Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 2008;118:e101-e102
doi: 10.1161/CIRCULATIONAHA.107.762096
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Data Supplement
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kim, J.-S.
Right arrow Articles by Jang, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kim, J.-S.
Right arrow Articles by Jang, Y.
Related Collections
Right arrow Catheter-based coronary interventions: stents
Right arrow Coronary imaging: angiography/ultrasound/Doppler/CC
Right arrow Acute coronary syndromes
Right arrow Acute myocardial infarction

(Circulation. 2008;118:e101-e102.)
© 2008 American Heart Association, Inc.


Images in Cardiovascular Medicine

Catastrophic Thrombus Formation During Optical Coherence Tomography

Jin-Sun Kim, MD; Jung-Sun Kim, MD, PhD; Eui-Young Choi, MD, PhD; Donghoon Choi, MD, PhD; Yangsoo Jang, PhD

From the Division of Cardiology, Yonsei Cardiovascular Center, Yonsei University College of Medicine, Seoul, South Korea.

Correspondence to Jung-Sun Kim, MD, Division of Cardiology, Yonsei Cardiovascular Center, Yonsei University College of Medicine, 120–752, Shinchondong, Seodaemun-gu, Seoul, South Korea, E-mail kjs1218{at}yuhs.ac

A 71-year-old patient underwent follow-up coronary angiography to assess the patency of a left anterior descending (LAD) artery stent. Seven months previously, she had received percutaneous coronary intervention at the LAD because of anterior wall ST-elevation myocardial infarction. At that time, 2 drug-eluting stents (Cypher 3.0x28 mm and Cypher 2.75x28 mm) were inserted at the proximal and distal LAD. After percutaneous coronary intervention, she had taken 100 mg of aspirin, 75 mg of clopidogrel, and 200 mg of cilostazol daily. Coronary angiography at 7 months follow-up was performed as part of the protocol for the optical coherence tomography (OCT) registry. The follow-up coronary angiography revealed patent stents implanted in the LAD (Figure 1A). We also performed intravascular ultrasound (IVUS) and OCT to evaluate neointimal coverage of the drug-eluting stents. IVUS revealed that the stents were partially covered with neointima without any evidence of thrombus during IVUS imaging (online-only Data Supplement Movie I). Subsequently, we performed OCT, which clearly illustrated partial neointimal coverage of stent struts. But during the OCT procedure, multiple thrombi formation were observed (Figure 2 and online-only Data Supplement Movie II). Coronary angiography immediately after OCT revealed thrombotic total occlusion of the distal LAD (Figure 1B and online-only Data Supplement Movie III). Therefore we immediately performed thrombi suction with a Thrombuster catheter (Kaneka Medics, Osaka, Japan). However, the thrombi were not completely cleared, with only partial recovery of the distal flow (online-only Data Supplement Movie IV). Fortunately, no significant deterioration occurred in the ECG or in the patient’s condition after the procedure. The patient recovered uneventfully.


Figure 1190264
View larger version (75K):
[in this window]
[in a new window]

 
Figure 1. A, Follow-up coronary angiography revealed patent stents previously inserted at proximal and distal LAD artery. B, After OCT imaging, total occlusion of distal LAD was observed on coronary angiography (arrow).


Figure 2190264
View larger version (47K):
[in this window]
[in a new window]

 
Figure 2. New thrombi were detected during evaluation of the distal stent with OCT.

OCT is an in vivo light-based imaging modality for evaluating the coronary artery microstructure.1 Because the resolution of OCT imaging is higher than that of IVUS, its application in research is expanding.2,3 In particular, attempts to detect vulnerable plaques in vivo with OCT imaging and studies of the delicate interaction between vessel wall and stent strut, as well as of neointima growth, are actively ongoing.3,4

Unlike IVUS, however, OCT has a limitation in that it needs to create a blood-free zone. Therefore, balloon occlusion of the proximal vasculature for as long as 30 to 40 seconds is required.1 This limitation can provoke myocardial ischemia during the procedure and, in rare situations, intracoronary thrombus formation as demonstrated in this case.


*    Disclosures
up arrowTop
*Disclosures
down arrowReferences
 
None.


*    Footnotes
 
The online-only Data supplement, which consists of movies, is available with this article at http://circ.ahajournals.org/cgi/content/full/118/6/e101/DC1.


*    References
up arrowTop
up arrowDisclosures
*References
 
1. Regar E, Schaar JA, Mont E, Virmani R, Serruys PW. Optical coherence tomography. Cardiovasc Radiat Med. 2003; 4: 198–204.[CrossRef][Medline] [Order article via Infotrieve]

2. Yabushita H, Bouma BE, Houser SL, Aretz HT, Jang IK, Jang IK, Schlendorf KH, Kauffman CR, Shishkov M, Kang DH, Halpern EF, Tearney GJ. Characterization of human atherosclerosis by optical coherence tomography. Circulation. 2002; 106: 1640–1645.[Abstract/Free Full Text]

3. Jang IK, Bouma BE, Kang DH, Park SJ, Park SW, Seung KB, Choi KB, Shishkov M, Schlendorf K, Pomerantsev E, Houser SL, Aretz HT, Tearney GJ. Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound. J Am Coll Cardiol. 2002; 39: 604–609.[Abstract/Free Full Text]

4. Matsumoto D, Shite J, Shinke T, Otake H, Tanino Y, Ogasawara D, Sawara T, Paredes OL, Hirata K, Yokoyama M. Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography. Eur Heart J. 2007; 28: 961–967.[Abstract/Free Full Text]





This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Data Supplement
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kim, J.-S.
Right arrow Articles by Jang, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kim, J.-S.
Right arrow Articles by Jang, Y.
Related Collections
Right arrow Catheter-based coronary interventions: stents
Right arrow Coronary imaging: angiography/ultrasound/Doppler/CC
Right arrow Acute coronary syndromes
Right arrow Acute myocardial infarction