(Circulation. 1996;94:2447-2454.)
© 1996 American Heart Association, Inc.
Articles |
the Department of Internal Medicine, Division of Cardiology, St Louis University Health Sciences Center (D.D.M., T.J.D., T.L.W., M.J.K., M.B.C., C.M.M.), and Washington University School of Medicine (S.R.B., J.J.H.), St Louis, Mo.
Correspondence to D. Douglas Miller, MD, Division of Cardiology, St Louis University Health Sciences Center, 3635 Vista Ave at Grand Blvd, St Louis, MO 63110-0250.
| Abstract |
|---|
|
|
|---|
Methods and Results Eleven consecutive patients 53±13 years old with ischemic chest pain and isolated proximal left coronary artery stenoses (left anterior descending, 9; left circumflex, 2; mean, 59±23% diameter stenosis) underwent [15O]H2O myocardial PET and intracoronary Doppler flow velocity studies within 1 week. PET RMBF (mL·g-1·min-1) and myocardial perfusion reserve (MPR) were calculated in poststenotic and normal reference vascular beds. Poststenotic Doppler average peak flow velocities (APV; cm/s) and coronary flow velocity reserve (CFR) were compared with corresponding PET data and quantitative angiographic lesional parameters. PET RMBF and Doppler APV were linearly correlated (r=.60; P<.001), as were poststenotic PET MPR and Doppler CFR (r=.76; P<.0002). Relative coronary flow velocity and MPR ratios between poststenotic and angiographically normal vascular beds were comparably reduced (0.83±0.25 versus 0.86±0.21, respectively; P=NS).
Conclusions Intracoronary Doppler flow velocities acquired distal to isolated left coronary artery stenoses correlated with [15O]H2O PET regional myocardial perfusion and are useful for assessment of the physiological significance of coronary stenoses in humans.
Key Words: blood flow tomography coronary disease perfusion
| Introduction |
|---|
|
|
|---|
Although basal RMBF (mL·g-1·min-1) derived by use of [15O]H2O PET is unchanged by angiographically mild coronary stenoses, hyperemic RMBF progressively decreases distal to stenoses with >40% diameter reduction15 and is significantly augmented after successful coronary angioplasty of more severe coronary stenoses.16 PET MPR has been correlated with intracoronary flow velocity data acquired with Doppler catheters positioned proximal to stenoses in branching coronary arteries.17 18
However, proximal intracoronary hemodynamic measurements are potentially confounded by competitive flow in branch vessels and collateral flow effects.19 20 This and the technical limitations of 3F (1.0-mm2 cross-sectional area) Doppler catheters prompted the development of 0.018-in.-diameter (0.164-mm2 cross-sectional area) Doppler crystal-tipped angioplasty flow sensor devices that can atraumatically acquire poststenotic coronary flow velocities that are less subject to the problems associated with proximally recorded values.21 22 Studies with this device have shown that although basal Doppler coronary blood flow velocities remain unchanged distal to angiographically mild to moderate coronary stenoses, hyperemic poststenotic CFR is blunted as stenosis severity worsens8 and is improved by successful coronary angioplasty.23
These two methodologically diverse physiological techniques, [15O]H2O PET RMBF and poststenotic Doppler coronary blood flow, have not been directly compared in humans. The clinical application of these studies could improve the accuracy of coronary artery disease assessment, particularly in patients with functionally unpredictable angiographic stenoses of moderate severity. The objective of the present study was to evaluate the relationship between quantitative measurements of angiographic stenosis severity, [15O]H2O PET RMBF, and Doppler coronary flow velocity in the poststenotic vascular bed of patients with stable chest pain with an isolated proximal stenosis in the left anterior descending or circumflex coronary arteries.
It was postulated that correlations between these two physiological parameters (ie, coronary flow and nutritive myocardial perfusion) would exceed correlations of these functional data with quantitative coronary angiographic descriptors of anatomic stenosis severity under basal and hyperemic conditions.
| Methods |
|---|
|
|
|---|
Angiographic, PET, and Doppler studies were performed within 1 week of each other without intercurrent changes in clinical status or medical therapy.
Quantitative Coronary Angiography
Selective coronary arteriography was performed in multiple orthogonal views and angulations to optimally define the coronary artery stenosis and to exclude additional coronary lesions. End-diastolic cineangiographic frames were used for quantitative analysis to minimize cardiac motion artifact and to maximize coronary contrast. Overlapping vessels and backfield bony structures adjacent to the index coronary lesion were avoided.24 Coronary artery stenoses of >10% luminal diameter reduction (ie, %DS) of the left anterior descending or left circumflex coronary arteries were measured with a quantitative cardiovascular angiographic software program in two orthogonal angiographic views separated by 90°. The most severe coronary stenosis measurement derived from this analysis was used for comparison with Doppler flow and PET data. The quantification software program (Automated Coronary Analysis, Philips, D.C.I.25 26 ) was used by experienced operators blinded to the intracoronary Doppler and PET data. The following coronary stenosis parameters were derived: vessel segment diameter (in millimeters) proximal to, distal to, and within the obstructive lesion; %DS; and %AS.
Premedications and intraprocedural vasodilator medications were minimized and carefully recorded. Nitroglycerin was not administered before contrast injections during coronary angiography. The contrast agent used was ioxaglate meglumine (39%) and ioxaglate sodium (20%) (Hexabrix). Contrast left ventriculography was performed after diagnostic angiography and Doppler studies.
Coronary Flow Velocity Measurement
Coronary flow velocity measurements were performed by experienced operators using a Doppler-tipped angioplasty guidewire (Cardiometrics, Inc), as previously described.8 21 22 23 In brief, this 175-cm-long, flexible, steerable angioplasty guidewire 0.018 in. in diameter is equipped with a 12-MHz piezoelectric ultrasound transducer at its tip that permits velocity acquisition with a high pulse repetition frequency (up to 90 kHz) from a sampling depth of 5 mm. Coronary flow velocities up to 4 m/s can be recorded without aliasing. This forward-directed ultrasound beam with a 25° divergent angle samples a large portion of the coronary flow profile. The velocity data are processed by on-line fast Fourier transformation with a real-time scrolling spectral gray-scale display and are recorded onto a ½-in. videotape for subsequent off-line analysis. This technique has been used without complications in more than 800 studies at our institution.
After diagnostic angiography and heparinization (5000 U IV), the Doppler guidewire was advanced through a 6F angiographic catheter into the normal reference coronary artery. Baseline flow velocities were first recorded in the angiographically normal reference vessel, after which the guidewire was repositioned in the proximal portion of the stenotic artery. Flow velocities were acquired at least 1 cm proximal to the stenosis at baseline. The guidewire was then advanced 5 to 10 artery diameters beyond the stenosis to record baseline distal coronary velocities. After intravenous administration of dipyridamole, peak stress coronary flow velocities were recorded beginning 4 to 6 minutes later from the poststenotic and the proximal coronary sites and again after the rapid (1 to 2 minutes) transfer of the guidewire back to the normal reference vessel.
Doppler signal analysis was performed by digitization of the coronary flow velocity spectral envelope off-line using a PC/AT computer with custom-developed software interfaced with a digitizing tablet. The outermost margin of each velocity spectrum was digitized to minimize significant intraobserver and interobserver variability. Digitized spectral peak velocity waveforms from five cardiac cycles were averaged to compute the coronary flow velocity under basal and dipyridamole hyperemic conditions. The APV (in cm/s) was derived under basal and hyperemic conditions. The CFR was computed as the ratio of hyperemic to basal APV. On the basis of previous validation studies in our own and other laboratories,20 21 22 23 the lower limit of normal poststenotic CFR is defined as >2.0, the mean value minus 1 SD in patients with angiographically normal coronary arteries.
The relative CFR ratio (theoretically equaling 1.0) between the stenotic and normal reference coronary arterial beds was also computed and compared with a similar [15O]H2O PET MPR ratio derived from corresponding vascular beds.10 The nondiseased left coronary artery branch was used as the reference vessel for the acquisition of normal coronary flow and myocardial perfusion data in all but one patient, in whom the right coronary vessel was used.
Pharmacological Stress With Dipyridamole
To ensure sustained and comparable hyperemic coronary flow between the Doppler and PET studies, an intravenous infusion of dipyridamole in a dose of 0.56 mg/kg over a period of 4 minutes (140 µg·kg-1·min-1) was initiated with the guidewire positioned in the poststenotic portion of the stenotic artery. Maximal dipyridamole hyperemic intracoronary flow velocity data were recorded beginning 4 to 6 minutes after the end of drug infusion; flows, heart rate, and blood pressure were monitored continuously during the infusion. Maximal dipyridamole-induced coronary hyperemia is sustained at peak levels for
20 minutes in humans.27
All studies were performed in the morning with the patients in a fasting state. Cardiac medications were not interrupted before drug stress studies. Methyl xanthinecontaining medications, food, or drinks were withheld for >48 hours before both studies. Sublingual nitroglycerin and parenteral aminophylline were available but were not required to reverse dipyridamole side effects.
[15O]H2O Myocardial PET Studies
A validated [15O]H2O PET myocardial perfusion imaging protocol was used (Fig 1
).12 28 After the patient was positioned in the SP-3000E whole-body time-of-flight PET imaging system,29 a transmission scan of the chest was obtained with a 68Ge/68Ga ring source to correct for photon attenuation of the emitted radiation and to ensure that four to six of the seven cross-sectional imaging planes intersected the myocardium.
|
After collection of attenuation data, 40 to 50 mCi of [15O]CO was administered by inhalation to label red cells in the blood pool. After 30 to 60 seconds for clearance of labeled [15O]CO from the lungs, emission data were collected for 5 minutes under basal conditions. [15O]H2O (0.4 mCi/kg) was then injected as a bolus through a large-bore antecubital vein catheter, with data collected for 150 seconds after the onset of tracer administration in list mode. After a 5- to 10-minute interval for decay of activity to baseline levels, dipyridamole (0.56 mg/kg IV) was administered over a period of 4 minutes (in a manner identical to that used for the Doppler flow velocity study), and the [15O]H2O PET imaging sequence was repeated beginning 4 to 6 minutes after cessation of dipyridamole infusion to assess the maximal hyperemic myocardial blood flow response. [15O]CO (40 to 50 mCi) was then readministered.
Transaxial slices were reconstructed with a center-to-center slice separation of 1.5 cm and slice thickness of 1.14 cm. Filtered reconstructions of these high-resolution emission data provide resolution within the plane of reconstruction of 13.5 mm. A single 120-second [15O]H2O data acquisition was reconstructed for ROI placement. Data obtained in the 120-second composite acquisition after administration of [15O]H2O were corrected on a pixel-by-pixel basis for [15O]H2O remaining in the vasculature. Unsubtracted [15O]H2O data were reconstructed into eighteen 5-second frames (total of 90 seconds) after the appearance of activity in the left atrial blood pool. Decay-corrected counts per data point were then computed from each 5-second frame. Calculation of RMBF within each myocardial ROI requires knowledge of the arterial input function (obtained from an ROI) and the myocardial time-activity profile of [15O]H2O. Absolute RMBF (mL·g-1·min-1) was calculated by use of a previously validated one-compartment kinetic model, with data corrected for attenuation, tracer decay, partial volume effect, and count spillover.
A total of seven transverse images were available for the analysis of RMBF. From these images, the three transverse slices in which septal, anterior, lateral, and posterior myocardial activity could all be identified were selected for the placement of ROIs. The averages of those PET perfusion data derived from midventricular and apical ROIs found distal to the index coronary stenosis were compared with corresponding distal intracoronary Doppler flow data.
Myocardial ROIs of
3 cm3 (1x3x1 cm) were placed within predefined vascular distributions subtending the left anterior descending (anterior ROI) and left circumflex (lateral ROI) coronary beds. The septal ROI was placed in the most anterior and apical part of the septal myocardial activity but was not analyzed so as to minimize the chances of including basal-inferoseptal myocardium supplied by the right coronary artery. Posterior wall measurements demonstrated RMBF interstudy measurement variability comparable to those obtained from the other vascular territories; these were used in the normal reference RMBF calculation of one patient (patient 1).
Statistical Analysis
Group values (mean±SD) are reported for the clinical, angiographic, intracoronary Doppler, and PET myocardial perfusion parameters. Correlations between continuous angiographic, intracoronary hemodynamic, and PET imaging data were performed by linear regression (Pearson product moment) with commercially available statistical software. Two-way ANOVA was used to compare multiple subgroups of continuous variables. Intergroup differences were considered significant at a probability value of P<.05 to reject the null hypothesis.
| Results |
|---|
|
|
|---|
|
Hemodynamics During Dipyridamole
The basal heart rate did not differ between Doppler and PET studies (81±21 versus 71±14 bpm; P=NS) (Table 2
). Peak dipyridamole heart rates were also similar (94±17 versus 87±14 bpm; P=NS). Systolic blood pressure was comparable under basal conditions (141±23 versus 138±21 mm Hg; P=NS) and at peak stress (128±22 versus 137±17 mm Hg; P=NS).
|
Basal cardiac double product between Doppler and PET studies (10 700±3900 versus 9500±2200; P=NS) and peak dipyridamole stress cardiac double product were also comparable (12 200±4300 versus 11 500±1700; P=NS). There were no serious adverse reactions during dipyridamole infusion.
Doppler Coronary Blood Flow
The APV increased significantly during hyperemia in both the index vessel (19±6 to 45±19 cm/s; P<.01) and the reference vessel (22±10 to 58±22 cm/s; P<.01) (Table 3
). The CFR increased to an average of 2.3±0.7 in the index vessel, compared with 2.8±0.7 in the reference vessel (P<.03). The relative Doppler CFR was 0.86±0.21.
|
Index coronary artery volumetric flow increased from a mean value of 49±26 to 120±85 mL/min during hyperemia (P<.05). Volumetric flow in the reference vessel increased to a greater mean level during hyperemia (54±28 versus 150±97 mL/min; P<.05).
PET Myocardial Blood Flow
RMBF in the index vessel increased from 1.3±0.4 to 2.7±0.9 mL·g-1·min-1 during hyperemia (P<.05) (Table 4
). In the reference artery, PET RMBF increased from 1.3±0.4 to 2.8±0.7 mL·g-1·min-1 during hyperemia (P<.05).
|
The mean MPR in the index vessel was 2.1±0.8, compared with 2.4±0.9 in the reference vessel (P=NS). Relative MPR, the ratio of PET perfusion reserve between the index and reference arteries, averaged 0.83±0.25.
Correlation of Doppler Flow and PET Myocardial Perfusion
An example of the correlation between Doppler flow, quantitative coronary angiography, and [15O]H2O PET regional myocardial perfusion data is provided in Figs 2
and 3.
|
|
There was a significant correlation between Doppler coronary APV and PET RMBF (r=.60; P<.001; Fig 4
). A highly significant linear correlation was observed between Doppler-derived CFR and PET-derived MPR over a wide range of flows in the index and reference vessels (r=.76; P<.0002; Fig 5
).
|
|
A trend toward a correlation existed between Doppler-derived CFR and minimal luminal diameter (r=.41; P<.07). No correlation was obtained between PET-derived perfusion reserve and minimal luminal diameter, %DS, stenosis length, or %AS.
| Discussion |
|---|
|
|
|---|
Previous PET Correlations of Stenosis Severity
The Doppler coronary blood flow velocity technique measures normal and poststenotic flows under varied physiological conditions,20 21 22 23 supplying information previously restricted to noninvasive myocardial perfusion imaging.11 12 16 31 32 33 The relative MPR values obtained with [15O]H2O PET and Doppler coronary flow analysis in the present study were comparable to those derived by Goldstein et al,10 who used 82Rb or [13N]NH3 PET. In these studies, considerable scatter was noted about curves correlating angiographic and physiological parameters, reinforcing the known limitations of coronary angiography in comparing two-dimensional geometric descriptors of coronary anatomy with functional measures of coronary physiology, especially in the intermediate range of stenosis severity.30 The correlation of two physiological end points of coronary blood flow more accurately reflects the functional severity of coronary stenoses than angiography alone.8 9 31
PET myocardial imaging during dipyridamole-induced coronary vasodilation with either [13N]NH3 or 82Rb (References 7 and 8, respectively) has been used to derive MPR. Although PET imaging is 95% sensitive for coronary lesions with an angiographically determined flow reserve <3.0, the diagnostic accuracy of PET imaging decreases when angiographically less severe (ie, intermediate) lesions of
50% diameter stenosis (versus >70%) are considered significant.15 33
The absolute quantification of RMBF can be achieved by use of PET with either [13N]NH3 or [15O]H2O (References 13, 31, and 34, and 11 and 12, respectively). [15O]H2O has several advantages as a PET blood flow tracer, including the properties of being a readily diffusible, nonmetabolized tracer with purely flow-dependent myocardial kinetics35 and a short physical half-life. Techniques for the conversion of regional [15O]H2O tomographic myocardial distribution to quantify RMBF have been validated in humans over a wide range of flows.11 12 16 28
Intermediate Coronary Stenosis Assessment
Variations in [15O]H2O PET image homogeneity and derived perfusion measurements reflect regional differences in myocardial tracer uptake. A relative PET MPR of 1.0 has been reported when vessels with stenoses ranging from 21%DS to 60%DS (mean, 46±12%DS) are compared with normal reference vessel beds.10 This suggests that angiographically normal vessels and vessels with intermediate stenoses may respond similarly to hyperemic stress, because of either a limited vasodilatory response of the normal reference bed, inaccuracy (ie, overestimation) of angiographic lesion severity in the diseased bed, or underestimation of angiographic disease severity in the normal reference bed.
Although Uren et al15 were able to clearly distinguish severe (>70%DS) from mild (<30%DS) stenoses with [15O]H2O PET (MPR, 1.3±0.8 versus 4.6±0.8; P<.05), a larger subset of their population (19 of 35 patients) with intermediate severity (30%DS to 70%DS) lesions had a mean stenosis severity and a perfusion reserve that did not differ from a control population (52±11%DS versus 56±20%DS and 2.0±1.0 versus 2.1±1.3, respectively).
Recent studies from our own laboratory8 22 using poststenotic intracoronary flow velocity data have demonstrated a wide range of poststenotic CFR responses in patients with intermediate coronary artery stenosis severity (56±14%DS). PET imaging data derived by other investigators indicate that considerable variability also exists in flow and perfusion in angiographically normal vascular beds.15 31 34
Study Limitations
The limitations of using isolated quantitative angiographic lesional parameters for determining the physiological characteristics of a coronary lesion are well known,24 36 37 especially in the setting of intermediate-severity coronary stenoses as encountered in this study.9 30 The administration of nitrates before angiography reduces the potential for interstudy lesion variability secondary to alterations in vasomotor tone.38 This procedure was not routinely applied in our study so as to reduce variation in coronary flow velocity data by persisting nitrate vasodilating effects occurring over the hyperemic period. The volumetric flow data could theoretically have been modified by pretreatment with nitrates or dipyridamole or at high flow rates, all of which may affect vessel cross-sectional area.
[15O]H2O PET perfusion imaging has some limitations. After blood pool activity subtraction using [15O]CO in the blood pool, [15O]H2O PET myocardial images are not as smooth as those observed with 82Rb or [13N]NH3. Quantification of RMBF from transverse PET images is not ideal and requires meticulous correction for cardiac motion and partial volume effects and an accurate determination of the arterial input function.12 14 Previous studies have reported higher than optimal variability in normal resting/basal (35±10%) and hyperemic (29±15%) RMBF,16 which may limit the ability of [15O]H2O PET to independently differentiate subtle RMBF differences in serial studies.
This and previous studies15 16 have preferentially excluded populations with multivessel CAD, reducing the potential complexities associated with balanced coronary disease (ie, absence of a true normal reference vascular bed), coronary collateral flow effects, and the need for measurements of Doppler flow and perfusion in all arterial beds. However, the potential for false-negative myocardial imaging studies in patients with balanced multivessel CAD that reduces the flow heterogeneity required for standard perfusion defect visualization is theoretically reduced by absolute RMBF determinations derived with [15O]H2O PET.
Finally, relatively simple techniques39 40 and more sophisticated methods for the quantification of left ventricular mass41 and of coronary vascular bed size42 have been reported, but these were not applied to correct regional coronary flow data for the size of the vascular bed in the present study.
Conclusions
Quantitative PET myocardial perfusion and poststenotic Doppler flow velocity are correlated and can be used clinically to distinguish the physiological significance of coronary lesions in humans. The application of these quantitative physiological techniques in the clinical assessment of coronary artery disease provides objective evidence of lesion significance, which may also be useful to support the decision for coronary revascularization interventions, especially in patients with angiographically intermediate coronary stenoses in which a range of flow reserve abnormalities exists.
| Selected Abbreviations and Acronyms |
|---|
|
| Acknowledgments |
|---|
| Footnotes |
|---|
Received January 9, 1996; revision received May 31, 1996; accepted June 10, 1996.
| References |
|---|
|
|
|---|
2. Gould LK, Schelbert HR, Phelps ME, Hoffman EJ. Noninvasive assessment of coronary stenoses with myocardial perfusion imaging during pharmacologic coronary vasodilation. Am J Cardiol. 1979;43:200-208.[Medline] [Order article via Infotrieve]
3. Gould KL, Goldstein RA, Mullani NA, Kirkeeide RL, Wong WH, Tewson TJ, Berridge MS, Bolomey LA, Hartz RK, Smalling RW, Fuentes F, Nishikawa A. Noninvasive assessment of coronary stenoses by myocardial perfusion imaging during pharmacologic coronary vasodilation, VIII: clinical feasibility of positron cardiac imaging without a cyclotron using generator-produced rubidium-82. J Am Coll Cardiol. 1986;7:775-789.[Abstract]
4. Kirkeeide RL, Gould KL, Parsel L. Assessment of coronary stenoses by myocardial perfusion imaging during pharmacologic coronary vasodilation, VII: validation of coronary flow reserve as a single integrated functional measure of stenosis severity reflecting all its geometric dimensions. J Am Coll Cardiol. 1986;7:103-113.[Abstract]
5.
Gould KL, Kelley KO, Bolson EL. Experimental validation of quantitative coronary arteriography for determining pressure-flow characteristics of coronary stenosis. Circulation. 1982;66:930-937.
6. Schelbert HR, Wisenberg G, Phelps ME, Gould KL, Henze E, Hoffman EJ, Gomes A, Kuhl DE. Noninvasive assessment of coronary stenoses by myocardial imaging during pharmacologic coronary vasodilation, VI: detection of coronary artery disease in human beings with intravenous N-13 ammonia and positron computed tomography. Am J Cardiol. 1982;49:1197-1207.[Medline] [Order article via Infotrieve]
7.
Wilson RF, Marcus ML, White CW. Prediction of the physiologic significance of coronary arterial lesions by quantitative lesion geometry in patients with limited coronary artery disease. Circulation. 1987;75:723-732.
8.
Miller DD, Donohue TJ, Younis LT, Bach RG, Aguirre FV, Wittry MD, Goodgold HM, Chaitman BR, Kern MJ. Correlation of pharmacological 99mTc-sestamibi myocardial perfusion imaging with poststenotic coronary flow reserve in patients with angiographically intermediate coronary artery stenoses. Circulation. 1994;89:2150-2160.
9. Zijlstra F, Fioretti P, Reiber JHC, Serruys PW. Which cineangiographically assessed anatomic variable correlates best with functional measurements of stenosis severity? A comparison of quantitative analysis of the coronary cineangiogram with measured coronary flow reserve and exercise/redistribution thallium-201 scintigraphy. J Am Coll Cardiol. 1988;12:686-691.[Abstract]
10. Goldstein RA, Kirkeeide RL, Demer LL, Merhige M, Nishikawa A, Smalling RW, Mullani NZ, Gould KL. Relation between geometric dimensions of coronary artery stenoses and myocardial perfusion reserve in man. J Clin Invest. 1987;79:1473-1478.
11.
Araujo LI, Lammertsma AA, Rhodes CG, McFalls EO, Iida H, Rechavia E, Galassi A, DeSilva R, Jones T, Maseri A. Noninvasive quantitation of regional myocardial blood flow in coronary artery disease with oxygen-15-labeled carbon dioxide inhalation and positron emission tomography. Circulation. 1991;83:875-885.
12. Bergmann SR, Herrero P, Markham J, Weinheimer CJ, Walsh MN. Noninvasive quantitation of myocardial blood flow in human subjects with oxygen-15-labeled water and positron emission tomography. J Am Coll Cardiol. 1989;14:639-652.[Abstract]
13. Hutchins GD, Schwaiger M, Rosenspire KC, Krivokapich J, Schelbert H, Kuhl DE. Noninvasive quantification of regional blood flow in the human heart using N-13 ammonia with dynamic positron emission tomographic imaging. J Am Coll Cardiol. 1990;15:1032-1042.[Abstract]
14.
Bergmann SR, Fox KAA, Rand AL, McElvany KD, Wellch MJ, Markham J, Sobel BE. Quantification of regional myocardial blood flow in vivo with H215O. Circulation. 1984;70:724-773.
15.
Uren NG, Melin JA, De Bruyne B, Wijns W, Baudhuin T, Camici PG. Relation between myocardial blood flow and the severity of coronary artery stenosis. N Engl J Med. 1994;330:1782-1788.
16. Walsh MN, Geltman EM, Steele RL, Kenzora JL, Ludbrook PA, Sobel BE, Bergmann SR, Courtois M, Weinheimer CJ. Augmented myocardial perfusion reserve after coronary angioplasty quantified by positron emission tomography with H215O. J Am Coll Cardiol. 1990;15:119-127.[Abstract]
17.
Merlet P, Mazoyer B, Hittinger L,Valette H, Saal JP, Bendriem B, Crozatier B, Castaigne A, Syrota A, Dubois Rande JL. Assessment of coronary reserve in man: comparison between positron emission tomography with oxygen-15 labeled water and intracoronary Doppler technique. J Nucl Med. 1993;34:1899-1904.
18.
Shelton M, Senneff MJ, Ludbrook PA, Sobel BE, Bergmann SR. Concordance of nutritive myocardial perfusion reserve and flow velocity reserve in conductance vessels in patients with chest pain and angiographically normal coronary arteries. J Nucl Med. 1993;34:717-722.
19. Serruys PW, DiMario C, Meneveau N, de Jaegere P, Strikwerda S, de Feyter PJ, Emanuelsson H. Intracoronary pressure and flow velocity with sensor-tip guidewires: a new methodologic approach for assessment of coronary hemodynamics before and after coronary interventions. Am J Cardiol. 1993;71:41D-53D.[Medline] [Order article via Infotrieve]
20.
Doucette JW, Corl PD, Payne HM, Flynn AE, Goto M, Nassi M, Segal J. Validation of Doppler guide wire for intravascular measurement of coronary artery flow velocity. Circulation. 1992;85:1899-1911.
21. Segal J, Kern MJ, Scott NA, King SB III, Douchette JW, Heuser RR, Ofili E, Siegel R. Alterations of phasic coronary artery flow velocity in humans during percutaneous coronary angioplasty. J Am Coll Cardiol. 1992;20:276-286.[Abstract]
22. Donohue TJ, Kern MJ, Aguirre FV, Bach RG, Wolford T, Bell CA, Segal J. Assessing the hemodynamic significance of coronary stenoses: analysis of translesional pressure-flow velocity relationships in patients. J Am Coll Cardiol. 1993;22:449-458.[Abstract]
23. Ofili EO, Kern MJ, Labovitz AJ, St Vrain JA, Segal J, Aguirre F, Castello R. Analysis of coronary blood flow velocity dynamics in angiographically normal and stenosed arteries before and after endoluminal enlargement by angioplasty. J Am Coll Cardiol. 1993;21:308-316.[Abstract]
24. Brown BG, Bolson EL, Dodge HT. Quantitative computer techniques for analyzing coronary arteriograms. Prog Cardiovasc Dis. 1986;28:403-418.[Medline] [Order article via Infotrieve]
25. Reiber JHC, Kooijman CJ, Slager CT. Coronary artery dimensions from cineangiograms: methodology and validation of a computer-assisted analysis procedure. IEEE Trans Med Imaging. 1984;MI-3:131-140.
26. Reiber JHC. On-line quantification of coronary angiograms with DCI system. Medica Mundi. 1989;34:89-98.
27. Al-Joundi B, Miller DD. Does aminophylline dose (125 mg vs 250 mg) alter the kinetics of dipyridamole coronary hyperemia reversal or attenuate the response to coronary vasodilator rechallenge? Circulation. 1993;88(suppl I):I-439. Abstract.
28.
Herrero P, Hartman JJ, Senneff MJ, Bergmann SR. Effects of time discrepancies between input and myocardial time-activity curves on estimates of regional myocardial perfusion with PET. J Nucl Med. 1994;35:558-566.
29. Ter-Pogossian MM, Ficke DC, Beecher DE, Hoffman GR, Bergman SR. The super PET 3000-E: a PET scanner designed for high count rate cardiac applications. J Comput Assist Tomogr. 1994;18:661-669.[Medline] [Order article via Infotrieve]
30. Vogel RA. Assessing stenosis significance by coronary arteriography: are the best variables good enough? J Am Coll Cardiol. 1988;12:692-693.[Medline] [Order article via Infotrieve]
31. Beanlands R, Melon PG, Muzik O, Sawada S, Sutor R, Muller D, Bondie D, Hutchins G, Schwaiger M. N-13 ammonia PET identifies reduced perfusion reserve in angiographically normal regions of patients with CAD. Circulation. 1992;86(suppl I):I-184. Abstract.
32. Schelbert HR, Wisenberg G, Phelps ME, Gould KL, Henze E, Hoffman EJ, Gomes A, Kuhl DE. Noninvasive assessment of coronary stenosis by myocardial imaging during pharmacologic coronary vasodilation, VI: detection of coronary artery disease in man with intravenous 13NH3 and positron computed tomography. Am J Cardiol. 1982;49:1197-1207.
33. Stewart RE, Schwaiger M, Molina E, Popma J, Gacioch GM, Kalus M, Squicciarini S, Al-Aouar ZR, Schork A, Kuhl DE. Comparison of rubidium-82 PET with thallium-201 SPECT imaging for the detection of coronary artery disease. Am J Cardiol. 1991;67:1303-1310.[Medline] [Order article via Infotrieve]
34.
Vanoverschelde JJ, Wijns W, Depre C, Essamri B, Heyndrickx GR, Borgers M, Bol A, Melin JA. Mechanisms of chronic regional postischemic dysfunction in humans. Circulation. 1993;87:1513-1523.
35. Bassingthwaighte JB, Goresky CA. Modeling in the analysis of solute and water exchange in the microvasculature. In: Renken EM, Michel CC, eds. Handbook of Physiology, Section 2: The Cardiovascular System, Volume IV. Bethesda, Md: American Physiological Society; 1984:549-626.
36. Jost S, Deckers JW, Nellessen U. Clinical application of quantitative coronary angiography using the CAAS system: preliminary results of the INTACT study. Int J Card Imaging. 1988;3:75-86.[Medline] [Order article via Infotrieve]
37.
Harrison DG, White CW, Hiratzka LF, Doty DB, Barnes DH, Eastham CL, Marcus ML. The value of lesion cross-sectional area determined by quantitative coronary arteriography in assessing the physiologic significance of proximal left anterior descending coronary artery stenosis. Circulation. 1984;69:1111-1119.
38. Brown BG. Response of normal and diseased epicardial coronary arteries to vasoactive drugs: quantitative angiographic studies. Am J Cardiol. 1985;56:23E-29E.[Medline] [Order article via Infotrieve]
39.
Devereux RB, Reichek N. Echocardiographic determination of left ventricular mass in man: anatomic validation of the method. Circulation. 1977;55:613-616.
40.
Leung WH, Stadius ML, Alderman EL. Determinants of normal coronary artery dimensions in humans. Circulation. 1991;84:2294-2306.
41. Collins HW. Reproducibility of left ventricular mass measurements by two-dimensional and M-mode echocardiography. J Am Coll Cardiol. 1989;14:672-676.[Abstract]
42. Seiler C, Kirkeeide RL, Gould KL. Measurement from arteriograms of regional myocardial bed size distal to any point in the coronary vascular tree for assessing anatomic area at risk. J Am Coll Cardiol. 1993;21:783-797.[Abstract]
This article has been cited by other articles:
![]() |
T. Kurita, H. Sakuma, K. Onishi, M. Ishida, K. Kitagawa, T. Yamanaka, T. Tanigawa, T. Kitamura, K. Takeda, and M. Ito Regional myocardial perfusion reserve determined using myocardial perfusion magnetic resonance imaging showed a direct correlation with coronary flow velocity reserve by Doppler flow wire Eur. Heart J., February 2, 2009; 30(4): 444 - 452. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. M. Marques, P. Knaapen, R. Boellaard, A. A. Lammertsma, N. Westerhof, and F. C. Visser Microvascular Function in Viable Myocardium After Chronic Infarction Does Not Influence Fractional Flow Reserve Measurements J. Nucl. Med., December 1, 2007; 48(12): 1987 - 1992. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. A. Barmeyer, A. Stork, K. Muellerleile, C. Tiburtius, A. K. Schofer, T. A. Heitzer, T. Hofmann, G. Adam, T. Meinertz, and G. K. Lund Contrast-enhanced Cardiac MR Imaging in the Detection of Reduced Coronary Flow Velocity Reserve Radiology, May 1, 2007; 243(2): 377 - 385. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. A.L. Ahmari, K. Modesto, J. Bunch, V. Stussy, A. Dichak, J. Seward, P. Pellikka, and K. Chandrasekaran Doppler derived coronary flow reserve during dobutamine stress echocardiography further improves detection of myocardial ischemia Eur J Echocardiogr, March 1, 2006; 7(2): 134 - 140. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. C. Brunken, J. K. Perloff, J. Czernin, R. Campisi, S. Purcell, P. D. Miner, J. S. Child, and H. R. Schelbert Myocardial perfusion reserve in adults with cyanotic congenital heart disease Am J Physiol Heart Circ Physiol, November 1, 2005; 289(5): H1798 - H1806. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Fenchel, A. Franow, N. I. Stauder, U. Kramer, U. Helber, C. D. Claussen, and S. Miller Myocardial Perfusion after Angioplasty in Patients Suspected of Having Single-Vessel Coronary Artery Disease: Improvement Detected at Rest-Stress First-Pass Perfusion MR Imaging--Initial Experience Radiology, October 1, 2005; 237(1): 67 - 74. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Sakuma, N. Suzawa, Y. Ichikawa, K. Makino, T. Hirano, K. Kitagawa, and K. Takeda Diagnostic Accuracy of Stress First-Pass Contrast-Enhanced Myocardial Perfusion MRI Compared with Stress Myocardial Perfusion Scintigraphy Am. J. Roentgenol., July 1, 2005; 185(1): 95 - 102. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Diamantopoulos, X. Liu, I. De Scheerder, R. Krams, S. Li, J. Van Cleemput, W. Desmet, and P. W Serruys The effect of reduced blood-flow on the coronary wall temperature: Are significant lesions suitable for intravascular thermography? Eur. Heart J., October 1, 2003; 24(19): 1788 - 1795. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Ishida, H. Sakuma, M. Motoyasu, T. Okinaka, N. Isaka, T. Nakano, and K. Takeda Noninfarcted Myocardium: Correlation between Dynamic First-Pass Contrast-enhanced Myocardial MR Imaging and Quantitative Coronary Angiography Radiology, October 1, 2003; 229(1): 209 - 216. [Abstract] [Full Text] [PDF] |
||||
![]() |
T Reffelmann, H G Klues, P Hanrath, and E R Schwarz Post-stenotic coronary blood flow at rest is not altered by therapeutic doses of the oral antidiabetic drug glibenclamide in patients with coronary artery disease Heart, January 1, 2002; 87(1): 54 - 60. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Frouin, P. Merlet, Y. Bouchareb, V. Frouin, J.-L. Dubois-Rande, A. De Cesare, A. Herment, A. Syrota, and A. Todd-Pokropek Validation of Myocardial Perfusion Reserve Measurements Using Regularized Factor Images of H215O Dynamic PET Scans J. Nucl. Med., December 1, 2001; 42(12): 1737 - 1746. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. D. Krier, E. L. Ritman, Z. Bajzer, J. C. Romero, A. Lerman, and L. O. Lerman Noninvasive measurement of concurrent single-kidney perfusion, glomerular filtration, and tubular function Am J Physiol Renal Physiol, October 1, 2001; 281(4): F630 - F638. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Otsuka, H. Watanabe, K. Hirata, K. Tokai, T. Muro, M. Yoshiyama, K. Takeuchi, and J. Yoshikawa Acute Effects of Passive Smoking on the Coronary Circulation in Healthy Young Adults JAMA, July 25, 2001; 286(4): 436 - 441. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Kern and B. Meier Evaluation of the Culprit Plaque and the Physiological Significance of Coronary Atherosclerotic Narrowings Circulation, June 26, 2001; 103(25): 3142 - 3149. [Full Text] [PDF] |
||||
![]() |
H. Sakuma, J. W. Koskenvuo, P. Niemi, N. Kawada, J. O. Toikka, J. Knuuti, H. Laine, M. Saraste, M. Kormano, and J. J. Hartiala Assessment of Coronary Flow Reserve Using Fast Velocity-Encoded Cine MR Imaging: Validation Study Using Positron Emission Tomography Am. J. Roentgenol., October 1, 2000; 175(4): 1029 - 1033. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Al-Saadi, E. Nagel, M. Gross, A. Bornstedt, B. Schnackenburg, C. Klein, W. Klimek, H. Oswald, and E. Fleck Noninvasive Detection of Myocardial Ischemia From Perfusion Reserve Based on Cardiovascular Magnetic Resonance Circulation, March 28, 2000; 101(12): 1379 - 1383. [Abstract] [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1996 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |