| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
(Circulation. 2001;103:2535.)
© 2001 American Heart Association, Inc.
Brief Rapid Communications |
From the Department of Internal Medicine II (S.A., T.G., D.R., H.D., W.M., W.G.D.), the Institute of Medical Physics (S.U., W.A.K.), and the Institute of Diagnostic Radiology (C.S., E.W., W.B., U.B.), University of Erlangen-Nürnberg, Germany.
Correspondence to Dr S. Achenbach, Medizinische Klinik II, Universität Erlangen, Östliche Stadtmauerstr 29, 91054 Erlangen, Germany. E-mail stephan.achenbach{at}rzmail.uni-erlangen.de
BackgroundMultislice spiral computed tomography (MSCT) with retrospectively ECG-gated image reconstruction permits coronary artery visualization. We investigated the methods ability to identify high-grade coronary artery stenoses and occlusions.
Methods and
ResultsA total of 64 consecutive
patients were studied by MSCT (4x1 mm cross-sections, 500-ms
rotation, table feed 1.5 mm/rotation, intravenous
contrast agent, retrospectively ECG-gated image reconstruction). All
coronary arteries and side branches with a luminal diameter
2.0 mm were assessed concerning evaluability and the presence of
high-grade stenoses (>70% diameter stenosis) or
occlusions. Results were compared with quantitative coronary
angiography. Of 256 coronary arteries (left main, left anterior
descending, left circumflex and right coronary artery,
including their respective side branches), 174 could be evaluated
(68%). In 19 patients (30%), all arteries were evaluable. Artifacts
caused by coronary motion were the most frequent reason for
unevaluable arteries. Overall, 32 of 58 high-grade stenoses and
occlusions were detected by MSCT (58%). In evaluable arteries, 32 of
35 lesions were detected, and the absence of stenosis was
correctly identified in 117 of 139 arteries (sensitivity, 91%;
specificity, 84%). If analysis was extended to all
stenoses with >50% diameter reduction, sensitivity was 85%
(40 of 47) and specificity was 76% (96 of
127).
ConclusionsMSCT with retrospective ECG gating permits the detection of coronary artery stenoses with high accuracy if image quality is sufficient, but its clinical use may presently be limited due to degraded image quality in a substantial number of cases, mainly due to rapid coronary motion.
Key Words: imaging coronary disease tomography
This article has been cited by other articles:
![]() |
L HUSMANN, O GAEMPERLI, I VALENTA, T SCHEPIS, H SCHEFFEL, P STOLZMANN, S LESCHKA, L DESBIOLLES, B MARINCEK, H ALKADHI, et al. Impact of vessel attenuation on quantitative coronary angiography with 64-slice CT Br. J. Radiol., August 1, 2009; 82(980): 649 - 653. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Donnino, J. E. Jacobs, J. V. Doshi, E. M. Hecht, D. C. Kim, J. S. Babb, and M. B. Srichai Dual-Source Versus Single-Source Cardiac CT Angiography: Comparison of Diagnostic Image Quality Am. J. Roentgenol., April 1, 2009; 192(4): 1051 - 1056. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. B. Meijboom, M. F.L. Meijs, J. D. Schuijf, M. J. Cramer, N. R. Mollet, C. A.G. van Mieghem, K. Nieman, J. M. van Werkhoven, G. Pundziute, A. C. Weustink, et al. Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, multivendor study. J. Am. Coll. Cardiol., December 16, 2008; 52(25): 2135 - 2144. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. M. Henneman, J. D. Schuijf, J. M. van Werkhoven, G. Pundziute, E. E. van der Wall, J. W. Jukema, and J. J. Bax Multi-slice computed tomography coronary angiography for ruling out suspected coronary artery disease: what is the prevalence of a normal study in a general clinical population? Eur. Heart J., August 2, 2008; 29(16): 2006 - 2013. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Saremi, S. Channual, S. Krishnan, S. V. Gurudevan, J. Narula, and A. Abolhoda Bachmann Bundle and Its Arterial Supply: Imaging with Multidetector CT--Implications for Interatrial Conduction Abnormalities and Arrhythmias Radiology, August 1, 2008; 248(2): 447 - 457. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Saremi, S. Channual, A. Abolhoda, S. V. Gurudevan, J. Narula, and J. C. Milliken MDCT of the S-Shaped Sinoatrial Node Artery Am. J. Roentgenol., June 1, 2008; 190(6): 1569 - 1575. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. N. Shetty, K. G. Bis, A. R. Vyas, A. Kumar, A. Anderson, and M. Balasubramaniam Contrast Volume Reduction with Superior Vena Cava Catheter-Directed Coronary CT Angiography: Comparison with Peripheral IV Contrast Enhancement in a Swine Model Am. J. Roentgenol., April 1, 2008; 190(4): W247 - W254. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Schroeder, S. Achenbach, F. Bengel, C. Burgstahler, F. Cademartiri, P. de Feyter, R. George, P. Kaufmann, A. F. Kopp, J. Knuuti, et al. Cardiac computed tomography: indications, applications, limitations, and training requirements: Report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology Eur. Heart J., February 2, 2008; 29(4): 531 - 556. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Pugliese, N. R. Mollet, M. G. M. Hunink, F. Cademartiri, K. Nieman, R. T. van Domburg, W. B. Meijboom, C. Van Mieghem, A. C. Weustink, M. L. Dijkshoorn, et al. Diagnostic Performance of Coronary CT Angiography by Using Different Generations of Multisection Scanners: Single-Center Experience Radiology, February 1, 2008; 246(2): 384 - 393. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. S. White and D. Kuo Chest Pain in the Emergency Department: Role of Multidetector CT Radiology, December 1, 2007; 245(3): 672 - 681. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Oncel, G. Oncel, and A. Tastan Effectiveness of Dual-Source CT Coronary Angiography for the Evaluation of Coronary Artery Disease in Patients with Atrial Fibrillation: Initial Experience Radiology, December 1, 2007; 245(3): 703 - 711. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Saremi, A. Abolhoda, O. Ashikyan, J. C. Milliken, J. Narula, S. V. Gurudevan, K. Kaushal, and A. Raney Arterial Supply to Sinuatrial and Atrioventricular Nodes: Imaging with Multidetector CT Radiology, December 1, 2007; 246(1): 99 - 107. [Abstract] [Full Text] [PDF] |
||||
![]() |
V Russo, V Gostoli, L Lovato, M Montalti, A Marzocchi, G Gavelli, A Branzi, R Di Bartolomeo, and R Fattori Clinical value of multidetector CT coronary angiography as a preoperative screening test before non-coronary cardiac surgery Heart, December 1, 2007; 93(12): 1591 - 1598. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. D. Schuijf, G. Pundziute, J. W. Jukema, H. J. Lamb, J. C. Tuinenburg, B. L. van der Hoeven, A. de Roos, J. H. C. Reiber, E. E. van der Wall, M. J. Schalij, et al. Evaluation of Patients with Previous Coronary Stent Implantation with 64-Section CT Radiology, November 1, 2007; 245(2): 416 - 423. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Saremi and S. Krishnan Cardiac Conduction System: Anatomic Landmarks Relevant to Interventional Electrophysiologic Techniques Demonstrated with 64-Detector CT RadioGraphics, November 1, 2007; 27(6): 1539 - 1565. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. T. Wilson, P. Gopalakrishnan, and T. Tak Noninvasive Cardiac Imaging with Computed Tomography Clin. Med. Res., October 1, 2007; 5(3): 165 - 171. [Abstract] [Full Text] [PDF] |
||||
![]() |
E Ghersin, A Kerner, L Gruberg, Y Bar-El, S Abadi, and A Engel Left ventricular pseudoaneurysm or diverticulum: differential diagnosis and dynamic evaluation by catheter left ventriculography and ECG-gated multidetector CT Br. J. Radiol., September 1, 2007; 80(957): e209 - e211. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. K. Vanhoenacker, M. H. Heijenbrok-Kal, R. Van Heste, I. Decramer, L. R. Van Hoe, W. Wijns, and M. G. M. Hunink Diagnostic Performance of Multidetector CT Angiography for Assessment of Coronary Artery Disease: Meta-analysis Radiology, August 1, 2007; 244(2): 419 - 428. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Herzog, P. L. Zwerner, J. R. Doll, C. D. Nielsen, S. A. Nguyen, G. Savino, T. J. Vogl, P. Costello, and U. J. Schoepf Significant Coronary Artery Stenosis: Comparison on Per-Patient and Per-Vessel or Per-Segment Basis at 64-Section CT Angiography Radiology, July 1, 2007; 244(1): 112 - 120. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Herzog, S. A. Nguyen, G. Savino, P. L. Zwerner, J. Doll, C. D. Nielsen, T. G. Flohr, T. J. Vogl, P. Costello, and U. J. Schoepf Does Two-Segment Image Reconstruction at 64-Section CT Coronary Angiography Improve Image Quality and Diagnostic Accuracy? Radiology, July 1, 2007; 244(1): 121 - 129. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Yanai, H. Yoshida, Y. Tomono, and N. Tada Atherosclerosis imaging in statin intervention trials QJM, May 1, 2007; 100(5): 253 - 262. [Full Text] [PDF] |
||||
![]() |
A. Kumar, K. G. Bis, A. Shetty, A. Vyas, A. Anderson, M. Balasubramaniam, W. O'Neill, and W. Stein Aortic Root Catheter-Directed Coronary CT Angiography in Swine: Coronary Enhancement with Minimum Volume of Iodinated Contrast Material Am. J. Roentgenol., May 1, 2007; 188(5): W415 - W422. [Abstract] [Full Text] [PDF] |
||||
![]() |
A.-R. Zeina, M. Odeh, J. Blinder, U. Rosenschein, and E. Barmeir Myocardial Bridge: Evaluation on MDCT Am. J. Roentgenol., April 1, 2007; 188(4): 1069 - 1073. [Abstract] [Full Text] [PDF] |
||||
![]() |
M M Henneman, J D Schuijf, J W Jukema, H J Lamb, A de Roos, P Dibbets, M P Stokkel, E E van der Wall, and J J Bax Comprehensive cardiac assessment with multislice computed tomography: evaluation of left ventricular function and perfusion in addition to coronary anatomy in patients with previous myocardial infarction Heart, December 1, 2006; 92(12): 1779 - 1783. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Achenbach Computed Tomography Coronary Angiography J. Am. Coll. Cardiol., November 21, 2006; 48(10): 1919 - 1928. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Budoff, S. Achenbach, R. S. Blumenthal, J. J. Carr, J. G. Goldin, P. Greenland, A. D. Guerci, J. A.C. Lima, D. J. Rader, G. D. Rubin, et al. Assessment of Coronary Artery Disease by Cardiac Computed Tomography: A Scientific Statement From the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology Circulation, October 17, 2006; 114(16): 1761 - 1791. [Full Text] [PDF] |
||||
![]() |
T. Wittlinger, I. Martinovic, R. Moosdorf, and A. Moritz Imaging of calcified coronary arteries with multislice computed tomography. Asian Cardiovasc Thorac Ann, August 1, 2006; 14(4): 321 - 327. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Plass, J. Grunenfelder, S. Leschka, H. Alkadhi, F. R. Eberli, S. Wildermuth, G. Zund, and M. Genoni Coronary artery imaging with 64-slice computed tomography from cardiac surgical perspective. Eur. J. Cardiothorac. Surg., July 1, 2006; 30(1): 109 - 116. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Haller, C. Kaiser, P. Buser, G. Bongartz, and J. Bremerich Coronary artery imaging with contrast-enhanced MDCT: extracardiac findings. Am. J. Roentgenol., July 1, 2006; 187(1): 105 - 110. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. K. Pannu, J. E. Jacobs, S. Lai, and E. K. Fishman Coronary CT angiography with 64-MDCT: assessment of vessel visibility. Am. J. Roentgenol., July 1, 2006; 187(1): 119 - 126. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Hoffmann, A. J. Pena, R. C. Cury, S. Abbara, M. Ferencik, F. Moselewski, U. Siebert, T. J. Brady, and J. T. Nagurney Cardiac CT in Emergency Department Patients with Acute Chest Pain. RadioGraphics, July 1, 2006; 26(4): 963 - 978. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Zanzonico, L. N. Rothenberg, and H. W. Strauss Radiation Exposure of Computed Tomography and Direct Intracoronary Angiography: Risk Has its Reward J. Am. Coll. Cardiol., May 2, 2006; 47(9): 1846 - 1849. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Hoffmann, M. Ferencik, R. C. Cury, and A. J. Pena Coronary CT Angiography J. Nucl. Med., May 1, 2006; 47(5): 797 - 806. [Abstract] [Full Text] [PDF] |
||||
![]() |
C Peebles Computed tomographic coronary angiography: how many slices do you need? Heart, May 1, 2006; 92(5): 582 - 584. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. A.S. Cordeiro and J. A.C. Lima Atherosclerotic plaque characterization by multidetector row computed tomography angiography. J. Am. Coll. Cardiol., April 18, 2006; 47(8 Suppl): C40 - C47. [Abstract] [Full Text] [PDF] |
||||
![]() |
A Vacca, P Siotto, A Cauli, R Montisci, P Garau, V Ibba, A Mameli, G Passiu, S Iliceto, and A Mathieu Absence of epicardial coronary stenosis in patients with systemic sclerosis with severe impairment of coronary flow reserve Ann Rheum Dis, February 1, 2006; 65(2): 274 - 275. [Full Text] [PDF] |
||||
![]() |
D. S. Berman, R. Hachamovitch, L. J. Shaw, J. D. Friedman, S. W. Hayes, L. E.J. Thomson, D. S. Fieno, G. Germano, P. Slomka, N. D. Wong, et al. Roles of Nuclear Cardiology, Cardiac Computed Tomography, and Cardiac Magnetic Resonance: Assessment of Patients with Suspected Coronary Artery Disease J. Nucl. Med., January 1, 2006; 47(1): 74 - 82. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Ghersin, D. Litmanovich, R. Dragu, S. Rispler, J. Lessick, A. Ofer, O. R. Brook, L. Gruberg, R. Beyar, and A. Engel 16-MDCT Coronary Angiography Versus Invasive Coronary Angiography in Acute Chest Pain Syndrome: A Blinded Prospective Study Am. J. Roentgenol., January 1, 2006; 186(1): 177 - 184. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. J. W. Sandstede, J. Stoffels, F. Wendel, C. Ritter, M. Beer, and D. Hahn Different Reconstruction Intervals for Exclusion of Coronary Artery Calcifications by Retrospectively Gated MDCT Am. J. Roentgenol., January 1, 2006; 186(1): 193 - 197. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Raggi, A. Taylor, Z. Fayad, D. O'Leary, S. Nissen, D. Rader, and L. J. Shaw Atherosclerotic Plaque Imaging: Contemporary Role in Preventive Cardiology Arch Intern Med, November 14, 2005; 165(20): 2345 - 2353. [Abstract] [Full Text] [PDF] |
||||
![]() |
P M Donnelly, J D S Higginson, and P D Hanley Multidetector CT coronary angiography: have we found the holy grail of non-invasive coronary imaging? Heart, November 1, 2005; 91(11): 1385 - 1388. [Abstract] [Full Text] [PDF] |
||||
![]() |
T Beck, C Burgstahler, A Kuettner, A F Kopp, M Heuschmid, C D Claussen, and S Schroeder Clinical use of multislice spiral computed tomography in 210 highly preselected patients: experience with 4 and 16 slice technology Heart, November 1, 2005; 91(11): 1423 - 1427. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Gaspar, D. A. Halon, B. S. Lewis, S. Adawi, J. E. Schliamser, R. Rubinshtein, M. Y. Flugelman, and N. Peled Diagnosis of Coronary In-Stent Restenosis With Multidetector Row Spiral Computed Tomography J. Am. Coll. Cardiol., October 18, 2005; 46(8): 1573 - 1579. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. R. Mollet, F. Cademartiri, C. A.G. van Mieghem, G. Runza, E. P. McFadden, T. Baks, P. W. Serruys, G. P. Krestin, and P. J. de Feyter High-Resolution Spiral Computed Tomography Coronary Angiography in Patients Referred for Diagnostic Conventional Coronary Angiography Circulation, October 11, 2005; 112(15): 2318 - 2323. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Fuster, Z. A. Fayad, P. R. Moreno, M. Poon, R. Corti, and J. J. Badimon Atherothrombosis and High-Risk Plaque: Part II: Approaches by Noninvasive Computed Tomographic/Magnetic Resonance Imaging J. Am. Coll. Cardiol., October 4, 2005; 46(7): 1209 - 1218. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Achenbach, D. Ropers, F.-K. Pohle, D. Raaz, J. von Erffa, A. Yilmaz, G. Muschiol, and W. G. Daniel Detection of coronary artery stenoses using multi-detector CT with 16x0.75 collimation and 375 ms rotation Eur. Heart J., October 1, 2005; 26(19): 1978 - 1986. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Kaiser, J. Bremerich, S. Haller, H. P. Brunner-La Rocca, G. Bongartz, M. Pfisterer, and P. Buser Limited diagnostic yield of non-invasive coronary angiography by 16-slice multi-detector spiral computed tomography in routine patients referred for evaluation of coronary artery disease Eur. Heart J., October 1, 2005; 26(19): 1987 - 1992. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Leschka, H. Alkadhi, A. Plass, L. Desbiolles, J. Grunenfelder, B. Marincek, and S. Wildermuth Accuracy of MSCT coronary angiography with 64-slice technology: first experience Eur. Heart J., August 1, 2005; 26(15): 1482 - 1487. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Kefer, E. Coche, G. Legros, A. Pasquet, C. Grandin, B. E. Van Beers, J.-L. Vanoverschelde, and B. L. Gerber Head-to-Head Comparison of Three-Dimensional Navigator-Gated Magnetic Resonance Imaging and 16-Slice Computed Tomography to Detect Coronary Artery Stenosis in Patients J. Am. Coll. Cardiol., July 5, 2005; 46(1): 92 - 100. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Fuster and R. J. Kim Frontiers in Cardiovascular Magnetic Resonance Circulation, July 5, 2005; 112(1): 135 - 144. [Full Text] [PDF] |
||||
![]() |
M. Namdar, T. F. Hany, P. Koepfli, P. T. Siegrist, C. Burger, C. A. Wyss, T. F. Luscher, G. K. von Schulthess, and P. A. Kaufmann Integrated PET/CT for the Assessment of Coronary Artery Disease: A Feasibility Study J. Nucl. Med., June 1, 2005; 46(6): 930 - 935. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. T. Lau, L. J. Ridley, M. C. Schieb, D. B. Brieger, S. B. Freedman, L. A. Wong, S. K. Lo, and L. Kritharides Coronary Artery Stenoses: Detection with Calcium Scoring, CT Angiography, and Both Methods Combined Radiology, May 1, 2005; 235(2): 415 - 422. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Heuschmid, A. Kuettner, S. Schroeder, T. Trabold, A. Feyer, M. D. Seemann, R. Kuzo, C. D. Claussen, and A. F. Kopp ECG-Gated 16-MDCT of the Coronary Arteries: Assessment of Image Quality and Accuracy in Detecting Stenoses Am. J. Roentgenol., May 1, 2005; 184(5): 1413 - 1419. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. R Mollet, F. Cademartiri, and P. J de Feyter Non-invasive multislice CT coronary imaging Heart, March 1, 2005; 91(3): 401 - 407. [Full Text] [PDF] |
||||
![]() |
T. Schlosser, K. Pagonidis, C. U. Herborn, P. Hunold, K.-U. Waltering, T. C. Lauenstein, and J. Barkhausen Assessment of Left Ventricular Parameters Using 16-MDCT and New Software for Endocardial and Epicardial Border Delineation Am. J. Roentgenol., March 1, 2005; 184(3): 765 - 773. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Nakanishi, Y. Kayashima, R. Inoue, K. Sumii, and Y. Gomyo Pitfalls in 16-Detector Row CT of the Coronary Arteries RadioGraphics, March 1, 2005; 25(2): 425 - 438. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. R. M. Jongbloed, M. S. Dirksen, J. J. Bax, E. Boersma, K. Geleijns, H. J. Lamb, E. E. van der Wall, A. de Roos, and M. J. Schalij Atrial Fibrillation: Multi-Detector Row CT of Pulmonary Vein Anatomy prior to Radiofrequency Catheter Ablation--Initial Experience Radiology, March 1, 2005; 234(3): 702 - 709. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. S. Shim, Y. Kim, and S. M. Lim Improvement of Image Quality with {beta}-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography Am. J. Roentgenol., February 1, 2005; 184(2): 649 - 654. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Yamamuro, E. Tadamura, S. Kubo, H. Toyoda, T. Nishina, M. Ohba, R. Hosokawa, T. Kimura, N. Tamaki, M. Komeda, et al. Cardiac Functional Analysis with Multi-Detector Row CT and Segmental Reconstruction Algorithm: Comparison with Echocardiography, SPECT, and MR Imaging Radiology, February 1, 2005; 234(2): 381 - 390. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. D. Schuijf, J. J. Bax, J. W. Jukema, H. J. Lamb, H. W. Vliegen, E. E. van der Wall, and A. de Roos Noninvasive Evaluation of the Coronary Arteries With Multislice Computed Tomography in Hypertensive Patients Hypertension, February 1, 2005; 45(2): 227 - 232. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. R. Mollet, F. Cademartiri, G. P. Krestin, E. P. McFadden, C. A. Arampatzis, P. W. Serruys, and P. J. de Feyter Improved diagnostic accuracy with 16-row multi-slice computed tomography coronary angiography J. Am. Coll. Cardiol., January 4, 2005; 45(1): 128 - 132. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. L. Gerber, E. Coche, A. Pasquet, E. Ketelslegers, D. Vancraeynest, C. Grandin, B. E. Van Beers, and J.-L. J. Vanoverschelde Coronary Artery Stenosis: Direct Comparison of Four-Section Multi-Detector Row CT and 3D Navigator MR Imaging for Detection--Initial Results Radiology, January 1, 2005; 234(1): 98 - 108. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. D. Schuijf, J. J. Bax, J. W. Jukema, H. J. Lamb, H. W. Vliegen, L. P. Salm, A. de Roos, and E. E. van der Wall Noninvasive Angiography and Assessment of Left Ventricular Function Using Multislice Computed Tomography in Patients With Type 2 Diabetes Diabetes Care, December 1, 2004; 27(12): 2905 - 2910. [Abstract] [Full Text] [PDF] |
||||
![]() |
S Schroeder, A Kuettner, T Wojak, J Janzen, M Heuschmid, T Athanasiou, T Beck, C Burgstahler, C Herdeg, C D Claussen, et al. Non-invasive evaluation of atherosclerosis with contrast enhanced 16 slice spiral computed tomography: results of ex vivo investigations Heart, December 1, 2004; 90(12): 1471 - 1475. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Koos, A. H. Mahnken, A. M. Sinha, J. E. Wildberger, R. Hoffmann, and H. P. Kuhl Aortic Valve Calcification as a Marker for Aortic Stenosis Severity: Assessment on 16-MDCT Am. J. Roentgenol., December 1, 2004; 183(6): 1813 - 1818. [Abstract] [Full Text] [PDF] |
||||
![]() |
A F Kopp, A Kuttner, T Trabold, M Heuschmid, S Schroder, and C D Claussen Multislice CT in cardiac and coronary angiography Br. J. Radiol., December 1, 2004; 77(suppl_1): S87 - S97. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. K. Hofmann, K. H. Zou, P. Costello, and U. J. Schoepf Electrocardiographically Gated 16-Section CT of the Thorax: Cardiac Motion Suppression Radiology, December 1, 2004; 233(3): 927 - 933. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Cademartiri, K. Nieman, A. van der Lugt, R. H. Raaijmakers, N. Mollet, P. M. T. Pattynama, P. J. de Feyter, and G. P. Krestin Intravenous Contrast Material Administration at 16-Detector Row Helical CT Coronary Angiography: Test Bolus versus Bolus-tracking Technique Radiology, December 1, 2004; 233(3): 817 - 823. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. R. Davies, J. H. Rudd, and P. L. Weissberg Molecular and Metabolic Imaging of Atherosclerosis J. Nucl. Med., November 1, 2004; 45(11): 1898 - 1907. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Hoffmann, F. Moselewski, R. C. Cury, M. Ferencik, I.-k. Jang, L. J. Diaz, S. Abbara, T. J. Brady, and S. Achenbach Predictive Value of 16-Slice Multidetector Spiral Computed Tomography to Detect Significant Obstructive Coronary Artery Disease in Patients at High Risk for Coronary Artery Disease: Patient- Versus Segment-Based Analysis Circulation, October 26, 2004; 110(17): 2638 - 2643. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kuettner, T. Trabold, S. Schroeder, A. Feyer, T. Beck, A. Brueckner, M. Heuschmid, C. Burgstahler, A. F. Kopp, and C. D. Claussen Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology: Initial clinical results J. Am. Coll. Cardiol., September 15, 2004; 44(6): 1230 - 1237. [Abstract] [Full Text] [PDF] |
||||
![]() |
P.J. de Feyter and K. Nieman Noninvasive multi-slice computed tomography coronary angiography: An emerging clinical modality J. Am. Coll. Cardiol., September 15, 2004; 44(6): 1238 - 1240. [Full Text] [PDF] |
||||
![]() |
J. F. Viles-Gonzalez, M. Poon, J. Sanz, T. Rius, K. Nikolaou, Z. A. Fayad, V. Fuster, and J. J. Badimon In Vivo 16-Slice, Multidetector-Row Computed Tomography for the Assessment of Experimental Atherosclerosis: Comparison With Magnetic Resonance Imaging and Histopathology Circulation, September 14, 2004; 110(11): 1467 - 1472. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. K. Willmann, D. Weishaupt, R. Kobza, F. R. Verdun, B. Seifert, B. Marincek, and T. Boehm Coronary Artery Bypass Grafts: ECG-gated Multi-Detector Row CT Angiography--Influence of Image Reconstruction Interval on Graft Visibility Radiology, August 1, 2004; 232(2): 568 - 577. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Schoenhagen, S. S. Halliburton, A. E. Stillman, S. A. Kuzmiak, S. E. Nissen, E. M. Tuzcu, and R. D. White Noninvasive Imaging of Coronary Arteries: Current and Future Role of Multi-Detector Row CT Radiology, July 1, 2004; 232(1): 7 - 17. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. J. Schoepf, C. R. Becker, B. M. Ohnesorge, and E. K. Yucel CT of Coronary Artery Disease Radiology, July 1, 2004; 232(1): 18 - 37. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. R. Mollet, F. Cademartiri, K. Nieman, F. Saia, P. A. Lemos, E. P. McFadden, P. M. T. Pattynama, P. W. Serruys, G. P. Krestin, and P. J. de Feyter Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris J. Am. Coll. Cardiol., June 16, 2004; 43(12): 2265 - 2270. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Martuscelli, A. Romagnoli, A. D'Eliseo, C. Razzini, M. Tomassini, M. Sperandio, G. Simonetti, and F. Romeo Accuracy of thin-slice computed tomography in the detection of coronary stenoses Eur. Heart J., June 2, 2004; 25(12): 1043 - 1048. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Hoffmann, R. Millea, C. Enzweiler, M. Ferencik, S. Gulick, J. Titus, S. Achenbach, D. Kwait, D. Sosnovik, and T. J. Brady Acute Myocardial Infarction: Contrast-enhanced Multi-Detector Row CT in a Porcine Model Radiology, June 1, 2004; 231(3): 697 - 701. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. J. Riederer Coronary Artery MR Angiography: Are We There Yet? Radiology, May 1, 2004; 231(2): 302 - 304. [Full Text] [PDF] |
||||
![]() |
H. S. Choi, B. W. Choi, K. O. Choe, D. Choi, K.-J. Yoo, M.-I. Kim, and J. Kim Pitfalls, Artifacts, and Remedies in Multi- Detector Row CT Coronary Angiography RadioGraphics, May 1, 2004; 24(3): 787 - 800. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Desjardins and E. A. Kazerooni ECG-Gated Cardiac CT Am. J. Roentgenol., April 1, 2004; 182(4): 993 - 1010. [Full Text] [PDF] |
||||
![]() |
A. Kuettner, A. F. Kopp, S. Schroeder, T. Rieger, J. Brunn, C. Meisner, M. Heuschmid, T. Trabold, C. Burgstahler, J. Martensen, et al. Diagnostic accuracy of multidetector computed tomography coronary angiography in patients with angiographically proven coronary artery disease J. Am. Coll. Cardiol., March 3, 2004; 43(5): 831 - 839. [Abstract] [Full Text] [PDF] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2001 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |