Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2006;114:e485-e486
doi: 10.1161/CIRCULATIONAHA.105.604900
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Piazza, G.
Right arrow Articles by Zimetbaum, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Piazza, G.
Right arrow Articles by Zimetbaum, P. J.
Related Collections
Right arrow Echocardiography
Right arrow Other diagnostic testing
Right arrowRelated Article

(Circulation. 2006;114:e485-e486.)
© 2006 American Heart Association, Inc.


Images in Cardiovascular Medicine

An Unusual Explanation for Episodic Dyspnea

Gregory Piazza, MD; Joseph P. Carrozza, Jr, MD; Peter J. Zimetbaum, MD

From the Cardiovascular Division, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Mass.

Correspondence to Gregory Piazza, MD, Cardiovascular Division, Beth Israel Deaconess Medical Center, One Deaconess Rd, Baker 4, Boston, MA 02215. E-mail gpiazza{at}bidmc.harvard.edu

An 88-year-old woman with a nonischemic cardiomyopathy, severe kyphoscoliosis, and an implantable cardiac defibrillator presented from her nursing home with dyspnea and hypoxemia. She had several recent hospitalizations for similar symptoms that were attributed to heart failure and pneumonia. On the day of presentation, she had severe dyspnea while eating breakfast. In the emergency department, her physical examination was remarkable for an oxygen saturation of 94% on 100% nonrebreather mask, which was minimally changed from baseline pulse oximetry on room air. Laboratory evaluation was notable for hypoxemia, with a pO2 of 61 mm Hg. ECG and chest radiography were unremarkable. Chest computed tomography with contrast revealed a dilated thoracic aorta without dissection and no evidence of pulmonary embolism. A transthoracic echocardiogram demonstrated moderate global left ventricular hypokinesis, preserved right ventricular systolic function, normal estimated pulmonary artery pressures, mild aortic regurgitation, and an aneurysmal interatrial septum with right-to-left shunt on color Doppler. The patient continued to have episodic dyspnea with desaturation, and a cardiologist was consulted. During the consultation, her oxygen saturation decreased to 67% in the upright position, with or without supplemental oxygen, and increased to 94% in the recumbent position. A bedside transthoracic echocardiogram revealed a resting right-to-left shunt in the recumbent position that increased in the upright position (Figure 1). These findings were consistent with platypnea-orthodeoxia. Transesophageal echocardiography revealed a patent foramen ovale. She subsequently underwent cardiac catheterization with successful transcatheter closure of the patent foramen ovale (Figure 2). After closure, her oxygen saturation remained greater than 95% in both the recumbent and upright positions. Whereas before closure, passage of agitated saline contrast from the right atrium to the left atrium at rest was shown by transthoracic echocardiography, no passage of contrast was noted afterward (Figure 3). After device closure, the patient was observed eating dinner in the upright position without dyspnea or desaturation.


Figure 1177767
View larger version (35K):
[in this window]
[in a new window]
 
Figure 1. Transthoracic echocardiogram (apical 5-chamber view) demonstrating that the right-to-left shunt (arrow) increased on position change from supine to upright. Simultaneous pulse oximetry revealed a decrease in the oxygen saturation from 95% to 71% on upright positioning. AR indicates aortic regurgitation; LA, left atrium; and LV, left ventricle.


Figure 2177767
View larger version (172K):
[in this window]
[in a new window]
 
Figure 2. No evidence of right-to-left shunting of contrast was demonstrated after device release. RA indicates right atrium; LA, left atrium.


Figure 3177767
View larger version (62K):
[in this window]
[in a new window]
 
Figure 3. Transthoracic echocardiogram (apical 5-chamber view) performed during the procedure demonstrating passage of agitated saline from the right atrium to the left atrium before but not after device closure. LA indicates left atrium; LV, left ventricle.


*    Acknowledgments
 
Disclosures

None.


*    Footnotes
 
Guest Editor for this article was Michael J. Landzberg, MD.


Related Article:

Issue Highlights
Circulation 2006 114: 1133. [Full Text]




This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Piazza, G.
Right arrow Articles by Zimetbaum, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Piazza, G.
Right arrow Articles by Zimetbaum, P. J.
Related Collections
Right arrow Echocardiography
Right arrow Other diagnostic testing
Right arrowRelated Article