role in humans is not yet established. We have shown that it is feasible to quantify T-wave distribution and global activation-repolarization coupling during steady state and premature stimulation. A tight inverse coupling between activation and repolarization in the global heart could protect the normal heart from developing ventricular arrhythmias in the presence of extrastimulation at short coupling intervals. On the contrary, disturbances of this coupling by structural heart disease or disorders of ion channels may be intensely arrhythmogenic. Our technique can be used to investigate arrhythmic mechanisms and identify risk markers for patients with these disease processes. The ability of noncontact mapping to display high-density global distribution of T waves could also be valuable in future studies of cardiac memory or electric remodeling.

Limitations
Although T-wave mapping provides a visual representation of T-wave distribution in a 3-dimensional geometry, the color scales do not reflect local repolarization timings. However, an algorithm can be developed on the basis of the aforementioned criteria to generate isochronal maps of global repolarization times. For practical and ethical reasons, our study has been conducted in one ventricle per patient, and therefore true transventricular repolarization gradients could not be measured directly. Our measurement methods and data are comparable with previous studies in which contact catheter techniques were used, but in the absence of a gold standard for measuring global and instantaneous ventricular repolarization, our data do not disprove the validity of the Wyatt approach.

Conclusions
It is feasible to use noncontact mapping to study global repolarization dynamics in the human ventricle. In the normal heart, this technique has advanced the understanding that during premature stimulation, activation and repolarization are tightly coupled to preserve electric homogeneity.


*    Acknowledgments
 
This study was supported by research funding from Endocardial Solutions, St Jude Medical, and the Wessex Cardiac Electrophysiology Research Fund to Dr Yue.

Disclosure

Drs Yue and Betts have previously participated in scientific studies for Endocardial Solutions.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*References
 
1. Gough WB, Mehra R, Restivo M, Zeiler RH, el Sherif N. Reentrant ventricular arrhythmias in the late myocardial infarction period in the dog, 13: correlation of activation and refractory maps. Circ Res. 1985; 57: 432–442.[Abstract/Free Full Text]

2. el Sherif N, Caref EB, Yin H, Restivo M. The electrophysiological mechanism of ventricular arrhythmias in the long QT syndrome: tridimensional mapping of activation and recovery patterns. Circ Res. 1996; 79: 474–492.[Abstract/Free Full Text]

3. Franz MR, Bargheer K, Rafflenbeul W, Haverich A, Lichtlen PR. Monophasic action potential mapping in human subjects with normal electrocardiograms: direct evidence for the genesis of the T wave. Circulation. 1987; 75: 379–386.[Abstract/Free Full Text]

4. Gepstein L, Hayam G, Ben Haim SA. Activation-repolarization coupling in the normal swine endocardium. Circulation. 1997; 96: 4036–4043.[Abstract/Free Full Text]

5. Yuan S, Kongstad O, Hertervig E, Holm M, Grins E, Olsson B. Global repolarization sequence of the ventricular endocardium: monophasic action potential mapping in swine and humans. Pacing Clin Electrophysiol. 2001; 24: 1479–1488.[CrossRef][Medline] [Order article via Infotrieve]

6. Yue AM, Paisey JR, Robinson S, Betts TR, Roberts PR, Morgan JM. Determination of human ventricular repolarization by noncontact mapping: validation with monophasic action potential recordings. Circulation. 2004; 110: 1343–1350.[Abstract/Free Full Text]

7. Wyatt RF, Burgess MJ, Evans AK, Lux RL, Abildskov JA, Tsutsumi T. Estimation of ventricular transmembrane action potential durations and repolarization times from unipolar electrograms. Am J Cardiol. 1981; 47: 488.

8. Haws CW, Lux RL. Correlation between in vivo transmembrane action potential durations and activation-recovery intervals from electrograms: effects of interventions that alter repolarization time. Circulation. 1990; 81: 281–288.[Abstract/Free Full Text]

9. Chen PS, Moser KM, Dembitsky WP, Auger WR, Daily PO, Calisi CM, Jamieson SW, Feld GK. Epicardial activation and repolarization patterns in patients with right ventricular hypertrophy. Circulation. 1991; 83: 104–118.[Abstract/Free Full Text]

10. Schilling RJ, Peters NS, Davies DW. Simultaneous endocardial mapping in the human left ventricle using a noncontact catheter: comparison of contact and reconstructed electrograms during sinus rhythm. Circulation. 1998; 98: 887–898.[Abstract/Free Full Text]

11. Gornick CC, Adler SW, Pederson B, Hauck J, Budd J, Schweitzer J. Validation of a new noncontact catheter system for electroanatomic mapping of left ventricular endocardium. Circulation. 1999; 99: 829–835.[Abstract/Free Full Text]

12. Hoffman BF. Electrotonic modulation of the T wave. Am J Cardiol. 1982; 50: 361–362.[CrossRef][Medline] [Order article via Infotrieve]

13. Spach MS, Barr RC. Analysis of ventricular activation and repolarization from intramural and epicardial potential distributions for ectopic beats in the intact dog. Circ Res. 1975; 37: 830–843.[Abstract/Free Full Text]

14. Spach MS, Barr RC. Ventricular intramural and epicardial potential distributions during ventricular activation and repolarization in the intact dog. Circ Res. 1975; 37: 243–257.[Abstract/Free Full Text]

15. Lin X, Veenstra RD. Action potential modulation of connexin40 gap junctional conductance. Am J Physiol. 2004; 286: H1726–H1735.

16. Gaudesius G, Miragoli M, Thomas SP, Rohr S. Coupling of cardiac electrical activity over extended distances by fibroblasts of cardiac origin. Circ Res. 2003; 93: 421–428.[Abstract/Free Full Text]

17. Osaka T, Kodama I, Tsuboi N, Toyama J, Yamada K. Effects of activation sequence and anisotropic cellular geometry on the repolarization phase of action potential of dog ventricular muscles. Circulation. 1987; 76: 226–236.[Abstract/Free Full Text]

18. Zubair I, Pollard AE, Spitzer KW, Burgess MJ. Effects of activation sequence on the spatial distribution of repolarization properties. J Electrocardiol. 1994; 27: 115–127.[CrossRef][Medline] [Order article via Infotrieve]

19. Kongstad O, Yuan S, Hertervig E, Holm M, Grins E, Olsson B. Global and local dispersion of ventricular repolarization: endocardial monophasic action potential mapping in swine and humans by using an electro-anatomical mapping system. J Electrocardiol. 2002; 35: 159–167.[Medline] [Order article via Infotrieve]

20. Malik M, Batchvarov VN. Measurement, interpretation and clinical potential of QT dispersion. J Am Coll Cardiol. 2000; 36: 1749–1766.[Abstract/Free Full Text]

21. Morgan JM, Cunningham D, Rowland E. Dispersion of monophasic action potential duration: demonstrable in humans after premature ventricular extrastimulation but not in steady state. J Am Coll Cardiol. 1992; 19: 1244–1253.[Abstract]

22. Yuan S, Wohlfart B, Olsson SB, Blomstrom-Lundqvist C. The dispersion of repolarization in patients with ventricular tachycardia: a study using simultaneous monophasic action potential recordings from two sites in the right ventricle. Eur Heart J. 1995; 16: 68–76.[Abstract/Free Full Text]

23. Laurita KR, Girouard SD, Rosenbaum DS. Modulation of ventricular repolarization by a premature stimulus: role of epicardial dispersion of repolarization kinetics demonstrated by optical mapping of the intact guinea pig heart. Circ Res. 1996; 79: 493–503.[Abstract/Free Full Text]

24. Rosenbaum MB, Blanco HH, Elizari MV, Lazzari JO, Davidenko JM. Electrotonic modulation of the T wave and cardiac memory. Am J Cardiol. 1982; 50: 213–222.[CrossRef][Medline] [Order article via Infotrieve]

25. Rosen MR, Binah O, Marom S. Cardiac memory and cortical memory:do learning patterns in neural networks impact on cardiac arrhythmias? Circulation. 2003; 108: 1784–1789.[Abstract/Free Full Text]

26. Steinhaus BM. Estimating cardiac transmembrane activation and recovery times from unipolar and bipolar extracellular electrograms: a simulation study. Circ Res. 1989; 64: 449–462.[Abstract/Free Full Text]

27. Millar CK, Kralios FA, Lux RL. Correlation between refractory periods and activation-recovery intervals from electrograms: effects of rate and adrenergic interventions. Circulation. 1985; 72: 1372–1379.[Abstract/Free Full Text]

28. Han J, Moe GK. Nonuniform recovery of excitability in ventricular muscle. Circ Res. 1964; 14: 44–60.[Abstract/Free Full Text]

29. Kuo CS, Munakata K, Reddy CP, Surawicz B. Characteristics and possible mechanism of ventricular arrhythmia dependent on the dispersion of action potential durations. Circulation. 1983; 67: 1356–1367.[Abstract/Free Full Text]




This article has been cited by other articles:


Home page
EuropaceHome page
R. J. Selvaraj, A. M. Suszko, A. Subramanian, K. Nanthakumar, and V. S. Chauhan
Adrenergic stimulation increases repolarization dispersion and reduces activation-repolarization coupling along the RV endocardium of patients with cardiomyopathy
Europace, November 1, 2009; 11(11): 1529 - 1535.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
P.D. Lambiase, A.K. Ahmed, E.J. Ciaccio, R. Brugada, E. Lizotte, S. Chaubey, R. Ben-Simon, A.W. Chow, M.D. Lowe, and W.J. McKenna
High-Density Substrate Mapping in Brugada Syndrome: Combined Role of Conduction and Repolarization Heterogeneities in Arrhythmogenesis
Circulation, July 14, 2009; 120(2): 106 - 117.
[Abstract] [Full Text] [PDF]


Home page
Circ Arrhythm ElectrophysiolHome page
B. Hanson, P. Sutton, N. Elameri, M. Gray, H. Critchley, J. S. Gill, and P. Taggart
Interaction of Activation-Repolarization Coupling and Restitution Properties in Humans
Circ Arrhythm Electrophysiol, April 1, 2009; 2(2): 162 - 170.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
G. Buckberg, J. I.E. Hoffman, A. Mahajan, S. Saleh, and C. Coghlan
Cardiac Mechanics Revisited: The Relationship of Cardiac Architecture to Ventricular Function
Circulation, December 9, 2008; 118(24): 2571 - 2587.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
S. E. Ahlberg, A. M. Yue, N. D. Skadsberg, P. R. Roberts, P. A. Iaizzo, and J. M. Morgan
Investigation of pacing site-related changes in global restitution dynamics by non-contact mapping
Europace, January 1, 2008; 10(1): 40 - 45.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
P. Colli Franzone, L. F. Pavarino, S. Scacchi, and B. Taccardi
Monophasic action potentials generated by bidomain modeling as a tool for detecting cardiac repolarization times
Am J Physiol Heart Circ Physiol, November 1, 2007; 293(5): H2771 - H2785.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Previous Version of This Article
Right arrow Correction (v113,pe677)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yue, A. M.
Right arrow Articles by Morgan, J. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yue, A. M.
Right arrow Articles by Morgan, J. M.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*Atrial Fibrillation
Related Collections
Right arrow Electrophysiology