(Circulation. 1999;99:2669-2676.)
© 1999 American Heart Association, Inc.
Clinical Investigation and Reports |
From the Department of Obstetrics and Gynaecology, University of Auckland (R.A.N., L.S., L.M.E.M.); the Department of Community Health, University of Auckland (A.W.S.); and the Departments of Cardiology (H.D.W.) and Cardiothoracic Surgery (A.R.K.), Green Lane Hospital, Auckland, New Zealand.
Correspondence to Dr Robyn North, Department of Obstetrics and Gynaecology, National Women's Hospital, Claude Rd, Private Bag 92 189, Auckland 1030, New Zealand. E-mail r.north{at}auckland.ac.nz
| Abstract |
|---|
|
|
|---|
Methods and ResultsIn this retrospective study, all women 12 to 35 years old who underwent valve replacements between 1972 and 1992 at Greenlane Hospital were identified, and follow-up was available in 93%. The 232 women were followed up for 1499 patient-years. Ten-year survival of women with mechanical (n=178), bioprosthetic (n=73), and homograft (n=72) valves was 70% (95% CI, 59% to 83%), 84% (95% CI, 72% to 99%), and 96% (95% CI, 91% to 100%), P=0.002. After adjustment for confounding variables, the relative risk (RR) of death with mechanical compared with bioprosthetic valves was 2.17 (95% CI, 0.78 to 5.88). Thromboembolic events occurred in 45% of women with mechanical valves within 5 years, compared with 13% with bioprosthetic valves, P=0.0001. Valve loss at 10 years was higher in bioprosthetic valves [82% (95% CI, 62% to 92%)] than in mechanical [29% (95% CI, 17% to 39%)] or homograft [28% (95% CI, 12% to 41%)] valves, P=0.0001. Pregnancy was not associated with increased bioprosthetic (RR, 0.96; 95% CI, 0.68 to 1.35), homograft (RR, 0.65; 95% CI, 0.37 to 1.13), or mechanical (RR, 0.54; 95% CI, 0.27 to 1.08) valve loss.
ConclusionsAlthough 10-year valve survival was greater with mechanical than bioprosthetic valves, mechanical valves may be associated with reduced patient survival in young women. Thromboembolic complications, often with long-term sequelae, were common with mechanical valves. Pregnancy did not increase structural deterioration or reduce survival of bioprosthetic valves.
Key Words: valves women pregnancy
| Introduction |
|---|
|
|
|---|
Women with mechanical prosthetic valves are at risk of thromboembolic events and require lifelong anticoagulation.5 6 This has the attendant risk of hemorrhage and poses significant hazards to both mother and baby in future pregnancies.2 3 7 8 9 10 Warfarin use in pregnancy is associated with a low risk of maternal thromboembolic complications but high fetal losses.2 3 7 Heparin therapy significantly improves fetal outcome, but up to one third of pregnant women with mechanical valves have thromboembolic complications, including fatal events.2 3 9
The high rate of complications in pregnancy in women with mechanical valves has led some groups to suggest that bioprosthetic valves may be the preferred valve replacement in women who are anticipating having a child.1 3 Women with bioprosthetic valves need only short-duration anticoagulation after valve replacement, provided that sinus rhythm is maintained, and usually have a successful pregnancy outcome.4 However, as young patients with bioprosthetic valves are at risk of early reoperation because of increased structural valvular deterioration,11 there is reluctance to use these valves in the young.12 Concern has also been raised that pregnancy may hasten the rate of structural deterioration of bioprosthetic valves.2 13 The controlled study reporting this was confounded by younger age in the women who underwent pregnancies.13 When this study was extended, no difference was found in the rate of structural valvular deterioration with pregnancy.4
Homograft valves are used in the aortic position and do not require long-term anticoagulation.14 There is limited information on the survival and valve complications of young women with homografts and no information on the effect of pregnancy on valve survival.15 16
In this study, we investigated which type of valve replacement (mechanical, bioprosthetic, or homograft) was associated with the greatest long-term survival in young women and compared the rate of valve complications with each valve type. We also investigated whether pregnancy was associated with increased or earlier valve loss.
| Methods |
|---|
|
|
|---|
We obtained information on cardiac status and outcome of pregnancies from 1972 to December 1994. Data on all women were collated from our hospital medical records (cardiac and obstetric), a national database, and the New Zealand register of deaths. Additional information on any pregnancies and consent to review medical records held by their local medical practitioner and other hospitals was obtained from 41% of women or their families.
The type of valve replacement was categorized as homograft, bioprosthetic (Hancock, Carpentier-Edwards, Medtronic Intact), or mechanical (Starr-Edwards, St Jude Medical, Medtronic Hall, Bjork-Shiley). Cardiac complications were classified according to published guidelines.17 Operative mortality was defined as death from any cause within 30 days of operation. Late deaths included all other deaths. Valve-related mortality was any death due to structural valvular deterioration, nonstructural dysfunction, thromboembolism, endocarditis, anticoagulant-related hemorrhage, or death at reoperation. Sudden, unexpected, unexplained deaths were included under valve-related death, unless autopsy proved that the death was not valve-related. Deaths due to any other cardiac conditions, in the presence of satisfactory functioning of the cardiac valve replacements, were classified as cardiac deaths.
Reoperation was defined as any operation that replaced a previous valve replacement. Valve loss was defined either as reoperation or a valve-related death. Structural valvular deterioration was any change in valve function resulting from an intrinsic abnormality that caused stenosis or regurgitation. Nonstructural valve dysfunction was any abnormality resulting in stenosis or regurgitation at the operated valve that was not intrinsic to the valve itself. Endocarditis was any infection involving a valve replacement and was diagnosed by standard clinical criteria, including positive blood cultures or evidence of endocarditis at reoperation. Thromboembolism was any valve thrombosis or embolism, excluding infection. It included any new, permanent or transient, focal or global neurological deficit (exclusive of hemorrhage) and any peripheral arterial emboli. A transient ischemic attack was a neurological deficit reversible within 24 hours, and a reversible ischemic neurological deficit was reversible within 3 weeks. Anticoagulant-related hemorrhage was any episode of internal or external bleeding that caused death, stroke, hospitalization, or operation or required transfusion.
Statistical Analyses
Women with concurrent valves of different types (for example, a
homograft valve at the aortic site and a mechanical valve at the mitral
site) were excluded, because any association between valve type and
outcome could not be attributed to a particular valve type. The women
could have >1 valve of the same type simultaneously and/or
could have a series of consecutive valves in the same site. Inclusion
of each valve as a separate entity in the survival analyses
would have resulted in duplicate counting of end points in women with
multiple concurrent valves. Hence, in the primary survival
analysis, the women's histories were partitioned into valve
states. A valve state began at insertion of a new valve and concluded
either when the data were censored (the last follow-up information
available), or the valve or valves were replaced, or the woman died.
These valve states were taken as independent measures, and the survival
plots were produced by the Kaplan-Meier method. Tests of significance
of difference between the valve types were produced by use of the
counting process formulation of Andersen and Gill,18 an
extension of the Cox proportional hazards regression model that takes
into account the time-dependent nature of the data. Operative deaths
were excluded from survival analyses, because these deaths were
not attributed to the new valve replacement. The single operative death
at replacement of a valve previously operated on was classified as a
late death of the initial valve replacement.
In the multivariate analyses, the mechanical valve group was compared with the bioprosthetic valve group. Homografts were excluded from these analyses, because all homografts were implanted in the aortic site and have a recognized different natural history. Potential confounding variables included in the model were valve site, year of operation, woman's age at valve replacement, number of concurrent valves (1, 2, or 3), ethnicity (categorized as Maori, Pacific Islander, or other), and whether the woman was pregnant at any time during the life of that valve. The large number of women with concurrent valves at 2 sites resulted in difficulties in classifying women according to their valve site. In the multivariate analysis, valve site was divided into mitral (including those with concurrent valves at the aortic or tricuspid site) and aortic or tricuspid site only.
To provide data consistent with previous studies, we also analyzed the end points attributable to a particular valve by valve rather than by patient. Reoperation, structural valve deterioration, and nonstructural valve dysfunction at the mitral and aortic sites were analyzed with Kaplan-Meier 10-year survival probabilities and the log-rank statistic.
| Results |
|---|
|
|
|---|
|
The characteristics of the women and types of valves are shown in Table 1
. Seventy-one women underwent 132
pregnancies. Table 2
shows patient
characteristics according to the type of valve. Women with mechanical
valves were older, had a greater proportion of valve replacements since
1980, and were more likely to have concurrent valves
(P<0.0001).
|
|
Survival of Women
Forty-five women (19.4%) died during the study period. There were
11 operative deaths (4.7%) and 34 late deaths (14.7%). The operative
death rate was 11.6% (95% CI, 3.9% to 25.1%) from 1972 to 1979,
2.9% (95% CI, 0.8% to 7.2%) from 1980 to 1989, and 4.1% (95% CI,
0.5% to 14.0%) from 1990 to 1992 (P=0.10). The late death
rate was 3 per 100 patient-years. Among the late deaths, 44% were
valve related, 20% were cardiac but not valve related, 11% were
noncardiac, and 25% were of unknown cause. At the time of death, 28
women had mechanical valves (3 operative deaths, 25 late deaths), 8 had
bioprosthetic valves (2 operative, 6 late), and 9 had
homografts (6 operative, 3 late). Including operative deaths, 10-year
survival was 69% in women with mechanical valves, compared with 82%
in the bioprosthetic valve group and 88% in homografts
(P=0.09).
There was a difference in long-term patient survival between the 3
valve types (P=0.002; Figure 2
). Ten-year survival (excluding
operative deaths) of women with mechanical valves was 70% (95% CI,
59% to 83%) compared with 84% (95% CI, 72% to 99%) in the
bioprosthetic valve group and 96% (95% CI, 91% to 100%) in
women with homografts. In the multivariate
analysis, women with mechanical valves were compared with those
with bioprosthetic valves. After adjustment for valve site, age
at valve replacement, year of operation, number of concurrent valves,
ethnicity, and pregnancy, the probability of an effect of valve type on
long-term survival was P=0.12. The relative risk (RR) of
death in women with mechanical valves compared with
bioprosthetic valves was 2.17 (95% CI, 0.78 to 5.88; Table 3
).
|
|
Maori and Pacific Island women had an 8-fold and 7-fold RR of death,
respectively, compared with European and Asian ethnic groups (Table 3
). There was no interaction between race and valve type on
survival (P=0.35). Pregnancy was associated with increased
patient survival (RR, 0.38; 95% CI, 0.17 to 0.84). Reliable data on
the postoperative NYHA classification were available in 80% of valves,
and of these, 96% were in NYHA class I or II. The relationship between
the type of valve replacement and patient survival did not change after
adjustment for the postoperative NYHA classification. The NYHA
classification was not included in the final model.
Valve Survival
Freedom from valve loss is shown in Figure 3
. At 10 years, the rate of valve loss
was 82% (95% CI, 62% to 92%) in women with bioprosthetic
valves compared with 29% (95% CI, 17% to 39%) in those with
mechanical valves and 28% (95% CI, 12% to 41%) in those with
homograft valves (P=0.0001). After exclusion of homografts
and adjustment for potential confounding variables, reduced
survival of bioprosthetic valves compared with mechanical
valves persisted (P=0.005; RR, 2.48; 95% CI, 1.35 to 4.57).
No other variable was associated with increased valve loss,
including valve site, age at valve replacement, or race. The data
suggested a different relationship between valve type and valve loss in
the mitral site compared with aortic or tricuspid sites
(P=0.05), with relatively greater bioprosthetic
valve loss in the mitral site.
|
In women with concurrent valves, valve-related death was not
attributable to a particular valve. Consequently, valve loss
(reoperation or valve-related death) at the aortic and mitral sites
could not be separately analyzed. However, the probability of
reoperation alone was analyzed according to valve site (Figure 4
, Table 4
). At the aortic site, comparison of
homografts with only bioprosthetic valves showed that
reoperation was less likely with homografts (P=0.03).
|
|
Effect of Pregnancy on Valve Survival
Overall, pregnancy did not influence valve loss (RR, 0.79; 95%
CI, 0.61 to 1.01). The relationship between pregnancy and valve loss
was analyzed separately for each valve type. Women with
bioprosthetic valves had the same rate of valve loss whether or
not they had undergone pregnancy (RR, 0.96; 95% CI, 0.68 to 1.35;
Figure 5
). These findings remained after
adjustment for potential confounding variables, including age.
Similarly, there was no difference in valve survival between women who
underwent pregnancy and those who did not in the homograft (RR, 0.65;
95% CI, 0.37 to 1.13) or mechanical valve (RR, 0.54; 95% CI, 0.27 to
1.08) groups.
|
Structural Valvular Deterioration
Structural valvular deterioration was most common in
bioprosthetic valves (P<0.0001; Figure 6
) and was the major reason for
replacement of these valves (91%). After adjustment for confounding
variables, structural valvular deterioration remained
greater in bioprosthetic than in mechanical valves
(P<0.0001). The risk of structural valvular
deterioration was 7-fold greater in the mitral than in aortic or
tricuspid sites (RR, 7.3; 95% CI, 1.3 to 40.3). Analysis by
valve showed that structural valvular deterioration at the
mitral site occurred in 84% (95% CI, 63% to 93%) of
bioprosthetic valves by 10 years, but none of the mechanical
valves (Figure 7
). Pregnancy did not
increase structural valvular deterioration of
bioprosthetic valves (RR, 0.84; 95% CI, 0.57 to 1.24;
P=0.39).
|
|
Nonstructural Valve Dysfunction
At 10 years, 95% (95% CI, 88% to 100%) of homograft valves,
96% (95% CI, 90% to 100%) of bioprosthetic valves, and 85%
(95% CI, 75% to 96%) of mechanical valves were free of nonstructural
valve dysfunction (P=0.09). Nonstructural valve dysfunction
according to valve site is shown in Table 4
.
Endocarditis
There was no difference in the rate of endocarditis with the
different valve types. At 10 years, endocarditis had occurred in 22%
(95% CI, 0% to 46%), 10% (95% CI, 0% to 19%), and 12% (95% CI,
3% to 21%) of women with bioprosthetic, homograft, and
mechanical valves, respectively (P=0.84).
Thromboembolic Events
Sixty women had 94 thromboembolic events. These events were 37
strokes (39%), 46 transient ischemic attacks or reversible
ischemic neurological deficits (49%), 7 emboli to other organs
or limbs (7%), and 4 isolated valve thrombi (4%). Thromboembolic
events were more common in women with mechanical than
bioprosthetic valves (P=0.0001; Figure 8
). Of women with mechanical valves, 45%
(95% CI, 34% to 55%) had a thromboembolic event within 5 years
compared with 13% (95% CI, 3% to 22%) of women with
bioprosthetic valves and 1.4% (95% CI, 0% to 5%) of women
with homograft valves (P=0.0001).
|
After adjustment for potential confounding variables, the RR of a thromboembolic event with mechanical compared with bioprosthetic valves was 3.07 (95% CI, 1.34 to 7.04). Pregnancy was associated with a lower risk of thromboembolism (RR, 0.46; 95% CI, 0.24 to 0.89). Neither the mitral position (RR, 0.71; 95% CI, 0.26 to 1.89) nor multiple concurrent valves (RR, 0.84; 95% CI, 0.46 to 1.51) were associated with increased thromboembolism.
When the thromboembolic event occurred, 31% of women with mechanical
valves and 83% of women with bioprosthetic valves were in
atrial fibrillation (P=0.02). In the mechanical valve group,
78 women were prescribed warfarin (7 with antiplatelet drugs), 5
received heparin, 1 was on aspirin alone, and in 1 woman the
anticoagulation regimen was unknown. An international normalized ratio
(INR) or prothrombin ratio (PR) was available at the time of the
thromboembolic event in 40 of the 78 women on warfarin. Among these, 28
(70%) had an INR or PR of <2.0, 4 had an INR or PR of 2 to 2.9, and
in 8 women the INR or PR was
3.
Anticoagulant-Related Hemorrhage
Twenty-nine women (26 with mechanical and 3 with
bioprosthetic valves) had 40 anticoagulant-related
hemorrhages resulting in hospital admissions. Twelve women had
menorrhagia, 9 epistaxis or hemoptysis, 9 hemorrhage after
surgery that required transfusion or further surgery, 4 hemarthroses, 2
renal hematomas, 2 trauma, 1 gastrointestinal bleed, and 1 cerebral
hemorrhage. At the time of hemorrhage, the type of
anticoagulation was warfarin (n=34), heparin (n=5), and both warfarin
and heparin (n=1). Among women treated with warfarin, the median INR
was 4.7 (range, 2 to 11.9; n=22) or median PR 3.1 (range, 2.3 to 4;
n=5). Fifty-five percent of women had an INR >4.
| Discussion |
|---|
|
|
|---|
Pregnancy was not associated with an increase in either structural valvular deterioration or valve loss of bioprosthetic, mechanical, or homograft valves. This is in keeping with a previous large controlled study, which found no increase in structural valvular deterioration of bioprosthetic valves with pregnancy.4 The association of pregnancy with greater survival of women is likely to be due to patient selection rather than pregnancy conferring a specific health benefit.
Women with mechanical valves had a high rate of thromboembolism
and hemorrhagic complications. Five years after mechanical valve
replacement,
50% of these young women had suffered a thromboembolic
event, with 39% having long-term sequelae. INR values at the time of
complications indicated poor compliance, either with taking warfarin or
with undergoing laboratory monitoring. The importance of factoring in
compliance and adherence in treatment outcome has recently been
highlighted.20 21 The majority of women in this study were
young Maori and Pacific Island women who had rheumatic heart disease, a
disease associated with poor living conditions. Young age and lower
income levels have been associated with poor compliance in other
chronic diseases.22 23 24
The majority of the mechanical valves in this study were Starr-Edwards valves. These valves carry a greater risk of thromboembolic complications than the newer, low-profile St Jude Medical or Medtronic Hall valves.1 5 The relevance of our findings to the newer valves is uncertain.
The majority of women with bioprosthetic or homograft valves have a successful pregnancy outcome. In the aortic site, the probability of reoperation of homograft valves was less than for bioprosthetic valves. Although the number of bioprosthetic valves in the aortic position was small, these data would support the use of homografts in preference to bioprosthetic valves at the aortic site.
In this study, we wished to address outcomes in terms of the woman's overall health, not just valve-related end points. Few long-term studies have specifically investigated this patient group with its unique problems. The complexity of valve combinations in many women made it difficult to attribute certain end points, including death, valve loss, thromboembolism, and hemorrhage, to a particular valve. To overcome this difficulty, our analysis was performed by "valve state." To allow comparison with previous studies, the end points attributable to an individual valve were also analyzed by valve. Limitations of this study include failure to use an assessment of global ventricular function in our analysis. Because this was a retrospective study over 2 decades, consistent ventricular function data were not available. Postoperative NYHA classification was also not included in the multivariate analyses because few women were in class III or IV, there was insufficient power to obtain meaningful results, and 20% had no information.
In conclusion, our data suggest that although valve survival is better with mechanical valves (predominantly Starr-Edwards), these valves may result in significant morbidity in young women and higher overall mortality. Because many young women wish to have children, the increase in pregnancy complications with mechanical valves needs to be considered. A successful pregnancy outcome is likely with bioprosthetic or homograft valves. Conversely, mitral bioprosthetic valves will probably require replacement by 10 years, with the associated operative risks. In deciding which valve replacement is preferable for a particular woman, the benefits and risks need to be balanced. Large, randomized trials are necessary to investigate long-term survival of young women with valve replacements, comparing a low-profile mechanical valve with a new-generation bioprosthetic valve in the mitral site and homografts with a bioprosthetic valve in the aortic site.
| Acknowledgments |
|---|
Received November 30, 1998; revision received February 26, 1999; accepted March 11, 1999.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
R. P Akhtar, A. R Abid, H. Zafar, M. A Cheema, and J. S Khan Anticoagulation in Pregnancy with Mechanical Heart Valves: 10-Year Experience Asian Cardiovasc Thorac Ann, December 1, 2007; 15(6): 497 - 501. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. B. Luciani, A. Favaro, G. Casali, F. Santini, and A. Mazzucco Ross Operation in the Young: A Ten-Year Experience Ann. Thorac. Surg., December 1, 2005; 80(6): 2271 - 2277. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Elkayam and F. Bitar Valvular Heart Disease and Pregnancy: Part II: Prosthetic Valves J. Am. Coll. Cardiol., August 2, 2005; 46(3): 403 - 410. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Ali, B. Iung, E. Lansac, P. Bruneval, and C. Acar Homograft replacement of the mitral valve: Eight-year results J. Thorac. Cardiovasc. Surg., October 1, 2004; 128(4): 529 - 534. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Ray, G. J. Murphy, and L. E. Shutt Recognition and management of maternal cardiac disease in pregnancy Br. J. Anaesth., September 1, 2004; 93(3): 428 - 439. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. C. Reimold and J. D. Rutherford Valvular Heart Disease in Pregnancy N. Engl. J. Med., July 3, 2003; 349(1): 52 - 59. [Full Text] [PDF] |
||||
![]() |
S. Cebotari, H. Mertsching, K. Kallenbach, S. Kostin, O. Repin, A. Batrinac, C. Kleczka, A. Ciubotaru, and A. Haverich Construction of Autologous Human Heart Valves Based on an Acellular Allograft Matrix Circulation, September 24, 2002; 106(12_suppl_1): I-63 - I-68. [Abstract] [Full Text] [PDF] |
||||
![]() |
Grown-up congenital heart (GUCH) disease: current needs and provision of service for adolescents and adults with congenital heart disease in the UK Heart, September 1, 2002; 88(90001): i1 - 14. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Gopal, I. M. Hudson, J. Ludmir, M. N. Braffman, S. Ewing, J. E. Bavaria, K.-L. Wong, and C. R. Bridges Homograft aortic root replacement during pregnancy Ann. Thorac. Surg., July 1, 2002; 74(1): 243 - 245. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Bloomfield Choice of heart valve prosthesis Heart, June 1, 2002; 87(6): 583 - 589. [Full Text] [PDF] |
||||
![]() |
M. Cotrufo, M. De Feo, L. S. De Santo, G. Romano, A. Della Corte, A. Renzulli, and C. Gallo Risk of Warfarin During Pregnancy With Mechanical Valve Prostheses Obstet. Gynecol., January 1, 2002; 99(1): 35 - 40. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. S Kabbani Is it Time to Look for an Alternative? Asian Cardiovasc Thorac Ann, June 1, 2001; 9(2): 79 - 81. [Full Text] [PDF] |
||||
![]() |
S. C Siu and J. M Colman CONGENITAL HEART DISEASE: Heart disease and pregnancy Heart, June 1, 2001; 85(6): 710 - 715. [Full Text] |
||||
![]() |
J. J. Collins Risks of Valve Replacements in Young Women Circulation, May 25, 1999; 99(20): 2613 - 2613. [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1999 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |