Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1999;99:1215-1221

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fogel, M. A.
Right arrow Articles by Haselgrove, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fogel, M. A.
Right arrow Articles by Haselgrove, J.
Related Collections
Right arrow CT and MRI
Right arrow Pediatric and congenital heart disease, including cardiovascular surgery

(Circulation. 1999;99:1215-1221.)
© 1999 American Heart Association, Inc.


Clinical Investigation and Reports

Caval Contribution to Flow in the Branch Pulmonary Arteries of Fontan Patients With a Novel Application of Magnetic Resonance Presaturation Pulse

Mark A. Fogel, MD; Paul M. Weinberg, MD; Jack Rychik, MD; Anne Hubbard, MD; Marshall Jacobs, MD; Thomas L. Spray, MD; John Haselgrove, PhD

From the Division of Cardiology, Departments of Pediatrics (M.A.F., P.M.W., J.R.), Radiology (A.H., J.H.), and Surgery (M.J., T.L.S.), The Children's Hospital of Philadelphia, The University of Pennsylvania School of Medicine.

Correspondence to Mark A. Fogel, MD, Wyeth-Ayerst Research, 145 King of Prussia Rd, Radnor, PA 19087. E-mail fogelm{at}war.wyeth.com


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowAppendix 1
down arrowReferences
 
Background—A complete understanding of fluid mechanics in Fontan physiology includes knowledge of the caval contributions to right (RPA) and left (LPA) pulmonary arterial blood flow, total systemic venous return, and relative blood flow to each lung.

Methods and Results—Ten Fontan patients underwent cine MRI. Three cine scans of the pulmonary arteries were performed: (1) no presaturation pulse, (2) a presaturation pulse labeling inferior vena cava (IVC) blood (signal void), and (3) a presaturation pulse labeling superior vena cava (SVC) blood. The relative signal decrease is proportional to the amount of blood originating from the labeled vena cava. This method was validated in a phantom. Whereas 60±6% of SVC blood flowed into the RPA, 67±12% of IVC blood flowed toward the LPA. Of the blood in the LPA and RPA, 48±14% and 31±17%, respectively, came from the IVC. IVC blood contributed 40±16% to total systemic venous return. The distributions of blood to each lung were nearly equal (RPA/LPA blood=0.94±11).

Conclusions—In Fontan patients with total cavopulmonary connection, SVC blood is directed toward the RPA and IVC blood is directed toward the LPA. Although the right lung volume is larger than the left, an equal amount of blood flow went to both lungs. LPA blood is composed of equal amounts of IVC and SVC blood because IVC contribution to total systemic venous return is smaller than that of the SVC. This technique and these findings can help to evaluate design changes of the systemic venous pathway to improve Fontan hemodynamics.


Key Words: Fontan procedure • blood flow • lung • magnetic resonance imaging • heart defects, congenital


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowAppendix 1
down arrowReferences
 
The fluid mechanics of pulmonary blood flow in Fontan physiology1 has been studied with increasing sophistication.1 2 3 4 5 6 The geometry of the systemic venous pathway has been implicated in various flow phenomena2 3 4 5 that may lead to energy losses.4 Much of this literature is predicated on the knowledge of the relative caval contributions to pulmonary flow and systemic venous return and the amount of blood flow to each lung. Furthermore, because a recent study suggests that caval contribution to total systemic venous return changes with age,7 it is likely that the various components of pulmonary blood flow also change, which has implications for systemic oxygen transport and the geometry of the systemic venous pathway. Until recently, quantification of these data in vivo has been nearly impossible.

Cine MRI, in which blood is signal-intense, can quantify this information in vivo.8 A presaturation pulse placed on blood entering the image plane produces a signal void.8 We hypothesized that when a presaturation pulse is placed on either vena cava of Fontan patients, the decrease in signal intensity in the pulmonary arteries is proportional to its contribution to each branch pulmonary artery. We used this concept to quantify, in a flow phantom in vitro and in Fontan patients in vivo, the contributions of both inferior (IVC) and superior (SVC) vena cava blood to right (RPA) and left (LPA) pulmonary artery flow, the contribution of each vena cava to total systemic venous return, and the relative amount of blood flow to both lungs.


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowAppendix 1
down arrowReferences
 
Phantom
A flow phantom was constructed to simulate the 4-way junction of the systemic venous pathway by connecting 4 pieces of flexible Tygon plastic tubing by use of a plastic 4-way "t"-connector (Figure 1Down). Fluid inflow was directed into 2 opposing arms from 2 elevated fluid reservoirs (designated "superior" and "inferior"). Two other arms (designated "right" and "left") carried outflow to 2 separate graduated cylinders placed below the 4-way "t"-connector. The "t"-connector had inputs and outputs perpendicular to each other. The tube inner diameter was 0.8 cm, the approximate diameter of the systemic venous pathway in Fontan patients. Clamps placed on each arm regulated each arm flow independently.



View larger version (54K):
[in this window]
[in a new window]
 
Figure 1. Validation in a flow phantom. Schematic on left displays setup of flow phantom. Four-way "t"-connector is highlighted with black crossed lines and arrowhead. Raw image data of a cine with no presaturation pulse (No Sat) (top right) and those with a presaturation pulse in either input limb (bottom right) are shown. Direction of flow is denoted by arrows, and 4-way "t"-connector is shown with arrowhead. See text for details. X% NaCl, Y% NaCl indicate chloride concentration in each output limb.

Flow rates were adjusted so that the mean velocity would be 30 to 40 cm/s, the approximate velocity in the systemic venous pathway of Fontan patients.6 One input reservoir contained water and the other contained 0.9% sodium chloride as a marker. Both reservoirs contained aqueous cupric sulfate to approximate the T1 relaxation properties of blood.

Measurement of the chloride concentration in both input and output reservoirs and measurement of flow rate in each output allowed calculation of the percentage of flow to each output reservoir. Chloride concentration was measured by a Ciba chloride analyzer.

The flow rate in the output limbs was measured with the graduated cylinder and stopwatch by determining the volume of fluid entering the graduated cylinder in 1 minute.

Patients
We prospectively studied 10 patients with functional single ventricles who underwent Fontan reconstruction at The Children's Hospital of Philadelphia between June 1, 1995, and March 31, 1996. Patients were 1.8±0.3 years old and were studied 1.6±0.4 weeks after Fontan completion. Nine patients had hypoplastic left heart syndrome, and 1 had critical subaortic stenosis with multiple ventricular septal defects and aortic hypoplasia. All patients underwent a lateral wall tunnel total cavopulmonary connection with side-to-side anastomosis of the right SVC to the RPA with patch augmentation of that junction. Patients with insignificant flow across the fenestrations in their baffle were chosen, with average aortic saturation of 91.4±2.9%. For them to enter the study, they could have no discrete pulmonary artery stenosis (as delineated by MRI); the diameters of the LPA and RPA were within 20% of each other and >50% of that of the descending aortic diameter. Patients with bilateral SVC–to–pulmonary artery connections were excluded. Patients were stable enough to undergo a 1-hour MRI scan under sedation. Informed consent was obtained from all participants. No patient had arrhythmias that precluded imaging in the scanner.

Magnetic Resonance Imaging
All patients were sedated and tolerated this without incident.

Studies were performed on a 1.5-T Siemens Vision system. The scanning protocol was as follows (Figure 2ADown and 2BDown).



View larger version (66K):
[in this window]
[in a new window]
 
Figure 2. Method used to obtain flow in pulmonary arteries from venae cavae and results. A, Top left, Spin-echo axial image at level of anastomosis of SVC to RPA and its connection to LPA. Right, Off-axis sagittal image of long axis of Fontan baffle. Both views are used as localizers for cine imaging (bottom left). Rectangles in bottom left demonstrate where signal intensity measurements were taken. Same rectangular position and size were used for all 3 cine MRIs. B, Left, Off-axis sagittal images where axial cine imaging (white box) of pulmonary arteries was performed. Hatched lines represent placement of a presaturation pulse (Presat pulse) (sat). Resulting cine without a sat (top), sat placement on IVC (middle), and sat placement on SVC (bottom) are shown.

1. Parameters we use to obtain spin-echo images of the heart have been described previously.8a We initially obtained spin-echo transverse images of the heart (Figure 2AUp, top left) to identify the site of the branch pulmonary artery connection to the SVC and the lateral wall tunnel baffle.

2. With the transverse images used to precisely localize the center of the systemic venous pathway (by multiplanar reconstruction), sagittal spin-echo images were acquired spanning the region of the heart (Figure 2AUp, right, and 2B, left) to localize the long axis of the systemic venous pathway. This was used to evaluate the superoinferior dimension of the branch pulmonary arteries for subsequent cine imaging and to determine placement of the presaturation band.

3. Gradient echo imaging (cine): Prospective ECG-gated, gradient-echo axial images were obtained at the level of the branch pulmonary artery anastomosis to the SVC (Figure 2AUp, bottom left, and Figure 2BUp, right. The position of the plane of the cine series is shown in Figure 2BUp, left). Eight to 10 images were obtained, spanning the entire cardiac cycle. The saturation pulse takes 1.0 ms to apply and is applied 4.7 ms before the center of the excitation pulse used in the acquisition sequence. The TR ranged from 40 to 60 ms (depending on the R-R interval), the TE was 7.3 ms, field of view was 180 to 280 mm, matrix was 128x256 pixels (which was interpolated to 256x256), and number of excitations was 3. Slice thickness was determined by the superoinferior width of the branch pulmonary artery and ranged from 6 to 10 mm.

Three sets of gradient-echo images of the branch pulmonary arteries at the same level were obtained (Figure 2BUp, right): (1) no presaturation pulse (Figure 2BUp, top); (2) a presaturation band placed inferior to the image plane (Figure 2BUp, middle) to destroy spins from IVC blood and produce a signal void. The band thickness extended from the IVC–right atrial junction to just below the imaging plane and ranged from 3 to 8 cm (Figure 2BUp, middle left); (3) and a presaturation band placed superior to the image plane (Figure 2BUp, bottom) to destroy the spins from SVC blood. The band thickness was equal to the previous presaturation band.

The leading edge of the saturation band was {approx}3 mm from the imaging plane.

The entire study was obtained in 1 hour. Respiratory gating was not performed, because respiration plays a minor role.6

Data Analysis
Images were downloaded onto a Sun SPARC station 10 (Sun Microsystems), and VIDA (volumetric image and display analysis)9 was used to manipulate the images.

Calculation of the contribution of fluid from the sodium chloride input reservoir to each output limb of the phantom used the formula (left limb is used as an example)

(1)
where [Cl]L and [Cl]R are the chloride concentrations in the left and right output reservoirs and QL and QR are the flow rates to the left and right output reservoirs, respectively.

The mean blood signal intensity in each pulmonary artery just distal to the anastomosis site was measured in a rectangle 3 mm in length and the width of the branch pulmonary artery (Figure 2AUp, bottom left). This was performed with the same rectangular shape and position used for all 3 cine image sets. The width of the branch pulmonary artery was also measured at that point. The data for each individual patient represent the integrated flow over the entire cardiac cycle.

The derivation of flow calculations to follow and exact formulas are given in the Appendix.

The IVC contribution to branch pulmonary artery flow is a function of both the decrease of total signal intensity in the branch pulmonary artery from the first to the second cine set (saturation of IVC blood producing a signal void) and the cube of the radius of the branch pulmonary artery. The SVC contribution to flow in each branch pulmonary artery is calculated similarly.

The percentage of blood in the LPA and RPA originating from the IVC is a function of the decrease in total signal intensity from the first to the second cine set (saturation of IVC blood producing a signal void) and the first to the third cine set (saturation of SVC blood producing a signal void) in the individual pulmonary artery. The percentages of blood in the LPA and RPA originating from the SVC were similar to that from the IVC, except that the numerators were different.

The amount of caval contribution to the total systemic venous return is a function of the sum of the decrease in total signal intensity from the first to the second cine set and the first to the third cine set in both branch pulmonary arteries.

The distribution of blood flow to each lung was the weighted average of percent caval contribution to the systemic venous return and the caval contribution to each pulmonary artery.

Statistics
Comparisons between 2 means were made by the paired 2-way Student's t test and the Wilcoxon rank sum test. All measurements are mean±SD. Intraobserver variability was determined by replicate measures using the coefficient of variation. A single trained observer performed all image analysis steps. Significance was taken at P<0.05. This analysis was performed on a PC using Excel 5.0 and JMP version 3.1.4 (SAS Institute Inc).


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowAppendix 1
down arrowReferences
 
Validation in a Phantom
The left output limb mean velocity was 32 cm/s, and that of the right output limb was 40 cm/s. Sodium chloride measurement of percent contribution of the sodium chloride input limb to flow in each output limb was within 10% of MRI measurements (Figure 1Up and TableDown).


View this table:
[in this window]
[in a new window]
 
Table 1. Flow Phantom Data

Caval Contribution to Pulmonary Arterial Flow
Figure 2BUp displays the raw image data. Note how similar and uniform the signal is in both RPA and LPA in the top right panel without a presaturation pulse. Compare this with the decreased signal intensity in the LPA in the middle panel when the IVC blood is saturated. Also compare this with the decreased signal intensity in the RPA in the bottom panel when the SVC blood is saturated.

The first and second sets of bars in Figure 3Down display the percent IVC and SVC contributions, respectively, to LPA and RPA flow. The IVC contributed significantly more blood to the LPA than the RPA, with an LPA/RPA flow ratio of 2.5±1.5 (Figure 2BUp, middle right). Significantly more blood in the SVC, however, was directed toward the RPA than the LPA, with an LPA/RPA flow ratio of 0.68±0.19 (Figure 2BUp, bottom right). The LPA/RPA flow ratio for the IVC and SVC differed significantly from each other (P=0.009).



View larger version (34K):
[in this window]
[in a new window]
 
Figure 3. Distribution of blood flow from each vena cava to branch pulmonary arteries (2 sets of bars on left) and caval origination of blood in each branch pulmonary artery (2 sets of bars on right). Error bars represent SDs. *P<0.05. Significantly more blood from IVC went to LPA. In addition, significantly more blood from SVC went to RPA. When blood in LPA was sampled, no significant difference was noted in caval origins of this flow; however, when RPA was sampled, significantly more blood came from SVC than IVC.

The third and fourth sets of bars in Figure 3Up display the amount of blood in the LPA and RPA originating from the IVC and SVC. Although the LPA blood was split nearly equally from flow originating in the IVC and SVC, RPA blood had a predominance of flow originating in the SVC.

Caval Contribution to Systemic Venous Return and Relative Pulmonary Blood Flow
Figure 2BUp again shows the raw image data. Note the generalized decrease in signal intensity in the pulmonary arteries in the bottom right panel relative to the middle right panel, consistent with the SVC contributing more flow to systemic venous return.

The first set of bars in Figure 4Down displays the amount of caval contribution to total systemic venous return. The IVC contributed significantly less blood to the total systemic venous return than the SVC. The second set of bars in Figure 4Down displays the amount of blood each branch pulmonary artery receives. The LPA and RPA received nearly equal amounts of blood, with an LPA/RPA ratio of 1.14±0.48.



View larger version (29K):
[in this window]
[in a new window]
 
Figure 4. Caval contribution to total systemic venous return (left) and total blood flow to each pulmonary artery (right). Error bars represent SDs. *P<0.05. SVC blood contributed significantly more to systemic venous return than IVC blood. Furthermore, equal amounts of blood flow were noted to each pulmonary artery.

The coefficient of variation for intraobserver variability was 6%.


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowAppendix 1
down arrowReferences
 
The fluid mechanics of Fontan physiology has received much attention,2 3 4 5 6 10 11 12 13 14 15 16 17 18 19 and ways to optimize this physiology have been explored. This included work into the basic driving force of blood flow into the pulmonary arteries in the absence of a "pulmonary" pumping chamber,6 10 11 12 13 14 15 16 17 18 19 optimization of the geometry of the systemic venous pathway,2 3 4 5 visualization of the velocity profiles,6 and computational fluid dynamics using finite-element analysis.2 This body of literature is predicated to various degrees on the knowledge of caval contributions to the branch pulmonary arteries, caval contributions to total systemic venous return, and relative blood flow to each lung. This underlies the need to obtain these values in vivo.

It has classically been thought that IVC blood carries a majority of systemic venous return.2 5 Recent suggested modifications to systemic venous pathway geometry take advantage of this by attempting to direct more IVC flow to the larger right lung and SVC flow to the smaller left lung.20 Salim et al7 recently demonstrated in normal children that caval contributions to systemic venous return vary with age, from a low in the IVC of 45% at {approx}2.2 years old (at 1.8 years old in our study, the IVC contribution was 40%) to a high of 65%, the adult value, at 6.6 years old. In the face of changing caval flow and a fixed systemic venous pathway geometry, the dynamics of systemic venous flow is likely to change with age. Indeed, IVC flow directed toward the LPA makes sense for a 2-year-old, but this same patient at almost 7 years old will wind up with a vast majority of total systemic venous return directed toward the smaller lung.

The purpose of this study was to delineate the components of pulmonary blood flow in vivo by use of MRI and a novel application of the presaturation pulse.

The presaturation pulse acts as a marker of blood from the vessel it is applied to by producing a signal void.8 By placing a presaturation "band" on a vessel and imaging "downstream," one can observe where the blood from that vessel goes by the "negative washout." This study used the concept of quantifying this flow by measuring the decrease in signal intensity, validated it in a phantom, and measured the various flow components in vivo. We used images triggered to the ECG because we have demonstrated that the vast majority of flow in the systemic venous pathway is due to cardiac effects.6

Our observation that a substantial amount of SVC blood preferentially streams to the RPA and a substantial amount of IVC blood preferentially streams to the LPA is consistent with anecdotal evidence by angiocardiography.2

The way blood preferentially streams from the vena cava is a function of the geometry of the systemic venous pathway, the amount of flow each vena cava carries, and the amount of flow each lung can accommodate. The geometry of the systemic venous pathway in our study group differs from the geometry studied by others in vitro.3 4 5 The systemic venous pathways in our study patients were created in 2 stages by use of the "hemi-Fontan" procedure: a side-to-side anastomosis of the SVC to the RPA, with patch augmentation anterior to the SVC-RPA connection.

The distance between the axial centers of the SVC and the intra-atrial baffle is called the "offset." Although in our patients, there is no lateral offset of the SVC and IVC to each other,4 there is an offset anteroposterior to the RPA and LPA from the SVC and IVC. Sharma et al4 noted that a zero offset of the SVC and IVC carries a 100% power loss; however, they did not study a side-to-side anastomosis or an anteroposterior offset.

LPA blood originated from both venae cavae equally. This is because the IVC (lower flow) contributes a majority of its blood to the LPA (40% of systemic venous returnx66% of IVC blood is directed to the LPA=0.26), whereas the SVC (larger flow) contributes a small amount of blood to the LPA (60% of systemic venous returnx40% of the blood is directed to the LPA=0.24).

A majority of RPA blood originated from the SVC. This is because the SVC (higher flow) contributes a majority of its blood to the RPA (60% of systemic venous returnx60% of the blood is directed to the RPA=0.36), whereas the IVC (lower flow) contributes a small amount of blood to the RPA (40% of systemic venous returnx33% of the blood is directed to the RPA=0.12).

As mentioned, the IVC has classically been thought to carry a majority of systemic venous return.2 5 Some groups have modified the systemic venous pathway geometry to take advantage of this20 by channeling IVC blood into the RPA (larger lung) and SVC blood into the LPA (smaller lung). Our data demonstrated that without this modification, the reverse is true. However, the IVC flow in our age group is the smaller of the two venae cavae (40%), consistent with the recent work by Salim et al7 in healthy children (45%). To some degree, however, the distribution of caval flow to each pulmonary artery is a function of the amount of flow in each vena cava. How the geometry of the systemic venous pathway will distribute blood to each pulmonary artery when the Fontan patient gets older is unknown. The strategy of directing IVC flow into the RPA makes long-term sense, because the adult value is reached by the age of 6.6 years.

The amount of flow each vena cava contributes to each pulmonary artery also depends on how much blood flow each lung can accommodate. We calculated that equal amounts of blood went to both lungs even though the right lung is larger and should hold more blood.2 4 5 Indeed, that is the rationale behind channeling the vena cava with higher flow to the right lung.20 Tamir et al21 noted that of the 5 single-ventricle patients studied by lung perfusion scans, 2 had decreased perfusion to the right lung and 3 had normal perfusion to both lungs. del Torso et al22 noted that 7 of 19 Fontan patients had decreased perfusion to the right lung as well. None of these studies had patients with lateral wall tunnel total cavopulmonary connections that would influence the distribution of blood flow because of streaming effects and the more laminar flow profile.6

The geometry of the lateral wall tunnel total cavopulmonary connection may direct blood preferentially to the LPA, "filling up" the smaller left lung and leaving the right lung "underfilled"; this may be the reason why both lungs receive equal perfusion. If true, altering the geometry of the systemic venous pathway may optimize perfusion to both lungs and thereby optimize systemic oxygenation. Other causes for equal perfusion to both lungs are the patient's age (affects caval contribution to the systemic venous return), thromboembolic phenomenon, or autonomic nervous system alterations.

Our studies were performed early after Fontan reconstruction, before hospital discharge. It is unknown how the flow components would change later in the patient's course.

Limitations
Because MRI measures fixed planes in space, through-plane motion may cause "partial volume" of some of the signal intensity. Because the pulmonary arteries are minimally pulsatile in this physiology, this would not change our results significantly.

Similarly, "partial-volume effects" can occur when blood vessels are imaged because the signal intensity at the edges averages the signal of the blood and the surrounding soft tissue. This problem was avoided by measuring the decrease in signal intensity from images with a presaturation pulse and those without a presaturation pulse. The difference between the signal intensities is solely from blood.

The saturation pulse takes 1.0 ms to apply and is applied 4.7 ms before the center of the excitation pulse used in the acquisition sequence. During that period, some recovery of spins would have occurred. This effect is not appreciable because of the small amount of time available for the spins to recover. It would also not change the relative percentages because spin recovery would occur in both pulmonary arteries.

The right-to-left flow from systemic to pulmonary venous pathways across the baffle fenestration would, in theory, alter the exact numbers for relative caval contribution to systemic venous return only. To minimize this, we studied patients with insignificant flow across this (aortic saturation, 91.4±2.9%).

It should be noted that this study was performed in sedated, supine patients. The findings may be altered with increased patient activity.

Finally, this technique is not applicable to patients with turbulent flow in the pulmonary arteries because turbulence would create a signal void and alter the calculations. This would probably apply only to patients with moderate to severe bilateral pulmonary artery obstruction.

Conclusions
This study has validated the use of a presaturation pulse to quantify the relative contributions of caval flow to pulmonary artery flow and total systemic venous return. It may be used to evaluate flow components in the various systemic venous pathways created surgically.

In Fontan patients, SVC blood is directed more toward the RPA and IVC blood is directed more toward the LPA. Nevertheless, LPA blood is composed of equal amounts of IVC and SVC blood, and the majority of RPA blood is from the SVC. In addition, the IVC accounts for only 40% of the total systemic venous return, and equal amounts of blood flow to each lung. These findings may help in designing a better Fontan procedure and change the way the systemic venous pathway geometry is created.


*    Acknowledgments
 
The authors acknowledge the help of Henry Drott, MD, in the phantom validation.


*    Appendix 1
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*Appendix 1
down arrowReferences
 
Derivation of Blood Flow Calculations
The assumptions (where k, k', etc, are constants) are that (1) the imaging slice thickness equals the pulmonary artery diameter; (2) flow in the systemic venous pathway is laminar6 ; (3) the signal intensity is proportional to the volume of tissue; and (4) after caval blood saturation, the decrease in signal intensity, {delta}I, is proportional to the blood volume ({delta}Vol) from the cava:

(2)
The remaining signal is not equal to the signal from the unsaturated vena cava because nonblood tissue may be present in each pixel.

{delta}Vol enters an artery in time {delta}t and fills the vessel for a distance (vm)({delta}t), where vm is mean velocity. Saturated blood is the sum of all {delta}Vol in that artery, which is the integral of {delta}I in each pixel over area A extending the pulmonary artery width and the length of (vm)({delta}t). Area A is

(3)
where R is the arterial radius. Thus,

(4)

Substituting the product of the average signal drop (<{delta}I>) in area A by area A (Figure 1Up, Equation 3Up) over time {delta}t into Equation 4Up, we obtain

(5)
Velocity determination is not necessary for the final calculations (measuring proportional flow, not absolute flow). Assuming that the pressure gradient (dP/dx) and viscosity along both arteries are equal (no pulmonary artery stenosis or hypoplasia), Poiseuille's law states that vm along each artery is proportional to the square of the radius: vm {propto} R2. Substituting in Equation 5Up,

(6)
Because of periodic flow, we integrate Equation 6Up over the cycle (heartbeat) to obtain

(7)
where k'''=(k'')({delta}t). Writing D for {sum} <{delta}I> (the sum of all average signal intensity drops over the cardiac cycle), we obtain

Use the notation RL, RR=LPA and RPA radii, respectively; DIL, DSL=average intensity drop (D) in the LPA when the IVC and SVC are saturated, respectively; DIR, DSR=D in the RPA when the IVC and SVC are saturated, respectively; VIL, VSL=volume of blood (V) entering the LPA when the IVC and SVC are saturated, respectively; and VIR, VSR=V entering the RPA when the IVC and SVC are saturated, respectively.

1. Caval contribution to each pulmonary artery: Using the IVC and LPA as an example, the fraction of blood from the IVC that enters the LPA is

(8)

Other ratios of caval blood entering the pulmonary arteries are written similarly.

2. The percentage of blood in each pulmonary artery from each vena cava: Using the IVC and LPA as an example, the fraction of blood in the LPA that originated from the IVC is

(9)

Other ratios of pulmonary artery blood that originated from each vena cava are written similarly.

3. Caval contribution to total systemic venous return: Using the IVC as an example, the fraction of total systemic venous return that that is contributed from the IVC is


(10)

The SVC contribution to total systemic venous return is written similarly.

4. Relative blood flow to each lung: Use the following notation: IVR, SVR=% IVC and % SVC contribution to total systemic venous return, respectively; IL, SL=% IVC and % SVC contribution to LPA flow, respectively; and IR, SR=% IVC and % SVC contribution to RPA flow, respectively (all values calculated from the previous equations). Using the LPA as an example, the fraction of total systemic venous return that enters the LPA is (IVR)(IL)+(SVR)(SL).

The % for RPA flow is written similarly, with IR and SR instead of IL and SL.

Received February 19, 1998; revision received November 9, 1998; accepted November 18, 1998.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
up arrowAppendix 1
*References
 
1. Fontan F, Baudet E. Surgical repair of tricuspid atresia. Thorax. 1971;26:240–248.[Abstract/Free Full Text]

2. de Laval MR, Dubini G, Migliavacca F, Jalali H, Camporini G, Reddington A, Pietrabissa R. Use of computational fluid dynamics in the design of surgical procedures: application to the study of competitive flows in cavopulmonary connections. J Thorac Cardiovasc Surg. 1996;111:502–513.[Abstract/Free Full Text]

3. de Laval MR, Kilner P, Gewillig M, Bull C. Total cavopulmonary connection: a logical alternative to atriopulmonary connection for complex Fontan operations. J Thorac Cardiovasc Surg. 1988;96:682–695.[Abstract]

4. Sharma S, Goudy S, Walker P, Panchal S, Ensley A, Kanter K, Tam V, Fyfe D, Yoganathan A. In vitro flow experiments for determination of optimal geometry of total cavopulmonary connection for surgical repair of children with functional single ventricle. J Am Coll Cardiol. 1996;27:1264–1269.[Abstract]

5. Lardo AC, Webber SA, del Nido PJ, Myers JL, Boyle GJ, Lee ET, Siewers RD, Cape EG. Does the right lung receive preferential blood flow in Fontan repair? Comparison of total cavopulmonary and atriopulmonary connections: an in vitro flow study. Circulation. 1995;92(suppl I):I-123. Abstract.

6. Fogel MA, Weinberg PM, Hoydu A, Hubbard A, Rychik J, Jacobs M, Haselgrove J. The nature of flow in the systemic venous pathway in Fontan patients utilizing magnetic resonance blood tagging. J Thorac Cardiovasc Surg. 1997;114:1032–1041.[Abstract/Free Full Text]

7. Salim MA, DiSessa TG, Arheart KL, Alpert BS. Contribution of superior vena caval flow to total cardiac output in children: a Doppler echocardiographic study. Circulation. 1995;92:1860–1865.[Abstract/Free Full Text]

8. Horowitz AL. MRI Physics for Radiologists. New York, NY: Springer-Verlag; 1995:103–144.

8. Fogel MA, Weinberg PM, Hoydu AK, Hubbard AM, Rychick J, Jacobs ML, Fellows KE, Haselgrove J. Effect of surgical reconstruction on flow profiles in the aorta using magnetic resonance blood tagging. Ann Thorac Surg.. 1997;63:1691–1700.[Abstract/Free Full Text]

9. Hoffman EA, Gnanaprakasam D, Gupta KB, Hoford JD, Kugelmass SD, Kulawiec RS. VIDA: An environment for multidimensional image display and analysis. Proc SPIE. 1992;1660:694–711.

10. Frommelt PC, Snider AR, Meliones JN, Vermilion RP. Doppler assessment of pulmonary artery flow patterns and ventricular function after the Fontan operation. Am J Cardiol. 1991;68:1211–1215.[Medline] [Order article via Infotrieve]

11. Penny DJ, Redington AN. Doppler echocardiographic evaluation of pulmonary blood flow after the Fontan operation: the role of the lungs. Br Heart J. 1991;66:372–374.[Abstract/Free Full Text]

12. Miura T, Matsuda H, Nakano S, Kishimoto H, Kato H, Hirose H, Kawashima Y. Assessment of pulmonary blood flow after total cavopulmonary shunt operation and the modified Fontan procedure for univentricular heart. J Cardiol. 1988;18:837–844.[Medline] [Order article via Infotrieve]

13. Qureshi SA, Richheimer R, McKay R, Arnold R. Doppler echocardiographic evaluation of pulmonary artery flow after modified Fontan procedure: importance of atrial contraction. Br Heart J. 1990;64:272–276.[Abstract/Free Full Text]

14. Nakazawa M, Nakanishi T, Okuda H, Satomi G, Nakae S, Imai Y, Takao A. Dynamics of right heart flow in patients after Fontan procedure. Circulation. 1984;69:306–312.[Abstract/Free Full Text]

15. Hagler DJ, Seward JB, Tajik AJ, Ritter DG. Functional assessment of the Fontan operation: combined M-mode, two-dimensional and Doppler echocardiographic studies. J Am Coll Cardiol. 1984;4:756–764.[Abstract]

16. DiSessa TG, Child JS, Perloff JK, Wu L, Williams RG, Laks H, Friedman WF. Systemic venous and pulmonary arterial flow patterns after Fontan's procedure for tricuspid atresia or single ventricle. Circulation. 1984;70:898–902.[Abstract/Free Full Text]

17. Rebergen SA, Ottenkamp J, Doornbos J, van der Wall EE, Chin JG, de Roos A. Postoperative pulmonary flow dynamics after Fontan surgery: assessment with nuclear magnetic resonance velocity mapping. J Am Coll Cardiol. 1993;21:123–131.[Abstract]

18. Penny DJ, Hayek Z, Redington AN. The effects of positive and negative extrathoracic pressure ventilation on pulmonary blood flow after the total cavopulmonary shunt procedure. Int J Cardiol. 1991;30:128–130.[Medline] [Order article via Infotrieve]

19. Redington AN, Penny DJ, Shinebourne EA. Pulmonary blood flow after total cavopulmonary shunt. Br Heart J. 1991;65:213–217.[Abstract/Free Full Text]

20. Laks H, Ardehali A, Grant PW, Permut L, Aharon A, Kuhn M, Isabel-Jones J, Galindo A. Modification of the Fontan procedure: superior vena cava to left pulmonary artery connection and inferior vena cava to right pulmonary artery connection with adjustable atrial septal defect. Circulation. 1995;91:2943–2947.[Abstract/Free Full Text]

21. Tamir A, Melloul M, Berant M, Horev G, Lubin E, Blieden LC, Zeevi B. Lung perfusion scans in patients with congenital heart defects. J Am Coll Cardiol. 1992;19:383–388.[Abstract]

22. del Torso S, Milanesi O, Bui F, Benetti E, Stellin G, Mazzucco A, Daliento L, Svaluto Moreolo G, Pellegrino PA. Radionuclide evaluation of lung perfusion after the Fontan procedure. Int J Cardiol. 1988;20:107–116.[Medline] [Order article via Infotrieve]




This article has been cited by other articles:


Home page
CirculationHome page
A. Frydrychowicz, R. Arnold, A. Harloff, C. Schlensak, J. Hennig, M. Langer, and M. Markl
In Vivo 3-Dimensional Flow Connectivity Mapping After Extracardiac Total Cavopulmonary Connection
Circulation, July 8, 2008; 118(2): e16 - e17.
[Full Text] [PDF]


Home page
CirculationHome page
K. K. Whitehead, K. Pekkan, H. D. Kitajima, S. M. Paridon, A. P. Yoganathan, and M. A. Fogel
Nonlinear Power Loss During Exercise in Single-Ventricle Patients After the Fontan: Insights From Computational Fluid Dynamics
Circulation, September 11, 2007; 116(11_suppl): I-165 - I-171.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
D. D. Soerensen, K. Pekkan, D. de Zelicourt, S. Sharma, K. Kanter, M. Fogel, and A. P. Yoganathan
Introduction of a New Optimized Total Cavopulmonary Connection
Ann. Thorac. Surg., June 1, 2007; 83(6): 2182 - 2190.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
C. P. Cheng, R. J. Herfkens, A. L. Lightner, C. A. Taylor, and J. A. Feinstein
Blood flow conditions in the proximal pulmonary arteries and vena cavae: healthy children during upright cycling exercise
Am J Physiol Heart Circ Physiol, August 1, 2004; 287(2): H921 - H926.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
V.E. Hjortdal, K. Emmertsen, E. Stenbog, T. Frund, M. R. Schmidt, O. Kromann, K. Sorensen, and E.M. Pedersen
Effects of Exercise and Respiration on Blood Flow in Total Cavopulmonary Connection: A Real-Time Magnetic Resonance Flow Study
Circulation, September 9, 2003; 108(10): 1227 - 1231.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
C. P. Cheng, R. J. Herfkens, and C. A. Taylor
Inferior vena caval hemodynamics quantified in vivo at rest and during cycling exercise using magnetic resonance imaging
Am J Physiol Heart Circ Physiol, April 1, 2003; 284(4): H1161 - H1167.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. Fratz, J. Hess, M. Schwaiger, S. Martinoff, and H. C. Stern
More Accurate Quantification of Pulmonary Blood Flow by Magnetic Resonance Imaging Than by Lung Perfusion Scintigraphy in Patients With Fontan Circulation
Circulation, September 17, 2002; 106(12): 1510 - 1513.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. Amodeo, M. Grigioni, G. Oppido, C. Daniele, G. D'Avenio, G. Pedrizzetti, S. Giannico, S. Filippelli, and R. M. Di Donato
The beneficial vortex and best spatial arrangement in total extracardiac cavopulmonary connection
J. Thorac. Cardiovasc. Surg., September 1, 2002; 124(3): 471 - 478.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
E M Pedersen, E V Stenbog, T Frund, K Houlind, O Kromann, K E Sorensen, K Emmertsen, and V E Hjortdal
Flow during exercise in the total cavopulmonary connection measured by magnetic resonance velocity mapping
Heart, June 1, 2002; 87(6): 554 - 558.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fogel, M. A.
Right arrow Articles by Haselgrove, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fogel, M. A.
Right arrow Articles by Haselgrove, J.
Related Collections
Right arrow CT and MRI
Right arrow Pediatric and congenital heart disease, including cardiovascular surgery